Article

Durability of Construction and Demolition Waste-Bearing Ternary Eco-Cements

by
Jaime Moreno-Juez
1,
Laura Caneda-Martínez
2,
Raquel Vigil de la Villa
3,
Iñigo Vegas
1 and
Moisés Frías
2,*
1
Tecnalia, Basque Research and Technology Alliance (BRTA), Astondo Bidea, Edificio 700, Parque Tecnológico de Bizkaia, 48160 Derio, Spain
2
Eduardo Torroja Institute for Construction Science (IETcc-CSIC), 28033 Madrid, Spain
3
Departamento de Geología y Geoquímica, Geomateriales Unidad Asociada CSIC-UAM, Universidad Autónoma de Madrid, 28049 Madrid, Spain
*
Author to whom correspondence should be addressed.
Materials 2022, 15(8), 2921; https://doi.org/10.3390/ma15082921
Submission received: 7 March 2022 / Revised: 12 April 2022 / Accepted: 14 April 2022 / Published: 16 April 2022
(This article belongs to the Special Issue Development and Research of Cementitious Materials)

Abstract

:
In recent years, the development of ternary cements has become a priority research line for obtaining cements with a lower carbon footprint, with the goal to contribute to achieve climate neutrality by 2050. This study compared ordinary Portland cement (OPC) durability to the performance of ternary cements bearing OPC plus 7% of a 2:1 binary blend of either calcareous (Hc) or siliceous (Hs) concrete waste fines and shatterproof glass. Durability was measured further to the existing legislation for testing concrete water absorption, effective porosity, pressurized water absorption and resistance to chlorides and CO2. The experimental findings showed that the 7% blended mortars performed better than the reference cement in terms of total and effective porosity, but they absorbed more pressurized water. They also exhibited lower CO2 resistance, particularly in the calcareous blend, likely due to its higher porosity. Including the binary blend of CDW enhanced chloride resistance with diffusion coefficients of 2.9 × 10−11 m2 s−1 (calcareous fines-glass, 7%Hc-G) and 1.5 × 10−11 m2 s−1 (siliceous fines-glass, 7%Hs-G) compared to the reference cement’s 4.3 × 10−11 m2 s−1. The siliceous fines-glass blend out-performed the calcareous blend in all the durability tests. As the mortars with and without CDW (construction and demolition waste) performed to similar standards overall, the former were deemed viable for the manufacture of future eco-efficient cements.

1. Introduction

Given the vast volumes of construction and demolition waste (CDW) generated yearly, it is one of the streams of refuse presently attracting the interest of both the scientific community and the construction industry. The 900 million tonnes of CDW produced in Europe in 2015 [1] accounted for one-third of all the waste generated in the region that year. Although a mean 35% was valorized in a number of industrial applications [2], the rest posed, and continues to pose, severe technical, economic, environmental and social problems [3]. In response to those issues, solutions have been proposed to improve construction industry sustainability [4] in keeping with circular economy strategies, such as Agenda 2030 and others, geared to attaining climate neutrality by 2050. The ultimate goal is to transition from today’s linear economy and the use of natural resources to circular arrangements with the reuse of industrial waste as secondary raw materials.
After processing in management plants, CDW is divided into essentially two types of inorganic waste: concrete and mixed (concrete + masonry), whose deployment has been explored for primarily three applications. These include (a) coarse recycled aggregate for concrete [5,6,7], a use envisaged in many national standards, including Spain’s structural concrete code [8], for concrete waste in particular at replacement ratios of up to 20%; (b) recycled fines in mortars and concretes [9,10,11]; and (c) supplementary cementitious materials (SCMs) for the manufacture of future eco-cements with a smaller carbon footprint and lower Portland clinker content [12,13,14,15].
Under the third area, recent research has focused on recycled concrete fines (<5 mm), a material generated during concrete waste crushing and milling. That by-product is subsequently stockpiled in management plants, given its non-reusability due to the possible presence of very fine particles or even deleterious (sulfate, chloride) materials. Preliminary research conducted by the multidisciplinary team of authors of this article showed that these fine concrete fractions have low-to-medium pozzolanicity depending on factors such as the calcareous or siliceous nature of the original aggregate, the formation of C-S-H, C4AH13 and C4AcH12 gels [16] and the optimal physical and mechanical performance (or otherwise) of the 7% blended cement used [17,18,19]. Subsequent studies with binary blends prepared from the same concrete fines plus shatterproof glass (likewise recycled from CDW) at ratios of 2:1, 1:1 and 1:2 by weight revealed greater pozzolanicity (reactivity with lime in the medium) than exhibited by the same waste without glass [17]. Reaction kinetics, in turn, were found to depend on the nature of the concrete waste [20]. In all cases, the ternary cement pastes were observed to form more polymerized C-S-H gels than OPC with different morphologies and sodium in their structure due to the release of that ion by the glass (Na2O = 13%). Such microstructural changes would necessarily have a direct impact on the performance of these new ternary eco-cements.
The present study therefore proceeded to a first-ever analysis of the durability of ternary cement mortars made with 7% (2:1) concrete waste/glass blends based on their performance in terms of total water absorption, effective porosity, pressurized water penetration and carbonation and chloride resistance.

2. Materials and Methods

2.1. Raw Materials

The OPC used in this study, classified in Spanish legislation as CEM I 52.5R [21], was supplied by Cementos Lemona, S.A. (Bilbao, Spain).
Three construction and demolition wastes were analyzed: Two wastes from two fractions of fines (<5 mm) resulting from concrete waste crushing and milling were taken from two Spanish waste management plants that had stockpiled the material in open yards. Depending on the nature of the original aggregate, such fines were divided into calcareous (Hc) and siliceous (Hs). Finally, a shatterproof glass (G) with 100% amorphous material taken from a demolished residential building in northern Spain was selected. All three types of CDW were ground in the laboratory to a particle size of under 63 µm. X-ray diffraction (XRD) patterns and quantitative Rietveld analysis of the raw materials analyzed are included in Figure 1 and Table 1.

2.2. Ternary Cement Preparation

The ternary eco-cements were prepared by replacing 7% of the OPC with a 2:1 (by weight) binary blend of either Hc-G or Hs-G, found in preliminary research to be the optimal proportion [18,20]. The cements studied were labelled OPC (reference cement), 7% Hc-G (OPC additioned with 7% 2:1 Hc-G) and 7% Hs-G (OPC with 7% 2:1 Hs-G). XRF-determined chemical composition of the cements analyzed are included in Figure 2, whilst Table 2 gives their D10, D50 and D90 values.
The blended cement mortars were prepared with standardized siliceous sand (≥98% SiO2) at a binder/sand ratio of 1:3 and a water/binder ratio of 0.5 as specified in European standard EN 196-1 [22]. Prior to analyzing their physical properties, all the mortar specimens were soaked in water for up to 28 d. They were subsequently dried and tested further to the standards listed in the following subsection.

2.3. Methods

The durability tests were conducted to the recommendations set out in the existing standards for hardened concretes.
Water absorption, density and effective porosity, were found in keeping with Spanish standard UNE 83980 [23] on two samples drawn from the same specimen, core or test piece. Accordingly, the samples were oven dried to a constant weight and then immersed in water for 48 h. After determination of their weight, the specimens were boiled for 5 h. Subsequently, the specimens were allowed to cool to room temperature and were weighed in air and in water on a hydrostatic scale.
Pressurized water penetration was conducted as described in Spanish and European standard UNE EN 12390-8 [24] by hosing a 150 mm cubic specimen with water at a pressure of 500 kPa for 72 h. The specimens were split in two halves and the maximum and average depth of water penetration was then measured.
To find carbonation resistance as specified in international standard ISO 1920-12 [25], specimens were conditioned in a laboratory air environment for 14 days, and then exposed to accelerated carbonation with 3% CO2 for 72 d at 65% R.H. Carbonation depth, in turn, was determined by exposing two 100 mm cubic specimens to the phenolphthalein test.
Chloride ion resistance was established further to Spanish/European standard UE EN 12390-11 [26] on unidirectional diffusion. Accordingly, two 100 × 100 mm2 cylindrical specimens were water-saturated and provided with a pond containing 3% NaCl solution on one of their circular surfaces, sealed with a plastic film. The specimens were kept in these conditions for 90 days. After the exposure period, powder samples were extracted at different depths and their chloride content was subsequently analyzed by titration with silver nitrate according to the Volhard method (Method A), as described in the Spanish/European standard UNE EN 14629 [27].

2.4. Characterization Techniques

The compressive strength of the mortars was determined on an IBERTEST AUTOTEST 200/20-SW press on 28-day mortar specimens, following the EN 196-1 standard [22].
The chemical composition of the main oxides present was determined on pressed powder wafers using a Philips PW-1404 (Philips, Madrid, Spain) X-ray fluorescence spectrometer fitted with an Sc-Mo X-ray tube.
Mineralogical analysis and crystalline phase quantification were conducted on a Malvern Panalytical X’Pert Pro (Madrid, Spain) X-ray diffractometer bearing a copper anode and a 9.5 mm receiving slit, operating at 40 mA and 45 kV. The measuring range was 5–60°, with rutile as the internal standard. Rietveld quantification was calculated with Match (v.3) and Fullprof software (Bonn, Germany).
The dry dispersion D10, D50 and D90 values for the cements were found with a Malvern Panalytical Mastersizer 3000 laser diffraction particle size analyzer.
Cement mortar morphology, analyzed after the accelerated carbonation test, was determined under an FE Inspect W-SEM/EDX electron microscope fitted with a DX4i analyzer and a Si/Li detector (Hillsboro, OR, USA).

3. Results and Discussion

3.1. Water Absorption, Density, Effective Porosity and Mechanical Strength

Table 3 Total post-soaking absorption (TSA), post-soaking and boiling absorption (TSBA), dry (DD) and bulk (BD) density and effective porosity (EP) found as specified in Spanish standard UNE 83980 [23].
The dry and bulk density values for the ternary cement and reference mortars were very similar, although slightly higher in the 7% additioned materials, in all likelihood as a result of their greater fineness, which would induce minor matrix densification (Table 2).
Total post-soaking (TSA) and post-soaking and boiling (TSBA) water absorption values were lower in the mortars bearing 7% CDW-based binary blends than in the reference cement material. At 17%, the reduction in water absorption relative to the reference was greater in siliceous than in calcareous concrete waste, where the decline recorded was 9.2%.
Both blended cement mortars performed well in terms of post-soaking water absorption, with values much lower than the recommended ceiling (<10%) for high-quality cement matrices [28]. The explanation lies in the binary blend of pozzolans comprising low reactivity concrete waste (Hc: 1.18 × 10−4 K·h−4; Hs: 6.6 × 10−4 K·h−4) and high reactivity glass waste (G: 1.14 × 10−2 K·h−1). The resulting synergies were more intense in the siliceous (Hs) than in the calcareous concrete (Hc) blend. The pozzolanic reaction is widely known to induce additional hydrated phases in cement matrices, substantially modifying microporosity and the paste-aggregate interfacial transition zone (ITZ) [29,30]. The present findings were consistent with results reported in that connection by other authors working with blended cement mortars prepared with thermally activated coal tailings [31].
The standardized effective porosity (EP) test findings followed the same pattern as for TSA and TSBA, i.e., with the inclusion of the binary blend of pozzolans associated with declines in porosity of 5.2% in 7% Hc-G and 8.7% in 7% Hs-G relative to the reference mortar. As with total absorption, higher blended mortar performance in effective porosity was attendant upon the formation of secondary hydrated phases during the pozzolanic reaction. Vigil et al. [20] reported that the most prominent phase generated in pure Hs-G and Hc-G/lime systems, C-S-H gels, precipitated inside pores. The resulting reduction in microporosity and interconnectivity induced denser, less porous and less water-accessible mortar matrices.
In terms of mechanical properties, the 28-day compressive strength values shown in Table 3 reveal that the use of the binary CDW mixes at 7% substitution has a slightly negative effect. Nevertheless, only a minor impact on the mechanical performance is detected, reaching a loss of approximately 4% compared to the OPC mortar for both siliceous and calcareous mixes.

3.2. Water Penetration under Pressure

The penetration depths for the three mortars analyzed are summarized in Table 4. Greater depths were recorded for the mortars bearing 7% of either of the binary blends of pozzolans than for the reference mortar. The maximum value was 47.4% deeper in the former, irrespective of the nature of the original aggregate (Hc or Hs), with an absolute value of 28 mm in both types of blended mortar.
Further to the provisions of Spain’s Royal Decree on bulk and reinforced concrete (Spanish initials, DEE) [32], the mortars analyzed would be deemed impermeable to water under pressure, for the values observed lay below the allowable ceiling.

3.3. Accelerated Carbonation Resistance

Photographs of the mortar specimens after the accelerated carbonation test (72 d of exposure to 3% CO2) and spraying with phenolphthalein are reproduced in Figure 3.
Two clearly distinguishable areas were detected: the reddish-purple zone denoted pH values of over 10, an indication that the cement matrix was unaffected by the CO2, and a colorless rim denoting pH values of <8, signifying carbonation (primarily of portlandite) further to the following reaction:
CO2 + Ca(OH)2 → CaCO3 + H2O
However, other calcareous hydrates as well as anhydrous phases may have also been impacted by carbonation [33]. Portlandite carbonation is essentially a three-stage process: (a) portlandite dissolution; (b) absorption of CO2 and carbonate ion formation; and (c) chemical reaction and carbonate precipitation [34]. The SEM micrographs of the carbonated areas in the three mortars confirmed such carbonate precipitation in the form of aragonite and calcite (Figure 4).
The mean of the carbonation front depths measured on the two sides of each of the three specimens tested are given in Table 5, along with the respective standard deviations (SD).
After a 72-d exposure to 3% accelerated carbonation the mortars prepared with a binary blend of pozzolans exhibited lower carbonation resistance than the reference material, with 37.5% (7% Hc-G) and 15% (7% Hs-G) deeper carbonation fronts. The calcareous blend, in turn (Hc-G), was nearly 20% less resistant than the siliceous material (Hs-G). That may have primarily been the result of the higher effective porosity in the former (Table 3), which would have favored the uptake of the aggressive agent. It might also have been induced by the fact that the Hc waste was calcite-high (52%), which in turn would be associated with enhanced CO2 and calcium carbonate solubility due to the rise in the alkali content in the cement matrix prompted by the presence of glass [34].
Such poorer chemical resistance to carbonation in the blended cements would be associated with their lower portlandite content attributable to dilution (7% less clinker) and the pozzolanic reaction characteristic of CDW [16,35]. Both factors lead to a reduction of the alkaline reserve, which facilitates the lowering of the pH by reaction with CO2 and thus the progression of the carbonation front to deeper levels. In this study, a third factor may have had a further adverse impact on carbonation rate, attributable to the presence in the bended cements of recycled glass, known to have a high sodium content (recycled glass = 13% Na2O). Some authors have observed that alkalis favor carbonation [11], an adverse effect likewise reported for other pozzolanic additions (silica fume, fly ash, slag, activated paper, calcined clay, sludge, mixed CDW) [11,36,37,38,39].

3.4. Resistance to Chloride Ion Penetration

Figure 5 graphs the variation in chloride ion content with depth in the three mortars studied. The baseline chloride content, essentially sourced from the Portland cement, was very similar in all three (0.02 wt % to 0.03 wt %). Although the decline in chloride ion concentration observed is characteristic of ion transport in cement-based materials, the three mortars behaved differently. At the deeper depths analyzed, both 7% Hs-G and 7% Hc-G had lower chloride concentrations than OPC, an indication of higher resistance to ion transport. The difference was particularly visible in 7% Hs-G, where concentration in the deepest layer was 67% lower than observed in the OPC mortar, whereas the decline in concentration recorded in 7% Hc-G mortar was less significant in that layer. The chloride ion concentration in the reference was higher than in the 7% Hs-G mortars in all the layers analyzed, but not in the 7% Hc-G mortars, where it was lower in the outermost (first 8 mm) but higher in the deeper layers (>8 mm). The inference is that the mechanism leading to a lower chloride ion transport rate varied with the type of pozzolan.
The effect of the pozzolans on chloride ion transport was quantified by calculating the non-steady state diffusion coefficient (Dnss) for each mortar type. The experimental curves for chloride were subsequently fitted to Equation (2) in keeping with Fick’s law of diffusion as specified in Spanish/European standard UNE EN 12390-11 [26]:
C x = C i + ( C s + C i ) ( 1 erf [ x 2 D n s s t ] )
In Equation (2), Cx is chloride ion concentration at depth x at time t; Ci and Cs, respectively, are initial chloride content and the content on the exposed surface; and erf represents the error function. The fitted curves are plotted in Figure 6 and the parameters obtained are given in Table 6. The findings clearly revealed that the mortars with 7% replacement with a binary blend of CDW exhibited greater resistance to chloride penetration than the reference, with a 65% lower diffusion coefficient in 7% HS-G and 33% lower in 7% Hc-G. Such performance is consistent with the behavior observed in other pozzolanic additions [40,41,42,43,44,45,46], where the rate of chloride transport has customarily been associated with either enhanced chloride binding, lower matrix permeability, or both [47,48].
As noted in Section 3.1, the lower effective porosity in 7% Hs-G mortar was attributable to the greater pozzolan-induced intricacy of its pore system, an effect typically associated with a decline in the rate of ion diffusion in the material. Such lower permeability was consistent with the lower chloride ion concentration detected in mortar 7% Hs-G than in the OPC mortar at all the layers analyzed. Although mortar 7% Hc-G had lower porosity than the OPC material, the observation of higher chloride concentration values in the outermost layers (<8 mm) in the former than in the latter suggests that chemically- or physically-mediated chloride binding, rather than pore structure, played a determinant role in reducing the ion transport rate in this type of mortar. As in earlier studies, here mortars bearing calcareous CDW-based pozzolans were observed to form greater amounts of AFm-type phases, such as carboaluminates (Ca4Al2(CO3)·11H2O and Ca4Al2(CO3)0.5·12H2O) [20]. Such substances are known to react with chloride ions to form Friedel’s salt (Ca4Al2Cl2·10H2O), thereby immobilizing these ions in the outer layers and explaining the behavior of 7% Hc-G mortars in this regard [49,50,51]. In addition, chloride ions may also be physically adsorbed by C-S-H gels, a mechanism favored in the presence of gels with a higher Ca/Si ratio [45,52]. That is yet another indication of greater physical adsorption-governed ion binding capacity in 7% Hc-G mortars, as earlier research found their C-S-H gels to have a higher Ca/Si ratio [20].

4. Conclusions

The conclusions that can be drawn from the present study are set out below.
When added to OPC at a replacement ratio of 7%, binary CDW mortars bearing a 2:1 (by cement weight) blend of calcareous or siliceous concrete fines and shatterproof glass performed differently relative to the reference cement depending on whether the recycled concrete was calcareous (Hc) or siliceous (Hs).
The presence of CDW in the blended mortars lowered water absorption by 9.2% to 17%, depending on the nature of the recycled aggregate.
The same pattern was observed for effective porosity, which was 5.2% lower than the reference in 7% Hc-G and 8.7% lower in 7% Hs-G.
Although the maximum and mean penetration depths were greater in the blended cement mortars than in the reference mix, the former were Spanish structural code-compliant.
The accelerated carbonation test (with 3% CO2) showed that adding 7% of the binary blend of CDW led to slightly higher (1–3 mm) mean carbonation penetration than in the unadditioned reference.
Non-steady state resistance to chloride ion aggression was greater in the 7% blended mortars than in the OPC, although the Hs (siliceous-concrete bearing) samples performed better than their calcareous counterparts. The diffusion coefficients obtained by applying Fick’s law were 2.9 × 10−11 m2 s−1 for 7% Hs-G, 1.5 × 10−11 m2 s−1 for 7% Hc-G and 4.3 × 10−11 m2 s−1 for OPC.
The present findings support the premise that replacing OPC with a 2:1 binary blend of concrete fines (<5 mm) and shatterproof glass at a ratio of 7% does not compromise the durability of the resulting mortar. In fact, for most of the properties analyzed such mortars performed better than the reference material. These recycled products would consequently be usable to prepare future cement matrices with a lower clinker content and smaller carbon footprint. Such a promising future notwithstanding, further research would be recommended, primarily to test performance at higher replacement ratios than explored here.

Author Contributions

Conceptualization, all authors; methodology and testing, J.M.-J. and I.V.; SEM analysis, R.V.d.l.V.; chloride and CO2 analysis, L.C.-M.; design, preparation and final review, M.F. All authors have read and agreed to the published version of the manuscript.

Funding

This research was conducted as part of a national project funded by the Spanish Ministry of Science, Innovation and Universities (MICIU), the Spanish National Research Agency (AEI) and the European Regional Development Fund (ERDF), grant number RTI2018-097074-B-C21 and C-22.

Acknowledgments

The support received from the Spanish Construction and Demolition Waste Recycling Association (RCDA), Sika (Madrid, Spain) and the Spanish Institute of Cement and its Applications (IECA) is gratefully acknowledged.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Jesus, S.; Maia, C.; Brazao, C.; de Brito, J.; Veiga, R. Rendering mortars with incorporation of very fine aggregates from construction and demolition Waste. Contr. Build. Mater. 2019, 229, 116844. [Google Scholar] [CrossRef]
  2. Yilmaz, T.; Ercikdi, B.; Deveci, H. Utilization of CDW as cemented paste backfill materials for underground mine openings. J. Environ. Manag. 2018, 222, 250–259. [Google Scholar] [CrossRef] [PubMed]
  3. Ghisellini, P.; Ripa, M.; Ulgiati, S. Exploring environmental and economic costs and benefits of a circular economy approach to the CDW sector: A literature review. J. Clean. Prod. 2018, 178, 618–643. [Google Scholar] [CrossRef]
  4. Hamidreza, S.; Burman, M.; Braimah, N. Pathways to circular construction: An integrated management of CDW for resource recovery. J. Clean. Prod. 2020, 244, 118710. [Google Scholar]
  5. Díaz, M.; Plaza, P.; Blanco, D.; Jordán, M.M.; Sáez del Bosque, I.F.; Medina, C. The design and development of recycled concretes in a circular economy using mixed construction and demolition wastes. Materials 2021, 14, 4762. [Google Scholar] [CrossRef]
  6. Dimitriou, G.; Savva, P.; Petrou, M.F. Enhancing mechanical and durability properties of recycled aggregate concrete. Contr. Build. Mater. 2018, 158, 228–235. [Google Scholar] [CrossRef]
  7. Pacheco-Torgal, F.; Ding, Y.; Colangelo, F.; Tuladhar, R.; Koutamanis, A. Advances in Construction and Demolition Waste Recycled: Management, Processing and Environmental Assessment; Woodgeah Publising-Elsevier: Duxford, UK, 2020. [Google Scholar]
  8. Código Estructural Español. Real Decreto 470/2021; Ministerio de la Presidencia, Relaciones con las Cortes y Memoria Democrática: Madrid, España, 2021.
  9. Sun, C.; Chen, L.; Xiao, J.; Liu, Q.; Zuo, J. Low carbon and fundamental properties of eco-efficient mortar with recycled powders. Materials 2021, 14, 7503. [Google Scholar] [CrossRef]
  10. Moreno, J.; Vegas, I.J.; Gebremariam, A.T.; García-Cortés, V.; Di, F. Treatment of end of life concrete in an innovative heating air classification system for circular cement based products. J. Clean. Prod. 2020, 262, 121515. [Google Scholar] [CrossRef]
  11. Sáez del Bosque, I.F.; Van den Heede, P.; de Belie, N.; Sánchez de Rojas, M.I.; Medina, C. Carbonation of concrete wirth CDW based recycled aggregates and cement with recycled content. Constr. Build. Mater. 2020, 234, 117336. [Google Scholar] [CrossRef]
  12. Medina, C.; Banfill, P.F.G.; Sánchez de Rojas, M.I.; Frías, M. Rhelogical and calorimetric behavior of cements blended with containing ceramic sanitary ware and construction and demolition waste. Constr. Build. Mater. 2013, 40, 822–831. [Google Scholar] [CrossRef]
  13. Silva, Y.F.; Izquierdo, S.R.; Delvasto, S. Effect of masonry residue on the hydration of portland cement paste. Dyna 2019, 86, 367–377. [Google Scholar] [CrossRef] [Green Version]
  14. Ginga, C.P.; Maximino, J.; Klarissa, M. Circular economy on construction and demolition waste: A literature review on material recovery and production. Materials 2020, 13, 2970. [Google Scholar] [CrossRef] [PubMed]
  15. He, X.; Zheng, Z.; Yang, J.; Su, Y.; Wang, T. Feasibility of incorporating autoclaved aerated concrete waste for cement replacement in sustainable building materials. J. Clean. Prod. 2020, 250, 119455. [Google Scholar] [CrossRef]
  16. Frías, M.; Martínez, S.; Vigil, R.; Fernández, L.; García, R. reactivity in cement pastes bearing fine fraction concrete and glass from construction and demolition Waste: Microstructural analysis of viability. Cem. Concr. Res. 2021, 148, 106531. [Google Scholar] [CrossRef]
  17. Frías, M.; Vigil, R.; Martínez, S.; Fernández, L.; Villar, E.; García, R. Multi technique characterization of a fine fraction of CDW and assessment of reactivity in a CDW/lime system. Minerals 2020, 10, 590. [Google Scholar] [CrossRef]
  18. Moreno-Juez, J.; Vegas, I.; Frías, M.; Vigil, R.; Guede, E. Laboratory scale study and semi-industrial validation of viability of inorganic CDW fine fractions as SCMs in blended cements. Constr. Build. Mater. 2021, 271, 121823. [Google Scholar] [CrossRef]
  19. Caneda, L.; Monasterio, M.; Moreno, J.; Martínez, S.; García, R.; Frías, M. Behaviour and properties of ecocement pastes elaborated with recycled concrete powder from CDW. Materials 2021, 14, 1299. [Google Scholar] [CrossRef]
  20. Vigil, R.; Frías, M.; Martínez, S.; Fernández, S.; Villar, E.; García, R. Reactivity of binary construction and demolition waste mix as supplementary cementitious materials. Materials 2021, 14, 6481. [Google Scholar] [CrossRef]
  21. European Standard 197-1; Cement-Part 1: Composition, Specifications and Conformity Criteria for Common Cements. CEN-CENELEC: Brussels, Belgium, 2011.
  22. Spanish Standard UNE EN 196-1; Methods of Testing Cement. Part 1: Determination of Strengtcs. UNE: Madrid, Spain, 2018.
  23. Spanish Standard UNE 83980; Durabilidad del hormigón. Métodos de Ensayo. Determinación de la Absorción de Agua, Densidad y Porosidad Accesible al Agua del Hormigón. UNE: Madrid, Spain, 2014.
  24. Spanish Standard UNE EN 83980-8; Testing Hardened Concrete. Part 8: Depth of Penetration of Water under Pressure. UNE: Madrid, Spain, 2020.
  25. International Standard ISO 1920-12; Determination of the Carbonation Resistence of Concrete-Accelerated Carbonation Method. ISO: Geneve, Switzerland, 2015.
  26. Spanish Standard UNE EN 12390-11; Testing Hardened Concrete, Part 11. Determination of the Chloride Resistance of Concrete, Unidirectional Diffusion. AENOR: Madrid, Spain, 2019.
  27. Spanish Standard UNE EN 14629; Products and Systems for the Protection and Repair of Concrete Structures. Test Methods. Determination of Chloride Content in Hardened Concrete. AENOR: Madrid, Spain, 2007.
  28. Gupta, S.; Kua, H.W. Effect of wáter entrainment by pre-soaked biochar particles on strength and permeability of cement mortar. Constr. Build. Mater. 2018, 159, 107–125. [Google Scholar] [CrossRef]
  29. Taylor, H.F.W. Cement Chemistry, 2nd ed.; Thomas Telford Publishing: London, UK, 1997. [Google Scholar]
  30. Maso, J.C. Interfacial Transition Zone in Concrete, 1st ed.; Rilem Report 11; E& FN SPON: Suffolk, UK, 1996. [Google Scholar]
  31. Caneda, L.; Medina, C.; Sánchez de Rojas, M.I.; Frías, M. Water transport in binary eco-cements containing coal mining Waste. Cem. Concr. Comp. 2019, 104, 103373. [Google Scholar] [CrossRef]
  32. Real Decreto 470/2021 Sobre el Código Estructural; Ministerios de Transportes, Movilidad y Agenda Urbana y, de Industria, Comercio y Turismo: Madrid, España, 2021.
  33. Zajac, M.; Skibsted, J.; Durdzinski, P.; Bewn, M. Effect of alkalis on products of enforced carbonation of cement paste. Contr. Build. Mater. 2021, 291, 123203. [Google Scholar] [CrossRef]
  34. Savija, B.; Lukovic, M. Carbonation of cement paste: Understanding, challenges, and opportunities. Constr. Build. Mater. 2016, 117, 285–301. [Google Scholar] [CrossRef] [Green Version]
  35. Dow, C.; Glasser, F.P. Calcium carbonate efflorescence on Portland cement and building materials. Cem. Concr. Res. 2003, 33, 147–154. [Google Scholar] [CrossRef]
  36. Kobayashi, K.; Uno, Y. Influence of alkali on carbonation of concrete: Part 2. Cem. Conr. Res. 1990, 20, 619–624. [Google Scholar] [CrossRef]
  37. Frías, M.; Goñi, S. Accelerated carbonation effect on behaviour of ternary Portland cements. Compos. Part B 2013, 48, 122–128. [Google Scholar] [CrossRef]
  38. Shah, V.; Bishnoi, S. Carbonation resistance of cements containing supplementary cementitious materials and its relation to various parameters of concrete. Contr. Build. Mater. 2018, 178, 219–232. [Google Scholar] [CrossRef]
  39. Zhang, Y.; Sun, Q.; Yang, X. Changes in color and thermal properties of fly ash cement mortar after heat treatment. Construc. Build. Mater. 2018, 165, 72–81. [Google Scholar] [CrossRef]
  40. Liu, W.; Teng, L.; Rohani, S.; Qin, Z.; Zhao, B.; Xu, C.C.; Ren, S.; Liu, Q.; Liang, B. CO2 mineral carbonation using industrial solid wastes: A review of recent developments. Chem. Eng. J. 2021, 416, 129093. [Google Scholar] [CrossRef]
  41. Shi, Z.; Geiker, M.R.; Lothenbach, B.; De Weerdt, K.; Garzón, S.F.; Enemark-Rasmussen, K.; Skibsted, J. Friedel’s salt profiles from thermogravimetric analysis and thermodynamic modelling of Portland cement-based mortars exposed to sodium chloride solution. Cem. Concr. Compos. 2017, 78, 73–83. [Google Scholar] [CrossRef]
  42. Gruber, K.A.; Ramlochan, T.; Boddy, A.; Hooton, R.D.; Thomas, M.D.A. Increasing concrete durability with high-reactivity metakaolin. Cem. Concr. Compos. 2001, 23, 479–484. [Google Scholar] [CrossRef]
  43. Poon, C.S.; Kou, S.C.; Lam, L. Compressive strength, chloride diffusivity and pore structure of high performance metakaolin and silica fume concrete. Constr. Build. Mater. 2006, 20, 858–865. [Google Scholar] [CrossRef]
  44. Dhir, R.K.; Jones, M.R. Development of chloride-resisting concrete using fly ash. Fuel 1999, 78, 137–142. [Google Scholar] [CrossRef]
  45. Chindaprasirt, P.; Rukzon, S.; Sirivivatnanon, V. Resistance to chloride penetration of blended Portland cement mortar containing palm oil fuel ash, rice husk ash and fly ash. Constr. Build. Mater. 2008, 22, 932–938. [Google Scholar] [CrossRef]
  46. Zhu, Z.; Chu, H.; Guo, M.Z.; Shen, M.; Jiang, L.; Yu, L. Effect of silica fume and fly ash on the stability of bound chlorides in cement mortar during electrochemical chloride extraction. Constr. Build. Mater. 2020, 256, 119481. [Google Scholar] [CrossRef]
  47. Caneda-Martínez, L.; Frías, M.; Medina, C.; de Rojas, M.I.S.; Rebolledo, N.; Sánchez, J. Evaluation of chloride transport in blended cement mortars containing coal mining waste. Constr. Build. Mater. 2018, 190, 200–210. [Google Scholar] [CrossRef]
  48. Thomas, M.D.A.D.A.; Hooton, R.D.D.; Scott, A.; Zibara, H. The effect of supplementary cementitious materials on chloride binding in hardened cement paste. Cem. Concr. Res. 2012, 42, 1–7. [Google Scholar] [CrossRef]
  49. Shi, C.; Hu, X.; Wang, X.; Wu, Z.; Schutter, G. de Effects of Chloride Ion Binding on Microstructure of Cement Pastes. J. Mater. Civ. Eng. 2017, 29, 04016183. [Google Scholar] [CrossRef]
  50. Balonis, M.; Lothenbach, B.; Le Saout, G.; Glasser, F.P. Impact of chloride on the mineralogy of hydrated Portland cement systems. Cem. Concr. Res. 2010, 40, 1009–1022. [Google Scholar] [CrossRef]
  51. Yoon, S.; Ha, J.; Rosie, S.; Kilcoyne, D.A.; Jun, Y.; Eun, J.; Monteiro, P.J.M. Phase changes of monosulfoaluminate in NaCl aqueous solution. Materials 2016, 9, 401. [Google Scholar] [CrossRef] [Green Version]
  52. Zibara, H.; Hooton, R.D.; Thomas, M.D.A.; Stanish, K. Influence of the C/S and C/A ratios of hydration products on the chloride ion binding capacity of lime-SF and lime-MK mixtures. Cem. Concr. Res. 2008, 38, 422–426. [Google Scholar] [CrossRef]
Figure 1. XRD patterns of the materials analyzed.
Figure 1. XRD patterns of the materials analyzed.
Materials 15 02921 g001
Figure 2. XRF-determined chemical composition of the samples analyzed.
Figure 2. XRF-determined chemical composition of the samples analyzed.
Materials 15 02921 g002
Figure 3. Carbonation front after 72 d exposure to 3% CO2.
Figure 3. Carbonation front after 72 d exposure to 3% CO2.
Materials 15 02921 g003
Figure 4. Carbonate morphology: (a) aragonite; (b) calcite.
Figure 4. Carbonate morphology: (a) aragonite; (b) calcite.
Materials 15 02921 g004
Figure 5. Variation in chloride ion concentration with depth.
Figure 5. Variation in chloride ion concentration with depth.
Materials 15 02921 g005
Figure 6. Chloride ion concentration with depth (experimental data fitted to Equation (2)).
Figure 6. Chloride ion concentration with depth (experimental data fitted to Equation (2)).
Materials 15 02921 g006
Table 1. Mineralogical composition of the materials quantified by the Rietveld method.
Table 1. Mineralogical composition of the materials quantified by the Rietveld method.
Phase (%)OPCHcHsG
Alite (C3S)52---
Belite (C2S)20---
C3A9---
C4AF6---
Calcite45224-
Mica-104-
Feldspars-118-
Quartz-1048-
Am. matter91716100
Total100100100100
Table 2. Laser-determined D10, D50 and D90 values for the samples studied.
Table 2. Laser-determined D10, D50 and D90 values for the samples studied.
µmOPC7% Hc-G7% Hs-GHc-GHs-GG
D101.991.941.951.411.652.70
D5011.6010.9011.306.829.9912.40
D9034.2033.9034.6034.6041.6041.40
Table 3. Physical and mechanical parameters of the mortars under study.
Table 3. Physical and mechanical parameters of the mortars under study.
MortarTSA
(%)
TSBA
(%)
BD
(g/cm3)
DD
(g/cm3)
EP
(%)
Compressive Strength (MPa)
OPC7.68.32.072.4817.269.5
7%Hc-G6.97.82.082.4916.366.6
7%Hs-G6.37.42.102.5015.766.5
Table 4. Depth of water penetration under pressure (mm).
Table 4. Depth of water penetration under pressure (mm).
MortarMaximum Depth (mm)Mean Depth
(mm)
OPC1915
7% Hc-G2818
7% Hs-G2825
DEE specification≤50≤30
Table 5. Mean carbonation depth and standard deviation (SD).
Table 5. Mean carbonation depth and standard deviation (SD).
MortarMean Depth (mm)SD
OPC8.01.5
7% Hc-G11.01.3
7% Hs-G9.22.1
Table 6. Chloride diffusion coefficients.
Table 6. Chloride diffusion coefficients.
OPC7% Hc-G7% Hs-G
Dnss (m2/s)4.33 × 10−112.89 × 10−111.51 × 10−11
Error2.26 × 10−122.30 × 10−122.29 × 10−12
Cs (%)0.580.620.61
R20.9950.9880.967
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Moreno-Juez, J.; Caneda-Martínez, L.; Vigil de la Villa, R.; Vegas, I.; Frías, M. Durability of Construction and Demolition Waste-Bearing Ternary Eco-Cements. Materials 2022, 15, 2921. https://doi.org/10.3390/ma15082921

AMA Style

Moreno-Juez J, Caneda-Martínez L, Vigil de la Villa R, Vegas I, Frías M. Durability of Construction and Demolition Waste-Bearing Ternary Eco-Cements. Materials. 2022; 15(8):2921. https://doi.org/10.3390/ma15082921

Chicago/Turabian Style

Moreno-Juez, Jaime, Laura Caneda-Martínez, Raquel Vigil de la Villa, Iñigo Vegas, and Moisés Frías. 2022. "Durability of Construction and Demolition Waste-Bearing Ternary Eco-Cements" Materials 15, no. 8: 2921. https://doi.org/10.3390/ma15082921

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop