Next Article in Journal
Garlic Extract: Inhibition of Biochemical and Biophysical Changes in Glycated HSA
Next Article in Special Issue
Cone-Beam Computed Tomography and the Related Scientific Evidence
Previous Article in Journal
Geopolymers Reinforced with Natural Fibers: A Comparison among Different Sources
Previous Article in Special Issue
Age Estimation Based on Pulp–Tooth Volume Ratio of Anterior Teeth in Cone-Beam Computed Tomographic Images in a Selected Population: A Cross-Sectional Study
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Effects of Incorporation of Marine Derived Hydroxyapatite on the Microhardness, Surface Roughness, and Fluoride Release of Two Glass-Ionomer Cements

1
School of Dental Medicine, University of Zagreb, Gundulićeva 5, 10000 Zagreb, Croatia
2
School of Dentistry, Hacettepe University, Ankara 06100, Turkey
*
Author to whom correspondence should be addressed.
Appl. Sci. 2021, 11(22), 11027; https://doi.org/10.3390/app112211027
Submission received: 9 November 2021 / Revised: 18 November 2021 / Accepted: 19 November 2021 / Published: 21 November 2021

Abstract

:
Background: The aim of this study was to evaluate the effects of incorporation of hydroxyapatite (HA) derived from cuttlefish bone on the microhardness, surface roughness (SR), and fluoride release (FR) of conventional cure, and resin-modified glass-ionomer cement. Methods: There were four groups for each tested material; experimental glass-ionomer were made by addition and of 2, 5, and 10 wt % HA respectively to conventional glass-ionomers Fuji II LC and Fuji IX GP Extra. One group was prepared without the addition of HA particles. For SR and microhardness measurements sectional Teflon molds (5 mm in diameter and 2 mm deep) were used to prepare 10 samples per group (n = 80). The samples were stored in distilled water at 37 °C for 7 days prior to testing. The SR was measured using a contact type profilometer and the microhardness was determined using a Vickers micro-hardness tester at a load of 980 g for 15 s. For FR measurements, there were six samples per group (n = 48), prepared in Teflon molds (8 mm in diameter and 2 mm deep). The FR was measured with an ionoselective electrode in triplicates after 24 h, 7 days, and 45 days. Statistical analysis was performed using one-way ANOVA with Tukey post-hoc test. Results and Conclusion: Microhardness values obtained for Fuji II modified with 10 wt % HA were significantly higher compared to the other two groups tested. Comparison of materials with respect to SR showed significant difference between them (p < 0.0001) with Fuji II and Fuji IX modified with HA having higher SR values. Regarding FR, Fuji IX showed statistically significant higher results than Fuji II, independently of HA modification, and groups modified with 2 and 5 wt % HA showed significantly increased fluoride release in all three time points.

1. Introduction

Since their introduction, glass-ionomer cements (GICs) have been a widely used material in restorative dentistry due to their ability to chemically bond to dental tissue, biocompatibility, easy handling, and fluoride release [1,2,3]. However, disadvantages of GICs—such as poor compressive strength (CS), hardness, elastic modulus, and wear resistance [4,5]—lead to proposing many modifications. One of the attempts is incorporation of different fillers into the matrix of the cement. Recently, the addition of specific percentages of micro- and nano-hydroxyapatite (nano-HA) particles to GICs has shown promising results, such as the increase in adhesive strength to dentin [6] and increased flexural strength, as shown in our previous study [7]. HA derived from fish bone was reported to be biocompatible if incorporated into material [8] and porous spherical HA particles have been shown to increase mechanical properties and the release of fluoride ions most effectively [7,9].
The hardness of restorative material is critical for the clinical longevity of restorations [10]. Previous research has shown that microhardness determined by the Vickers method is a valid measure of the surface properties of GICs [11,12]. An increased roughness can be a predisposing factor for bacterial colonization [13]; when exceeds 0.2 μm, the caries risk is increased because of bacterial accumulation, plaque maturation, and acidity [14]. Therefore, surface roughness (SR) of GIC materials is often defined as a measure of the wear of materials, which strongly influences the success of restoration [15].
The main effects of GIC’s anticariogenic and remineralization effects are largely due to fluoride release (FR), which is considered to be an important property of restorative dental materials and its release level has been shown to be influenced by material composition, storage conditions, and curing method [16,17,18]. Furthermore, it is suggested that addition of nano-sized particles enhances the release of fluoride from the GIC [19].
Having in mind the idea of developing the material with suitable biological and mechanical properties, the aim of this study was to evaluate the effect of incorporation of 2, 5, and 10 wt % HA, derived from the cuttle-fish bone by the hydrothermal method [20] in conventionally cured and light cured GIC, on microhardness and SR of GICs and to investigate its effects on chemical feature and fluoride release. The null hypothesis is that there will be no changes in microhardness, SR and FR properties of GIC after the addition of HA.

2. Materials and Methods

Highly porous HA was obtained from aragonitic cuttlefish (Sepia officinalis) bone from the Adriatic Sea by using the hydrothermal method. The HA powder in the form of hexagonal column crystal aggregates with a diameter of <180 µm was prepared by grounding and sifting bones through a 180 µm size sieve [20].
In the present study, two GICs were used: Fuji II LC and Fuji IX GP Extra (GC Corporation, Tokyo, Japan). The HA powder 2, 5, and 10 wt % (three experimental groups) and a glass powder were hand-mixed using a mortar and pestle for 20 min to obtain a homogenous powder. The prepared powder was then mixed with the polyacrylic acid by spatula. Four groups were prepared for each GIC material; the first group was without HA particles, while in the powder of three experimental groups 2, 5, and 10 wt % HA respectively was added.
For microhardness and SR testing sectional Teflon molds (5 mm diameter × 2 mm deep) were used to prepare 10 samples per group (n = 80). After mixing the GIC components by spatulation, the material was poured into a syringe (Centrix, Shelton, CT, USA) and immediately into Teflon molds. To avoid air trapping, polyester strips were placed and the material was gently compressed on both sides of the mold by glass. Fuji IX specimens were left to set for one hour. Both sides of each Fuji II sample were light-cured for 20 s to ensure a proper setting, using a LED lamp (Ivoclar Vivadent AG, Schaan, Lichtenstein, Germany), with intensity 600 mW/cm 2. The specimens were stored in distilled water at 37 °C for 7 days and than tested. SR and microhardness measurements were conducted on the same sample.
SR was measured using a contact type profilometer device (Perthometer M2, Mahr GmbH, Gottingen, Germany). Multidirectional readings were made for each specimen in five different areas. After five sequential measurements were performed at different locations for each specimen, the arithmetic mean of SR was calculated in μm. Specimens were fixed with a special jig to ensure that their position is the same for all measurements.
Microhardness measurements were performed using a digital microhardness tester (HMV-2, Shimadzu Corp., Kyoto, Japan). A 980 N force was applied to the specimens with a diamond indenter for 15 s. The testing machine was calibrated before each measurement. Indentations were made after the specimen surfaces were divided into four quadrants. Two measurements were taken in each quadrant, totaling eight measurements. The mean of the eight measurements represented specimen mean. These points were not at the margins or areas with visible irregularity. Microhardness was expressed as Vickers hardness number (VHN).
One specimen from each group was sputter-coated with gold and observed under SEM (JSM-6400 SEM, JEOL, Tokyo, Japan) at magnifications X15, X50, and X100.
Samples for the FR measurements were prepared as described for microhardness and SR. Six discs (8 mm diameter × 2 mm thick) for each GIC group were made using a Teflon mold (n = 48). After setting of material, samples were removed from the molds by applying pressure at one side and individually stored in polyethylene vials, in 5 mL deionized water and left at 37 °C for 24 h. The concentrations of fluoride released into the water were measured after 24 h, 7 days, and 45 days in triplicate for each sample and expressed in mg/L (ppm F). The deionized water was replaced after every testing procedure. For the measurements, each disk was removed from the water, dried on filter paper, weighed, and immediately immersed in 5 mL fresh deionized water for further measurements. The fluoride concentrations in the water samples were measured using an Ionoselective electrode (F800 DIN, Xylem Analytics Germany, Weilheim, Germany) connected to an ion analyzer (inoLab Multi 9630 DS; Xylem Analytics Germany, Weilheim, Germany). Buffer solution, 0.5 mL of TISAB III (Total Ionic Strength Adjustment Buffer; Merck KGaA, Darmstadt, Germany), was added to the water sample to achieve constant ionic strength and pH.
Regarding a statistical analysis of the data, a descriptive analysis was performed. Normality distribution was checked with the Shapiro–Wilk test while equality of variances was tested with Levene’s test. Due to heterogeneity of variances (Levene’s test; p = 0.0265 for surface roughness and p < 0.0001 for microhardness) Welch’s one-way ANOVA and a post-hoc Tukey’s test were performed. The analysis was conducted using a SPSS statistical package on a Windows platform. The level of significance was set at p = 0.05. For FR, obtained data were processed by the method of linear regression analysis, which was recommended by Can Karabulut et al. as the best method for investigation of fluoride releasing materials [21].

3. Results

Descriptive statistics for SR and microhardness properties in the eight groups are shown in Table 1.
The results of the material comparison are shown in Table 2.
Comparison of materials with respect to SR showed that there is a difference between them (p < 0.0001; ANOVA test). The results of the multiple comparison (Tukey test) with respect to SR showed that values for Fuji IX are higher on average in comparison to the values for Fuji II irrespective of HA concentration. For Fuji IX, SR also generally increases with the increase of HA concentration. Roughness of Fuji IX 10 wt % HA was statistically higher than the SR of Fuji IX without HA and Fuji IX 5 wt % HA.
There is difference in microhardness between the groups, too (p < 0.0001; ANOVA test). The addition of HA to Fuji II is not conclusive. Lowest microhardness is observed for 2 wt % HA, but Tukey test showed that microhardness of Fuji II with 10 wt % HA was significantly higher. In Fuji IX groups, it was observed that increase of HA concentration decreased microhardness. However, only the difference between 10 wt % HA concentration and 2 wt % HA concentration and the difference between 10 wt % HA concentration and group without HA particles added were significant. There was no evidence that microhardness for the group without HA particles and groups with 2 wt % HA and 5 wt % HA differ.
The observed SEM images of representative of one specimen surface from each group are shown in Figure 1.
The SEM images display small glass particles dispersed in the matrix. SEM images of Fuji II, either the group without HA added or experimental groups displayed predominantly smooth, and featureless surfaces (Figure 1, a–d) but cracks or voids were evident on the surfaces of HA added specimens (b–d) in contrast to the group without HA (a). The surfaces of Fuji IX (e–h) appeared relatively rough, demonstrating macro defects on the surfaces.
The results for fluoride ion release are shown in Figure 2.
The results for Fuji IX were significantly higher than the results for Fuji II (p < 0.001). In terms of time, it can be noticed that the concentration of the released fluoride ions rate significantly decreased with time (p < 0.001). This decrease was significantly different for the two materials (p < 0.001).
When observing the effects of adding HA to the materials, the fluoride release was different when compared to the group without HA added. This effect was, however, neither consistent nor clearly dependent on concentration. Adding HA in concentrations of 2 or 5 wt % HA resulted in significantly higher FR of Fuji IX in all three time points. The sample with 10 wt % HA showed significantly higher amounts of released fluorides than the group without HA, but lower than the samples with 2 and 5 wt % HA. The results are shown in Table 3.
With Fuji II, the results were similar in the sense that the 2 wt % HA samples showed significantly higher FR rates than the other samples after 7 days and 45 days, while the 5 wt % HA samples had lower results than either 2 wt % HA, 10 wt % HA or samples without HA in all three time points.

4. Discussion

Our results showed that the addition of marine derived HA particles to commercially available GIC materials influenced SR, microhardness and FR, leading to rejection of the null hypothesis. HA particles used for experimental part were micro-sized because it was found that nano-HA-filled materials were rougher [22]. Additionally, micro-particles of HA are easily mixed with resin and nano-HA considerably prolongs the setting time of GICs [23].
SR values for Fuji II were significantly lower in comparison to the values for Fuji IX with no dependence on HA concentration. This is in agreement with the findings of Ismail et al. [24] who showed that resin modified glass ionomer cement (RMGIC) exhibited lower surface roughness than did chemically cured, possibly due to its smaller filler size (0.02–0.04 μm). SR values increased with the rise of HA concentration in both materials tested as a consequence of HA particles formed by hydrothermal conversion having a cauliflower-like morphology, thus increasing the surface roughness and specific surface energy [20]. Additional SEM analysis confirmed predominantly smooth, and featureless surfaces in Fuji II specimens probably due to incorporation of the resin, while the surfaces of Fuji IX appeared relatively rough demonstrating macro defects on the surfaces faster.
Our results demonstrate a trend of higher microhardness values for Fuji II than for Fuji IX. The exception is value for 2 wt % HA, where mean for Fuji IX sample is higher than mean for Fuji II sample. Yli Up et al. examined the microhardness of the GIC and RMGIC with 10% or 30% HA [25]. They reported that the microhardness of GICs decreased as the amount of HA increased, which is in accordance with results of the present study. The explanation for difference in results could be the fact that the microhardness of HA-added Fuji II increased during water storage [12]. In addition, larger particle size and fewer voids and cracks of RMGIC resulted in higher microhardness values. Among all the eight groups, RMGIC (Fuji II) with 10 wt % HA had the highest microhardness value. When compared to an earlier study where the group with 10 wt % HA had the highest flexural strength value [26], it is possible that this exact concentration of HA particles could improve two important physical properties of Fuji II, microhardness, and SR. This result is in agreement with Lee’s survey, which was shown that the physical properties of RMGI improved with the incorporation of 10% nano- and micro-HA [27]. Some studies have shown that incorporation of 5 wt % HA in GICs resulted in improved mechanical properties, including compressive strength and microhardness [28,29]. This difference could be explained with possible non-uniformed glass—HA powder (manual mixing) or inadequate liquid amount, as the volume of HA can change the reaction. It was indeed shown that resin modified GICs are more stable in water than are conventional GICs [28], but resin from RMGICs have been shown to have negative effects on dental pulp, it also exhibits cytotoxicity [30]. It would therefore be ideal in a clinical context to obtain better chemo-mechanical properties of chemically set GICs.
Addition of HA in concentrations of 2 or 5 wt % HA resulted in significantly higher FR of Fuji IX in all three time points
It was previously shown that the light or chemical curing influences fluoride release from resin modified GICs and dual-cured resin cements. Furthermore, photoinitiated polymerization enhances cross-linking density, resulting in the reduced resin matrix permeability for fluoride ions [31], what is in accordance with our results, generally higher FR results in Fuji IX GP Extra than in Fuji II. On the other hand, modification of Fuji II powder with 2 wt % HA positively influenced the fluoride release rates compared to other samples measured after 7 days and 45 days. The modification of Fuji IX GP Extra in all concentrations of HA showed improved FR in all three time points. In our study the highest values of FR were in the first 24 h ranged from 15–138 mg/L for different GICs, what agrees with previous investigations [32,33]. The fluoride ions in the GICs structure do not take part in the setting reaction and after the initial burst effect [34], they are released into the surrounding environment via an ion exchange process. Furthermore, the glass ionomers can also absorb salivary fluoride and act as fluoride reservoirs capable of releasing the ions, which may inhibit caries formation [35].
As HA derived from cuttlefish bone was reported to be biocompatible [16] and a biomaterial without any cytotoxic effect on dental pulp cells if incorporated into restorative material, it could be interesting to perform further investigations about its impact on GICs. The limitations of the study are that it does not implement all the factors that could affect the material itself, such as mastication forces, heat change, exposure to saliva. However, all the samples were exposed to the same experimental conditions. In addition, only representative commercial materials have been used; a wide range of GICs is available and could be tested. Finally, the clinical relevance of our findings remains unclear; these types of in vitro studies provide insight into the possible effects of HA incorporation, but the results should be observed considering the conditions of the study.

5. Conclusions

The present study showed that the addition of micro-HA derived from cuttlefish bone to the powders of Fuji IX and Fuji II does not improve the SR. As far as microhardness is concerned, the addition of HA decreased microhardness values in all groups except the Fuji II 10 wt % HA group. In terms of FR, samples of Fuji IX modified with 10 wt % HA, after 24 h showed most favorable results, and 2 and 5 wt % HA improved FR in all three time points, what can lead to conclusion that the exact concentration of HA incorporated in GIC improving chemo-mechanical properties should be further investigated.

Author Contributions

Conceptualization, I.M.; Methodology, M.B.-P.; Validation, M.B.-P. and S.J.K.; Formal analysis, S.G. and U.K.V.; Investigation, M.B.-P. and I.Š.; Resources, I.M.; Writing—original draft preparation, M.B.-P. and I.Š.; Writing—review and editing S.G., I.Š. and U.K.V.; Visualization, S.J.K.; Supervision, I.M.; Funding acquisition, I.M. All authors have read and agreed to the published version of the manuscript.

Funding

The research was conducted within the Croatian Science Foundation project ‘Research and Development of New Micro and Nanostructural Bioactive Materials in Dental Medicine’, BIODENTMED no. IP-2018-01-1719.

Institutional Review Board Statement

The study was conducted according to the guidelines of the Declaration of Helsinki and approved by the Institutional Ethics Committee of University of Zagreb, School of Dental Medicine (No. 05-PA-30-XIII-1/2020).

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Acknowledgments

A portion of this research has been presented at 1st International Conference on Applied Sciences, Section: Applied Dentistry. In addition, the authors would like to thank Hrvoje Ivanković and Ana Marija Rogina from the Faculty of Chemical Engineering and Technology, University of Zagreb, for providing hydroxyapatite derived from cuttlefish bone.

Conflicts of Interest

The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.

References

  1. Da Silva, R.C.; Zuanon, A.C.C. Surface of Glass Ionomer Cements Indicated for Atraumatic Restorative Treatment (ART). Braz Dent J. 2006, 17, 106–109. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  2. Sidhu, S.K.; Nicholson, J.W. A Review of Glass-Ionomer Cements for Clinical Dentistry. J. Funct. Biomater. 2016, 7, 16. [Google Scholar] [CrossRef]
  3. Hotz, P.; McLean, J.W.; Sced, I.; Wilson, A.D. The bonding of glass ionomer cements to metal and tooth substrates. Br. Dent. J. 1977, 142, 41–47. [Google Scholar] [CrossRef] [PubMed]
  4. Peutzfeldt, A.; García-Godoy, F.; Asmussen, E. Surface hardness and wear of glass ionomers and compomers. Am. J. Dent. 1997, 10, 15–17. [Google Scholar]
  5. Šalinović, I.; Stunja, M.; Schauperl, Z.; Verzak, Ž.; Ivanišević Malčić, A.; Brzović Rajić, V. Mechanical Properties of High Vis-cosity Glass Ionomer and Glass Hybrid Restorative Materials. Acta Stomatol. Croat. 2019, 53, 125–131. [Google Scholar] [CrossRef] [PubMed]
  6. Moshaverinia, A.; Ansari, S.; Movasaghi, Z.; Billington, R.W.; Darr, J.A.; Rehman, I.U. Modification of conventional glass-ionomer cements with N-vinylpyrrolidone containing polyacids, nano-hydroxy and fluoroapatite to improve mechanical properties. Dent. Mater. 2008, 24, 1381–1390. [Google Scholar] [CrossRef]
  7. Bilić-Prcić, M.; Brzović Rajić, V.; Ivanišević, A.; Pilipović, A.; Gurgan, S.; Miletić, I. Mechanical Properties of Glass Ionomer Cements after Incorporation of Marine Derived Hydroxyapatite. Materials (Basel) 2020, 13, 3542. [Google Scholar] [CrossRef]
  8. Yamamura, H.; da Silva, V.H.P.; Ruiz, P.; Ussui, V.; Lazar, D.R.R.; Renno, A.C.M.; Ribeiro, D. Physico-chemical characterization and biocompatibility of hydroxyapatite derived from fish waste. J. Mech. Behav. Biomed. Mater. 2018, 80, 137–142. [Google Scholar] [CrossRef]
  9. Arita, K.; Yamamoto, A.; Shinonaga, Y.; Harada, K.; Abe, Y.; Nakagawa, K.; Sugiyama, S. Hydroxyapatite particle characteristics influence the enhancement of the mechanical and chemical properties of conventional restorative glass ionomer cement. Dent. Mater. J. 2011, 30, 672–683. [Google Scholar] [CrossRef] [Green Version]
  10. Nicholson, J.W. Chemistry of glass-ionomer cements: A review. Biomaterials 1998, 19, 485–494. [Google Scholar] [CrossRef]
  11. Shintome, L.K.; Nagayassu, M.P.; Di Nicoló, R.; Myaki, S.I. Microhardness of glass ionomer cements indicated for the ART technique according to surface protection treatment and storage time. Braz. Oral Res. 2009, 23, 439–445. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  12. Ellakuria, J.; Triana, R.; Mínguez, N.; Soler, I.; Ibaseta, G.; Maza, J.; García-Godoy, F. Effect of one-year water storage on the surface microhardness of resin-modified versus conventional glass-ionomer cements. Dent. Mater. 2003, 19, 286–290. [Google Scholar] [CrossRef]
  13. Bollenl, C.M.; Lambrechts, P.; Quirynen, M. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: A review of the literature. Dent. Mater. 1997, 13, 258–269. [Google Scholar] [CrossRef]
  14. Yap, A.U.; Lye, K.W.; Sau, C.W. Surface characteristic of tooth coloured restoration polished utilizing different polishing systems. Oper Dent. 1997, 22, 260–265. [Google Scholar] [PubMed]
  15. Miličević, A.; Goršeta, K.; Van Duinen, R.N.; Glavina, D. Surface Roughness of Glass Ionomer Cements after Application of Different Polishing Techniques. Acta Stomatol. Croat. 2018, 52, 314–321. [Google Scholar] [CrossRef]
  16. Goenka, S.; Balu, R.; Kumar, T.S. Effects of nanocrystalline calcium deficient hydroxyapatite incorporation in glass ionomer cements. J. Mech. Behav. Biomed. Mater. 2012, 7, 69–76. [Google Scholar] [CrossRef] [PubMed]
  17. Bresciani, E.; Barata, T.D.J.E.; Fagundes, T.C.; Adachi, A.; Terrin, M.M.; Navarro, M.F.L. Compressive and diametral tensile strength of glass ionomer cements. J. Appl. Oral Sci. 2004, 12, 344–348. [Google Scholar] [CrossRef] [PubMed]
  18. Yoshida, Y.; Van Meerbeek, B.; Nakayama, Y.; Snauwaert, J.; Hellemans, L.; Lambrechts, P.; Vanherle, G.; Wakasa, K. Evidence of Chemical Bonding at Biomaterial-Hard Tissue Interfaces. J. Dent. Res. 2000, 79, 709–714. [Google Scholar] [CrossRef] [PubMed]
  19. Moshaverinia, A.; Ansari, S.; Moshaverinia, M.; Roohpour, N.; Darr, J.A.; Rehman, I. Effects of incorporation of hydroxyapatite andfluorapatite nanobioceramics into conventional glass ionomer cements (GIC). Acta Biomater. 2008, 4, 432–440. [Google Scholar] [CrossRef]
  20. Rogina, A.; Antunović, M.; Milovac, D. Biomimetic design of bone substitutes based on cuttlefish bone-derived hydroxyapatite and biodegradable polymers. J. Biomed. Mater. Res. Part B Appl. Biomater. 2018, 107, 197–204. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  21. Can-Karabulut, D.C.; Batmaz, I.; Solak, H.; Taştekin, M. Linear regression modeling to compare fluoride release profiles of various restorative materials. Dent. Mater. 2007, 23, 1057–1065. [Google Scholar] [CrossRef]
  22. Domingo, C.; Arcis, R.W.; Lopez-Macipe, A.; Osorio, R.; Rodriguez-Clemente, R.; Murtra, J.; Toledano, M. Dental composites reinforced with hydroxyapatite: Mechanical behavior and absorption/elution characteristics. J. Biomed. Mater. Res. 2001, 56, 297–305. [Google Scholar] [CrossRef]
  23. Venhoven, B.A.M.; de Gee, A.J.; Werner, A.; Davidson, C.L. Influence of filler parameters on the mechanical coherence of dental restorative composites. Biomaterials 1996, 17, 735–740. [Google Scholar] [CrossRef]
  24. Hoda, S.I.; Ashraf, I.A.; Mohammed, A.A.E.-E.; Salah, H. Effect of different polishing techniques on surface roughness and bacterial adhesion of three glass ionomer-based restorative materials: In vitro study. J. Clin. Exp. Dent. 2020, 12, e620–e625. [Google Scholar]
  25. Yli-Urpo, H.; Lassila, L.V.; Närhi, T.; Vallittu, P.K. Compressive strength and surface characterization of glass ionomer cements modified by particles of bioactive glass. Dent. Mater. 2005, 21, 201–209. [Google Scholar] [CrossRef]
  26. Gjorgievska, E.; Nicholson, J.W.; Gabrić, D.; Guclu, Z.A.; Miletić, I.; Coleman, N.J. Assessment of the Impact of the Addition of Nanoparticles on the Properties of Glass–Ionomer Cements. Materials 2020, 13, 276. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  27. Lee, J.-J.; Lee, Y.-K.; Choi, B.-J.; Lee, J.-H.; Choi, H.-J.; Son, H.-K.; Hwang, J.-W.; Kim, S.-O. Physical properties of resin-reinforced glass ionomer cement modified with micro and nano-hydroxyapatite. J. Nanosci. Nanotechnol. 2010, 10, 5270–5276. [Google Scholar] [CrossRef] [PubMed]
  28. Sharafeddin, F.; Shoale, S.; Kowkabi, M. Effects of Different Percentages of Microhydroxyapatite on Microhardness of Resin-modified Glass-ionomer and Zirconomer. J. Clin. Exp. Dent. 2017, 9, e805–e811. [Google Scholar] [CrossRef] [Green Version]
  29. Khaghani, M.; Doostmohammadi, A.; Monshi, A.; Golnia, Z. Effect of incorporating nano-particles of hydroxyapatite on bioactivity and compressive strength of dental glass-ionomer cements. J. Isfahan Dent. Sch. 2013, 8, 593–605. [Google Scholar]
  30. Souza, P.; Aranha, A.; Hebling, J.; Giro, E.; Costa, C.A.D.S. In vitro cytotoxicity and in vivo biocompatibility of contemporary resin-modified glass-ionomer cements. Dent. Mater. 2006, 22, 838–844. [Google Scholar] [CrossRef]
  31. Yoda, A.; Nikaido, T.; Ikeda, M.; Sonoda, H.; Foxton, R.M.; Tagami, J. Effect of curing method and storage condition on fluoride ion release from a fluoride-releasing resin cement. Dent. Mater. J. 2006, 25, 261–266. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  32. Attar, N.; Turgut, M.D. Fluoride release and uptake capacities of fluoride-releasing restorative materials. Oper. Dent. 2003, 28, 395–402. [Google Scholar] [PubMed]
  33. Yap, A.U.J.; Tham, S.Y.; Zhu, L.Y.; Lee, H.K. Short-term fluoride release from various aesthetic restorative materials. Oper. Dent. 2002, 27, 259–265. [Google Scholar] [PubMed]
  34. Mousavinasab, S.M.; Meyers, I. Fluoride release and uptake by glass ionomer cements, compomer and giomer. Dent. Res. J. (Isfahan) 2009, 6, 75–81. [Google Scholar]
  35. Vrček, D.; Prpić-Mehičić, G.; Verzak, J.; Vrček, J.; Matijevic, J.; Grget, K.R. Fluoride Release from Hard Dental Tissue Restorative Materials. Acta Stomatol. Croat. 2013, 47, 111–119. [Google Scholar] [CrossRef]
Figure 1. Representative SEM photomicrographs (×100 magnification) of a Fuji II (first row): Fuji II (without HA particles), Fuji II 2 wt % HA, Fuji II 5 wt % HA, Fuji II 10 wt % HA respectively; and Fuji IX (2nd row): Fuji IX (without HA particles), Fuji IX 2 wt % HA, Fuji IX 5 wt % HA, Fuji IX 10 wt % HA respectively.
Figure 1. Representative SEM photomicrographs (×100 magnification) of a Fuji II (first row): Fuji II (without HA particles), Fuji II 2 wt % HA, Fuji II 5 wt % HA, Fuji II 10 wt % HA respectively; and Fuji IX (2nd row): Fuji IX (without HA particles), Fuji IX 2 wt % HA, Fuji IX 5 wt % HA, Fuji IX 10 wt % HA respectively.
Applsci 11 11027 g001
Figure 2. Fluoride release after 24 h, 7 days, and 45 days.
Figure 2. Fluoride release after 24 h, 7 days, and 45 days.
Applsci 11 11027 g002
Table 1. Descriptive statistics for surface roughness (SR) and microhardness.
Table 1. Descriptive statistics for surface roughness (SR) and microhardness.
MaterialNSR
Mean
Microhardness
Mean
Fuji II0100.0620.070
Fuji II2100.0690.078
Fuji II5100.0800.087
Fuji II10100.0890.097
Fuji IX0100.1760.199
Fuji IX2100.2210.269
Fuji IX5100.1920.212
Fuji IX10100.2540.282
Table 2. Results of the ANOVA test for Fuji II and Fuji IX.
Table 2. Results of the ANOVA test for Fuji II and Fuji IX.
MaterialSurface Roughness
(Ra)
Microhardness (VHN)
Fuji II00.062a55.2ab
Fuji II20.069a47.5bc
Fuji II50.080a53.0b
Fuji II100.089a61.5a
Fuji IX00.176b50.6b
Fuji IX20.221bc48.9b
Fuji IX50.192b47.2bc
Fuji IX100.254c40.7c
p *<0.0001 <0.0001
* p-value for ANOVA test; a, b, c—materials with the same letter are not significantly different (Tukey test).
Table 3. The release rate of flouride after 24 h, 7 days, and 45 days.
Table 3. The release rate of flouride after 24 h, 7 days, and 45 days.
Mean ± Standard Error24 h (mg/L)7 Days (mg/L)45 Days (mg/L)p
Fuji IX0
Fuji IX2
Fuji IX5
Fuji IX10
77.7 ± 1.7 c17.1 ± 0.8 d2.7 ± 0.1 d<0.001
138.1 ± 1.3 a24.5 ± 0.5 b3.9 ± 0.1 b<0.001
138.6 ± 2.3 a30.4 ± 0.2 a4.8 ± 0.0 a<0.001
83.3 ± 2.3 b20.8 ± 0.4 c3.3 ± 0.1 c<0.001
Fuji II0
Fuji II2
Fuji II5
Fuji II10
19.6 ± 0.9 e8.9 ± 0.1 f1.4 ± 0.0 f<0.001
21.1 ± 0.5 e10.4 ± 0.1 e1.6 ± 0.0 e<0.001
15.8 ± 1.3 f8.1 ± 0.1 g1.3 ± 0.0 g<0.001
22.1 ± 0.4 e8.8 ± 0.0 f1.4 ± 0.0 f<0.001
a–g the differences between the groups within a specific column/time point are statistically significant with p < 0.05.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Bilić-Prcić, M.; Šalinović, I.; Gurgan, S.; Koc Vural, U.; Krmek, S.J.; Miletić, I. Effects of Incorporation of Marine Derived Hydroxyapatite on the Microhardness, Surface Roughness, and Fluoride Release of Two Glass-Ionomer Cements. Appl. Sci. 2021, 11, 11027. https://doi.org/10.3390/app112211027

AMA Style

Bilić-Prcić M, Šalinović I, Gurgan S, Koc Vural U, Krmek SJ, Miletić I. Effects of Incorporation of Marine Derived Hydroxyapatite on the Microhardness, Surface Roughness, and Fluoride Release of Two Glass-Ionomer Cements. Applied Sciences. 2021; 11(22):11027. https://doi.org/10.3390/app112211027

Chicago/Turabian Style

Bilić-Prcić, Maja, Ivan Šalinović, Sevil Gurgan, Uzay Koc Vural, Silvana Jukić Krmek, and Ivana Miletić. 2021. "Effects of Incorporation of Marine Derived Hydroxyapatite on the Microhardness, Surface Roughness, and Fluoride Release of Two Glass-Ionomer Cements" Applied Sciences 11, no. 22: 11027. https://doi.org/10.3390/app112211027

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop