Next Article in Journal
A Review of the Assessment Tools for the Efficiency of Nanolime Calcareous Stone Consolidant Products for Historic Structures
Next Article in Special Issue
Seismic Response of a Structure Equipped with an External Viscous Damping System
Previous Article in Journal
Representing Small Commercial Building Faults in EnergyPlus, Part I: Model Development
Previous Article in Special Issue
An Optimal Seismic Force Pattern for Uniform Drift Distribution
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Correction

Correction: Fujii, K. Pushover-Based Seismic Capacity Evaluation of Uto City Hall Damaged by the 2016 Kumamoto Earthquake. Buildings 2019, 9, 140

Department of Architecture, Faculty of Creative Engineering, Chiba Institute of Technology, Chiba 275-0016, Japan
Buildings 2019, 9(11), 234; https://doi.org/10.3390/buildings9110234
Submission received: 5 November 2019 / Accepted: 11 November 2019 / Published: 15 November 2019
It is very unfortunate that there are some errors in the nonlinear analysis program used for this published article [1]: The subroutine of calculating the damping matrix for nonlinear time-history analyses is incorrect. Therefore, the author wishes to make the following corrections.
1.
Corrections 1: Section 3.2.
The author would like to correct the following lines:
“The damping matrix is assumed to be proportional to the initial stiffness matrix, with 5% of the first mode’s critical damping.”
To describe the damping matrix assumed in the nonlinear time-history analysis correctly, the author would like to make the following corrections.
“The damping matrix is assumed to be proportional to the tangent stiffness matrix, with 5% of the first mode’s critical damping. Note that, when its tangent stiffness is negative, non-zero dummy positive value (10−9 times smaller than the initial stiffness) is used for the calculation of the damping matrix to avoid the negative damping.”
2.
Corrections 2: Section 4.3.2. (Figures 22 and 23)
Due to the corrections of the nonlinear analysis program, the author wishes to replace these figures as follows.
Original image of Figure 22:
Buildings 09 00234 i001
Revised image of Figure 22:
Buildings 09 00234 i002
Original image of Figure 23:
Buildings 09 00234 i003
Revised image of Figure 23:
Buildings 09 00234 i004
3
Corrections 3: Section 4.3.2.
The author would like to correct the following lines:
“When λ = CI,uni = 0.361, the median value of the peak drift at column A1B1, where the largest drift occurred, slightly exceeded its drift limit (R = 1/75), as shown in Figure 22. In addition, the predicted peak drift by MABPA exceeds its drift limit (R = 1/75) at column A1B1 and A3B1. While in the case of λ = CI,bi = 0.330, the median peak drift values for all three columns were within the drift limit, as shown in Figure 23. In addition, the predicted peak drift by MABPA is very close to R = 1/75 at column A1B1.
Therefore, the accuracy of the evaluated seismic capacity index for this building was satisfactory. Moreover, index CI,bi had a slightly conservative value, while the value of index CI,uni was not conservative. Also note that the accuracy of the predicted peak drift by MABPA for this building was satisfactory.”
Due to the replacement of Figures 22 and 23, the author would like to make the following corrections.
“When λ = CI,uni = 0.361, the mean value of the peak drift at all three columns notably exceeded its drift limit (R = 1/75), as shown in Figure 22. In addition, the predicted peak drift by MABPA exceeds its drift limit (R = 1/75) at column A1B1 and A3B1. While in the case of λ = CI,bi = 0.330, the mean peak drift at column A1B1 and A3B1 was closer to the drift limit than the case of λ = CI,uni = 0.361, as shown in Figure 23. In addition, the predicted peak drift by MABPA is very close to R = 1/75 at column A1B1.
Therefore, the accuracy of the evaluated seismic capacity index for this building was satisfactory. Moreover, index CI,bi was better than index CI,uni because in this building, the effect of bidirectional excitation was significant. In addition, note that the accuracy of the predicted peak drift by MABPA for this building was satisfactory.”
4
Corrections 4: Section 6.
The author would like to correct the following lines in the first conclusion:
“The results show that the accuracy of the evaluated seismic capacity index for this building was satisfactory. Moreover, index CI,bi had a slightly conservative value, while whereas index CI,uni did not have a conservative value.”
Due to the replacement of Figures 22 and 23 in Section 4.3.2, the author would like to make the following corrections.
“The results show that the accuracy of the evaluated seismic capacity index for this building was satisfactory. Moreover, index CI,bi was better than index CI,uni because in this building, the effect of bidirectional excitation was significant.”
The corresponding author apologizes for any inconvenience caused to the readers. The changes do not affect other scientific results and conclusions. The manuscript will be updated, and the original will remain available. A link to this Correction will be added.

References

  1. Fujii, K. Pushover-Based Seismic Capacity Evaluation of Uto City Hall Damaged by the 2016 Kumamoto Earthquake. Buildings 2019, 9, 140. [Google Scholar] [CrossRef] [Green Version]

Share and Cite

MDPI and ACS Style

Fujii, K. Correction: Fujii, K. Pushover-Based Seismic Capacity Evaluation of Uto City Hall Damaged by the 2016 Kumamoto Earthquake. Buildings 2019, 9, 140. Buildings 2019, 9, 234. https://doi.org/10.3390/buildings9110234

AMA Style

Fujii K. Correction: Fujii, K. Pushover-Based Seismic Capacity Evaluation of Uto City Hall Damaged by the 2016 Kumamoto Earthquake. Buildings 2019, 9, 140. Buildings. 2019; 9(11):234. https://doi.org/10.3390/buildings9110234

Chicago/Turabian Style

Fujii, Kenji. 2019. "Correction: Fujii, K. Pushover-Based Seismic Capacity Evaluation of Uto City Hall Damaged by the 2016 Kumamoto Earthquake. Buildings 2019, 9, 140" Buildings 9, no. 11: 234. https://doi.org/10.3390/buildings9110234

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop