Next Article in Journal
Laser Ultrasound Investigations of AlScN(0001) and AlScN(11-20) Thin Films Prepared by Magnetron Sputter Epitaxy on Sapphire Substrates
Next Article in Special Issue
Microfluidic Gas Sensors: Detection Principle and Applications
Previous Article in Journal
High-Speed Shift Register with Dual-Gated Thin-Film Transistors for a 31-Inch 4K AMOLED Display
Previous Article in Special Issue
Vertical Graphene-Based Biosensor for Tumor Cell Dielectric Signature Evaluation
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Adaptive Fiber-Ring Lasers Based on Isopropanol Filled Microfiber Coupler for High-Sensitivity Temperature Sensing

1
State Key Laboratory of Analog and Mixed-Signal VLSI, University of Macau, Macau 999078, China
2
Department of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen 518055, China
3
Department of Electrical and Computer Engineering, University of Macau, Macau 999078, China
4
Peng Cheng Laboratory, Shenzhen 518005, China
*
Authors to whom correspondence should be addressed.
Micromachines 2022, 13(10), 1697; https://doi.org/10.3390/mi13101697
Submission received: 17 September 2022 / Revised: 4 October 2022 / Accepted: 7 October 2022 / Published: 9 October 2022
(This article belongs to the Special Issue Micro- and Nano-Systems for Manipulation, Actuation and Sensing)

Abstract

:
We demonstrated a new method for temperature measurement inside a fiber ring laser (FRL) cavity. Different from traditional FRL temperature sensing system which need additional filter working as a sensor, a micro-fiber coupler (MFC) was designed as a beam splitter, filter, and temperature sensor. In addition, isopropanol, a liquid with very high photothermal coefficient, is selectively filled in the MFC in order to improve the sensitivity of the system on temperature. In the dynamic range of 20–40 °C, we obtained a good temperature sensitivity of −1.29 nm/°C, with linear fitting up to 0.998. Benefiting from the advantages of laser sensing, the acquired laser has a 3 – dB bandwidth of less than 0.2 nm and a signal-to-noise ratio (SNR) of up to 40 dB. The proposed sensor has a low cost and high sensitivity, which is expected to be used in biomedical health detection, real-time monitoring of ocean temperature, and other application scenarios.

1. Introduction

Optical fiber sensors have been widely recognized after decades of development [1,2,3,4,5]. Differently from traditional electronic sensors, optical fiber has its own indispensable advantages, including but not limited to: electrical insulation, corrosion resistance, variable shape, small size, wide range of measuring objects, and easy reuse [6,7,8,9,10]. Among them, temperature, as the most important parameter for perceiving the external environment, has received the most extensive attention from scientists, and has been widely researched [11,12,13]. Various optical fiber structures have been designed to improve the sensitivity, stability, and practicability of temperature sensing [14,15,16]. Common structures include Mach Zehnder Interferometer (MZI), Fabry Perot Interferometer (FPI), Sagnac Ring, and Fiber Bragg Grating (FBG) [17,18,19,20]. However, due to the characteristics of broadband light sources, there are some unavoidable defects, such as low signal-to-noise ratio and large linewidth, which will cause measurement errors.
In recent years, MFC has been noticed. It has been found that after two ordinary single-mode optical fibers are fused and pulled to one MFC, interference will occur. High sensitivity temperature monitoring can be achieved by filling liquid with a high photothermal coefficient. Wang et al. immersed micro/nano optical fibers in seawater for a dual parameter measurement of salinity and temperature [21]. In order to maintain a stable structure in liquid, they proposed a method of ethyl cellulose ethanol film coating. By coating the coupling region with ethyl cellulose ethanol solvent, it can operate stably in seawater. The temperature sensitivity is −1.13 nm/°C. However, the signal intensity of this structure is below 70 dB, leading to questions about the practicability of monitoring in the real marine environment. Zhao’s and Jian’s group proposed an ultra-high sensitivity optical fiber temperature sensing system based on alcohol filling almost at the same time [22,23]. The temperature sensitivity up to 5 nm/°C was achieved through biconical fiber taper coupling, capillary encapsulation, and isopropanol filling. However, large bandwidth may cause potential measurement errors, and it is still possible to continue improving.
In the past decade, a sensing system based on fiber ring laser cavity has been gradually attracting attention. It is independent of a broadband light source, and has advantages including narrow linewidth, high signal-to-noise ratio, and no burr. Fukushima et al. proposed a dual-pass cascaded-chirped long-period fiber grating as a reflective sensor device, and a wavelength selection element with comb spectrum to achieve a temperature sensor based on erbium-doped fiber laser, achieving a temperature sensitivity of 0.2 nm/°C [24]. However, the cascade structure is complex, not only increasing the system cost but also reducing the stability at the same time. In addition, Lin et al. discovered the vernier effect in the fiber laser cavity by cascading Sagnac rings, which increased the temperature sensitivity by more than four times. However, the complex structure design reduced the signal-to-noise ratio of the system [25]. In the past two years, researchers have gradually realized that the MFC formed by melting two single-mode optical fibers into a taper can replace the coupler of the traditional process to operate in the FRL system. All work is focused on achieving ultra-fast lasers by coating MFC with saturable absorption [26,27,28,29]. As far as we know, the FRL system based on MFC for sensor systems has not been reported yet.
In this letter, differently from the traditional FRL temperature sensing system, we combined the advantage of MCF and the laser cavity. The MFC works as a sensing element, filter, and coupler. In addition, the isopropanol with ultra-high photothermal coefficient is selectively filled into MFC in order to improve the temperature sensing response characteristics. The manufacturing process and working principle are introduced in detail, and the corresponding temperature characteristics of −1.29 nm/°C in the range of 20 °C–30 °C at the interval of 1 °C are realized. The sensitivity of −1.2 nm/°C is within the range of 20 °C–40 °C, with an interval of 5 °C. Thanks to the characteristics of laser, the signal-to-noise ratio of the designed sensing system is up to 35 dB, and the 3 – dB bandwidth is better than 0.2 nm. The stability of the structure was tested for 3 h, and the wavelength and intensity shift were better than 0.2 nm and 1 dB, respectively. This is of great potential value for the sensors to be used for life and health temperature monitoring, as well as real-time monitoring of ocean temperature.

2. Sensor Setup and Principle

Figure 1 shows the basic structure of MFC. It consists of three parts: cone, transition, and input and output. When broadband light is emitted to MFC, the lowest order even mode and odd mode are excited simultaneously. Energy is periodically transmitted back and forth between the two modes. The coupling coefficient C between them reciprocates, as shown in formula [22]:
C = 3 π λ 32 n 1 a 2 · 1 ( 1 + 1 V ) 2
where a is the diameter of MFC and λ is the central wavelength of incident light. V is the normalized frequency, and its expression is [23]:
V = 2 π a λ n 1 2 n 2 2
in which n 1 and n 2 is the refractive index of input isopronal and fiber. The actual power in the output side can be expressed as [22]:
P = P 0 s i n 2 ( C L )
wherein P 0 represents the total power of the input light and P represents the output power of the light. L is the mutual transmission length of MFC internal modes. The output power depends on the surrounding refractive index, as well as the size and length of the micro nano fiber.
However, the thinner the micro nano fiber is, the greater its loss is. We used an optical fiber taper machine (AFBT-8000, Kepler, Shandong, China) to place two optical fibers in the groove in parallel, and turned on the vacuum pump in order to cause the optical fibers to stick closely to the machine. A common single-mode optical fiber is shown in Figure 2a, and its diameter is 125 microns. By setting the taper distance to 2.3 cm, we have achieved an MFC with a fiber core diameter of 10 microns, two fibers tightly fused and capable of producing interference effects, as shown in Figure 2b. The thinner size is limited by the loss, and cannot generate laser in the experiment. Therefore, the MFC diameter of 10 microns was selected for this experiment.
Isopropanol has a very high photothermal response, and its refractive index decreases significantly when the temperature rises. Therefore, effectively filling the liquid can greatly improve the temperature sensitivity. The pre-experiment is shown in Figure 3. Using a broadband light source (Hoyatek ASE-C-N, Shenzhen, China), the isopropanol filled MCF structure was connected, the structure was heated through a thermostat, and, finally, an optical spectrum analyzer (OSA, Yokogawa AQ6370D, Japan) was connected at one of the output ports.
The formal experimental test is shown in Figure 4. The 980 nm pump light source (PL-974-500-FC/APC-P-M, Shenzhen, China) generated the pump light into the annular cavity through the wavelength division multiplexer. The light was amplified by erbium-doped fiber, and the laser near 1550 nm was pumped. The laser interference generated by MFC structure was modulated by temperature. Part of the light was input into OSA, and the polarization controller was used to adjust the polarization state in order to achieve a high power laser output. In addition, the isolator was used to prevent the backscattered light from damaging other devices in the circulator. When the temperature changed, the energy transmitted in the MFC transferred, and the interference peak shift acted as a tunable filter to output lasers of different wavelengths.

3. Experimental Results

First, in order to test the performance of the interferometer, the broadband light source was used to test the interferometer in the range of 20–30 °C. The broadband light source entered from one port of the coupler, and one of the output terminals was connected to the OSA. The interval between each temperature is 1 °C, and the test interval is 20 min long, to ensure good thermal conductivity. The test results are shown in Figure 5. It is obvious that with the increase of temperature, there is a blue shift to a short wavelength on the spectrum. We intend to further analyze the sensitivity and linear relationship of the sensor. The linear fitting of spectra at different temperatures is shown in Figure 6. According to the figure, the detection sensitivity is up to −1.29 nm/°C, which is an order of magnitude higher than the sensitivity of an ordinary optical fiber temperature sensor. Moreover, the fitting coefficient is up to 0.999, showing excellent linearity, which proves the feasibility of working in this temperature range.
The dynamic range of the designed sensing system was further measured, and the temperature measurement range was expanded from 20 °C to 40 °C at 5 °C intervals. The spectrum picture shown in Figure 7 was obtained, and it can be observed that there was a gradual overlap between the spectra with the increase of temperature. Therefore, the temperature response range could not be further expanded. The effective measurement range is 20 °C to 40 °C. The sensitivity remains at −1.2 nm/°C. The linear fitting curve is shown in Figure 8, and the R square is equal to 0.998. This proves that the feasibility of the sensor as a temperature detection instrument provides a basis for the next step of laser detection.
Then, we first coupled the interference spectrum and laser spectrum at 20 °C, as shown in Figure 9. It can be found that the peak value of the interference spectrum corresponds to the spectrum of the laser output. It has been proven that MFC works well as a filter and as a coupler. At the same time, it can be observed that the linewidth is less than 0.2 nm and the signal-to-noise ratio is as high as 35 dB. Therefore, we formally monitored the temperature through the FRL system. The test results are shown in Figure 10. It can be found that the wavelength is still blue shifted. The linear fitting curve is shown in Figure 11, and the sensitivity is up to −1.29 nm/°C, which is consistent with broadband light sources. In addition, the R square is 0.998, demonstrating the reliability of the sensing system.
Similarly, we measured the temperature in a larger dynamic range, from 20 °C to 40 °C at 5 °C intervals. The temperature corresponding curve and the linear fitting curve are shown in Figure 12 and Figure 13. The sensitivity is up to −1.2 nm/°C. At the same time, the linear fitting degree is kept at 0.997, realizing the wide range of ultra-high sensitivity temperature response. The sensitivity obtained in the experiment is identical to that of the broadband light source, but it retains the characteristics of the laser, namely, narrow linewidth and high signal-to-noise ratio.
When evaluating the quality of a sensor, its stability should be considered in addition to its sensitivity. This experiment also measured the stability of the laser structure, as shown in Figure 14. Within 3 h, the wavelength shift range was less than 0.2 nm, and the intensity change was better than 1 dB. Table 1 also compares the sensitivity of the temperature sensors of different structures. It can be found that the designed temperature sensor system is more than an order of magnitude higher than the traditional structure.
In order to verify the temperature response characteristics of isopropanol, we tested the change in the isopropanol refractive index at different temperatures through the refractometer, as shown in Figure 15.

4. Conclusions

In this study, we proposed a new method for ultra-high temperature measurement. This is the first time that an MFC has been reported to work as a coupler, filter, and sensing system, differently from the traditional FRL temperature sensing system. This new method can reduce cost and improve stability. Thanks to the high photothermal coefficient of isopropanol, the temperature sensitivity is −1.29 nm/°C at a range of 20 °C–30 °C, and −1.2 nm/°C at a range of 20 °C–40 °C. Moreover, benefiting from the FRL system itself, the system has high SNR (−35 dB) and narrow 3 – dB bandwidth (−0.2 nm). This kind of temperature sensor can be used in biomedical engineering and marine temperature detection.

Author Contributions

Conceptualization, W.L. and Y.L.; methodology, W.L.; software, F.Z.; validation, J.H.; formal analysis, F.Y.; investigation, S.L.; resources, W.L.; data curation, W.L.; writing—original draft preparation, S.S.; writing—review and editing, S.-H.P. and P.-U.M.; visualization, P.-P.S.; supervision, M.-I.V. and L.S.; funding acquisition, L.S. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the startup fund from Southern University of Science and Technology and the Shenzhen government.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

Thanks to the Lips team for their help and support to the whole experiment.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Zhuo, L.; Tang, J.; Zhu, W.; Zheng, H.; Guan, H.; Lu, H.; Chen, Y.; Luo, Y.; Zhang, J.; Zhong, Y.; et al. Side Polished Fiber: A Versatile Platform for Compact Fiber Devices and Sensors. Photonic Sens. 2022, 13, 230120. [Google Scholar] [CrossRef]
  2. Amendola, V.; Pilot, R.; Frasconi, M.; Marago, O.M.; Iati, M.A. Surface plasmon resonance in gold nanoparticles: A review. J. Phys. Condens. Matter. 2017, 29, 203002. [Google Scholar] [CrossRef] [PubMed]
  3. Mihailov, S.J. Fiber Bragg grating sensors for harsh environments. Sensors 2012, 12, 1898–1918. [Google Scholar] [CrossRef] [PubMed]
  4. Majumder, M.; Gangopadhyay, T.K.; Chakraborty, A.K.; Dasgupta, K.; Bhattacharya, D.K. Fibre Bragg gratings in structural health monitoring—Present status and applications. Sens. Actuators A Phys. 2008, 147, 150–164. [Google Scholar] [CrossRef]
  5. Fan, X.; White, I.M.; Shopova, S.I.; Zhu, H.; Suter, J.D.; Sun, Y. Sensitive optical biosensors for unlabeled targets: A review. Anal. Chim. Acta 2008, 620, 8–26. [Google Scholar] [CrossRef]
  6. Persano, L.; Dagdeviren, C.; Su, Y.; Zhang, Y.; Girardo, S.; Pisignano, D.; Huang, Y.; Rogers, J.A. High performance piezoelectric devices based on aligned arrays of nanofibers of poly(vinylidenefluoride-co-trifluoroethylene). Nat. Commun. 2013, 4, 1633. [Google Scholar] [CrossRef] [Green Version]
  7. Liu, X.; Qu, C.; Zhou, S.; Cao, W.; Xu, M.; Liu, Y. Simple and stable gas–liquid two-phase optical fiber sensor for acetone based on cholesteric liquid crystal. Opt. Commun. 2023, 526, 128890. [Google Scholar] [CrossRef]
  8. Jaworski, P.; Krzempek, K.; Bojęś, P.; Wu, D.; Yu, F. Mid-IR antiresonant hollow-core fiber based chirped laser dispersion spectroscopy of ethane with parts per trillion sensitivity. Opt. Laser Technol. 2022, 156, 108539. [Google Scholar] [CrossRef]
  9. Fu, X.; Huang, Z.; Li, Q.; Cao, X.; Wang, Y.; Fu, G.; Jin, W.; Bi, W. A cascaded triple waist-enlarged taper few-mode fiber temperature sensor with beaded structure. Opt. Laser Technol. 2022, 156, 108621. [Google Scholar] [CrossRef]
  10. Su, Y.D.; Preger, Y.; Burroughs, H.; Sun, C.; Ohodnicki, P.R. Fiber Optic Sensing Technologies for Battery Management Systems and Energy Storage Applications. Sensors 2021, 21, 1397. [Google Scholar] [CrossRef]
  11. Lin, W.; Liu, Y.; Shao, L.; Vai, M.I. A Fiber Ring Laser Sensor with a Side Polished Evanescent Enhanced Fiber for Highly Sensitive Temperature Measurement. Micromachines 2021, 12, 568. [Google Scholar] [CrossRef] [PubMed]
  12. Zhao, F.; Xiao, D.; Lin, W.; Chen, Y.; Wang, G.; Hu, J.; Liu, S.; Yu, F.; Xu, W.; Yang, X.; et al. Sensitivity Enhanced Refractive Index Sensor With In-Line Fiber Mach-Zehnder Interferometer Based on Double-Peanut and Er-Doped Fiber Taper Structure. J. Lightwave Technol. 2022, 40, 245–251. [Google Scholar] [CrossRef]
  13. Lin, W.; Zhao, F.; Shao, L.-Y.; Vai, M.I.; Shum, P.P.; Sun, S. Temperature Sensor Based on Er-Doped Cascaded-Peanut Taper Structure In-Line Interferometer in Fiber Ring Laser. IEEE Sens. J. 2021, 21, 21594–21599. [Google Scholar] [CrossRef]
  14. Zhang, G.; Ge, Q.; Wang, H.; Wu, X.; Yu, B. High precision temperature and strain discrimination using TCF–TPMF fiber structure based Sagnac interferometer. Opt. Commun. 2022, 522, 128634. [Google Scholar] [CrossRef]
  15. Gillespie, D.I.; Hamilton, A.W.; Atkinson, R.C.; Bellekens, X.; Michie, C.; Andonovic, I.; Tachtatzis, C. Composite Laminate Delamination Detection Using Transient Thermal Conduction Profiles and Machine Learning Based Data Analysis. Sensors 2020, 20, 7227. [Google Scholar] [CrossRef] [PubMed]
  16. Su, B.; Qi, B.; Zhang, F.; Zhong, L.; Xu, O.; Qin, Y. Hybrid fiber interferometer sensor for simultaneous measurement of strain and temperature with refractive index insensitivity. Opt. Commun. 2022, 522, 128637. [Google Scholar] [CrossRef]
  17. Yuan, W.; Zhao, Q.; Li, L.; Wang, Y.; Yu, C. Simultaneous measurement of temperature and curvature using ring-core fiber-based Mach-Zehnder interferometer. Opt. Express 2021, 29, 17915–17925. [Google Scholar] [CrossRef] [PubMed]
  18. Kanawade, R.; Kumar, A.; Pawar, D.; Late, D.; Mondal, S.; Sinha, R.K. Fiber optic Fabry–Perot interferometer sensor: An efficient and fast approach for ammonia gas sensing. J. Opt. Soc. Am. B 2019, 36, 684–689. [Google Scholar] [CrossRef]
  19. Sun, L.P.; Yuan, Z.; Huang, T.; Sun, Z.; Lin, W.; Huang, Y.; Xiao, P.; Yang, M.; Li, J.; Guan, B.O. Ultrasensitive sensing in air based on Sagnac interferometer working at group birefringence turning point. Opt. Express 2019, 27, 29501–29509. [Google Scholar] [CrossRef]
  20. Raju, S.D.V.S.J.; Hague, S.M.; Goud, B.K.; De, R.; Misal, J.S.; Rao, K.D. Fiber Bragg grating sensor for in situ substrate temperature measurement in a magnetron sputtering system. Phys. Scr. 2022, 97, 095505. [Google Scholar] [CrossRef]
  21. Wang, S.; Yang, H.; Liao, Y.; Wang, X.; Wang, J. High-Sensitivity Salinity and Temperature Sensing in Seawater Based on a Microfiber Directional Coupler. IEEE Photonics J. 2016, 8, 593586. [Google Scholar] [CrossRef]
  22. Zhao, L.; Zhang, Y.; Wang, J.; Chen, Y. Highly sensitive temperature sensor based on an isopropanol-sealed optical microfiber coupler. Appl. Phys. Lett. 2018, 113, 111901. [Google Scholar] [CrossRef]
  23. Jiang, Y.; Fang, Z.; Du, Y.; Lewis, E.; Farrell, G.; Wang, P. Highly sensitive temperature sensor using packaged optical microfiber coupler filled with liquids. Opt. Express 2018, 26, 356–366. [Google Scholar] [CrossRef] [Green Version]
  24. Fukushima, K.; Wada, A.; Tanaka, S.; Ito, F. EDF laser temperature sensor using double-pass cascaded-chirped long-period fiber grating in sigma-cavity configuration. Opt. Commun. 2022, 508, 127713. [Google Scholar] [CrossRef]
  25. Lin, W.; Shao, L.; Yibin, L.; Bandyopadhyay, S.; Yuhui, L.; Weijie, X.; Shuaiqi, L.; Jie, H.; Vai, M.I. Temperature Sensor Based on Fiber Ring Laser With Cascaded Fiber Optic Sagnac Interferometers. IEEE Photonics J. 2021, 13, 3065567. [Google Scholar] [CrossRef]
  26. Chen, J.H.; Deng, G.Q.; Yan, S.C.; Li, C.; Xi, K.; Xu, F.; Lu, Y.Q. Microfiber-coupler-assisted control of wavelength tuning for Q-switched fiber laser with few-layer molybdenum disulfide nanoplates. Opt. Lett. 2015, 40, 3576–3579. [Google Scholar] [CrossRef] [Green Version]
  27. Shaodong, H.; Zhijian, M.; Junbo, Y.; Min, Z.; Peiguang, Y.; Shuangchen, R. Mode-locked Er-doped fiber laser based on function-integrated fiber coupler. Opt. Lett. 2021, 46, 5934–5937. [Google Scholar] [CrossRef] [PubMed]
  28. Wang, Y.; Hou, S.; Yu, Y.; Liu, W.; Yan, P.; Yang, J. Photonic device combined optical microfiber coupler with saturable-absorption materials and its application in mode-locked fiber laser. Opt. Express 2021, 29, 20526–20534. [Google Scholar] [CrossRef]
  29. Azlan Sulaiman, A.S.; Sulaiman Wadi Harun, S.W.H.; Harith Ahmad, H.A. Ring microfiber coupler erbium-doped fiber laser analysis. Chin. Opt. Lett. 2014, 12, 021403–21406. [Google Scholar] [CrossRef] [Green Version]
  30. Xiao, S.Y.; Wu, B.L.; Sun, C.R.; Wang, Z.X.; Jiang, Y.C. Strain and Temperature Discrimination Based on a Mach-Zehnder Interferometer with Cascaded Single Mode Fibers. Photonic Sens. 2023, 13, 230122. [Google Scholar] [CrossRef]
  31. Gao, P.; Zheng, X.; Liu, Y.; Wang, Z. Photonic crystal fiber refractive index temperature sensor based on double spherical cascade. Optik 2022, 267, 169682. [Google Scholar] [CrossRef]
  32. Liu, C.; Zhang, Y.; Li, X.; Fan, X.; Chen, Q.; Wu, B.; Chen, H. A gold film coated dual-core photonic crystal fiber for refractive index and temperature sensing with high isolation. Opt. Fiber Technol. 2022, 72, 102975. [Google Scholar] [CrossRef]
  33. Lebarck Pizzaia, J.P.; Schmidt Castellani, C.E.; Gomes Leal-Junior, A. Highly sensitive temperature sensing based on a birrefringent fiber Sagnac loop. Opt. Fiber Technol. 2022, 72, 102949. [Google Scholar] [CrossRef]
Figure 1. Schematic diagram of tapered MFC.
Figure 1. Schematic diagram of tapered MFC.
Micromachines 13 01697 g001
Figure 2. (a) Micrograph of single-mode optical fiber; (b) micrograph of MFC structure after drawing.
Figure 2. (a) Micrograph of single-mode optical fiber; (b) micrograph of MFC structure after drawing.
Micromachines 13 01697 g002
Figure 3. Experimental setup diagram of MCF temperature sensor under broadband light source.
Figure 3. Experimental setup diagram of MCF temperature sensor under broadband light source.
Micromachines 13 01697 g003
Figure 4. Experimental setup diagram of MCF temperature sensor under fiber ring laser sensing system.
Figure 4. Experimental setup diagram of MCF temperature sensor under fiber ring laser sensing system.
Micromachines 13 01697 g004
Figure 5. Output spectrum of temperature response with broadband light source (BBS) in the range of 20–30 °C within 1 °C per interval.
Figure 5. Output spectrum of temperature response with broadband light source (BBS) in the range of 20–30 °C within 1 °C per interval.
Micromachines 13 01697 g005
Figure 6. Linear fitting under BBS (20–30 °C).
Figure 6. Linear fitting under BBS (20–30 °C).
Micromachines 13 01697 g006
Figure 7. Output spectrum of temperature response with BBS in the range of 20–40 °C within 5 °C per interval.
Figure 7. Output spectrum of temperature response with BBS in the range of 20–40 °C within 5 °C per interval.
Micromachines 13 01697 g007
Figure 8. Linear fitting curve under BBS (20–40 °C).
Figure 8. Linear fitting curve under BBS (20–40 °C).
Micromachines 13 01697 g008
Figure 9. Fitting diagram of interference spectrum and laser spectrum.
Figure 9. Fitting diagram of interference spectrum and laser spectrum.
Micromachines 13 01697 g009
Figure 10. Different output spectra of the laser, varying with temperature (20–30 °C; interval is 1 °C).
Figure 10. Different output spectra of the laser, varying with temperature (20–30 °C; interval is 1 °C).
Micromachines 13 01697 g010
Figure 11. Linear fitting curve of laser changes with temperature (20–30 °C; interval is 1 °C).
Figure 11. Linear fitting curve of laser changes with temperature (20–30 °C; interval is 1 °C).
Micromachines 13 01697 g011
Figure 12. Different output spectra of the laser, varying with temperature (20–40 °C; interval is 5 °C).
Figure 12. Different output spectra of the laser, varying with temperature (20–40 °C; interval is 5 °C).
Micromachines 13 01697 g012
Figure 13. Linear fitting curve of laser changes with temperature (20–40 °C; interval is 5 °C).
Figure 13. Linear fitting curve of laser changes with temperature (20–40 °C; interval is 5 °C).
Micromachines 13 01697 g013
Figure 14. Amplitude diagram of the wavelength and intensity shift within 3 h at 20 °C.
Figure 14. Amplitude diagram of the wavelength and intensity shift within 3 h at 20 °C.
Micromachines 13 01697 g014
Figure 15. Temperature dependence curve of refractive index of isopropanol.
Figure 15. Temperature dependence curve of refractive index of isopropanol.
Micromachines 13 01697 g015
Table 1. The sensitivity of temperature sensors of different structures.
Table 1. The sensitivity of temperature sensors of different structures.
StructuresSensitivity (nm/°C)Refs.
Peanut-shaped MZI0.049[30]
Double spherical cascade0.306[31]
Gold-filled PCF1.3[32]
Sagnac loop1.59[33]
MFC1.29This work
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Lin, W.; Hu, J.; Zhao, F.; Sun, S.; Liu, Y.; Liu, S.; Yu, F.; Mak, P.-U.; Pun, S.-H.; Shum, P.-P.; et al. Adaptive Fiber-Ring Lasers Based on Isopropanol Filled Microfiber Coupler for High-Sensitivity Temperature Sensing. Micromachines 2022, 13, 1697. https://doi.org/10.3390/mi13101697

AMA Style

Lin W, Hu J, Zhao F, Sun S, Liu Y, Liu S, Yu F, Mak P-U, Pun S-H, Shum P-P, et al. Adaptive Fiber-Ring Lasers Based on Isopropanol Filled Microfiber Coupler for High-Sensitivity Temperature Sensing. Micromachines. 2022; 13(10):1697. https://doi.org/10.3390/mi13101697

Chicago/Turabian Style

Lin, Weihao, Jie Hu, Fang Zhao, Siming Sun, Yuhui Liu, Shuaiqi Liu, Feihong Yu, Peng-Un Mak, Sio-Hang Pun, Perry-Ping Shum, and et al. 2022. "Adaptive Fiber-Ring Lasers Based on Isopropanol Filled Microfiber Coupler for High-Sensitivity Temperature Sensing" Micromachines 13, no. 10: 1697. https://doi.org/10.3390/mi13101697

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop