Next Article in Journal
One-Step Fabrication of Nickel-Electrochemically Reduced Graphene Oxide Nanocomposites Modified Electrodes and Application to the Detection of Sunset Yellow in Drinks
Previous Article in Journal
Identification of Novel Molecular Targets of Four Microcystin Variants by High-Throughput Virtual Screening
Previous Article in Special Issue
Quartz Enhanced Conductance Spectroscopy for Polymer Nano-Mechanical Thermal Analysis
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Editorial

Quartz-Enhanced Photoacoustic and Photothermal Spectroscopy

1
State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan 030006, China
2
PolySense Lab-Dipartimento Interateneo di Fisica, Politecnico and University of Bari, CNR–IFN, Via Amendola 173, 70126 Bari, Italy
*
Authors to whom correspondence should be addressed.
Appl. Sci. 2022, 12(5), 2613; https://doi.org/10.3390/app12052613
Submission received: 3 November 2020 / Accepted: 22 February 2022 / Published: 3 March 2022
(This article belongs to the Special Issue Quartz-Enhanced Photoacoustic and Photothermal Spectroscopy)

1. Introduction

The development of innovative gas-sensing systems is fundamental in diverse research fields such as physics, chemistry, biology, medicine and environmental science [1,2,3]. Sensors based on quartz-enhanced photoacoustic spectroscopy [4,5] or photothermal spectroscopy [6,7] have the merit of combining high spectral selectivity provided by laser sources, high sensitivity guaranteed by sharply resonant quartz tuning forks (QTF), and a field-proven level of robustness and compactness. These characteristics—together with the no-cost impact of QTFs employed as sound and/or light detectors, and their capability of efficiently working in harsh environments—make sensors relying on tuning forks the leading-edge technologies for in-situ and real-time detection of gas species [8,9]. Hence, we dedicated a Special Issue to the most recent advances and state-of-the-art applications of quartz-enhanced photoacoustic and photothermal spectroscopy. A total of 15 paper submissions were received. Among them, one manuscript was rejected by the editor in the initial checking process, and two manuscripts were rejected by the reviewers. The remaining manuscripts underwent a peer-reviewing process and were evaluated by at least two reviewers widely acknowledged as experts in their research. Finally, 11 manuscripts were accepted for publication in Applied Sciences—Basel. We would like to sincerely thank for their effort these numerous reviewers from across the world—in particular, from China, the USA, Italy and Germany—who contributed to the high quality and success of this Special Issue.

2. Main Content of the Special Issue

The recent advances in, and development of, custom quartz tuning forks and laser sources, as well as narrowband laser absorbers, has opened up new opportunities for gas sensing and detection techniques based on quartz-enhanced photoacoustic spectroscopy (QEPAS) and/or quartz-enhanced photothermal spectroscopy (QEPTS). Therefore, the research papers published in this Special Issue mainly focus on novel approaches exploiting QTFs as core sensitive elements, and their implementation in real world applications.
In particular, three articles of the Special Issue investigate and exploit the photothermal effect. The first article, authored by S. Li et al. presents a non-destructive method to analyze the thermodynamics of polymer microwire samples, bridged across the prongs of the tuning fork, at the nanogram level [10]. Compared with the traditional method, the analysis method exposed in this paper does not require annealing before measurement, which is an essential process for conventional thermal analysis, and results in a fast analysis time. The second article, submitted by H. Zheng et al., reports on an original approach for trace-gas detection, by combining photo-thermal and photo-acoustic spectroscopy, and relying on a quartz tuning fork as a light-intensity and sound-wave detector, simultaneously [11]. In the third article, authored by G. Lan et al., a narrowband perfect absorber based on a dielectric-metal metasurface for wide-band surface-enhanced infrared sensing was investigated. This study offers a promising approach to designing high-performance surface-enhanced resonators to be employed as optical detectors in the infrared region [12].
Two manuscripts were dedicated to the design, development and optimization of high-performance electronics devoted to the QTF piezo-current transduction in a voltage signal. Piotr Z. Wieczorek et al. analyzed the influence of the crucial parameters of the low-noise operational preamplifier design, and discussed the characteristics of transimpedance and voltage configurations [13]. G. Menduni et al. investigated the possibility of using a differential input/output configuration with respect to single-ended configuration, and discussed the related signal-to-noise ratios in QEPAS spectra obtained by means of a water vapor sensor [14]. Two more articles focus on the physical interaction between the target analyte excited and the gas matrix. The manuscript authored by J. Hayden et al. explains the peculiar trend of carbon monoxide QEPAS signals in a nitrogen-based gas matrix, obtained by changing the water vapor concentration. The kinetic model, discussed in detail, can be used to identify optimized experimental conditions for sensing CO, and can be readily adapted to include further collision partners [15]. The effects of gas-matrix variations are also addressed in the article authored by M. Mordmueller et al., who reported on the latest results obtained with an auto-triggered QEPAS approach. This configuration works without external frequency generators, and ensures permanent locking to the current resonance frequency of the tuning fork [16]. The phase-optimized photoacoustic technique mentioned above avoids a calibration procedure and permits the continuous monitoring of a targeted trace gas. The remaining three papers all focus on optimized configurations of the laser beam shape and improved acoustic detection modules, mounting custom QTFs to further enhance the sensitivity of QEPAS-based sensors [17,18,19]. These new results set the basis for a further twist in the development of technology, to more efficiently address the challenges provided by the sensor market and environmental monitoring applications.

Author Contributions

H.W. and A.S. contributed equally to this work. All authors have read and agreed to the published version of the manuscript.

Funding

National Natural Science Foundation of China (No. 62075119 and 62122045).

Acknowledgments

We would like to sincerely thank our Contact Editor, Enoch Li, for all the efforts he has made for this Special Issue.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Hodgkinson, J.; Tatam, R.P. Optical gas sensing: A review. Meas. Sci. Technol. 2012, 24, 012004. [Google Scholar] [CrossRef] [Green Version]
  2. Patimisco, P.; Sampaolo, A.; Dong, L.; Tittel, F.K.; Spagnolo, V. Recent advances in quartz enhanced photoacoustic sensing. Phys. Rev. Lett. 2018, 5, 011106. [Google Scholar] [CrossRef]
  3. Wu, H.; Dong, L.; Zheng, H.; Yu, Y.; Ma, W.; Zhang, L.; Yin, W.; Xiao, L.; Jia, S.; Tittel, F.K. Beat frequency quartz-enhanced photoacoustic spectroscopy for fast and calibration-free continuous trace-gas monitoring. Nat. Commun. 2017, 8, 15331. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Dong, L.; Kosterev, A.A.; Thomazy, D.; Tittel, F.K. QEPAS spectrophones: Design, optimization, and performance. Appl. Phys. B 2010, 100, 627–635. [Google Scholar] [CrossRef]
  5. Giglio, M.; Zifarelli, A.; Sampaolo, A.; Menduni, G.; Elefante, A.; Blanchard, R.; Pfluegl, C.; Witinski, M.F.; Vakhshoori, D.; Wu, H.; et al. Broadband detection of methane and nitrous oxide using a distributed-feedback quantum cascade laser array and quartz-enhanced photoacoustic sensing. Photoacoustics 2020, 17, 100159. [Google Scholar] [CrossRef] [PubMed]
  6. Russo, S.D.; Zifarelli, A.; Patimisco, P.; Sampaolo, A.; Wei, T.; Wu, H.; Dong, L.; Spagnolo, V. Light-induced thermo-elastic effect in quartz tuning forks exploited as a photodetector in gas absorption spectroscopy. Opt. Express 2020, 28, 19074–19084. [Google Scholar] [CrossRef] [PubMed]
  7. Ma, Y.; He, Y.; Patimisco, P.; Sampaolo, A.; Qiao, S.; Yu, X.; Tittel, F.K.; Spagnolo, V. Ultra-high sensitive trace gas detection based on light-induced thermoelastic spectroscopy and a custom quartz tuning fork. Appl. Phys. Lett. 2020, 116, 011103. [Google Scholar] [CrossRef]
  8. Sampaolo, A.; Menduni, G.; Patimisco, P.; Giglio, M.; Passaro, V.M.; Dong, L.; Wu, H.; Tittel, F.K.; Spagnolo, V. Quartz-enhanced photoacoustic spectroscopy for hydrocarbon trace gas detection and petroleum exploration. Fuel 2020, 277, 118118. [Google Scholar] [CrossRef]
  9. Wu, H.; Dong, L.; Yin, X.; Sampaolo, A.; Patimisco, P.; Ma, W.; Zhang, L.; Yin, W.; Xiao, L.; Spagnolo, V.; et al. Atmospheric CH4 measurement near a landfill using an ICL-based QEPAS sensor with V-T relaxation self-calibration. Sens. Actuators Chem. 2019, 297, 126753. [Google Scholar] [CrossRef]
  10. Li, S.; Sun, B.; Shang, Z.; Li, B.; Cui, R.; Wu, H.; Dong, L. Quartz Enhanced Conductance Spectroscopy for polymer nano-mechanical thermal analysis. Appl. Sci. 2020, 10, 4954. [Google Scholar] [CrossRef]
  11. Zheng, H.; Lin, H.; Dong, L.; Huang, Z.; Gu, X.; Tang, J.; Dong, L.; Zhu, W.; Yu, J.; Chen, Z. Quartz-enhanced photo-thermal-acoustic spectroscopy for trace gas analysis. Appl. Sci. 2019, 9, 4021. [Google Scholar] [CrossRef] [Green Version]
  12. Lan, G.; Jin, Z.; Nong, J.; Luo, P.; Guo, C.; Sang, Z.; Dong, L.; Wei, W. Narrowband perfect absorber based on dielectric-metal meta-surface for surface-enhanced infrared sensing. Appl. Sci. 2020, 10, 2295. [Google Scholar] [CrossRef] [Green Version]
  13. Wieczorek, P.Z.; Starecki, T.; Tittel, F.K. Improving Signal to Noise Ratio of QTF Preamplifiers Dedicated for QEPAS Applications. Appl. Sci. 2020, 10, 4105. [Google Scholar] [CrossRef]
  14. Menduni, G.; Sampaolo, A.; Patimisco, P.; Giglio, M.; Russo, S.D.; Zifarelli, A.; Elefante, A.; Wieczorek, P.Z.; Starecki, T.; Passaro, V.M.N.; et al. Front-end amplifiers for Tuning Forks in Quartz Enhanced PhotoAcoustic Spectroscopy. Appl. Sci. 2020, 10, 2947. [Google Scholar] [CrossRef]
  15. Hayden, J.; Baumgartner, B.; Lendl, B. Anomalous Humidity Dependence in Photoacoustic Spectroscopy of CO Explained by Kinetic Cooling. Appl. Sci. 2020, 10, 843. [Google Scholar] [CrossRef] [Green Version]
  16. Mordmueller, M.; Edelmann, S.; Knestel, M.; Schade, W.; Willer, U. Phase Optimized Photoacoustic Sensing of Gas Mixtures. Appl. Sci. 2020, 10, 438. [Google Scholar] [CrossRef] [Green Version]
  17. Sgobba, F.; Menduni, G.; Russo1, S.D.; Sampaolo, A.; Patimisco, P.; Giglio, M.; Ranieri, E.; Passaro, V.M.N.; Tittel, F.K.; Spagnolo, V. Quartz-enhanced Photoacoustic Detection of Ethane in the Near-IR Exploiting a Highly Performant Spectrophone. Appl. Sci. 2020, 10, 2447. [Google Scholar] [CrossRef] [Green Version]
  18. Shang, Z.; Li, S.; Wu, H.; Dong, L. Quartz enhanced photoacoustic detection based on an elliptical laser beam. Appl. Sci. 2020, 10, 1197. [Google Scholar] [CrossRef] [Green Version]
  19. Zhao, F.; Gao, Y.; Yang, L.; Yan, Y.; Li, J.; Ren, J.; Russo, S.D.; Zifarelli, A.; Patimisco, P.; Wu, H.; et al. Near-infrared quartz-enhanced photoacoustic sensor for H2S detection in biogas. Appl. Sci. 2019, 9, 5347. [Google Scholar] [CrossRef] [Green Version]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Wu, H.; Sampaolo, A. Quartz-Enhanced Photoacoustic and Photothermal Spectroscopy. Appl. Sci. 2022, 12, 2613. https://doi.org/10.3390/app12052613

AMA Style

Wu H, Sampaolo A. Quartz-Enhanced Photoacoustic and Photothermal Spectroscopy. Applied Sciences. 2022; 12(5):2613. https://doi.org/10.3390/app12052613

Chicago/Turabian Style

Wu, Hongpeng, and Angelo Sampaolo. 2022. "Quartz-Enhanced Photoacoustic and Photothermal Spectroscopy" Applied Sciences 12, no. 5: 2613. https://doi.org/10.3390/app12052613

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop