Cooking/Window Opening and Associated Increases of Indoor PM2.5 and NO2 Concentrations of Children’s Houses in Kaohsiung, Taiwan

1
Department of Public Health, College of Health Science, Kaohsiung Medical University, Kaohsiung City 807, Taiwan
2
Epidemiology, Human Genetics, and Environmental Sciences, School of Public Health, University of Texas Health Science Center at Houston, Houston, TX 77046, USA
3
Institute of Environmental Engineering, College of Engineering, National Sun Yat-Sen University, Kaohsiung City 807, Taiwan
4
Department of Medical Research, Kaohsiung Medical University Hospital, Kaohsiung City 807, Taiwan
5
Research Center for Environmental Medicine, Kaohsiung Medical University, Kaohsiung City 807, Taiwan
*
Author to whom correspondence should be addressed.
Appl. Sci. 2019, 9(20), 4306; https://doi.org/10.3390/app9204306
Submission received: 29 August 2019 / Revised: 2 October 2019 / Accepted: 2 October 2019 / Published: 14 October 2019
(This article belongs to the Special Issue Indoor Air Quality)

Abstract

:
High concentrations of air pollutants and increased morbidity and mortality rates are found in industrial areas, especially for the susceptible group, children; however, most studies use atmospheric dispersion modeling to estimate household air pollutants. Therefore, the aim of this study was to assess the indoor air quality, e.g., CO, CO2, NO2, SO2, O3, particulate matter with aerodynamic diameter less than 2.5 μm (PM2.5), and their influence factors in children’s homes in an industrial city. Children in the “general school”, “traffic school”, and “industrial school” were randomly and proportionally selected. Air pollutants were sampled for 24 h in the living rooms and on the balcony of their houses and questionnaires of time–microenvironment–activity-diary were recorded. The indoor CO concentration of the traffic area was significantly higher than that of the industrial area and the general area. In regard to the effects of window opening, household NO2 and PM2.5 concentrations during window opening periods were significantly higher than of the reference periods. For the influence of cooking, indoor CO2, NO2, and PM2.5 levels during the cooking periods were significantly higher than that of the reference periods. The indoor air quality of children in industrial cities were affected by residential areas and household activities.

1. Introduction

According to the Environmental White Paper of Taiwan Environmental Protection Agency (Taiwan EPA), the annual average concentrations of ambient CO, NO2, SO2, and O3 in 2008 were 0.47 ppm, 16.90 ppb, 4.35 ppb, and 29.09 ppb, respectively. The Kaohsiung–Pingtung area was the worse polluted area in Taiwan and accounted for 5.93% of station-days of the Pollutant Standards Index (PSI) > 100. Especially, Kaohsiung is a heavy industrial city. In industrial areas, high concentrations of air pollutants and increased morbidity and mortality rates are found, depending on the types of industrial activities and exposure concentrations in residential areas [1,2]. Children are more susceptible to the health effects of air pollution than adults due to not having full development of their pulmonary metabolic capacity [3]. Long-term exposure of air pollution may affect children’s lung development [4]. Previously, most of the studies revealed that ambient pollution such as particulate matter with aerodynamic diameter less than 10 and 2.5 μm (PM10 and PM2.5), sulfur dioxide (SO2), nitrogen dioxide (NO2), volatile organic compounds (VOCs), etc. in industrial areas may increase the risk of respiratory symptoms, and attacks of asthma in children [1,5,6]. Therefore, indoor air quality of children’s homes may be very important to children’s health, especially in industrial cities, since children spend most of their time at home [7].
Indoor air quality may be affected by indoor human activities such as cooking, smoking, cleaning, etc. and the infiltration of outdoor pollutants produced from the traffic or industrial sources [8,9,10,11]. For example, SO2, NOx, PM2.5, and carbon monoxide (CO), the major conventional air pollutant in steel plants, oil refineries, and vehicular exhaust emissions [12,13,14], may enter a house through cracks and windows [15,16]. In addition, if the indoor air is not well ventilated, the air pollutants may accumulate in the indoor environment, and then seriously affects the health of the inhabitants [17].
Previously, atmospheric dispersion modeling was used to estimate the household concentrations of indoor air pollutants in industrial areas [1,18,19]. Only a few studies actually measured individual exposure [20] and household concentrations [21,22,23], and these studies only focused on PM mass concentrations, elemental composition, and VOCs concentrations. However, other air pollutants e.g., CO, carbon dioxide (CO2), NO2, SO2, and ozone (O3) in households in industrial cities also need to be considered. Therefore, the main aim of this study was to assess the indoor air quality including CO, CO2, NO2, SO2, O3, and PM2.5, temperature and relative humidity, and their influence factors (e.g., window opening and cooking) in children’s homes in an industrial city—Kaohsiung City. To our knowledge, this is the first study to assess the indoor air quality including CO, CO2, NO2, SO2, and O3 in children’s homes in an industrial city. In addition, the second aim was to evaluate potential determinants of indoor air pollutants levels of occupants’ activities, including cooking and window opening, etc. It is also the first study to reveal the differences of air pollutants between cooking periods/window opening periods and reference periods through a time–microenvironment–activity-diary via a questionnaire in one-hour time segments.

2. Materials and Methods

2.1. Study Area

Kaohsiung City (22°38′ N, 120°17′ E), located in southern Taiwan and with the population density of 9962.6/km2 in 2010, is the largest industrialized harbor city in Taiwan with intense traffic and heavy industries including the largest steel plant (the China Steel Corporation, which also ranked the 19th steel mill in the world in 2005), the largest oil refinery (the CPC Corporation), the largest international shipbuilding (it ranked 6th in the world in 2005) in Taiwan, and many petrochemical industries.

2.2. Study Design

In April 2010, we selected three elementary schools in Kaohsiung City. One elementary school had a general air quality monitoring station of Taiwan EPA on the roof of the 4th floor, so we called this school a “general school”. Another elementary school was 0.33 km from Taiwan EPA’s traffic air quality monitoring station and was regarded as a "traffic school". The “industrial school” was an elementary school located near the Xiaogang Industrial Zone in Kaohsiung City and about 0.30 km from Taiwan EPA’s air monitoring station. The study population was limited to children who attended these schools. The number of students in the “general school”, “traffic school”, and “industrial school” were 1669, 987, and 960, respectively. After obtaining the assented of the child and the permission of the parents, we recorded the subjects who agreed to home visits for environmental sampling. Children were randomly and proportionally selected from each school to participate in this study. Finally, the home visits of 32, 16, and 12 participants in the “general school”, “traffic school”, and “industrial school”, respectively, were completed between April 2010 and October 2010.

2.3. Air Sampling

Indoor air pollutants including CO, CO2, NO2, SO2, O3, PM2.5, temperature, and relative humidity were measured by real-time monitoring equipment for 24 h in the living rooms. We also measured the atmospheric CO, CO2, NO2, SO2, O3, and PM2.5 on the balcony as outdoor concentrations. All instruments were placed on the bench at a height of approximately 1 m above the ground. The PM was measured by a real-time optical scattering instrument (DUSTTRAK™ DRX Aerosol Monitor Models 8533, TSI Incorporated, Shoreview, MN, USA) and the measurements were taken every 1 s by the flow rate of 3.0 L/min with detectable concentration from 0.001 to 150 mg/m3. The CO, CO2, NO2, SO2, indoor temperature, and relative humidity were also recorded (KD-airboxx, KD Engineering, Blaine, WA, USA) every 15 s with the measuring range of 0 to 500 ppm, 0 to 10,000 ppm, 0 to 20 ppm, 0 to 20 ppm, 0 to 50 °C, and 5% to 95%, respectively. The accuracy of CO, CO2, NO2, and SO2 were ±3% of reading or 2 ppm (whichever was greater), ±5% of reading or 60 ppm (whichever was greater), 0.25 ppm, and 0.25 ppm, respectively. The resolution of CO, CO2, NO2, and SO2 were 0.1 ppm, 1 ppm, 0.01 ppm, and 0.01 ppm, respectively. In terms of O3, it was detected by a real-time monitoring (Model 202 Ozone monitorTM, 2B Technologies Inc, Boulder, CO, USA) every 5 min with the measuring range of 0 to 250 ppm.
All real-time monitors were manufacturer-calibrated for the study in the beginning of this study and every six months. Before every field sampling, the DUSTTRAK™ DRX Aerosol Monitor Models 8533 was calibrated using emery oil aerosol and nominally adjusted to the respirable mass of standard ISO 12103-1, A1 test dust, (Arizona Dust); and the KD-airboxx, the Model 202 Ozone monitorTM were calibrated using zero gas and span gas. In addition, the zero calibrators of instruments were carried out, and the flow rate of sampling pump also was adjusted by Gilian Gilibrator-2NIOSH Primary Standard Air Flow Calibrator (Sensidyne, St. Petersburg, FL, USA) before every household sampling.

2.4. Household Characteristics

In addition, household characteristics including the number of occupants, air-conditioning use, smoking, incense burning, etc. were also recorded in the questionnaires. In addition to household characteristics, data on potential determinants of indoor air pollutants levels of occupants’ activities, including cooking and window opening, etc. were obtained through a time–microenvironment–activity-diary via a questionnaire in one-hour time segments. We also actually evaluated the effects of window opening and cooking on indoor air pollutants. The window opening periods were defined from a time–microenvironment–activity-diary and two one-hour periods before and after window opening periods were defined as the reference periods. In terms of cooking, the cooking periods were the periods recorded by participants as cooking from a time–microenvironment–activity-diary and the reference periods were defined as the one-hour periods before the cooking periods.

2.5. Ethics

This study was approved by the Institutional Review Board of the Kaohsiung Medical University Chung-Ho Memorial Hospital (the protocol number was KMU-IRB-990045). Informed written consent was obtained from each child (the phonetic version of the consent form that the children read and signed) and their legal guardians.

2.6. Statistical Analyses

Statistical analyses in this study were performed using SAS version 9.3 (SAS Institute of Taiwan Ltd, Taipei, Taiwan). Descriptive statistics were used to describe the 24-hour of average of exposure data (indoor/outdoor air pollutant concentrations, temperature, and relative humidity). The concentrations of air pollutants were not normally distributed (data not shown), therefore we analyzed our data by nonparametric statistics, also known as distribution-free statistics. A paired Student’s t-test was used to assess the difference in the average concentration of air pollutants between indoor and outdoor, between window opening periods and reference periods, and between cooking periods and reference periods. With the objective of evaluating significant differences among the areas (general, traffic, and industry) for all air pollutants variables, data were analyzed using one-way analysis of variance (ANOVA) with Scheffe multiple comparison test. The generalized estimating equations (GEE) is a general statistical method in a longitudinal study with small samples for adjusting time interference, in which each time point is an independent event. Finally, the relationships between the 24-hour average concentrations of indoor air pollutants (dependent variable) and household characteristics (independent variable) were analyzed using GEE, adjusting for other household characteristics, and time interference. A p-value of less than 0.05 was considered significant.

3. Results

Table 1 shows the descriptive statistics of 24-h average indoor and outdoor air pollutants, temperature, and relative humidity in 60 houses. When indoor air pollutants were paired with outdoors within the same home, we found that the 24-hour average concentrations of indoor CO, CO2, and NO2 were significantly higher than the 24-hour average of outdoors concentrations, whereas, outdoor O3 and PM2.5 concentrations were significantly higher than indoor concentrations (all p < 0.01). The average distance between homes of subjects and their school were 0.86 km, 0.94 km, and 1.46 km in general, traffic, and industrial areas, respectively, as well as, the average distance between homes of subjects and the nearest air monitoring station were 1.07 km, 0.97 km, and 1.46 km in general, traffic, and industrial areas, respectively.
In comparison with household air pollutants of three areas, Table S1 shows descriptive statistics of 24-h average concentration of indoor air pollutants in the houses of traffic, industry, and general areas. Figure 1 shows the 24-h average concentration of indoor air pollutants (A) CO, (B) CO2, (C) NO2, and (D) O3 in the houses of traffic, industry, and general areas. We found the 24-hour average concentration of indoor CO concentration of the traffic area was significantly higher than that of the industrial area, and the general area with all p < 0.01 (Figure 1, Table S1). In addition, the 24-hour average concentration of indoor CO2 level of the general area was significantly lower than that of the traffic area, and industrial area (all p < 0.01) (Figure 1, Table S1). Finally, both the 24-hour average concentration of household NO2 and O3 concentrations of the industrial area were significantly lower than that of the traffic area, and general area (all p < 0.01) (Figure 1, Table S1). Moreover, there was no statistical significant difference of the 24-hour average concentration of indoor SO2 and PM2.5 between the three areas (Table S1).
Table 2 shows the percentage of household characteristics including window opening, residents >4 people, cooking, etc. in traffic, industry, and general areas. We found compared with traffic area and industrial area, the general area had a higher percentage of window opening, cooking, and air- conditioning use; moreover, a lower percentage of residents > 4 people, smoker, incense burning, mosquito coil burning, and essential oil using.
The following Table 3 shows the ratios of air pollutants during window opening periods to the reference periods and the differences in air pollutants between window opening periods and reference periods. The median ratios of pollutants during window opening periods to the reference periods for NO2 and PM2.5 were 1.56 and 1.13, respectively with the maximum values up to 5.23 and 1.85 respectively (Table 3). The NO2 and PM2.5 levels during window opening periods were significantly higher than that of the reference periods, and the maximum increased values were 53.25 ppb and 44 μg/m3, respectively. Table 4 shows the ratios of air pollutants during cooking periods to reference periods and the differences in air pollutants between window opening periods and reference periods. The median ratios of pollutants during cooking periods to the reference periods for CO, CO2, NO2, and PM2.5 were 0.93, 1.06, 1.11, and 1.09, respectively. The concentrations of CO2, NO2, and PM2.5 during the cooking periods were significantly higher than those of reference periods with increased concentrations of 26.17 ppm, 5.40 ppb, and 5 μg/m3, respectively. However, the CO level during cooking periods was significantly lower than that of the reference periods with the decreased concentration of 0.25 ppm.
Table 5 shows the association between air pollutants concentrations (24-h average concentration of air pollutants in each house as dependent variable), and household characteristics by using the generalized estimating equations model. This study revealed that CO concentrations were positively associated with the number of occupants, cleaning, smoking, incense burning, mosquito coil burning, and negatively correlated to cooking with a statistical significance. Indoor CO2 concentrations were positively associated with the number of occupants, air-conditioning use, smoking, incense burning, and negatively correlated to mosquito coil burning with a statistical significance. In addition, significantly higher NO2 levels were found in the homes with smokers than homes without smokers. There were significantly positive associations between indoor SO2 concentrations and smoking and incense burning. In terms of O3, indoor O3 concentrations were positively associated with the window opening and negatively correlated to the number of occupants, incense burning, and essential oil use with a statistical significance. For PM2.5, it was positively associated with cleaning and incense burning with a statistical significance.

4. Discussion

Our results showed that the outdoor concentrations of O3 and PM2.5 were significantly higher than indoor concentrations. The Kaohsiung City is a city with intense traffic and heavy industries, and previous studies believed SO2, NOx, PM2.5, and CO were the major conventional air pollutant in steel plants, oil refineries, and vehicular exhaust emissions [12,13,14,24]. In addition, outdoor O3 might be formed by the photochemical reaction of nitrogen oxides absorbing sunlight, and VOCs [25,26]. According to the PSI database from 2010 to 2012 of Taiwan EPA, only O3 and total suspended particulate (TSP) would exceed the standard [27]. This may be the reason why outdoor PM2.5 and O3 concentrations were higher than indoor concentrations. In our study, outdoor median PM2.5 levels (90 μg/m3) were higher than both the National Ambient Air Quality Standards of UAS and Taiwan EPA with the 24-hour standard for PM2.5 of 35 μg/m3. In addition, the median value of indoor PM2.5 concentrations (40 μg/m3) was also higher than the criteria of indoor air quality (IAQ) standards of Taiwan EPA (35 μg/m3/24 h). In our study, indoor CO, CO2, and NO2 levels were significantly higher than outdoor levels. The number of occupants and human activities such as cooking, smoking, etc. might be the factors affecting indoor pollutants whereas liquefied petroleum gas (LPG), not electric stoves, was the main cooking way in Kaohsiung City [28,29]. In addition, most of the houses were just by the roads and very close to the mobile sources in Kaohsiung City, which was thought of as a traffic-intensive city with the number of cars and motorcycles of approximately 430,000 and 1,230,000, respectively, in 2010 [30]. Thus, the main combustion products of vehicular engines such as CO, NOX, etc. entering the houses through cracks and windows might be the reason why the indoor concentrations of CO, CO2, and NO2 were higher than outdoor concentrations [15,16].
In comparison with traffic, industrial, and general areas, the highest household CO concentration was found in the traffic area among the three areas. According to the previous study, the greatest source of CO (more than 90%) in cities was motor vehicles [24]. The high traffic flow in the traffic area might be the reason for the observation. For CO2, our study indicated that the lowest household CO2 level was in the general area among the three areas. The main source of CO2 was from human respiration [24,31]. The number of residents might be one possible reason since the number of residents > 4 people in the traffic area, the industrial area, and general area were 40.40%, 57.01%, and 34.41%, respectively. We also found both household NO2 and O3 concentrations of the industrial area were lowest among the three areas, which was not consistent with the observations of previous studies that ambient NO2 was related to industrial activities [24], and outdoor O3 might be formed by the photochemical reaction of nitrogen oxides absorbing sunlight, and VOCs [25,26]. We believed these may be related to Taiwan EPA’ s policies and efforts to control air pollution from stationary sources after that the “Stationary Pollution Source Air Pollutant Emissions Standards” was passed in 1992, and the “Air Pollution Control Act Enforcement Rules” was also implemented in 2003.
In regard to the effects on the window opening, our study displayed that household NO2 and PM2.5 concentrations during window opening periods were significantly higher than that during reference periods. NOX and PM were related to traffic emissions [24,32], and most of the houses in Taiwan were adjacent to roads, so window opening might increase indoor NO2 and PM2.5. For the influence of cooking, there were many simulated experiments exploring the air pollutant emissions of cooking-related fuel combustion [29,33,34,35,36], and they demonstrated that CO, CO2, NOX, and PM2.5 would be emitted by the process of the experiments. Although CO also was produced by cooking, it was revealed that combustion of high-grade fuels (such as natural gas, and LPG which contained propane, butane, etc.), the main fuel-burning stoves use in Taiwan households usually produce much less CO than combustion of low-grade fuels [29,33]. In the previous study, Delp et al. revealed the residential cooking exhaust hoods could not completely capture the pollutants and their efficiency was highly variable [37]. Our results showed that indoor CO2, NO2, and PM2.5 levels during cooking periods were significantly higher than during reference periods, but the indoor CO level during cooking periods was lower than during reference periods, possibly indicating that the emission rate of CO2, NO2, and PM2.5 might be higher than the capture rate of the exhaust hood and the emission rate of CO might be lower than the pollutants capture rate of the exhaust hood.
In terms of influence factors, we found there were significantly positive correlations between the number of occupants and CO and CO2 concentrations. Our study was consistent with the observations of the previous study that CO2 was produced by human respiration [24,31]. In addition to the combustion, the indoor CO also was related to the status of residents; the previous studies revealed either a smoking person or person with inflammatory diseases exhaled higher CO levels than control group [38,39]. We also found smoking was significantly positively associated with household CO in our study. According to previous studies, smoking, incense burning, and mosquito coil burning were significantly positively associated with CO, CO2, SO2, NOX, and PM [40,41,42], and these results were consistent with our observation. The cleaning behavior would increase indoor PM2.5 and CO levels; it was consistent with the previous study that indoor PM2.5 and PM5 levels could be elevated by the cleaning behavior of dry dust, and vacuuming [43]. In addition, commercial cleansers and disinfectants contain VOCs [44], and El Fadel et al. found VOCs concentration was positively correlated with CO concentration [45]. We also revealed that air-conditioning use was positively associated with indoor CO2 concentrations with a statistical significance, which was consistent with a previous observation that CO2 levels were higher in mechanically ventilated buildings than in naturally ventilated buildings [46]. There was a significantly negative association between essential oil use and O3 concentration. The commercially available essential oils contain many VOCs (e.g., D-limonene, α- pinene, etc.) [47], in addition, a study displayed that indoor VOCs level had increased significantly after burning essential oils [48]. O3 was one of the indoor oxidants [49,50], and Waring et al. demonstrated that 68% of all O3 reactions were with D-limonene, and 26% of all O3 reactions are with α-pinene [50]. This might be the reason why the essential oil use could decrease the O3 level. Finally, by questionnaire, it was found that window opening was significantly correlated with increased O3 concentration, which was not consistent with the results from the time–microenvironment–activity-diary that only NO2 and PM2.5 levels during the window opening periods were significantly higher than that of reference periods. We believed O3 was a major component of photochemical pollution, so it is more relevant to outdoor sources than indoor sources. Thus, compared with the households which closed the windows, the households which opened the windows had a significantly higher 24-hour average concentration of O3. When comparing the window opening periods with the reference periods (two one-hour periods before and after window opening periods), there was no significant variation in atmospheric O3 concentration in a short time (within three hours). For PM2.5 and NOX levels, there was no significant difference between households which closed and opened the windows, the possible reason might be that PM2.5 and NOX could come from both indoor (cooking) and outdoor (traffic) sources.

5. Conclusions

This study explored the concentration of indoor air pollutants in different areas including traffic, industrial, and general areas within an industrial city. Moreover, this study also revealed household NO2 and PM2.5 concentrations during window opening periods were significantly higher than that of the reference periods with increased concentrations of 18.71 ppb, and 7 μg/m3, respectively. For the influence of cooking, indoor CO2, NO2, and PM2.5 levels during the cooking periods were significantly higher than that of the reference periods with increased concentrations of 26.17 ppm, 5.40 ppb, and 5 μg/m3, respectively.

Supplementary Materials

The following are available online at https://www.mdpi.com/2076-3417/9/20/4306/s1, Table S1: Descriptive statistics of 24-h average concentration of indoor air pollutants in the houses of traffic, industry, and general areas.

Author Contributions

Conceptualization, C.-Y.Y.; formal analysis, Y.-C.Y.; writing—original draft preparation, Y.-T.C. and Y.-T.C.; writing—review and editing, P.-S.C. and K.D.M.

Funding

This research was funded by “Wang Jhan-Yang Public Trust Fund”, grant number 108-002-6.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Idavain, J.; Julge, K.; Rebane, T.; Lang, A.; Orru, H. Respiratory symptoms, asthma and levels of fractional exhaled nitric oxide in schoolchildren in the industrial areas of Estonia. Sci. Total. Environ. 2019, 650, 65–72. [Google Scholar] [CrossRef] [PubMed]
  2. Martuzzi, M.; Pasetto, R.; Martin-Olmedo, P. Industrially Contaminated Sites and Health. J. Environ. Public Health 2014, 2014, 198574. [Google Scholar] [CrossRef] [PubMed]
  3. Kurt, O.K.; Zhang, J.; Pinkerton, K.E. Pulmonary health effects of air pollution. Curr. Opin. Pulm. Med. 2016, 22, 138–143. [Google Scholar] [CrossRef] [PubMed]
  4. Rice, M.B.; Rifas-Shiman, S.L.; Litonjua, A.A.; Oken, E.; Gillman, M.W.; Kloog, I.; Luttmann-Gibson, H.; Zanobetti, A.; Coull, B.A.; Schwartz, J.; et al. Lifetime Exposure to Ambient Pollution and Lung Function in Children. Am. J. Respir. Crit. Care Med. 2016, 193, 881–888. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  5. Deng, Q.; Lu, C.; Norbäck, D.; Bornehag, C.G.; Zhang, Y.; Liu, W.; Yuan, H.; Sundell, J. Early life exposure to ambient air pollution and childhood asthma in China. Environ. Res. 2015, 143, 83–92. [Google Scholar] [CrossRef] [PubMed]
  6. Marchetti, P.; Marcon, A.; Pesce, G.; Paolo, G.; Guarda, L.; Pironi, V.; Fracasso, M.E.; Ricci, P.; de Marco, R. Children living near chipboard and wood industries are at an increased risk of hospitalization for respiratory diseases: A prospective study. Int. J. Hyg. Environ. Health 2014, 217, 95–101. [Google Scholar] [CrossRef] [PubMed]
  7. Silvers, A.; Florence, B.T.; Rourke, D.L.; Lorimor, R.J. How Children Spend Their Time: A Sample Survey for Use in Exposure and Risk Assessments. Risk Anal. 1994, 14, 931–944. [Google Scholar] [CrossRef]
  8. Cannistraro, G.; Cannistraro, A.; Cannistraro, M.; Galvagno, A. Analysis of air pollution in the urban center of four cities sicilian. Int. J. Heat Technol. 2016, 34, S219–S225. [Google Scholar]
  9. Cannistraro, M.; Cannistraro, G.; Chao, J.; Ponterio, L. New Technique Monitoring and Transmission Environmental Data with Mobile. Instrum. Meas. Metrol. 2018, 18, 549–562. [Google Scholar] [CrossRef]
  10. Cannistraro, M.; Chao, J.; Ponterio, L. Experimental Study of Air Pollution in the Urban Centre of the City of Messina. Model. Meas. Control C 2018, 79, 133–139. [Google Scholar] [CrossRef]
  11. Leung, D.Y.C. Outdoor-indoor air pollution in urban environment: Challenges and opportunity. Front. Environ. Sci. 2015. [Google Scholar] [CrossRef]
  12. Brand, A.; McLean, K.E.; Henderson, S.B.; Fournier, M.; Liu, L.; Kosatsky, T.; Smargiassi, A. Respiratory hospital admissions in young children living near metal smelters, pulp mills and oil refineries in two Canadian provinces. Environ. Int. 2016, 94, 24–32. [Google Scholar] [CrossRef] [PubMed]
  13. Tian, L.; Zeng, Q.; Dong, W.; Guo, Q.; Wu, Z.; Pan, X.; Li, G.; Liu, Y. Addressing the source contribution of PM2.5on mortality: An evaluation study of its impacts on excess mortality in China. Environ. Res. Lett. 2017, 12, 104016. [Google Scholar] [CrossRef]
  14. Topacoglu, H.; Katsakoglou, S.; Ipekci, A. Effect of exhaust emissions on carbon monoxide levels in employees working at indoor car wash facilities. Hippokratia 2014, 18, 37–39. [Google Scholar] [PubMed]
  15. Srithawirat, T.; Latif, M.T.; Sulaiman, F.R. Indoor PM10 and Its Heavy Metal Composition at a Roadside Residential Environment; Atmosfera: Phitsanulok, Thailand, 2016; Volume 29, pp. 311–322. [Google Scholar]
  16. United States Environmental Protection Agency. Available online: https://www.epa.gov/report-environment/indoor-air-quality (accessed on 20 August 2019).
  17. World Health Organization. Household (Indoor) Air Pollution. 2014. Available online: https://www.who.int/indoorair/en/ (accessed on 20 August 2019).
  18. Han, I.; Guo, Y.; Afshar, M.; Symanski, E.; Stock, T.H. Comparison of trace elements in size-fractionated particles in two communities with contrasting socioeconomic status in Houston, TX. Environ. Monit. Assess. 2017, 189, 67. [Google Scholar] [CrossRef] [PubMed]
  19. Hart, J.E.; Garshick, E.; Dockery, D.W.; Smith, T.J.; Ryan, L.; Laden, F. Long-term ambient multipollutant exposures and mortality. Am. J. Respir. Crit. Care Med. 2011, 183, 73–78. [Google Scholar] [CrossRef] [PubMed]
  20. Milà, C.; Salmon, M.; Sanchez, M.; Ambrós, A.; Bhogadi, S.; Sreekanth, V.; Nieuwenhuijsen, M.; Kinra, S.; Marshall, J.D.; Tonne, C. When, Where, and What? Characterizing Personal PM2.5 Exposure in Periurban India by Integrating GPS, Wearable Camera, and Ambient and Personal Monitoring Data. Environ. Sci. Technol. 2018, 52, 13481–13490. [Google Scholar] [CrossRef]
  21. Pekey, B.; Bozkurt, Z.B.; Pekey, H.; Doğan, G.; Zararsız, A.; Efe, N.; Tuncel, G.; Zararsiz, A. Indoor/outdoor concentrations and elemental composition of PM10/PM2.5 in urban/industrial areas of Kocaeli City, Turkey. Indoor Air 2010, 20, 112–125. [Google Scholar] [CrossRef]
  22. Pekey, H.; Arslanba, D. The Relationship Between Indoor, Outdoor and Personal VOC Concentrations in Homes, Offices and Schools in the Metropolitan Region of Kocaeli, Turkey. Water Air Soil Pollut. 2008, 191, 113–129. [Google Scholar] [CrossRef]
  23. Liu, W.; Zhang, J.; Zhang, L.; Turpin, B.; Weisel, C.; Morandi, M.; Stock, T.; Colome, S.; Korn, L. Estimating contributions of indoor and outdoor sources to indoor carbonyl concentrations in three urban areas of the United States. Atmos. Environ. 2006, 40, 2202–2214. [Google Scholar] [CrossRef]
  24. Najjar, Y. Gaseous Pollutants Formation and Their Harmful Effects on Health and Environment. Innov. Energy Policies 2011, 1. [Google Scholar] [CrossRef]
  25. Du, X.; Liu, J. Relationship between outdoor and indoor ozone pollution concentration. Trans. Tianjin Univ. 2009, 15, 330–335. [Google Scholar] [CrossRef]
  26. Jianhui, B.; Singh, N.; Chauhan, S.; Singh, K.; Saud, T.; Saxena, M.; Soni, D.; Mandal, T.K.; Bassin, J.K.; Gupta, P.K. Study on surface O3 chemistry and photochemistry by UV energy conservation. Atmos. Pollut. Res. 2010, 1, 118–127. [Google Scholar] [CrossRef]
  27. Taiwan Environmental Protection Agency. Available online: https://taqm.epa.gov.tw/taqm/tw/PSIOver100MonthlyReport.aspx (accessed on 20 August 2019).
  28. Persily, A.; De Jonge, L. Carbon dioxide generation rates for building occupants. Indoor Air 2017, 27, 868–879. [Google Scholar] [CrossRef] [PubMed]
  29. Penney, D.; Benignus, V.; Kephalopoulos, S.; Kotzias, D.; Kleinman, M.; Verrier, A. WHO Guidelines for Indoor Air Quality: Selected Pollutants; WHO Regional Office for Europe: Denmark, 2010. [Google Scholar]
  30. Taiwan Environmental Protection Agency. Available online: https://erdb.epa.gov.tw/DataRepository/Statistics/StatSceAreapop.aspx (accessed on 20 August 2019).
  31. Satish, U.; Mendell, M.J.; Shekhar, K.; Hotchi, T.; Sullivan, D.; Streufert, S.; Fisk, W.J. Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance. Environ. Health Perspect. 2012, 120, 1671–1677. [Google Scholar] [CrossRef]
  32. Chao, H.-R.; Hsu, J.-W.; Ku, H.-Y.; Wang, S.-L.; Huang, H.-B.; Liou, S.-H.; Tsou, T.-C. Inflammatory Response and PM2.5 Exposure of Urban Traffic Conductors. Aerosol. Air Qual. Res. 2018, 18, 2633–2642. [Google Scholar] [CrossRef] [Green Version]
  33. Bilsback, K.R.; Dahlke, J.; Fedak, K.M.; Good, N.; Hecobian, A.; Herckes, P.; L’Orange, C.; Mehaffy, J.; Sullivan, A.; Tryner, J.; et al. A Laboratory Assessment of 120 Air Pollutant Emissions from Biomass and Fossil Fuel Cookstoves. Environ. Sci. Technol. 2019, 53, 7114–7125. [Google Scholar] [CrossRef]
  34. Shen, G.; Hays, M.D.; Smith, K.R.; Williams, C.; Faircloth, J.W.; Jetter, J.J. Evaluating the Performance of Household Liquefied Petroleum Gas Cookstoves. Environ. Sci. Technol. 2018, 52, 904–915. [Google Scholar] [CrossRef]
  35. Shen, G.; Gaddam, C.K.; Ebersviller, S.M.; Wal, R.L.V.; Williams, C.; Faircloth, J.W.; Jetter, J.J.; Hays, M.D. A Laboratory Comparison of Emission Factors, Number Size Distributions, and Morphology of Ultrafine Particles from 11 Different Household Cookstove-Fuel Systems. Environ. Sci. Technol. 2017, 51, 6522–6532. [Google Scholar] [CrossRef]
  36. Smith, K.R.; Uma, R.; Kishore, V.V.N.; Zhang, J.; Joshi, V.; Khalil, M.A.K. Greenhouse Implications of Household Stoves: An Analysis for India. Annu. Rev. Energy Environ. 2000, 25, 741–763. [Google Scholar] [CrossRef] [Green Version]
  37. Delp, W.W.; Singer, B.C. Performance Assessment of U.S. Residential Cooking Exhaust Hoods. Environ. Sci. Technol. 2012, 46, 6167–6173. [Google Scholar] [CrossRef] [PubMed]
  38. Deveci, S.E.; Deveci, F.; Açik, Y.; Ozan, A.T. The measurement of exhaled carbon monoxide in healthy smokers and non-smokers. Respir Med. 2004, 98, 551–556. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  39. Ryter, S.W.; Choi, A.M. Carbon monoxide in exhaled breath testing and therapeutics. J. Breath Res. 2013, 7, 017111. [Google Scholar] [CrossRef] [PubMed]
  40. Alberts, W.M. Indoor air pollution: NO, NO2, CO, and CO2. J. Allergy Clin. Immunol. 1994, 94, 289–295. [Google Scholar] [CrossRef] [PubMed]
  41. Lee, S.C.; Guo, H.; Kwok, N.H. Emissions of air pollutants from burning of incense by using large environmental chamber. In Proceedings of the Indoor Air 2002: 9th International Conference on Indoor Air Quality and Climate, Monterey, CA, USA, 30 June–5 July 2002; Volume 1. [Google Scholar]
  42. Lee, S.C.; Wang, B. Characteristics of emissions of air pollutants from mosquito coils and candles burning in a large environmental chamber. Atmos. Environ. 2006, 40, 2128–2138. [Google Scholar] [CrossRef]
  43. Ferro, A.R.; Kopperud, R.J.; Hildemann, L.M. Source Strengths for Indoor Human Activities that Resuspend Particulate Matter. Environ. Sci. Technol. 2004, 38, 1759–1764. [Google Scholar] [CrossRef]
  44. United States Environmental Protection Agency. Available online: https://www.epa.gov/indoor-air-quality-iaq/volatile-organic-compounds-impact-indoor-air-quality (accessed on 20 August 2019).
  45. El Fadel, M.; Alameddine, I.; Kazopoulo, M.; Hamdan, M.; Nasrallah, R. Carbon Monoxide and Volatile Organic Compounds as Indicators of Indoor Air Quality in Underground Parking Facilities. Indoor Built Environ. 2001, 10, 70–82. [Google Scholar] [CrossRef]
  46. Sribanurekha, V.; Wijerathne, S.N.; Wijepala, L.H.S.; Jayasinghe, C. Effect of Different Ventilation Conditions on Indoor CO2 Levels. In Proceedings of the International Conference on Disaster Resilience, At Kandalama, Sri Lanaka, 19–21 July 2011. [Google Scholar]
  47. Nematollahi, N.; Kolev, S.D.; Steinemann, A. Volatile chemical emissions from essential oils. Air Qual. Atmos. Heal. 2018, 11, 949–954. [Google Scholar] [CrossRef]
  48. Chao, C.J.; Wu, P.C.; Chang, H.Y.; Su, H.J. The effects of evaporating essential oils on indoor air quality. In Proceedings of the Indoor Air 2005, 10th International Conference on Indoor Air Quality and Climate, Beijing, China, 4–9 September 2005. [Google Scholar]
  49. Young, C.J.; Zhou, S.; Siegel, J.A.; Kahan, T.F. Illuminating the Dark Side of Indoor Oxidants. Environ. Sci. Process. Impacts 2019, 21, 1229–1239. [Google Scholar] [CrossRef]
  50. Waring, M.S.; Wells, J.R. Volatile organic compound conversion by ozone, hydroxyl radicals, and nitrate radicals in residential indoor air: Magnitudes and impacts of oxidant sources. Atmos. Environ. 2015, 106, 382–391. [Google Scholar] [CrossRef]
Figure 1. The 24-h average concentration of indoor air pollutants (A) CO, (B) CO2, (C) NO2, and (D) O3 in the houses of traffic, industry, and general areas. * Scheffe test p < 0.01.
Figure 1. The 24-h average concentration of indoor air pollutants (A) CO, (B) CO2, (C) NO2, and (D) O3 in the houses of traffic, industry, and general areas. * Scheffe test p < 0.01.
Applsci 09 04306 g001
Table 1. Descriptive statistics of 24-h average indoor and outdoor air pollutants, temperature, and relative humidity in 60 houses.
Table 1. Descriptive statistics of 24-h average indoor and outdoor air pollutants, temperature, and relative humidity in 60 houses.
MeanMedianStandard DeviationMinimumMaximump-Value #
CO (ppm)indoor3.470.834.290.0012.270.004
outdoor0.600.380.550.001.98
CO2 (ppm)indoor655.43479.55321.60413.821320.00<0.001
outdoor322.22319.9217.23285.83353.90
NO2 (ppb)indoor185.30177.9741.52127.28251.410.008
outdoor107.54118.2236.8339.90149.80
SO2 (ppm)indoor0.000.000.000.000.000.193
outdoor0.010.000.020.000.06
O3 (ppb)indoor11.048.508.931.0632.290.006
outdoor13.469.2012.340.2445.50
PM2.5 (μg/m3)indoor60.0040.0050.0010.00210.000.001
outdoor110.0090.0090.0030.00410.00
Temperature (°C)indoor31.0031.001.7626.0034.00-
Relative humidity (%)indoor72.0072.004.9862.0084.00-
# Paired Student’s t-test, p < 0.01.
Table 2. The percentage (%) of household characteristics in traffic, industry, and general areas.
Table 2. The percentage (%) of household characteristics in traffic, industry, and general areas.
Area
TrafficIndustryGeneral
Window opening68.7566.6787.50
Occupants (>4 people)40.4057.0134.41
Cooking87.5083.3395.83
Air-conditioning use62.5083.3395.83
Making tea31.2530.000
Smoker63.6440.0026.09
Incense burning72.7350.0029.17
Mosquito coil burning37.5022.2212.50
Essential oil using31.2533.3325.00
Table 3. The ratios of air pollutants during window opening periods to reference periods and the differences in air pollutants between window opening periods and reference periods.
Table 3. The ratios of air pollutants during window opening periods to reference periods and the differences in air pollutants between window opening periods and reference periods.
Ratios (Window Opening Periods/Reference Periods §)Differences (Window Opening Periods − Reference Periods §)p-Value #
MedianS.D.Min.Max.MedianS.D.Min.Max.
CO (ppm)0.981.340.574.440.001.31−2.423.670.53
CO2 (ppm)1.050.180.731.4329128−1412960.21
NO2 (ppb)1.561.300.945.2318.7116.05−9.4053.25<0.01
SO2 (ppm)0.000.920.003.270.000.020.000.080.21
O3 (ppb)1.180.590.562.190.814.44−11.9110.050.52
PM2.5 (μg/m3)1.130.310.691.85716.20−6440.04
# Paired Student’s t-test, p < 0.05, p < 0.01. § Reference periods were two one-hour periods before and after window opening periods.
Table 4. The ratios of air pollutants during cooking periods to reference periods and the differences in air pollutants between during cooking periods and reference periods.
Table 4. The ratios of air pollutants during cooking periods to reference periods and the differences in air pollutants between during cooking periods and reference periods.
Ratios (Cooking Periods/Reference Periods §)Differences (Cooking Periods − Reference Periods §)p-Value #
MedianS.D.Min.Max.MedianS.D.Min.Max.
CO (ppm)0.930.220.461.51−0.250.84−3.530.61<0.01
CO2 (ppm)1.060.140.851.5826.1790.21−111.67342.5<0.01
NO2 (ppb)1.110.980.515.435.4029.71−71.17101.75<0.01
O3 (ppb)1.080.690.464.360.278.89−35.1417.080.94
PM2.5 (μg/m3)1.090.300.602.56514−45560.04
# Paired Student’s t-test, p < 0.05, p < 0.01. § Reference periods were the one-hour period before cooking periods.
Table 5. Association between air pollutants concentrations (24-h average concentration of air pollutants in each house as dependent variable), and household characteristics: generalized estimating equations.
Table 5. Association between air pollutants concentrations (24-h average concentration of air pollutants in each house as dependent variable), and household characteristics: generalized estimating equations.
CO (ppm)CO2 (ppm)NO2 (ppb)SO2 (ppm)O3 (ppb)PM2.5 (μg/m3)
Window opening
(Yes vs. No)
0.3284.84−0.610.4424.34 −0.021
Occupants0.52 51.62 3.02−0.008−3.49 0.004
Cleaning
(Yes vs. No)
4.73 −317.491.390.43−6.240.047
Cooking
(Yes vs. No)
−3.89 228.02−28.01−0.211.790.065
Fan using
(Yes vs. No)
1.42−32.9710.58−0.0003−2.070.002
Air- conditioning use
(Yes vs. No)
−1.22246.99 87.870.2521.590.008
Making tea
(Yes vs. No)
37.04-−0.45−0.1314.21−0.050
Smoking
(Yes vs. No)
17.21 1988.44 547.36 2.98 1.690.173
Incense burning
(Yes vs. No)
18.21 2927.87 193.113.66 −108.9 0.416
Mosquito coil burning
(Yes vs. No)
41.55 −892.64 673.522.672.29-
Essential oil use
(Yes vs. No)
12.76269.2574.89−0.66−89.29 −0.022
Generalized estimating equations (GEE) p < 0.05, p < 0.01.

Share and Cite

MDPI and ACS Style

Yen, Y.-C.; Yang, C.-Y.; Mena, K.D.; Cheng, Y.-T.; Chen, P.-S. Cooking/Window Opening and Associated Increases of Indoor PM2.5 and NO2 Concentrations of Children’s Houses in Kaohsiung, Taiwan. Appl. Sci. 2019, 9, 4306. https://doi.org/10.3390/app9204306

AMA Style

Yen Y-C, Yang C-Y, Mena KD, Cheng Y-T, Chen P-S. Cooking/Window Opening and Associated Increases of Indoor PM2.5 and NO2 Concentrations of Children’s Houses in Kaohsiung, Taiwan. Applied Sciences. 2019; 9(20):4306. https://doi.org/10.3390/app9204306

Chicago/Turabian Style

Yen, Yu-Chuan, Chun-Yuh Yang, Kristina Dawn Mena, Yu-Ting Cheng, and Pei-Shih Chen. 2019. "Cooking/Window Opening and Associated Increases of Indoor PM2.5 and NO2 Concentrations of Children’s Houses in Kaohsiung, Taiwan" Applied Sciences 9, no. 20: 4306. https://doi.org/10.3390/app9204306

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop