Article

Drain-Source Voltage-Controllable Three-Switch Active-Clamp Forward Converter for Wide Input/Output Voltage Applications

Department of Control and Instrumentation Engineering, Gyeongsang National University, Jinju 52828, Republic of Korea
*
Author to whom correspondence should be addressed.
Micromachines 2023, 14(1), 35; https://doi.org/10.3390/mi14010035
Submission received: 17 November 2022 / Revised: 7 December 2022 / Accepted: 21 December 2022 / Published: 23 December 2022
(This article belongs to the Special Issue Advances in Power Electronics Converters and Control)

Abstract

:
Active-clamp forward converters are applied to various medium-capacity power systems because they have a relatively simple structure and are capable of zero-voltage switching. In particular, there is the advantage that a stable output voltage can be obtained by controlling the duty ratio of the power semiconductor switch even in applications with wide input and output voltage ranges. However, the voltage stress on the power semiconductor switches due to the application of active clamp is higher than the input voltage, especially as the duty ratio increases. A three-switch active-clamp forward converter is proposed, which can overcome such shortcomings and can reduce the voltage stress of the power semiconductor switches, but it causes an increase in the DC bias of the magnetizing current and the additional conduction and switching losses. Therefore, in this paper, a voltage-stress-controllable three-switch active-clamp forward converter that can utilize both advantages of the conventional active-clamp forward converter and three-switch active clamp forward converter is proposed and verified through a prototype for 800 W battery charger.

1. Introduction

In recent years, with the development of various mobile devices, QC (Quick Charge) and PD (Power Delivery) chargers that can rapidly charge various types of batteries have been released, and the maximum output voltage and power capacity are increasing [1,2]. In addition, as smart mobility services expand, demand of battery charging systems for electric scooters is increasing, and battery sharing services for electric motorcycles are also expanding from Southeast Asia [3,4,5]. Furthermore, the spread of electric vehicles is expanding due to the de-petroleum and carbon-neutral policies that are being implemented all around the world. Accordingly, the demands for driving distance and large-capacity batteries are increasing. That is, active research and development of power converters for battery-powered systems is required [6,7,8].
Since the battery has a wide voltage range, the power system for the battery has a wide input voltage range, and the battery charging system must cover the wide output voltage range [9,10]. Therefore, a power conversion topology with a wide input/output voltage gain is needed. For a low power rating of less than 100 W, the active-clamp flyback converter is mainly used, and the LLC resonant converter and phase-shift full-bridge converter are applied as a high-power topology of 1 kW or above. However, the LLC resonant converter is difficult to use as a battery charger due to disadvantages such as reduced efficiency and increased price as it is applied in combination with a pre-regulator or post-regulator depending on the narrow input/output voltage gain [11,12,13,14,15]. Moreover, a highly reliable and robust control method may be required to commercialize these topologies. However, in the case of a powerful control method, implementation is very complicated, and it is difficult to apply such a complex control method to actual products [16,17].
On the other hand, the active-clamp forward converter in Figure 1a with a wide input/output voltage gain according to the change of the duty ratio can be applied [18,19,20,21,22]. Continuous current is supplied thanks to the output inductor, and power efficiency can be improved through zero-voltage switching. However, the voltage stress of the power semiconductor switch is higher than the input voltage and, in particular, increasing voltage stress due to increased duty ratio is a drawback. As shown in Figure 1b, a three-switch active-clamp forward converter with additional one switch and one diode has been proposed to reduce the voltage stress of the power semiconductor switch [23,24].
Nevertheless, the voltage applied to the transformer increases due to the added switch, and as the magnetizing current is biased to the positive direction, the peak current increases and the zero-voltage switching performance is deteriorated. Therefore, in this paper, by varying the duty of the additional switch QT, according to the load conditions. The voltage-stress-controllable three-switch active-clamp forward converter, which can take all the advantages by properly switching between the operation of the conventional active clamp forward converter and three-switch active clamp forward converter, is proposed and verified through a prototype circuit for the 800 W battery charger.

2. Analysis of Voltage Stress

The voltage stress of the main switch in the forward converter topology with the active clamp circuit can be expressed as the sum of the input voltage and the clamp capacitor voltage. In this case, it shows that the voltage of the clamp capacitor increases when the duty ratio increases as shown in Figure 2a. Additionally, in the case of a three-switch active clamp-forward converter, the voltage stresses of the main switch, QM and clamp switch, QC can be obtained by the sum of the input voltage and the voltage of the clamp capacitor.
However, with the additional switch QT, as shown in Figure 3, both the input voltage and the clamp capacitor voltage contribute to the transformer reset operation, which indicates that the voltage of the clamp capacitor is lower than that of the conventional active clamp-forward converter. Therefore, it can be confirmed that the voltage stress of the three-switch active clamp-forward converter is relatively lower than that of the conventional active clamp-forward converter as shown in Figure 2b. In addition, conventional active clamp forward converters achieve zero-voltage switching from the application of active clamp circuits, and the voltage charged to clamp capacitor CC is added to the input voltage to determine the voltage stress of primary main switch QM and clamp switch QC. From the voltage second balance equation for transformer TF, voltage stress of clamp capacitor VCc and voltage stress of main switch QM and clamp switch QC as a function of D are induced as shown in Equations (1)–(3).
D V i n ( 1 D ) V C c = 0
V C c = D 1 D V i n
V D S . m a x ( Q M   a n d   Q C ) = V i n 1 D
On the other hand, in the case of a three-switch active-clamp forward converter, the additional switch QT turns on and off at the same time as the main switch QM, so the voltage charged in the clamp capacitor CC is relatively reduced. The voltage stresses of QM and QC are formed by the voltage second balance equation for transformer TF, and it can be derived as the following Equations (4)–(8).
D V i n D 1 ( V i n + V C c ) D 2 ( V C c ) = 0
D 1 2 ( 1 D 1 ) = ( 1 D D 1 ) 2 ( D D 1 )
V C c = D D 1 1 D V i n
V D S ( Q M   a n d   Q C ) = 1 D 1 1 D V i n
D 1 = ( 1 + D ) 1 2 D + 5 D 2 2
In other words, it is possible to reduce the voltage stress of main switch QM and clamp switch QC through the addition of the additional switch QT and simultaneous switching with the main switch QM.

3. Characteristics and Voltage Stress Control Circuits of the Proposed Converter

The three-switch active-clamp forward converter has a possibility of reduced efficiency due to switching loss and conduction loss occurring in the additional switch with high current stress of the additional diode. In order to minimize this disadvantage, by delaying the turn-off time of QT compared to the turn-off time of QM, the voltage stress of QM and QC is slightly increased, but current stress of additional diodes and the turn-off switching loss of additional switch can be reduced as shown in Figure 4. Additionally, it is possible to reduce the peak current and to improve the zero-voltage switching performance by lowering the DC bias of the transformer magnetizing current. That is, as the duty ratio DT of the additional switch QT is increased, it becomes closer to the conventional active-clamp forward converter, and if the QT is continuously maintained in the turn-on state, it eventually operates the same as the conventional active-clamp forward converter.
By varying duty ratio DT of QT flexibly according to input/output voltages and output load conditions, its operation can maximize the advantages of the conventional active-clamp forward converter and three-switch active-clamp forward converter. In the case of the conventional active-clamp forward converter, the voltage stress of QM and QC can be expressed by Equation (3), but in the case of the proposed converter, by reflecting the case when duty of the additional switch QT can be increased compared to the conventional, D1 is changed as Equation (9).
D 1 = ( 1 D 2 ) ( 1 D 2 ) 2 4 D ( 1 D ) ( 1 2 D T + 2 D D T D 2 ) 2 ( 1 D )
Eventually, according to the purpose of the three-switch active-clamp forward converter to reduce voltage stress, a control circuit that can vary DT within the range that limits the maximum allowable voltage stress is configured as shown in Figure 5. In the case of a control circuit, the maximum voltage can be set by considering the voltage rating of QM and QC. As the duty ratio DT are increased, the voltage stress of the main switch QM and the clamp switch QC increases. By taking advantage of this, it is a method that allows the circuit to operate while maintaining the desired voltage stress by increasing the duty ratio DT, as much as there is voltage margin.

4. Operation Principles

4.1. Mode Analysis

The proposed converter operates either as an active-clamp forward converter or as a three-switch active-clamp forward converter, depending on the duty ratio of the additional switch QT. That is, in a load requiring a small duty ratio of the main switch, it will operate close to an active-clamp forward converter, and in a load requiring a large duty ratio of the main switch, it will operate close to a three-switch active-clamp forward converter. Therefore, the mode analysis of the proposed converter focuses on the middle operation area between the above two topologies, and describes by dividing into four operation modes, as shown in Figure 6. In addition, the key waveforms of the proposed converter are as shown in Figure 7.
Mode 1 (t1~t2): The main switch QM, and additional switch QT are turned on at the same time. Therefore, an input voltage is applied to the transformer, iLK rises in a positive direction, energy is transferred to the secondary side, DS1 is conducted, and an output is transferred to the load.
Mode 2 (t2~t3): The main switch QM turns off, and the additional switch QT maintains turn-on state. Thus, the output capacitance of main switch QM is charged and the output capacitance of clamp switch QC is discharged. At this time, the transformer current iLK flows through the additional switch QT and body-diode of clamp switch QC, so iLK decreases slowly. As the clamp switch QC, which reached the zero voltage, turns on, iLK conducts through the channel of the clamp switch QC and the additional switch QT. The secondary diodes DS1 and DS2 commutation each other.
Mode 3 (t3~t4): When the additional switch QT is turned off, the output capacitance of additional switch QT is charged by the input voltage, so the input voltage and the clamp capacitor voltage are applied to the transformer together (Vin + VCc). At the same time, iLK flows to the input side through the additional diode DA, the channel of the clamp switch QC, and the clamp capacitor CC. Accordingly, when iLK reaches 0, the voltage charged in the output capacitance of additional switch QT is discharged, and the voltage of clamp capacitor VCc is applies to the transformer. In turn, energy cannot be transferred to the secondary side and DS2 conducts by energy stored in the output inductor.
Mode 4 (t4~t5): As the output capacitance of additional switch QT is discharged, iLK is conducted through the channel of the clamp switch QC and body-diode of additional switch QT. Additionally, the transformer current iLK increases in the negative direction, as the clamp switch QC turns off, the output capacitance of clamp switch QC is charged and the output capacitance of main switch QM is discharged by iLk to achieve the zero-voltage switching. After this mode ends, mode 1 starts and the following operations repeat.

4.2. ZVS Analysis

In the case of the conventional active-clamp forward converter, the ZVS condition of the clamp switch QC is relatively easily achieved by the falling iLK at the transformer reset operation, and the ZVS condition of main switch QM is achieved, by iLK, which is been increased the negative direction peak. However, the range of achieving the ZVS condition of the main switch QM is relatively narrow due to the asymmetric current waveform as the offset of iLK is biased in the positive direction as a whole. Additionally, in the case of the three-switch active-clamp forward converter, the main switch QM and clamp switch QC can achieve the ZVS condition from each peak current of iLK before each switching operation, similar to the conventional active-clamp forward converter. For the additional switch QT, the ZVS condition can be achieved by the resonance of LM and Coss.QT during the transformer reset operation. However, main switch QM has the asymmetrical feature of the transformer having a slightly elevated offset in the positive direction compared to the conventional active-clamp forward converter. Due to this, main switch QM has a narrow ZVS compared to the conventional active-clamp forward converter range.
The proposed converter has a similar ZVS range as it features both topologies above. However, the primary side-switching element has lower voltage stress than the conventional active-clamp forward converter under the same transformer turn ratio condition. Therefore, it allows to use the relatively superior performance MOSFET which leads to a lower Coss of the MOSFET, and directly affects the ZVS condition achievement as in Equations (10)–(13).
1 2 L K i L M 2 ( t 5 ) 1 2 ( C o s s , Q M + C o s s , Q C ) ( V i n + V C c ) 2
i L M ( t 5 ) = V i n 2 ( L M + L K ) D T s
1 2 L K i L K 2 ( t 2 ) 1 2 ( C o s s , Q M + C o s s , Q C ) ( V i n ) 2
i L K ( t 2 ) = N S N P ( ( N S N P ) V i n ( 1 D ) 2 L o + V i n 2 ( L M + L K ) ) D T S + D V i n R
where iLM(t5) means the negative peak current of magnetizing inductance(LM), iLK(t2) means the positive peak current of leakage inductance(LK), and COSS means the output capacitance of each MOSFET. In addition, for the proposed converter, by operating the additional switch QT before turning-on the main switch QM, the body-diode conduction interval of QT is minimized and the MOSFET channel conduction interval is increased to minimize conduction losses. The discharge time of the switch QT is expressed as tzvs,QT in Equation (14). DL is described as much as duty is ahead. For this reason DL increases within a equation DL ≤ D2 − tzvs,QT.
t Z V S , Q T ( C o s s , Q T + C j , D A ) ( L M + L K ) V i n V C c

5. Design and Simulation for 800 W Charger

Prior to the experiment, the battery charger of the 800 W DC/DC converter for electric kickboard is verified and analyzed through simulation. 36 V (5 Ah) and 48 V (5 Ah) batteries are mainly applied to electric kickboards, and the charging current is up to 15 A. When to charge the battery, CC-CV control is required according to the characteristics of the battery, and the voltage/current control strategy is simplified as shown in Figure 8. The maximum power of 800 W is when the 48 V battery is charged, the output voltage is 53.3 V and the charging current is 15 A, and when the 36 V battery is charged, the maximum power is 600 W at the battery voltage of 40 V. Therefore, the performance is compared and verified for four conditions: output 27 V 15 A, 42 V 4.5 A, 53.3 V 15 A, and 56 V 4.5 A. The design of the main parameters is based on the voltage stress limit of 550 V (85% of the rated voltage of the 650 V FET) of the QM of the three-switch active-clamp forward converter to use the 600 V/650 V rated voltage MOSFET with excellent performance index. It is designed as shown in Table 1, and input/output specifications are also shown.
Since the voltage stress of the additional switch QT is fixed to input voltage, MOSFET which has 600 V rated voltage and a low Rds(on) is selected. Because the maximum voltage stress of DS1 is 200 V, the diode with 300 V rated voltage and excellent reverse recovery characteristics is selected for the secondary diode. The circuit is designed to enter the DCM mode in 4.5 A load condition, which is the point of slow charging when the charging rate exceeds 80% to reduce the switching loss. Thus, output inductance is selected as 27.8 uH. In addition, before the experiment, the effectiveness is verified through efficiency and loss analysis based on the simulation results as shown in Figure 9.
Through the analysis of simulation results, the proposed voltage-stress-controllable three-switch active-clamp has less overall loss compared to the conventional active-clamp forward converter can be seen. In particular, the proposed converter has significantly reduced switching loss compared to the conventional converter, despite the increase in the absolute number of elements due to the added additional switch QT, additional diode DA. In the fast-charging condition based on 36 V battery charging 27 V, 15 A (405 W), the switching loss is reduced by about 6.12 W, leads to an efficiency increase of about 1.5% can be expected, and in slow charging condition of 42 V, 4.5 A (189 W), is reduced by about 5.06 W, and an efficiency increase of about 2.7% can be expected. In addition, based on 48 V battery charging, under fast charging conditions of 53.3 V, 15 A (799.5 W), switching loss is reduced by about 7.6 W, so an efficiency increase of about 1% can be expected, and in slow charging condition of 56 V 4.5 A (252 W), by about 6.17 W switching loss is reduced, so about 2.5% efficiency increase can be expected. Under all load conditions, the average efficiency increase is expected to be approximately 1.9% due to reduced switching losses, and the result of efficiency is shown in Figure 10. Accordingly, the proposed converter can be expected to lead an overall increase in efficiency compared to the conventional converter.

6. Experimental Results

Based on the simulation verification results, in order to verify the validity from actual experiments, a voltage stress controllable three-switch active-clamp forward converter which is capable of charging both 36 V (5 Ah) and 48 V (5 Ah) batteries for electric kickboards has been implemented. In addition, the experimental conditions are shown in Figure 11, and the equipment used is shown in Table 2.
For a 36 V battery, 27 V 15 A load condition, the waveform is as shown in Figure 12. Under the condition of 36 V battery fast charging (27 V 15 A), even if the additional switch QT is continuously turned on, the maximum voltage of the set main switch does not exceed 550 V. Therefore, the proposed converter operates the same as the conventional active clamp forward converter. In this case, since the proposed converter employs lower voltage rated FET with smaller Rds(on), it can reduce conduction loss compared to the conventional converter.
For a 36 V battery, 42 V 4.5 A load condition, the waveform is as shown in Figure 13. Under the condition of slow charging of 36 V battery (42 V 4.5 A), the additional switch QT continues to conduct as it does not exceed the maximum voltage set by the MOSFET as in fast charging, and it operates same as the conventional active clamp forward converter. Therefore, as described above, compared to the conventional converter, the proposed converter can reduce conduction loss of MOSFET, and it can be confirmed that the switching loss can be reduced by operating in DCM mode during slow charging as intended in the design stage.
For a 48 V battery, 53.3 V 15 A load condition, the waveform is as shown in Figure 14. In the case of 48 V battery fast charging mode 53.3 V 15 A, it can be seen that the voltage stress of the main switch QM reaches 550 V, the maximum range sets as shown in Figure 14b. Therefore, it can be confirmed that the duty DT of the additional switch on the level that maintains the maximum voltage stress is increased and the duty of the additional switch QT is increased forward by the lead duty (DL), which guarantees the ZVS of the additional switch. Therefore, since the duty of the main switch QM is higher than the previous 36 V battery condition, the duty DT of the additional switch is slightly increased. Additionally, as shown in Figure 14d, when the additional switch QT is turned off, the voltage waveform of the secondary-side rectifier DS2 is additionally charged as much as VCC and then discharged.
For a 48 V battery, 56 V 4.5 A load condition, the waveform is as shown in Figure 15, The slow charging condition of the 48 V battery (56 V 4.5 A) is also the maximum voltage tracking control that maintains the set maximum voltage of 550 V as shown in Figure 15b, and the duty DT is increased accordingly. Switching loss can be reduced by operating in DCM mode at light load in the same manner as in the previous 36 V battery slow charging condition (42 V 4.5 A). Additionally, similar to the fast charging mode, the duty is advanced within the range that guarantees the ZVS of the additional switch QT.
It is noteworthy that the proposed converter has a problem which the voltage of clamp capacitor is additionally charged in the rectifier on the secondary side by mounting the additional switch QT and results an increase in voltage stress. However, when operating in DCM mode under light load as shown in Figure 15c,d, the voltage stress applied to the secondary rectifier has a similar level to the conventional one.
Therefore, it is possible to comparatively cancel out the critical disadvantage high voltage stress that occurs in the rectifier on the secondary side due to the advantage, gained by adding MOSFET on the primary side, which is a characteristic of the three-switch forward converter.
As a result of the experiment, the efficiency under each condition is shown in Figure 16. Similar to the simulation analysis, it is confirmed that the power loss occurring in each condition is reduced, leading to a relative increase in efficiency. In particular, by operating in DCM mode at the light load, the relative efficiency of the proposed converter could be further increased. Thus, the overall efficiency of the proposed converter could be improved by more than 2% compared to the conventional converter in the light load.

7. Conclusions

In this paper, an independent gate control technique is proposed to maximize the efficiency and improve the flexibility of the three-switch active-clamp forward converter. The proposed converter reduces the turn-off switching loss of the two additional switching elements by delaying the duty of the additional switch, and it can reduce the current stress of the added additional diode. In addition, by advancing the duty of the additional switch, the ZVS of the additional switch is ensured and the conduction loss is further reduced. Furthermore, a control method to follow the maximum voltage stress is applied to the proposed circuit by utilizing the rise in voltage stress, which is a disadvantage caused by the turn-off delay. As a result, the proposed converter has the advantages of both the conventional active-clamp forward converter and the three-switch active-clamp forward converter, and it can be flexibly used in wide input dc/dc applications such as dc/dc power supply and battery charging.

Author Contributions

Conceptualization, C.-E.K.; methodology, C.-E.K.; software, J.-W.L.; validation, J.-W.L.; formal analysis, J.-W.L. and C.-E.K.; investigation, J.-W.L.; resources, C.-E.K.; data curation, J.-W.L.; writing—original draft preparation, J.-W.L.; writing—review and editing, C.-E.K.; visualization, J.-W.L.; supervision, C.-E.K.; project administration, C.-E.K.; funding acquisition, C.-E.K. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) under Grant 2020R1AC2C1005737.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Harikumaran, J.; Vereczki, G.; Farkas, C.; Bauer, P. Comparison of quick charge technologies for electric vehicle introduction in Netherlands. In Proceedings of the IECON 2012, 38th Annual Conference on IEEE Industrial Electronics Society, Montreal, QC, Canada, 25–28 October 2012. [Google Scholar]
  2. Papamanolis, P.; Bortis, D.; Krismer, F.; Menzi, D.; Kolar, J.W. New EV battery charger PFC rectifier front-end allowing full power delivery in 3-phase and 1-phase operation. Electronics 2021, 10, 2069. [Google Scholar] [CrossRef]
  3. Pellegrino, G.; Armando, E.; Guglielmi, P. An integral battery charger with power factor correction for electric scooter. IEEE Trans. Power Electron. 2009, 25, 751–759. [Google Scholar] [CrossRef] [Green Version]
  4. Weigl, J.D.; Saidi, H. Inayati Design, testing and optimisation of a hydrogen fuel cell motorcycle for South East Asia. In Proceedings of the 2013 Eighth International Conference and Exhibition on Ecological Vehicles and Renewable Energies (EVER), Monte Carlo, Monaco, 27–30 March 2013; pp. 1–4. [Google Scholar]
  5. Dieter Weigl, J.; Henz, M.; Inayati; Saidi, H. Converted battery-powered electric motorcycle and hydrogen fuel cell-powered electric motorcycle in South East Asia: Development and performance test. In Proceedings of the Joint International Conference on Electric Vehicular Technology and Industrial, Mechanical, Electrical and Chemical Engineering (ICEVT & IMECE), Surakarta, Indonesia, 4–5 November 2015; pp. 1–4. [Google Scholar]
  6. Suwanapingkarl, P.; Buasai, S.; Paorung, C.; Loongthaisong, A.; Ritsuk, N.; Srivallop, K. The concept of ‘ePVScooter’ an electric scooter integrated with portable photovoltaic charger system. In Proceedings of the 2019 International Conference on Power, Energy and Innovations (ICPEI), Pattaya, Thailand, 16–18 October 2019; pp. 150–153. [Google Scholar]
  7. Arnaudov, D.; Tashkov, B.; Hristov, I.; Yutidzhiyan, I.; Kishkin, K. Studying Contactless Charging System for an Electric Scooter. In Proceedings of the 2021 29th National Conference with International Participation (TELECOM), Sofia, Bulgaria, 28–29 October 2021; pp. 108–112. [Google Scholar]
  8. Zhang, R.; Hanaoka, T. Deployment of electric vehicles in China to meet the carbon neutral target by 2060: Provincial disparities in energy systems, CO2 emissions, and cost effectiveness. Resour. Conserv. Recycl. 2021, 170, 105622. [Google Scholar] [CrossRef]
  9. Conte, F.V. Battery and battery management for hybrid electric vehicles: A review. E I. Elektrotechnik Und Inf. 2006, 123, 424–431. [Google Scholar] [CrossRef]
  10. Vayrynen, A.; Salminen, J. Lithium ion battery production. J. Chem. Thermodyn. 2012, 46, 80–85. [Google Scholar] [CrossRef]
  11. An, L.; Lu, D.D.C. Design of a single-switch DC/DC converter for a PV-battery-powered pump system with PFM+ PWM control. IEEE Trans. Ind. Electron. 2014, 62, 910–921. [Google Scholar] [CrossRef]
  12. Labbe, B.; Allard, B.; Lin-Shi, X.; Chesneau, D. An integrated sliding-mode buck converter with switching frequency control for battery-powered applications. IEEE Trans. Power Electron. 2012, 28, 4318–4326. [Google Scholar] [CrossRef]
  13. Zhang, J.; Huang, X.; Wu, X.; Qian, Z. A high efficiency flyback converter with new active clamp technique. IEEE Trans. Power Electron. 2010, 25, 1775–1785. [Google Scholar] [CrossRef]
  14. Kim, T.H.; Lee, S.J.; Choi, W. Design and control of the phase shift full bridge converter for the on-board battery charger of the electric forklift. In Proceedings of the 8th International Conference on Power Electronics—ECCE Asia, Jeju, Republic of Korea, 30 May–3 June 2011; pp. 2709–2716. [Google Scholar]
  15. Lim, C.Y.; Jeong, Y.; Lee, M.S.; Yi, K.H.; Moon, G.W. Half-Bridge Integrated Phase-Shifted Full-Bridge Converter With High Efficiency Using Center-Tapped Clamp Circuit for Battery Charging Systems in Electric Vehicles. IEEE Trans. Power Electron. 2020, 35, 4934–4945. [Google Scholar] [CrossRef]
  16. Rasouli, M.; Mehrasa, M.; Ganjavi, A.; Sadabadi, M.S.; Ghoreishy, H.; Ahmad, A.A. Lyapunov-Based Control Strategy for a Single-Input Dual-Output Three-Level DC/DC Converter. IEEE Trans. Ind. Electron. 2022, 1–9. [Google Scholar] [CrossRef]
  17. Ganjavi, A.; Gholinejad, H.R.; Mehrasa, M.; Ghoreishy, H.; Ahmad, A.A. Feedback–feedforward control technique with a comprehensive mathematical analysis for single-input dual-output three-level dc–dc converter. IET Power Electron. 2020, 13, 4685–4694. [Google Scholar] [CrossRef]
  18. Beiranvand, R.; Rashidian, B.; Zolghadri, M.R.; Alavi, S.M.H. Using LLC resonant converter for designing wide-range voltage source. IEEE Trans. Ind. Electron. 2010, 58, 1746–1756. [Google Scholar] [CrossRef]
  19. Kim, Y.D.; Cho, K.M.; Kim, D.Y.; Moon, G.W. Wide-range ZVS phase-shift full-bridge converter with reduced conduction loss caused by circulating current. IEEE Trans. Power Electron. 2012, 28, 3308–3316. [Google Scholar] [CrossRef]
  20. Lee, S.S.; Choi, S.W.; Moon, G.W. High-efficiency active-clamp forward converter with transient current build-up (TCB) ZVS technique. IEEE Trans. Ind. Electron. 2007, 54, 310–318. [Google Scholar] [CrossRef]
  21. Kim, M.H.; Lee, S.H.; Lee, B.S.; Kim, J.Y.; Kim, J.K. Double-Ended Active-Clamp Forward Converter with Low DC Offset Current of Transformer. IEEE Trans. Ind. Electron. 2020, 67, 1036–1047. [Google Scholar] [CrossRef]
  22. Park, K.B.; Kim, C.E.; Moon, G.W.; Youn, M.J. Multi-level active clamp forward converter with reduced voltage stress. In Proceedings of the 2008 IEEE Power Electronics Specialists Conference, Rhodes, Greece, 15–19 June 2008; pp. 938–943. [Google Scholar]
  23. Park, K.B.; Kim, C.E.; Moon, G.W.; Youn, M.J. Three-switch active-clamp forward converter with low switch voltage stress and wide ZVS range for high-input-voltage applications. IEEE Trans. Power Electron. 2009, 25, 889–898. [Google Scholar] [CrossRef]
  24. Kim, C.E.; Baek, J.; Lee, J.B. Improved three switch-active clamp forward converter with low switching and conduction losses. IEEE Trans. Power Electron. 2018, 34, 5209–5216. [Google Scholar] [CrossRef]
Figure 1. (a) Conventional active-clamp forward converter; (b) three-switch active-clamp forward converter.
Figure 1. (a) Conventional active-clamp forward converter; (b) three-switch active-clamp forward converter.
Micromachines 14 00035 g001
Figure 2. Voltage stress normalized by Vin (a) clamp capacitor; (b) main switch QM.
Figure 2. Voltage stress normalized by Vin (a) clamp capacitor; (b) main switch QM.
Micromachines 14 00035 g002
Figure 3. Simplified transformer waveform (a) active-clamp forward converter; (b) three-switch active- clamp forward converter.
Figure 3. Simplified transformer waveform (a) active-clamp forward converter; (b) three-switch active- clamp forward converter.
Micromachines 14 00035 g003
Figure 4. Simplified additional diode current waveform: (a) three-switch active-clamp forward converter; (b) proposed converter.
Figure 4. Simplified additional diode current waveform: (a) three-switch active-clamp forward converter; (b) proposed converter.
Micromachines 14 00035 g004
Figure 5. Voltage stress control circuit applied to the proposed converter.
Figure 5. Voltage stress control circuit applied to the proposed converter.
Micromachines 14 00035 g005
Figure 6. Operation modes of voltage controllable three-switch active-clamp forward converter: (a) Mode 1 (t1~t2), (b) Mode 2 (t2~t3), (c) Mode 3 (t3~t4), (d) Mode 4 (t4~t5).
Figure 6. Operation modes of voltage controllable three-switch active-clamp forward converter: (a) Mode 1 (t1~t2), (b) Mode 2 (t2~t3), (c) Mode 3 (t3~t4), (d) Mode 4 (t4~t5).
Micromachines 14 00035 g006
Figure 7. Key waveforms of the proposed converter.
Figure 7. Key waveforms of the proposed converter.
Micromachines 14 00035 g007
Figure 8. CC-CV control of 36 V and 48 V batteries for electric kickboard.
Figure 8. CC-CV control of 36 V and 48 V batteries for electric kickboard.
Micromachines 14 00035 g008
Figure 9. Simulation loss analysis: (a) conventional active-clamp forward converter; (b) proposed active-clamp forward converter.
Figure 9. Simulation loss analysis: (a) conventional active-clamp forward converter; (b) proposed active-clamp forward converter.
Micromachines 14 00035 g009
Figure 10. Simulation efficiency.
Figure 10. Simulation efficiency.
Micromachines 14 00035 g010
Figure 11. Experimental condition.
Figure 11. Experimental condition.
Micromachines 14 00035 g011
Figure 12. 36 V battery (27 V 15 A) load waveform: (a) conventional converter MOSFET voltage stress; (b) proposed converter MOSFET voltage stress; (c) conventional converter secondary rectifier voltage stress; (d) proposed converter secondary rectifier voltage stress; (e) conventional converter Vout; (f) proposed converter Vout.
Figure 12. 36 V battery (27 V 15 A) load waveform: (a) conventional converter MOSFET voltage stress; (b) proposed converter MOSFET voltage stress; (c) conventional converter secondary rectifier voltage stress; (d) proposed converter secondary rectifier voltage stress; (e) conventional converter Vout; (f) proposed converter Vout.
Micromachines 14 00035 g012
Figure 13. 36 V battery (42 V 4.5 A) load waveform: (a) conventional converter MOSFET voltage stress; (b) proposed converter MOSFET voltage stress; (c) conventional converter secondary rectifier voltage stress; (d) proposed converter secondary rectifier voltage stress; (e) conventional converter Vout; (f) proposed converter Vout.
Figure 13. 36 V battery (42 V 4.5 A) load waveform: (a) conventional converter MOSFET voltage stress; (b) proposed converter MOSFET voltage stress; (c) conventional converter secondary rectifier voltage stress; (d) proposed converter secondary rectifier voltage stress; (e) conventional converter Vout; (f) proposed converter Vout.
Micromachines 14 00035 g013
Figure 14. 48 V battery (53.3 V 15 A) load waveform: (a) conventional converter MOSFET voltage stress; (b) proposed converter MOSFET voltage stress; (c) conventional converter secondary rectifier voltage stress; (d) proposed converter secondary rectifier voltage stress; (e) conventional converter Vout; (f) proposed converter Vout.
Figure 14. 48 V battery (53.3 V 15 A) load waveform: (a) conventional converter MOSFET voltage stress; (b) proposed converter MOSFET voltage stress; (c) conventional converter secondary rectifier voltage stress; (d) proposed converter secondary rectifier voltage stress; (e) conventional converter Vout; (f) proposed converter Vout.
Micromachines 14 00035 g014
Figure 15. 48 V battery (56 V 4.5 A) load waveform: (a) conventional converter MOSFET voltage stress; (b) proposed converter MOSFET voltage stress; (c) conventional converter secondary rectifier voltage stress; (d) proposed converter secondary rectifier voltage stress; (e) conventional converter Vout; (f) proposed converter Vout.
Figure 15. 48 V battery (56 V 4.5 A) load waveform: (a) conventional converter MOSFET voltage stress; (b) proposed converter MOSFET voltage stress; (c) conventional converter secondary rectifier voltage stress; (d) proposed converter secondary rectifier voltage stress; (e) conventional converter Vout; (f) proposed converter Vout.
Micromachines 14 00035 g015
Figure 16. Experimental efficiency.
Figure 16. Experimental efficiency.
Micromachines 14 00035 g016
Table 1. Experimental parameters.
Table 1. Experimental parameters.
Input voltage, Vin385 VDC Nominal (380~405 VDC)
Output voltage, Vout27 V~56 V (36 V & 48 V Nominal)
Maximum output current Iout max15 A
Switching Frequency100 KHz
Topology typeThree-switch active-clamp forward converterActive-clamp forward converter
Main switch, QMIPW65R090CFD7IPW90R120C3
Clamp switch, QCIPP65R190CFD7IPP90R340C3
Additional switch, QTIPW60R018CFD7None
Transformer, TFPQ3230 (22:8 LM: 253 uH, LK: 14.1 uH)
Secondary side
rectifier diode
LQA30T300(300 V, 1.4 VF)
Output inductorCH270060 (LO: 27.8 uH)
Output capacitor80 V 47 uF, 4 EA
Table 2. Experimental equipment.
Table 2. Experimental equipment.
DC power sourceES 2000B, ES 2000S
Precision Power AnalyzerWT 5000
Electronic LoadPLZ1003WH
OscilloscopeWAVESURFER 3014Z
Current ProbeCP030A
Voltage ProbePP009-1
Differential ProbeHVD3106A
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Lim, J.-W.; Kim, C.-E. Drain-Source Voltage-Controllable Three-Switch Active-Clamp Forward Converter for Wide Input/Output Voltage Applications. Micromachines 2023, 14, 35. https://doi.org/10.3390/mi14010035

AMA Style

Lim J-W, Kim C-E. Drain-Source Voltage-Controllable Three-Switch Active-Clamp Forward Converter for Wide Input/Output Voltage Applications. Micromachines. 2023; 14(1):35. https://doi.org/10.3390/mi14010035

Chicago/Turabian Style

Lim, Jeong-Woo, and Chong-Eun Kim. 2023. "Drain-Source Voltage-Controllable Three-Switch Active-Clamp Forward Converter for Wide Input/Output Voltage Applications" Micromachines 14, no. 1: 35. https://doi.org/10.3390/mi14010035