Next Article in Journal
Motility of Adherent Hemocytes as a Potential Marker of Immunocompetence and Immunotoxic Effects in Bivalves
Previous Article in Journal
Biochemical and Histological Changes in Liver and Kidney in Male Wistar Albino Rats Following Exposure to Solignum®: A Permethrincontaining Wood Preservative
 
 
Journal of Xenobiotics is published by MDPI from Volume 10 Issue 1 (2020). Previous articles were published by another publisher in Open Access under a CC-BY (or CC-BY-NC-ND) licence, and they are hosted by MDPI on mdpi.com as a courtesy and upon agreement with PAGEPress.
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Quick and Easy Method for Determination of Priority Phenolic Compounds in Water and Wastewater

National Reference Trace Organics Laboratory, Central Pollution Control Board, East Arjun Nagar Delhi, India
J. Xenobiot. 2014, 4(1), 4680; https://doi.org/10.4081/xeno.2014.4680
Submission received: 27 August 2014 / Revised: 21 November 2014 / Accepted: 21 November 2014 / Published: 18 December 2014

Abstract

Phenols and phenolic compounds are ubiquitous contaminants in the environment. Due to toxic potential, some phenolic compounds mainly chlorophenols and nitrophenols have been classified as priority pollutants. They enter into the environment through various sources such as industrial, domestic and vehicular emissions. For compliance of national and international regulations, various analytical methods have been developed for assessment in the environmental matrices. This paper presents quick, easy and reliable method for simultaneous determination of eleven priority phenolic compounds in wastewater using reversed-phase high-performance liquid chromatography and diode array detector. Liquid-liquid extraction technique with dichloromethane in acidic condition was used for the extraction, and chromatographic separation of compounds was carried out on a C18 column with water and methanol as the mobile phase. The following parameters like selectivity/ specificity, linearity (R2), range, limit of detection (LOD) and quantification (LOQ), precision (repeatability) and accuracy (recovery) were validated for consistent and reliable results. Calibration curves for all compounds were linear (R2, 0.998-0.999) within the concentration range of 5-125 (μg/mL). The LOD and LOQ of the method ranged between 0.11- 0.61 μg/L and 0.37-2.04 μg/L, respectively. This method was applied to quantify phenolic compounds in wastewater samples from urban drain with good separated peaks, precision and accuracy.
Keywords: Priority phenolic compounds; highperformance liquid chromatography; method development; wastewater Priority phenolic compounds; highperformance liquid chromatography; method development; wastewater

Share and Cite

MDPI and ACS Style

Kumar, B. Quick and Easy Method for Determination of Priority Phenolic Compounds in Water and Wastewater. J. Xenobiot. 2014, 4, 4680. https://doi.org/10.4081/xeno.2014.4680

AMA Style

Kumar B. Quick and Easy Method for Determination of Priority Phenolic Compounds in Water and Wastewater. Journal of Xenobiotics. 2014; 4(1):4680. https://doi.org/10.4081/xeno.2014.4680

Chicago/Turabian Style

Kumar, Bhupander. 2014. "Quick and Easy Method for Determination of Priority Phenolic Compounds in Water and Wastewater" Journal of Xenobiotics 4, no. 1: 4680. https://doi.org/10.4081/xeno.2014.4680

Article Metrics

Back to TopTop