Article

Effect of Different Cleaning Methods on Shear Bond Strength of Resin Cement to Contaminated Zirconia

by
Maher Saeed Hajjaj
* and
Saeed Jamaan Alzahrani
Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia
*
Author to whom correspondence should be addressed.
Materials 2022, 15(14), 5068; https://doi.org/10.3390/ma15145068
Submission received: 4 June 2022 / Revised: 8 July 2022 / Accepted: 12 July 2022 / Published: 21 July 2022

Abstract

:
The aim of this study was to evaluate the effect of different cleaning methods on the shear bond strength (SBS) of resin cement to contaminated zirconia specimens. Eighty rectangular-shaped specimens (2 × 5 × 10 mm) were fabricated from Zirconia blocks (IPS e.max ZirCAD) and randomly divided into 8 groups (n = 10). Group A (control) was not exposed to contaminants. The following tests specimens were contaminated with saliva and silicone indicating paste. Group B was coated with ceramic primer, then subjected to contamination. Groups C, D, E, F, G, and H were contaminated; cleaned with water rinse, Ivoclean, air particle abrasion, hydrofluoric acid, KATANATM Cleaner and ZirCleanTM, respectively, and then coated with ceramic primer and bonded to dual cure resin cement cylinders. All the specimens were subjected to artificial aging and surviving specimens were subjected to the SBS test. For statistical analysis, ANOVA and multiple comparison methods at the 0.05 significance level were used. There was no statistically significant difference among Ivoclean (21.48 ± 2.90 MPa), air particle abrasion (21.92 ± 2.85 MPa), and the control group (24.68 ± 5.46). The application of ceramic primer before contamination did not preserve the SBS of resin cement to zirconia. Cleaning the contaminated zirconia surface with hydrofluoric acid (15.03 ± 3.63) or KATANATM Cleaner (17.27 ± 7.63) did not restore SBS to the uncontaminated state, but it was significantly higher than simply rinsing with water (12.46 ± 5.17) or the use of ZirCleanTM (11.59 ± 5.53). The bond strength of resin cement to zirconia was influenced by cleaning methods.

1. Introduction

There has been a significant increase in the use of zirconia-based restorations due to their high mechanical properties, excellent biocompatibility, ease of fabrication, and acceptable esthetics [1,2]. The longevity of the zirconia restoration is influenced by the durability of the bond strength between the luting cement to the zirconia surface, as well as to the tooth structure. Unlike glass ceramic material, etching zirconia to create micromechanical retention is not achievable with hydrofluoric acid due to the lack of glass phase [3,4,5]. Bonding zirconia to the tooth surface with resin cement involves two interfaces. The strong adhesive interface is between enamel/dentin and resin cement, and the weaker adhesive interface is between zirconia and resin cement [5,6].
In addition, exposure to contaminants (blood, saliva, or silicone indicating paste) during the clinical try-in of indirect restorations is inevitable. Contamination negatively affects the quality of the bond strength between the resin cement and the zirconia surface [7,8,9]. Rinsing with water is insufficient to decontaminate the bonding surface due to the adherence of organic material of saliva after contamination [10,11]. Thus, adequate cleaning of the contaminated zirconia surface is necessary for the longevity of the treatment, particularly for restorations with deficient retention and resistance forms.
Cleaning the contaminated surface with simple water rinse showed ineffective results in restoring the bond strength [12]. Several methods for cleaning contaminated zirconia before bonding have been reported in the literature [13,14,15,16,17,18,19,20]. Mechanical cleaning via sandblasting with alumina particles (Al2O3) is used to clean contaminated surfaces and increase surface energy, which effectively restores the original bond strength [13,14,15]. When sandblasting zirconia, it is recommended to follow adequate parameters for particle size, distance, and pressure to avoid large surface flaws [16].
Chemical cleaning methods for contaminated zirconia have also been reported. They are safely applied without an adverse effect on the mechanical properties of zirconia. Phosphoric acid has been effective in removing organic contaminants, but X-ray photoelectron spectroscopy proves that the presence of phosphorous residue which might influence the bonding negatively [17]. Hydrofluoric acid is readily available in the clinic and has been used to clean contaminated zirconia surfaces; it is believed that no residue of hydrofluoric acid remains when using this method in comparison to phosphoric acid [18]. Several commercially available products are advocated, for example, chemical cleaners for dental zirconia, such as Ivoclean (Ivoclar Vivadent, Schaan, Liechtenstein), ZirCleanTM (BISCO, Inc., Schaumburg, IL, USA), or [11] KATANATM Cleaner (Kurary Noritake Dental Inc., Okayama, Japan). Ivoclean is a highly alkaline (pH = 13) solution applied extraorally on zirconia surfaces for cleaning before cementation. This is a ceramic cleaner that has been shown to effectively clean contaminated surfaces [19,20]. This material contains zirconium oxide; when it is applied to a contaminated zirconia surface, it attracts contaminants, which is followed by water rinsing and air-drying to leave a clean surface [13,21]. ZirCleanTM is also an alkaline cleaning gel composed of potassium hydroxide, which breaks the ionic bond formed between the zirconia surface and the organic material from saliva [13]. KATANATM Cleaner is a mild acidic (pH = 4.5) cleaner containing 10-methacryloyloxdecal dihydrogen phosphate (10-MDP) salt and can be used for intraoral or extraoral applications. 10-MDP has a hydrophobic group that bonds to contaminants and a hydrophilic group that makes it easily removed by water rinse [13]. Another promising technique is Non-Thermal Atmospheric Plasma (NTAP) [22]. Despite this method of cleaning being difficult to be applied clinically, it has shown effective results in elimination of saliva [23].
Before bonding, it is recommended to apply a chemical promotor as a ceramic primer that contains 10-MDP on the zirconia surface to enhance the bonding to resin cements [24]. 10-MDP is an organophosphate monomer with two functional groups—a phosphate group that reacts with zirconia and a methacrylate group that copolymerizes with the resin cement [14]. Hence, the idea of 10-MDP ceramic primer application before exposure to contaminants was suggested as a preventive measure to preserve bond strength [20]. Thermocycling is a simulated ageing procedure that is used to stress the adhesive bond by exposing the specimens to different water tanks with different temperatures [17].
Recently introduced cleaning materials, such as KATANATM Cleaner and ZirCleanTM, have been tested in dry conditions [13,25], and it is recommended to investigate these materials after artificial ageing with thermocycling [13,26]. Considering the difficulty of zirconia etching and the negative influence of contaminants on the zirconia surface after clinical try-in steps, this in vitro study aimed to evaluate the shear bond strength of resin cement to contaminated zirconia specimens after using recently introduced surface cleaning solutions (Ivoclean, KATANATM Cleaner and ZirCleanTM) with conventional techniques (water rinse, air particle abrasion, or hydrofluoric acid). In addition, to test the impact of applying 10-MDP ceramic primer prior to contamination, as recommended by Angkasith et al. [20] The first null hypothesis is that there is no significant difference in the shear bond strength of resin cement and contaminated zirconia after using different cleaning methods. The second null hypothesis is that the application of ceramic primer prior to contamination will preserve the bond strength of resin cement to zirconia.

2. Materials and Methods

Pre-sintered zirconia blocks (IPS e.max ZirCAD, Ivoclar Vivadent, Schaan, Liechtenstein) were sectioned into eighty 2 × 5 × 10 mm specimens using a low-speed diamond saw (Allied techcut 4Low Speed Diamond Saw, Rancho Dominguez, CA USA) under water coolant. All specimens were polished with multiple silicon carbide papers (320, 400, 600, and 1200 grits) at 300 rpm for 20 s each. Then, specimens were sintered in a Vita ZYrcomat T furnace (Vita Zahnfabrik, Bad Sackingen, Germany) according to the manufacturer’s instructions. Specimens were embedded in chemically polymerized acrylic resin (poliREPAR S, Polident) for handling purposes during the shear bond strength test. The bonding surfaces of the specimens were inspected for any acrylic flashes and polished using 1200 grit carbide paper to remove all residues. Specimens were subjected to air particle abrasion with 50 µm Aluminum oxide (Al2O3) powder at 2.0 bar and at a 10 mm distance for 20 s. (Duostar Sandblaster, Bego, Bremen, Germany). Later, they were ultrasonically cleaned in distilled water for 5 min, then dried with a stream of air.
After that, specimens were randomly divided into 8 groups (n = 10) according to the cleaning methods. In the control group (group A), 10-MDP ceramic primer (Monobond N, Ivoclar Vivadent, Schaan, Liechtenstein) was applied using a micro-brush with agitation for 10 s and left for 60 s and then excess primer was dispersed using a dry-air stream for 5 s. For contamination, saliva was collected from a healthy male individual who refrained from eating, drinking, and brushing for 2 h before the collection process (Ethical approval from Research Ethics Committee, Faculty of Dentistry, King Abdulaziz University #175-12-20). In group B, specimens were coated with 10-MDP ceramic primer before exposure to contaminants, followed by contamination with human saliva, which was applied to zirconia surface and spread with a micro-brush for 2 min before rinsing with water and drying. Then, inorganic contamination was carried out by applying a layer of silicone indicating paste (Fit Checker Advanced Blue cartridge pack, GC America, Alsip, IL, USA) under 1 kg load and it was removed from the surface once it set (3 min). In groups C, D, E, F, G, and H, zirconia specimens were contaminated with saliva and silicone indicating paste, as mentioned above. Cleaning protocols were performed as described in the following. In Group C, specimens were only rinsed with water for 15 s and dried. In Group D, Ivoclean was applied using a micro-brush and left to react for 20 s and then rinsed with water thoroughly and dried. In Group E, specimens were subjected to additional air particle abrasion with 50 µm Aluminum oxide (Al2O3) powder at 2.0 bar and at a 10 mm distance for 20 s, then rinsed with water and dried. In Group F, specimens were treated with 9.6% hydrofluoric acid for 30 s and then rinsed with water and dried. In Group G, KATANATM Cleaner was applied to the specimens and rubbed using a micro-brush for 10 s, then rinsed with water and dried. In group H, a thin layer of ZirCleanTM was applied using a delivery tip, left for 20 s, and then rinsed with water and dried. A split Teflon mold was placed on the zirconia surface to produce a cylinder with the following dimensions: 4.25 mm diameter and 4 mm height. All specimens were dried with a dry-air stream then coated with 10-MDP ceramic primer as described earlier (Monobond N, Ivoclar Vivadent, Schaan, Liechtenstein). Self-adhesive resin cement (RelyXTM U200 automix, 3M ESPE, Seefeld, Germany) was injected into the mold and light cured for 40 s using an E-Morlit curing light (Apoza, NewTaipei, Taiwan) delivering a power of 1200 mW/cm2. The mold was disassembled carefully after light curing and any cement flashes were carefully removed using a sharp scalpel. Then, specimens were subjected to 5000 thermal cycles of artificial ageing at a temperature between 5 and 55 °C, which represents a 6-month intraoral simulation (Thermocycler THE-1100, Mechatronik, Pleidelsheim, Germany). Each cycle took about 1 min to complete. Table 1 summarizes the types and compositions of materials used in this study, Figure 1 demonstrates the flowchart of the test groups and cleaning methods and Figure 2 demonstrates steps of specimen preparation.
Shear bond strength (SBS) was measured using the universal testing machine (INSTRON, Norwood, MA, USA). The load was applied to the interface of the zirconia-resin cement at a crosshead speed of 1 mm/min until failure (Figure 3).
All the data were subjected to statistical analysis. Statistical analysis was performed using Statistical Package for the Social Sciences SPSS (version 20), while Microsoft Office Excel 2010 was used for data handling and graphical presentation. One-way analysis of variance (ANOVA) was used to compare the mean shear bond strength of different groups. The post hoc tests used Bonferroni method for comparison between tests groups. To compare each group with the control group, Dunnett’s test was used. The result was considered significant at a p-value of < 0.05. Two-tailed tests were assumed throughout the analysis for all statistical tests.

3. Results

Out of 80 specimens, 64 survived thermocycling. Three groups did not have any specimens that failed after thermocycling: control (A), Ivoclean (D), and air abrasion (E) groups. On the other hand, all the B group specimens, which were treated by applying primer only before contamination, failed during thermocycling.
The mean shear bond strength values in MPa and standard deviation were as follows: the control group A (24.68 ± 5.46), water rinsing group C (12.46 ± 5.17), Ivoclean group D (21.53 ± 2.74), air particle abrasion group E (21.92 ± 2.85), hydrofluoric acid group F (15.03 ± 3.63), KATANATM Cleaner group G (17.27 ± 7.63), and ZirCleanTM group H (11.59 ± 5.53). Table 2 and Figure 4 summarize the descriptive statistics for all groups.
The Shapiro–Wilk test was used to test the normality hypothesis of all the quantitative variables for a further choice of appropriate parametric and non-parametric tests. All the variables were found to be normally distributed, allowing the use of parametric tests. Levene’s test of homogeneity of variance was also applied. A one-way ANOVA showed highly statistically significant differences between the groups (p < 0.001), as presented in Table 3.
The first null hypothesis that there is no significant difference in the shear bond strength of resin cement to contaminated zirconia after using different cleaning methods was rejected. The application of 10-MDP ceramic primer before contamination (group B) did not preserve the SBS and all the specimens failed during thermocycling, so the second null hypothesis was also rejected.
Multiple comparisons between test groups were performed with the Bonferroni post hoc test. The result showed that the mean SBS of Ivoclean and air particle abrasion groups were significantly higher than water rinsing and ZirCleanTM groups, but they were statistically similar to hydrofluoric acid and KATANATM Cleaner groups. ZircleanTM group was the weakest among all groups and it was statistically similar to water rinsing. To compare each test group with the control group, Dunnett’s test showed that the SBS of control group was statistically similar to that of the Ivoclean and air particle abrasion groups, but significantly higher than that of the rest of the groups (water rinsing, hydrofluoric acid, KATANATM Cleaner, and ZirCleanTM groups).

4. Discussion

The durability of the bonding of zirconia restorations is important for long-term success [27]. In the present in vitro study, we evaluated the shear bond strength of resin cement to saliva and silicone indicating paste contaminated zirconia specimens after decontamination with water rinsing, Ivoclean, air particle abrasion, hydrofluoric acid, KATANATM Cleaner, and ZirCleanTM. Exposure to contaminants significantly influence the bond strength (p < 0.05). Only Ivoclean and air particle abrasion were able to restore the shear bond strength of resin cement to zirconia to the uncontaminated (control) state. The first null hypothesis that there is no significant difference in the shear bond strength of resin cement to contaminated zirconia after using different cleaning methods was rejected (p < 0.001). We also tested the hypothesis that the application of 10-MDP ceramic primer prior to contamination will preserve the bond strength, this hypothesis was also rejected, as none of the specimens survived after artificial ageing.
The application of ceramic primer containing 10-MDP on the cleaned zirconia surface is recommended for increasing bond strength [7]. The phosphate ester group of the 10-MDP reacts with the zirconia surface to create a bond that is more resistant to biodegradation and increases the durability of the bonding [22,26]. The mechanism of chemical interaction of 10-MDP and zirconia were investigated by Nagaoka et al. [28]. In addition to an ionic bond, they found that there is a hydrogen bond that is formed between 10-MDP and zirconia.
Angkasith et al. [20] recommended the application of 10-MDP ceramic primer to the try-in step to maintain the bond strength without using any cleaning agent. In the current study, this seemed to be an ineffective method, because none of the specimens survived after 5000 thermal cycles. This indicates that water rinsing after contamination with saliva and silicone indicating paste was not enough to clean the contaminated zirconia surface. However, applying 10-MDP ceramic primer after contamination alone did restore half of the bond strength (12.46 MPa) of the control group (24.67 MPa). The highest shear bond strength in the test groups was found in the air particle abrasion (21.92 MPa) and Ivoclean (21.53 MPa) cleaning method group. Mechanical cleaning with air particle abrasion has proven to be a successful method for cleaning contaminated surfaces [7,9,13,17]. This method increases the surface area and surface energy to enhance the bonding to the zirconia surface. The influence of the application of air particle abrasion on mechanical properties to create a flaw in the surface has been investigated previously, with contradictory results [29,30,31,32]. Ivoclean is a chemical cleaning method and has been reported as an effective way to restore shear bond strength after contamination [9,13,19,20,21]. It has affinity to organic contaminants higher than the zirconia surface due to the high concentration of the zirconia particles in the solution. KATANATM Cleaner is an acidic material (pH = 4.5) containing 10-MDP salts that act as a surfactant to remove hydrophobic contaminants [10]. It was introduced to the market as a cleaner for either intraoral or extraoral application and either for tooth or restorative materials [33]. ZirCleanTM is a ceramic cleaner solution containing potassium hydroxide with high alkalinity (pH > 13), which neutralizes acids in organic contaminants and cleans them [11]. In the current study, KATANATM Cleaner was more effective in restoring the SBS (17.27 MPa), while ZirCleanTM showed the lowest performance amongst all groups (11.59 MPa). There are limited studies available in the literature about the effectiveness of KATANATM Cleaner or ZirCleanTM as cleaning methods [13,22,25,26]. A single study included both ZirCleanTM and KATANATM Cleaner and found no significant difference in SBS [13]. However, we found a significant difference between KATANATM Cleaner and ZirCleanTM. In our study, we used thermocycling to perform artificial ageing for 5000 cycles, which was not used in the aforementioned study, which might explains the different results [13]. Sahin et al. [26] found that after 1 week of ageing at 37 °C, there was no statistical difference in SBS between the Ivoclean and KATANATM Cleaner groups with two different resin cements. Awad et al. [22] and Tian et al. [11] found that Ivoclean and KATANATM cleaners are effective methods for the decontamination of a zirconia surface exposed to saliva and blood. In our study, we found a statistically significant difference between Ivoclean and KATANATM cleaners after thermocycling. Among the reasons for this difference is the use of different ceramic primers and resin cements in all the studies. In a meta-analysis [6], it was found that the type of cement used significantly influences the bond strength. Hydrofluoric acid is routinely used to etch glass ceramics to increase bond strength. However, due to the polycrystalline nature of zirconia, it is difficult to etch zirconia surfaces with 9.6% hydrofluoric acid. Hydrofluoric acid was applied to contaminated zirconia to dissolve organic contaminants from the surface, but the result was not satisfying (15.03 MPa) [13]. The simplest and most direct way of cleaning in the clinical setting is rinsing with water before applying 10-MDP. In the presented study, this method was proven to be ineffective in restoring bond strength. The same findings were reported by different authors, regardless of the contaminants used [11,13,22].
One of the limitations of our study was using a shear bond test instead of a microtensile bond test, which has more uniform stress distribution at the bonding interface. However, the shear bond test is commonly used for the assessment of ceramic bond strength and provides an acceptable ranking of the test groups. Another limitation is that specimens were not analyzed under a microscope to study the original, contaminated, and treated zirconia surfaces, or to categorize the failure mode.

5. Conclusions

From this in vitro study, the following conclusions were drawn. The contamination of zirconia restoration with saliva and silicone indicating paste significantly reduced the shear bond strength of resin cement to zirconia. Ivoclean and air particle abrasion were able to restore the SBS of resin cement to zirconia, similar to the uncontaminated control group. The application of ceramic primer to the zirconia surface before contamination did not preserve the SBS of resin cement to zirconia. Cleaning the contaminated zirconia surface with KATANATM Cleaner or hydrofluoric acid did not restore SBS to the uncontaminated state, but it was significantly higher than simply rinsing with water or the use of ZirCleanTM. Artificial ageing with thermocycling is important to stress the bond strength and validate the bond strength between zirconia and resin cement.

Author Contributions

Conceptualization, M.S.H.; methodology, M.S.H. and S.J.A.; software, M.S.H. and S.J.A.; validation, M.S.H. and S.J.A.; formal analysis, M.S.H. and S.J.A.; investigation, M.S.H. and S.J.A.; resources, M.S.H. and S.J.A.; data curation, M.S.H. and S.J.A.; writing—original draft preparation, S.J.A.; writing—review and editing, M.S.H.; visualization, M.S.H. and S.J.A.; supervision, M.S.H.; project administration, M.S.H.; funding acquisition, M.S.H. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki and approved by the Ethics Committee of Faculty of Dentistry, King Abdulaziz University (protocol code 175-12-20 and date of approval 18 January 2021).

Informed Consent Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Denry, I.; Kelly, J.R. State of the art of zirconia for dental applications. Dent. Mater. 2008, 24, 299–307. [Google Scholar] [CrossRef]
  2. Kontonasaki, E.; Rigos, A.E.; Ilia, C.; Istantsos, T. Monolithic Zirconia: An Update to Current Knowledge. Optical Properties, Wear, and Clinical Performance. Dent. J. 2019, 7, 90. [Google Scholar] [CrossRef] [Green Version]
  3. Kern, M.; Barloi, A.; Yang, B. Surface conditioning influences zirconia ceramic bonding. J. Dent. Res. 2009, 88, 817–822. [Google Scholar] [CrossRef]
  4. Kern, M.; Wegner, S.M. Bonding to zirconia ceramic: Adhesion methods and their durability. Dent. Mater. 1998, 14, 64–71. [Google Scholar] [CrossRef]
  5. Inokoshi, M.; De Munck, J.; Minakuchi, S.; Van Meerbeek, B. Meta-analysis of bonding effectiveness to zirconia ceramics. J. Dent. Res. 2014, 93, 329–334. [Google Scholar] [CrossRef]
  6. Özcan, M.; Bernasconi, M. Adhesion to zirconia used for dental restorations: A systematic review and meta-analysis. J. Adhes. Dent. 2015, 17, 7–26. [Google Scholar] [CrossRef]
  7. Blatz, M.B.; Alvarez, M.; Sawyer, K.; Brindis, M. How to Bond Zirconia: The APC Concept. Compend. Contin. Educ. Dent. 2016, 37, 611–617. [Google Scholar]
  8. Yang, B.; Scharnberg, M.; Wolfart, S.; Quaas, A.C.; Ludwig, K.; Adelung, R.; Kern, M. Influence of contamination on bonding to zirconia ceramic. J. Biomed. Mater. Res. B Appl. Biomater. 2007, 81, 283–290. [Google Scholar] [CrossRef]
  9. Noronha, M.D.S.; Fronza, B.M.; André, C.B.; de Castro, E.F.; Soto-Montero, J.; Price, R.B.; Giannini, M. Effect of zirconia decontamination protocols on bond strength and surface wettability. J. Esthet. Restor. Dent. 2020, 32, 521–529. [Google Scholar] [CrossRef]
  10. Yang, B.; Lange-Jansen, H.C.; Scharnberg, M.; Wolfart, S.; Ludwig, K.; Adelung, R.; Kern, M. Influence of saliva contamination on zirconia ceramic bonding. Dent. Mater. 2008, 24, 508–513. [Google Scholar] [CrossRef]
  11. Tian, F.; Londono, J.; Villalobos, V.; Pan, Y.; Ho, H.X.; Eshera, R.; Sidow, S.J.; Bergeron, B.E.; Wang, X.; Tay, F.R. Effectiveness of different cleaning measures on the bonding of resin cement to saliva-contaminated or blood-contaminated zirconia. J. Dent. 2022, 120, 104084. [Google Scholar] [CrossRef] [PubMed]
  12. Gulati, J.S.; Tabiat-Pour, S.; Watkins, S.; Banerjee, A. Resin-Bonded Bridges—the Problem or the Solution? Part 2: Practical Techniques. Dent. Update 2016, 43, 608. [Google Scholar] [CrossRef] [PubMed]
  13. Sulaiman, T.A.; Altak, A.; Abdulmajeed, A.; Rodgers, B.; Lawson, N. Cleaning Zirconia Surface Prior To Bonding: A Comparative Study of Different Methods and Solutions. J. Prosthodont. 2022, 31, 239–244. [Google Scholar] [CrossRef] [PubMed]
  14. Russo, D.S.; Cinelli, F.; Sarti, C.; Giachetti, L. Adhesion to Zirconia: A Systematic Review of Current Conditioning Methods and Bonding Materials. Dent. J. 2019, 7, 74. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  15. Quaas, A.C.; Yang, B.; Kern, M. Panavia F 2.0 bonding to contaminated zirconia ceramic after different cleaning procedures. Dent. Mater. 2007, 23, 506–512. [Google Scholar] [CrossRef]
  16. Ozcan, M. Air abrasion of zirconia resin-bonded fixed dental prostheses prior to adhesive cementation: Why and how? J. Adhes. Dent. 2013, 15, 394. [Google Scholar] [CrossRef]
  17. Phark, J.-H.; Duarte, S.; Kahn, H.; Blatz, M.B.; Sadan, A. Influence of contamination and cleaning on bond strength to modified zirconia. Dent. Mater. 2009, 25, 1541–1550. [Google Scholar] [CrossRef]
  18. Wattanasirmkit, K.; Charasseangpaisarn, T. Effect of different cleansing agents and adhesive resins on bond strength of contaminated zirconia. J. Prosthodont. Res. 2019, 63, 271–276. [Google Scholar] [CrossRef]
  19. Samran, A.; Al-Ammari, A.; El Bahra, S.; Halboub, E.; Wille, S.; Kern, M. Bond strength durability of self-adhesive resin cements to zirconia ceramic: An in vitro study. J. Prosthet. Dent. 2019, 121, 477–484. [Google Scholar] [CrossRef]
  20. Angkasith, P.; Burgess, J.O.; Bottino, M.C.; Lawson, N.C. Cleaning Methods for Zirconia Following Salivary Contamination. J. Prosthodont. 2016, 25, 375–379. [Google Scholar] [CrossRef]
  21. Kim, D.H.; Son, J.S.; Jeong, S.H.; Kim, Y.K.; Kim, K.H.; Kwon, T.Y. Efficacy of various cleaning solutions on saliva-contaminated zirconia for improved resin bonding. J. Adv. Prosthodont. 2015, 7, 85–92. [Google Scholar] [CrossRef] [PubMed]
  22. Awad, M.M.; Alhalabi, F.; Alzahrani, K.M.; Almutiri, M.; Alqanawi, F.; Albdiri, L.; Alshehri, A.; Alrahlah, A.; Ahmed, M.H. 10-Methacryloyloxydecyl Dihydrogen Phosphate (10-MDP)—Containing Cleaner Improves Bond Strength to Contaminated Monolithic Zirconia: An In-Vitro Study. Materials 2022, 15, 1023. [Google Scholar] [CrossRef] [PubMed]
  23. Piest, C.; Wille, S.; Strunskus, T.; Polonskyi, O.; Kern, M. Efficacy of Plasma Treatment for Decontaminating Zirconia. J. Adhes. Dent. 2018, 20, 289–297. [Google Scholar] [CrossRef]
  24. Yang, L.; Chen, B.; Xie, H.; Chen, Y.; Chen, Y.; Chen, C. Durability of Resin Bonding to Zirconia Using Products Containing 10-Methacryloyloxydecyl Dihydrogen Phosphate. J. Adhes. Dent. 2018, 20, 279–287. [Google Scholar] [CrossRef] [PubMed]
  25. Atoche-Socola, K.J.; Arriola-Guillén, L.E.; López-Flores, A.I.; Garcia, I.M.; Huertas-Mogollón, G.; Collares, F.M.; Branco Leitune, V.C. Microshear bond strength of dual-cure resin cement in zirconia after different cleaning techniques: An in vitro study. J. Adv. Prosthodont. 2021, 13, 237–245. [Google Scholar] [CrossRef] [PubMed]
  26. Sahin, S.C.; Celik, E. The effect of different cleaning agents and resin cement materials on the bond strength of contaminated zirconia. Microsc. Res. Tech. 2021, 85, 840–847. [Google Scholar] [CrossRef]
  27. Blatz, M.B.; Vonderheide, M.; Conejo, J. The Effect of Resin Bonding on Long-Term Success of High-Strength Ceramics. J. Dent. Res. 2018, 97, 132–139. [Google Scholar] [CrossRef] [PubMed]
  28. Nagaoka, N.; Yoshihara, K.; Feitosa, V.P.; Tamada, Y.; Irie, M.; Yoshida, Y.; Van Meerbeek, B.; Hayakawa, S. Chemical interaction mechanism of 10-MDP with zirconia. Sci. Rep. 2017, 7, 45563. [Google Scholar] [CrossRef] [Green Version]
  29. Güngör, M.B.; Yılmaz, H.; Nemli, S.K.; Bal, B.T.; Aydın, C. Effect of surface treatments on the biaxial flexural strength, phase transformation, and surface roughness of bilayered porcelain/zirconia dental ceramics. J. Prosthet. Dent. 2015, 113, 585–595. [Google Scholar] [CrossRef]
  30. Song, J.Y.; Park, S.W.; Lee, K.; Yun, K.D.; Lim, H.P. Fracture strength and microstructure of Y-TZP zirconia after different surface treatments. J. Prosthet. Dent. 2013, 110, 274–280. [Google Scholar] [CrossRef]
  31. Zhang, Y.; Lawn, B.R.; Malament, K.A.; Van Thompson, P.; Rekow, E.D. Damage accumulation and fatigue life of particle-abraded ceramics. Int. J. Prosthodont. 2006, 19, 442–448. [Google Scholar] [PubMed]
  32. Zhang, Y.; Lawn, B.R.; Rekow, E.D.; Thompson, V.P. Effect of sandblasting on the long-term performance of dental ceramics. J. Biomed. Mater. Res. B Appl. Biomater. 2004, 71, 381–386. [Google Scholar] [CrossRef] [PubMed]
  33. Tajiri-Yamada, Y.; Mine, A.; Nakatani, H.; Kawaguchi-Uemura, A.; Matsumoto, M.; Hagino, R.; Yumitate, M.; Ban, S.; Yamanaka, A.; Miura, J.; et al. MDP is effective for removing residual polycarboxylate temporary cement as an adhesion inhibitor. Dent. Mater. J. 2020, 39, 1087–1095. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Flowchart of the test groups and cleaning methods.
Figure 1. Flowchart of the test groups and cleaning methods.
Materials 15 05068 g001
Figure 2. Steps of specimens’ preparation: (A) Cutting of rectangular-shaped pre-sintered zirconia blocks (IPS e.max ZirCAD, Ivoclar Vivadent, Schaan, Liechtenstein); (B) Embedded zirconia in acrylic resin; (C) Materials used for surface cleaning and bonding; and (D) Resin cement cylinder bonded to zirconia surface.
Figure 2. Steps of specimens’ preparation: (A) Cutting of rectangular-shaped pre-sintered zirconia blocks (IPS e.max ZirCAD, Ivoclar Vivadent, Schaan, Liechtenstein); (B) Embedded zirconia in acrylic resin; (C) Materials used for surface cleaning and bonding; and (D) Resin cement cylinder bonded to zirconia surface.
Materials 15 05068 g002
Figure 3. Specimen mounted in universal testing machine for shear bond strength test.
Figure 3. Specimen mounted in universal testing machine for shear bond strength test.
Materials 15 05068 g003
Figure 4. Shear bond strength of self-adhesive resin cement to saliva and silicone indicating paste-contaminated zirconia that had been exposed to different cleaning methods. Data are mean ± standard deviations. Vertical bars labeled with the same letter indicate no significant difference (p > 0.05).
Figure 4. Shear bond strength of self-adhesive resin cement to saliva and silicone indicating paste-contaminated zirconia that had been exposed to different cleaning methods. Data are mean ± standard deviations. Vertical bars labeled with the same letter indicate no significant difference (p > 0.05).
Materials 15 05068 g004
Table 1. Summary of the products used in the study.
Table 1. Summary of the products used in the study.
MaterialsManufacturerComposition
IPS e.max ZirCADIvoclar-Vivadent AG, Schaan, LiechtensteinZrO2, Y2O3, HfO2, Al2O3, and other oxides
Monobond NIvoclar-Vivadent AG, Schaan, LiechtensteinAlcohol solution of silane methacrylate, phosphoric acid methacrylate, sulfide methacrylate
RelyX U200 Automix3M ESPE, Dental Products, Saint Paul, MN, USABase: Methacrylate monomers containing phosphoric acid groups, methacrylate monomers, silanated fillers, initiator components, stabilizer, rheological additives
Catalyst: methacrylate monomers, alkaline (basic) fillers, silanated fillers, initiator components, stabilizer, pigments, rheological additives
IvocleanIvoclar-Vivadent AG, Schaan, LiechtensteinPolyethyleneglycol, sodium hydroxide, ZrO2, water
KATANATM CleanerKuraray Noritake Dental Inc., Tokyo, JapanTriethanolamine, polyethyleneglycol, 10-Methacryloyloxydecyl dihydrogen phosphate salt
ZirCleanTMBisco Inc., Schaumburg, IL, USAPotassium hydroxide
Korox 50BEGO, Bremen, GermanyAl2O3 (50 μm)
Table 2. Descriptive statistics for shear bond strength test.
Table 2. Descriptive statistics for shear bond strength test.
GroupCleaning MethodNMean (MPa)95% Confidence Interval for Mean
Lower BoundUpper Bound
Group A (Control)no contamination, primer1024.68 ± 5.46 A20.7728.58
Group Bprimer, contamination, water0All specimens failed during thermocycling
Group Ccontamination, water, primer812.46 ± 5.17 C8.1416.78
Group Dcontamination, Ivoclean, primer1021.53 ± 2.74 A,B19.5723.49
Group Econtamination, air abrasion, primer1021.92 ± 2.85 A,B19.8923.96
Group Fcontamination, hydrofluoric acid, primer815.03 ± 3.63 B,C12.0018.06
Group Gcontamination, KATANATM Cleaner, primer917.27 ± 7.63 B,C11.4023.14
Group Hcontamination, ZirCleanTM, primer911.59 ± 5.53 C7.3415.84
Similar superscript letters indicate no statistically significant difference (p < 0.05).
Table 3. One-way ANOVA table.
Table 3. One-way ANOVA table.
SSdfMSFp Value
Between Groups1413.8016235.6349.602<0.001 *
Within Groups1398.7965724.540
Total2812.59863
ANOVA, analysis of variance; df, degree of freedom (n−1); MS, mean squares; SS, sum of squares. * Significant at p < 0.05.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Hajjaj, M.S.; Alzahrani, S.J. Effect of Different Cleaning Methods on Shear Bond Strength of Resin Cement to Contaminated Zirconia. Materials 2022, 15, 5068. https://doi.org/10.3390/ma15145068

AMA Style

Hajjaj MS, Alzahrani SJ. Effect of Different Cleaning Methods on Shear Bond Strength of Resin Cement to Contaminated Zirconia. Materials. 2022; 15(14):5068. https://doi.org/10.3390/ma15145068

Chicago/Turabian Style

Hajjaj, Maher Saeed, and Saeed Jamaan Alzahrani. 2022. "Effect of Different Cleaning Methods on Shear Bond Strength of Resin Cement to Contaminated Zirconia" Materials 15, no. 14: 5068. https://doi.org/10.3390/ma15145068

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop