Next Article in Journal
Processing of Single-Walled Carbon Nanotubes with Femtosecond Laser Pulses
Next Article in Special Issue
Precise Photon Correlation Measurement of a Chaotic Laser
Previous Article in Journal
Inflammation and Reduced Parasympathetic Cardiac Modulation in Aortic-Valve Sclerosis
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Communication

Quartz-Enhanced Photothermal-Acoustic Spectroscopy for Trace Gas Analysis

1
Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Department of Optoelectronic Engineering, Jinan University, Guangzhou 510632, China
2
State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy & Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan 030006, China
3
Key Laboratory of Optoelectronic Information and Sensing Technologies of Guangdong Higher Education Institutes, Jinan University, Guangzhou 510632, China
4
Guangdong Provincial Engineering Technology Research Center on Visible Light Communication and the Guangzhou Municipal Key Laboratory of Engineering Technology on Visible Light Communication, Jinan University, Guangzhou 510632, China
*
Authors to whom correspondence should be addressed.
Appl. Sci. 2019, 9(19), 4021; https://doi.org/10.3390/app9194021
Submission received: 3 August 2019 / Revised: 16 September 2019 / Accepted: 18 September 2019 / Published: 26 September 2019
(This article belongs to the Special Issue Quartz-Enhanced Photoacoustic and Photothermal Spectroscopy)

Abstract

:
A crystal quartz tuning fork (QTF) was used as a detector to collect and amplify laser-induced photoacoustic and photothermal waves simultaneously for trace chemical analysis. A wavelength modulation technique was applied to the proposed quartz-enhanced photothermal-acoustic spectroscopy (QEPTAS) to improve the detection signal-to-noise ratio. The QTF detector was exposed to the illumination of a near-infrared distributed feedback laser at distances of 1 m and 2 m to evaluate the QEPTAS sensor performance. The QEPTAS sensor performance was determined by detecting water vapor in ambient air using a near-infrared distributed feedback laser with a power of ~10 mW and a wavelength of 1.39 μm. With an optimized modulation depth of 0.47 cm−1, the normalized noise equivalent absorption (NNEA) coefficients of 8.4 × 10−7 W·cm−1·Hz−1/2 and 3.7 × 10−6 W·cm−1·Hz−1/2 were achieved for a distance of 1 m and 2 m, respectively. The developed QEPTAS technique reduces the requirements for laser beam quality, resulting in a simple but robust sensor structure and demonstrates the ability of remote sensing of gas concentrations.

1. Introduction

Photothermal spectroscopy (PTS) and photoacoustic spectroscopy (PAS) are well-established methods for experimental physics, chemistry, and biology. The history, processes, and application of PTS and PAS in gas phase analysis have previously been discussed in detail [1,2,3]. The photothermal and the photoacoustic effects can be divided into three stages: (1) release of heat due to the vibration–translation relaxation of molecules upon absorption of laser radiation; (2) generation of thermal and acoustic waves due to periodically heating and expansion; (3) collection and amplification of thermal and acoustic signals. According to the laws of fluid mechanics and thermodynamics, the laser-induced thermal and acoustic wave pressure p in a gas can be determined by Equation (1) [3]:
t 2 p ( r , t ) c 2 2 p ( r , t ) = ( σ 1 ) t H ( r , t ) ,
where c, σ, and H are the sound velocity, the adiabatic coefficient of the gas, and the heat density deposited in the gas, respectively. Equation (1) has two independent solutions: Weakly damped acoustic waves with the wavelength of approximately a few centimeters and heavily damped thermal waves with the waves of approximately a few hundred micrometers [3]. The acoustic waves propagated a few centimeters and accumulated in the PAS cells. However, the thermal waves can only be detected in the vicinity of the laser beam. Usually, PAS and PTS are studied independently since the thermal and acoustic waves are separated in space.
Photoacoustic spectroscopy is an optical detection method widely used for trace gas analysis. Transducers such as microphones [4,5,6], cantilevers [7,8,9,10], or piezoelectric elements [11,12,13] were used to detect acoustic waves and convert them into mechanical or electrical signals. As a significant variant of PAS, quartz-enhanced photoacoustic spectroscopy (QEPAS) has been boomingly developed in the past decades [14,15]. In QEPAS, a quartz tuning fork (QTF) with a specific resonance frequency of ~32 kHz and an extremely high Q factor value of ~10, 000 was used to collect the acoustic waves and accumulate the acoustic energy [16,17,18]. Because of the high resonance frequency of >10 kHz, the narrow resonance spectra of ~4 Hz, and the quadrupole electrode pattern of the QTF, QEPAS is immune to the background acoustic noise which results in a high detection signal-to-noise ratio and sensitivity [15]. The gas sensor based on the QEPAS technique has been applied for chemical analysis [19,20,21,22], atmospheric monitoring [23,24,25,26,27], and biological diagnostics [28,29,30].
As with photoacoustic spectroscopy, photothermal spectroscopy is an indirect method for measuring the change in the thermal states of the sample that is induced by the absorption of laser radiation. Examples of photothermal techniques include photothermal interferometry (PTI), photothermal lensing (PTL), and photothermal deflection (PTD). With the merits of zero-reference and laser power dependence, photothermal spectroscopy is highly sensitive. Traditional thermally sensitive transducers include pyroelectric crystals, bolometers, and microelectromechanical systems (MEMS). Most recently, a highly sensitive PTS technology called quartz-tuning-fork enhanced photothermal spectroscopy (QEPTS) was developed for trace gas analysis by use of a QTF [31]. A QTF was used as the high-performance transducer to convert the photothermal signals to electrical signals. The laser beam passed through a 20 cm-long gas-sampling cell and then was focused on the QTF prong. The heat released by the target molecules upon absorption of the laser radiation was collected by the QTF. The heat expansion drove the QTF to vibrate. Then the resonance of the QTF amplified the signal. In QEPAS, the laser beam must be collimated to pass through the spacing of ~300 µm without touching the QTF prongs. In QEPTS, the laser beam was focused on a spot with the diameter of ~36 µm, located in a particular area of the QTF prong where no silver layer was coated.
In this manuscript, quartz-enhanced photothermal-acoustic spectroscopy (QEPTAS) was developed for trace gas analysis. In QEPTAS, the laser beam illuminates the QTF prong spacing and the prong surface simultaneously. The excitation of a QTF consisted of two elements: Photoacoustic waves and photothermal waves. A commercially available 32 kHz QTF was used as a detector to collect and amplify the laser-induced acoustic waves and thermal waves simultaneously. There is no focus lens for laser beam shaping in QEPATS, thus simplifying the gas sensor structure. QEPATS removes the requirement for laser beam quality and provides the possibility of the remote sensing of gas concentrations.

2. Experiments and Results

The schematic diagram of the QEPTAS experimental setup is depicted in Figure 1. A 1.37 µm near-infrared fiber-coupled distributed feedback (DFB) diode laser was employed as the excitation source to detect water vapor (H2O) in ambient air. The temperature and current of the diode laser can be controlled by a high-stability laser diode controller (ILX Lightwave). A two-channel arbitrary waveform function generator (Tektronix AFG3102) was used to produce a ramp signal with the frequency of 10 mHz and a sine signal with the frequency of f0/2, where f0 corresponds to the resonance frequency of the QTF. The 2f wavelength modulation technique has the advantage of tunability and modulation capabilities of DFB lasers, improving the sensor performance [32]. The QTF was fixed on an XYZ linear stage and positioned in a cap, not shown in Figure 1. The acoustic and thermal waves induced by the laser radiation drove the QTF to vibrate. The electric signals generated by the piezoelectric effect in quartz was processed by a custom transimpedance preamplifier with a feedback resistance of 10 MΩ and then were fed to a lock-in amplifier (Standford SR830) to demodulate the signal in 2f mode. A Labview™ program was used to control the experimental system and retrieve the gas concentrations from the obtained 2f signal [24]. The experiment was conducted at a local atmospheric pressure of ~933 hPa (700 Torr) and room temperature of ~25 °C.
As proof of concept, a pigtailed laser diode with the beam M2 factor of 1.258 was used as the excitation source. Compared to previous publications on QEPAS and QEPTS, a non-focusing light source was firstly used in the experiment. The beam quality of the laser was analyzed by a dual scanning slit beam profiler (Thorlabs BP209-IR/M) with a beam diameter error <10%. The beam diameter as a function of laser head position is plotted in Figure 2. The distance between the laser head and the slit of the beam profiler changed from 5 mm to up to ~1 m. The laser temperature and injection current were set to 23 °C and 40 mA, respectively, corresponding to the emission power of 6.7 mW. When the position of the beam profiler was 955 mm, the beam diameter reached ~10 mm, corresponding to a beam spot about 100 times that used in the conventional QEPAS. The edge of the beam profile was defined as the position where the intensity fell to 1/e2 of the maximum value at the center.
In order to investigate the photothermal-acoustic response of the QTF surface to the laser beam, the normalized QEPTAS signal amplitude, as a function of x0, was researched. Figure 3a shows the diagram of QEPTAS. The QTF was fixed at the position of 150 µm from the laser head; y0 of the laser spot was set to 0.7 mm from the QTF opening; x0 of the laser spot was changed from 0 to 800 µm by use of an XYZ translation stage with the precision of 10 µm, as shown in Figure 3b. The prong length of the QTF, defined as the distance from the QTF opening to the x-axis, was measured to be ~3.6 mm. The prong spacing of the QTF was measured to be ~0.3 mm. The QTF prong width, defined as the distance from Line A to Line C, was measured to be ~0.6 mm. QEPTAS obtained the maximum signal amplitude when the laser spot was positioned at the center of the QTF prong spacing. When the position of the laser spot moved horizontally to the edge of the QTF prong (Line A), the signal amplitude decreased by ~23%. The minimum signal amplitude was obtained when the laser spot was positioned at the center of the QTF prong (Line B). For higher values, the signal amplitude increased to ~40% of the maximum value at Line C. The signal variation is related to the electrode layer pattern on the QTF surface. Most of the area of the QTF prong is coated with a silver layer, which has a high reflectivity for the laser beam [31]. There was no coating In the vicinity of Line A and Line C, which means that more photons were absorbed by the QTF, resulting in a higher signal amplitude. The subsequent decrease beyond Line C was due to the decrease of photothermal effects on the QTF surface.
In order to determine the optimum laser excitation of the QEPTAS system, the laser wavelength modulation depth was varied from 0.2 cm−1 to 0.65 cm−1 to obtain a maximum 2f QEPTAS signal amplitude. The experimental results shown in Figure 4 illustrate the influence of the laser modulation depth on the QEPTAS signal. In the wavelength modulation, the theoretical modulation index m, defined as the ratio between the modulation depth and the half width at half maximum of the absorption profile, was ~2.2, violating the hypothesis of the Taylor series expansions [33]. However, the optimal modulation depth to achieve the maximum signal needs to be optimized experimentally. The signal amplitude increased monotonically with the laser modulation depth and, for values higher than 0.47 cm−1, the signal amplitude increased only by <1%. The 2f signal amplitude started to decrease when the modulation depth was larger than 0.55 cm−1. Therefore, the optimum laser modulation depth was ~0.47 cm−1.
The performance of the QEPTAS sensor was evaluated by detecting H2O in ambient air. The QEPTAS acoustic detection module (ADM) was positioned at distances of 1 m and 2 m from the laser head. The emission wavelength of the laser was tuned from 7306.31 cm−1 to 7308.01 cm−1 to target the H2O absorption line at 7306.75 cm−1, with a line intensity of 1.8 × 10−20 cm/molecule. Figure 5 shows the QEPTAS signal amplitude of 1.25 × 10−3 V and 2.4 × 10−4 V, corresponding to the QEPTAS ADM distances of 1 m and 2 m, respectively. The 1σ noise was obtained by changing the laser injection current to tune the emission wavelength away from the H2O absorption line. The calculated 1σ standard deviation for distances of 1 m and 2 m were 1.19 µV and 1.02 µV, respectively. The ambient H2O concentration of 1.3% was determined by direct absorption spectroscopy [34]. For Figure 5, the measurement took ~5 min.
The calculation of the normalized noise equivalent absorption (NNEA) coefficient is given by Equation (2):
N N E A = a m i n P 0 Δ f ,
where amin, p0, and Δf are the minimum detectable absorption coefficient at an SNR = 1, the laser optical power, and the equivalent noise detection bandwidth, respectively [35]. The detection limits for H2O obtained by the QEPTAS sensor at distances of 1 m and 2 m were ~12 ppm and ~55 ppm, corresponding to a NNEA coefficients of 8.4 × 10−7 W·cm−1·Hz−1/2 and 3.7 × 10−6 W·cm−1·Hz−1/2, respectively. Compared to other photothermal spectroscopy techniques based on a silicon resonator [36] or a fiber-coupled Fabry–Pérot interferometer [37], the NNEA of QEPTAS is competitive. Yufei Ma et al. give a brief qualitative description of the analysis of photothermal effects [31]. The detailed theoretical analysis can be obtained from a theoretical model for resonant optothermoacoustic systems [38].

3. Conclusions

The proposed QEPTAS is a useful tool for the investigation of photoacoustic and photothermal effects simultaneously. The commercially available QTF acted as a highly sensitive detector to collect the acoustic and thermal waves upon the absorption of laser radiation by target molecules. The remote sensing ability of the QEPTAS sensor was demonstrated by detecting H2O in ambient air. The feature of non-contact detection and the lack of laser beam shaping components of the QEPTAS sensor introduced a better error tolerance than that of QEPAS and QEPTS in sensor assembling. The QEPTAS sensor shows great potential for application in the recently developed room-temperature continuous terahertz quantum cascade lasers [39,40], which are not easily used in QEPAS or QEPTS, since in QEPAS and QEPTS, the focused laser spot diameter d is limited by the diffraction limit d = λ/2 × NA, where NA represents the numerical aperture. The wavelength λ can be up to centimeters. The advantage of QTF is that the overall size of a typical sensor platform can be significantly reduced to a size that is suitable for applications requiring lightweight and compact structures, such as balloons or unmanned aerial vehicles (UAV) [41]. Further improvement can be made by utilizing custom tuning forks made of materials with higher piezoelectric and thermoelectric coefficients than a commercial quartz tuning fork.

Author Contributions

H.Z. and L.D. (Lei Dong), methodology; L.D. (Linpeng Dong), software, H.L., validation; Z.H., formal analysis; H.Z., investigation and data curation; X.G., writing—original draft preparation; H.Z., writing—review and editing; L.D. (Lei Dong), supervision; J.Y., project administration; J.T., L.D. (Linpeng Dong) and W.Z., funding acquisition; H.Z., J.Y. and Z.C.

Funding

This work is supported by the National Natural Science Foundation of China (11004086, 61675092, 61275046, 61475066, 61405075, 61601404), Natural Science Foundation of Guangdong Province (2016A030313079, 2016A030310098, 2016A030311019, 2014A030313377, 2015A030306046, 2015A030313320), Special Funds for Major Science and Technology Projects of Guangdong Province (2019B010138004, 2014B010120002, 2014B010117002, 2015B010125007), Project of Guangzhou Industry Leading Talents (CXLJTD-201607), and Planned Science & Technology Project of Guangzhou (2017A010102006, 2016A010101017, 2016B010111003, 201506010046), Joint fund of pre-research for equipment, Ministry of Education of China (6141A02022124), Aeronautical Science Foundation of China (201708W4001); Foundation for Distinguished Young Talents in Higher Education of Guangdong (2018KQNCX009, 2018KQNCX279), the Fundamental Research Funds for the Central Universities (21619402), State Key Laboratory of Applied Optics (SKLAO-201914).

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Bailey, R.T.; Bernegger, S.; Bicanic, D.; Bijnen, F.; Blom, C.W.P.M.; Cruickshank, F.R.; Diebold, G.J.; Fiedler, M.; Harren, F.; Hess, P.; et al. Photoacoustic, Photothermal and Photochemical Processes in Gases; Springer: Berlin/Heidelberg, Germany, 1989; pp. 1–252. [Google Scholar]
  2. Coufal, H.; McClelland, J.F. Photothermal and photoacoustic spectroscopy. J. Mol. Struct. 1988, 173, 129–140. [Google Scholar] [CrossRef]
  3. Miklós, A.; Hess, P.; Bozóki, Z. Application of acoustic resonators in photoacoustic trace gas analysis and metrology. Rev. Sci. Instrum. 2001, 72, 1937–1955. [Google Scholar] [CrossRef] [Green Version]
  4. Kottmann, J.; Rey, J.M.; Sigrist, M.W. Mid-Infrared photoacoustic detection of glucose in human skin: Towards non-invasive diagnostics. Sensors 2016, 16, 1663. [Google Scholar] [CrossRef] [PubMed]
  5. Zoltán, B.; Pogány, A.; Szabó, G. Photoacoustic instruments for practical applications: Present, potentials, and future challenges. Appl. Spectrosc. Rev. 2001, 46, 1–37. [Google Scholar]
  6. Bauer, R.; Stewart, G.; Johnstone, W.; Boyd, E.; Lengden, M. 3D-printed miniature gas cell for photoacoustic spectroscopy of trace gases. Opt. Lett. 2014, 39, 4796–4799. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  7. Hirschmann, C.B.; Lehtinen, J.; Uotila, J.; Ojala, S.; Keiski, R.L. Sub-ppb detection of formaldehyde with cantilever enhanced photoacoustic spectroscopy using quantum cascade laser source. Appl. Phys. B 2013, 111, 603–610. [Google Scholar] [CrossRef]
  8. Adamson, B.D.; Sader, J.E.; Bieske, E.J. Photoacoustic detection of gases using microcantilevers. J. Appl. Phys. 2009, 106, 114510. [Google Scholar] [CrossRef] [Green Version]
  9. Khan, D.; Bayram, F.; Gajula, D.; Talukdar, A.; Li, H.; Koley, G. Plasmonic amplification of photoacoustic waves detected using piezotransistive GaN microcantilevers. Appl. Phys. Lett. 2017, 111, 062102. [Google Scholar] [CrossRef]
  10. Gong, Z.; Chen, K.; Yang, Y.; Zhou, X.; Peng, W.; Yu, Q. High-sensitivity fiber-optic acoustic sensor for photoacoustic spectroscopy based traces gas detection. Sens. Actuators B Chem. 2017, 247, 290–295. [Google Scholar] [CrossRef]
  11. Van Neste, C.W.; Senesac, L.R.; Thundat, T. Standoff photoacoustic spectroscopy. Appl. Phys. Lett. 2008, 92, 234102. [Google Scholar] [CrossRef]
  12. Ngai, A.K.Y.; Persijn, S.T.; Lindsay, I.D.; Kosterev, A.A.; Groß, P.; Lee, C.J.; Cristescu, S.M.; Tittel, F.K.; Boller, K.-J.; Harren, F.J.M. Continuous wave optical parametric oscillator for quartz-enhanced photoacoustic trace gas sensing. Appl. Phys. B 2007, 89, 123. [Google Scholar] [CrossRef]
  13. Liu, K.; Cao, Y.; Wang, G.; Zhang, W.; Chen, W.; Gao, X. A novel photoacoustic spectroscopy gas sensor using a low cost polyvinylidene fluoride film. Sens. Actuators B Chem. 2018, 277, 571–575. [Google Scholar] [CrossRef]
  14. Kosterev, A.A.; Bakhirkin, Y.A.; Curl, R.F.; Tittel, F.K. Quartz-enhanced photoacoustic spectroscopy. Opt. Lett. 2002, 27, 1902–1904. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  15. Patimisco, P.; Sampaolo, A.; Dong, L.; Tittel, F.K.; Spagnolo, V. Recent advances in quartz enhanced photoacoustic sensing. Appl. Phys. Rev. 2018, 5, 011106. [Google Scholar] [CrossRef]
  16. Wu, H.; Dong, L.; Zheng, H.; Yu, Y.; Ma, W.; Zhang, L.; Yin, W.; Xiao, L.; Jia, S.; Tittel, F.K. Beat frequency quartz-enhanced photoacoustic spectroscopy for fast and calibration-free continuous trace-gas monitoring. Nat. Commun. 2017, 8, 15331. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  17. Ma, Y.; Lewicki, R.; Razeghi, M.; Tittel, F.K. QEPAS based ppb-level detection of CO and N2O using a high power CW DFB-QCL. Opt. Express 2013, 21, 1008–1019. [Google Scholar] [CrossRef] [PubMed]
  18. Dong, L.; Kosterev, A.A.; Thomazy, D.; Tittel, F.K. QEPAS spectrophones: Design, optimization, and performance. Appl. Phys. B 2010, 100, 627–635. [Google Scholar] [CrossRef]
  19. Wysocki, G.; Kosterev, A.A.; Tittel, F.K. Influence of molecular relaxation dynamics on quartz-enhanced photoacoustic detection of CO 2 at λ = 2 μm. Appl. Phys. B 2006, 85, 301–306. [Google Scholar] [CrossRef]
  20. Wang, Z.; Geng, J.; Ren, W. Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) Detection of the ν7 Band of Ethylene at Low Pressure with CO2 Interference Analysis. Appl. Spectrosc. 2017, 71, 1834–1841. [Google Scholar] [CrossRef]
  21. Giglio, M.; Patimisco, P.; Sampaolo, A.; Zifarelli, A.; Blanchard, R.; Pfluegl, C.; Witinski, M.F.; Vakhshoori, D.; Tittel, F.K.; Spagnolo, V. Nitrous oxide quartz-enhanced photoacoustic detection employing a broadband distributed-feedback quantum cascade laser array. Appl. Phys. Lett. 2018, 113, 171101. [Google Scholar] [CrossRef] [Green Version]
  22. Spagnolo, V.; Dong, L.; Kosterev, A.A.; Tittel, F.K. Modulation cancellation method for isotope 18O/16O ratio measurements in water. Opt. Express 2012, 20, 3401–3407. [Google Scholar] [CrossRef] [PubMed]
  23. Yi, H.; Maamary, R.; Gao, X.; Sigrist, M.W.; Fertein, E.; Chen, W. Short-lived species detection of nitrous acid by external-cavity quantum cascade laser based quartz-enhanced photoacoustic absorption spectroscopy. Appl. Phys. Lett. 2015, 106, 101109. [Google Scholar] [CrossRef]
  24. Zheng, H.; Dong, L.; Yin, X.; Liu, X.; Wu, H.; Zhang, L.; Ma, W.; Yin, W.; Jia, S. Ppb-level QEPAS NO2 sensor by use of electrical modulation cancellation method with a high power blue LED. Sens. Actuators B Chem. 2015, 208, 173–179. [Google Scholar] [CrossRef]
  25. Wu, H.; Dong, L.; Yin, X.; Sampaolo, A.; Patimisco, P.; Ma, W.; Zhang, L.; Yin, W.; Xiao, L.; Spagnolo, V.; et al. Atmospheric CH4 measurement near a landfill using an ICL-based QEPAS sensor with VT relaxation self-calibration. Sens. Actuators B Chem. 2019, 297, 126753. [Google Scholar] [CrossRef]
  26. Rück, T.; Bierl, R.; Matysik, F.M. NO2 trace gas monitoring in air using off-beam quartz enhanced photoacoustic spectroscopy (QEPAS) and interference studies towards CO2, H2O and acoustic noise. Sens. Actuators B Chem. 2018, 255, 2462–2471. [Google Scholar] [CrossRef]
  27. Jahjah, M.; Jiang, W.; Sanchez, N.P.; Ren, W.; Patimisco, P.; Spagnolo, V.; Herndon, S.C.; Griffin, R.J.; Tittel, F.K. Atmospheric CH4 and N2O measurements near Greater Houston area landfills using a QCL-based QEPAS sensor system during DISCOVER-AQ 2013. Opt. Lett. 2014, 39, 957–960. [Google Scholar] [CrossRef] [PubMed]
  28. Köhring, M.; Böttger, S.; Willer, U.; Schade, W. LED-absorption-QEPAS sensor for biogas plants. Sensors 2015, 15, 12092–12102. [Google Scholar] [CrossRef] [PubMed]
  29. Nguyen Ba, T.; Triki, M.; Desbrosses, G.; Vicet, A. Quartz-enhanced photoacoustic spectroscopy sensor for ethylene detection with a 3.32 μm distributed feedback laser diode. Rev. Sci. Instrum. 2015, 86, 023111. [Google Scholar] [CrossRef]
  30. Wang, Z.; Li, Z.; Ren, W. Quartz-enhanced photoacoustic detection of ethylene using a 10.5 μm quantum cascade laser. Opt. Express 2016, 24, 4143–4154. [Google Scholar] [CrossRef]
  31. Ma, Y.; He, Y.; Tong, Y.; Yu, X.; Tittel, F.K. Quartz-tuning-fork enhanced photothermal spectroscopy for ultra-high sensitive trace gas detection. Opt. Express 2018, 26, 32103–32110. [Google Scholar] [CrossRef] [Green Version]
  32. Schilt, S.; Thevenaz, L.; Robert, P. Wavelength modulation spectroscopy: Combined frequency and intensity laser modulation. Appl. Opt. 2003, 42, 6728–6738. [Google Scholar] [CrossRef] [PubMed]
  33. Patimisco, P.; Sampaolo, A.; Bidaux, Y.; Bismuto, A.; Scott, M.; Jiang, J.; Muller, A.; Faist, J.; Tittel, F.K.; Spagnolo, V. Purely wavelength-and amplitude-modulated quartz-enhanced photoacoustic spectroscopy. Opt. Express 2016, 24, 25943–25954. [Google Scholar] [CrossRef] [PubMed]
  34. Yin, X.; Dong, L.; Zheng, H.; Liu, X.; Wu, H.; Yang, Y.; Ma, W.; Zhang, L.; Yin, W.; Xiao, L.; et al. Impact of humidity on quartz-enhanced photoacoustic spectroscopy based CO detection using a near-IR telecommunication diode laser. Sensors 2016, 16, 162. [Google Scholar] [CrossRef] [PubMed]
  35. Elia, A.; Di Franco, C.; Spagnolo, V.; Lugarà, P.M.; Scamarcio, G. Quantum cascade laser-based photoacoustic sensor for trace detection of formaldehyde gas. Sensors 2009, 9, 2697–2705. [Google Scholar] [CrossRef] [PubMed]
  36. Vasiliev, A.; Malik, A.; Muneeb, M.; Kuyken, B.; Baets, R.; Roelkens, G. On-chip mid-infrared photothermal spectroscopy using suspended silicon-on-insulator microring resonators. ACS Sens. 2016, 1, 1301–1307. [Google Scholar] [CrossRef]
  37. Breitegger, P.; Lang, B.; Bergmann, A. Intensity modulated photothermal measurements of NO2 with a compact fiber-coupled Fabry–Pérot interferometer. Sensors 2019, 19, 3341. [Google Scholar] [CrossRef]
  38. Petra, N.; Zweck, J.; Minkoff, S.E.; Kosterev, A.A.; Doty, J.H., III. Modeling and design optimization of a resonant optothermoacoustic trace gas sensor. SIAM J. Appl. Math. 2011, 71, 309–332. [Google Scholar] [CrossRef]
  39. Patimisco, P.; Sampaolo, A.; Zheng, H.; Dong, L.; Tittel, F.K.; Spagnolo, V. Quartz–enhanced photoacoustic spectrophones exploiting custom tuning forks: A review. Adv. Phys. X 2017, 2, 169–187. [Google Scholar] [CrossRef]
  40. Jung, S.; Jiang, A.; Jiang, Y.; Vijayraghavan, K.; Wang, X.; Troccoli, M.; Belkin, M.A. Broadly tunable monolithic room-temperature terahertz quantum cascade laser sources. Nat. Commun. 2014, 5, 4267. [Google Scholar] [CrossRef] [Green Version]
  41. Ma, Y. Review of recent advances in QEPAS-based trace gas sensing. Appl. Sci. 2018, 8, 1822. [Google Scholar] [CrossRef]
Figure 1. Experimental setup of quartz-enhanced photothermal-acoustic spectroscopy. ∑: Adder, PC: Personal computer, Preamp: Pre-amplifier; QTF: Quartz tuning fork. RS232: A standard protocol used for serial communication.
Figure 1. Experimental setup of quartz-enhanced photothermal-acoustic spectroscopy. ∑: Adder, PC: Personal computer, Preamp: Pre-amplifier; QTF: Quartz tuning fork. RS232: A standard protocol used for serial communication.
Applsci 09 04021 g001
Figure 2. Laser beam quality analysis at a distance of up to 1 m. The beam diameter error of 10% was determined by the beam profiler.
Figure 2. Laser beam quality analysis at a distance of up to 1 m. The beam diameter error of 10% was determined by the beam profiler.
Applsci 09 04021 g002
Figure 3. (a) Diagram of quartz-enhanced photothermal-acoustic spectroscopy. (b) Lines A, B, C represent the edges and central line of the QTF prong, respectively. The values of x0 and y0 represent the distance between the laser-spot center and the QTF y-axis and x-axis, respectively. (c) The normalized quartz-enhanced photothermal-acoustic spectroscopy (QEPTAS) signal amplitude as a function of laser spot position, x0. The error of amplitude was less than 1%.
Figure 3. (a) Diagram of quartz-enhanced photothermal-acoustic spectroscopy. (b) Lines A, B, C represent the edges and central line of the QTF prong, respectively. The values of x0 and y0 represent the distance between the laser-spot center and the QTF y-axis and x-axis, respectively. (c) The normalized quartz-enhanced photothermal-acoustic spectroscopy (QEPTAS) signal amplitude as a function of laser spot position, x0. The error of amplitude was less than 1%.
Applsci 09 04021 g003
Figure 4. Optimization of laser modulation depth.
Figure 4. Optimization of laser modulation depth.
Applsci 09 04021 g004
Figure 5. Optimized QEPTAS 2f signal obtained at distances of 1 m and 2 m.
Figure 5. Optimized QEPTAS 2f signal obtained at distances of 1 m and 2 m.
Applsci 09 04021 g005

Share and Cite

MDPI and ACS Style

Zheng, H.; Lin, H.; Dong, L.; Huang, Z.; Gu, X.; Tang, J.; Dong, L.; Zhu, W.; Yu, J.; Chen, Z. Quartz-Enhanced Photothermal-Acoustic Spectroscopy for Trace Gas Analysis. Appl. Sci. 2019, 9, 4021. https://doi.org/10.3390/app9194021

AMA Style

Zheng H, Lin H, Dong L, Huang Z, Gu X, Tang J, Dong L, Zhu W, Yu J, Chen Z. Quartz-Enhanced Photothermal-Acoustic Spectroscopy for Trace Gas Analysis. Applied Sciences. 2019; 9(19):4021. https://doi.org/10.3390/app9194021

Chicago/Turabian Style

Zheng, Huadan, Haoyang Lin, Lei Dong, Zhao Huang, Xiaohang Gu, Jieyuan Tang, Linpeng Dong, Wenguo Zhu, Jianhui Yu, and Zhe Chen. 2019. "Quartz-Enhanced Photothermal-Acoustic Spectroscopy for Trace Gas Analysis" Applied Sciences 9, no. 19: 4021. https://doi.org/10.3390/app9194021

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop