Editorial

Special Issue “Novel Research about Biomechanics and Biomaterials Used in Hip, Knee and Related Joints”

by
Jan Philippe Kretzer
1,* and
Catherine Van Der Straeten
2
1
Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany
2
Health Innovation and Research Institute, Ghent University Hospital, C. Heymanslaan 10, 9000 Gent, Belgium
*
Author to whom correspondence should be addressed.
Materials 2021, 14(9), 2222; https://doi.org/10.3390/ma14092222
Submission received: 22 April 2021 / Accepted: 25 April 2021 / Published: 26 April 2021
Joint replacement is a very successful medical treatment. However, the survivorship of hip, knee, shoulder, and other implants is variable depending on the material and the loading conditions. The degradation of materials, but also the immune response against degradation products or an altered tissue loading condition as well as infections remain key factors of their failure.
Current research in biomechanics and biomaterials is trying to overcome the existing limitations. This includes new implant designs and materials, bearings concepts and tribology, kinematical concepts, surgical techniques, and anti-inflammatory and infection prevention strategies. A careful evaluation of new materials and concepts is required in order to fully assess the strengths and weaknesses and improve the quality and outcomes of joint replacements. Therefore, extensive research and clinical trials are essential.
The main aspects that are addressed in this Special Issue are related to new materials, the design and manufacturing considerations of implants [1,2,3,4,5,6,7,8,9,10], implant wear and its potential clinical consequences [11,12,13,14,15,16], implant fixation [17,18,19], infection-related material aspects [20,21] and taper-related research topics [22,23,24].
This Special Issue gives an overview of the ongoing research in these fields. Contributions are solicited from researchers working in the fields of biomechanics, biomaterials, and bio- and tissue-engineering.
We hope you enjoy reading this book.

Funding

This research received no external funding.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. de Ruiter, L.; Cowie, R.M.; Jennings, L.M.; Briscoe, A.; Janssen, D.; Verdonschot, N. The effects of cyclic loading and motion on the implant-cement interface and cement mantle of peek and cobalt-chromium femoral total knee arthroplasty implants: A preliminary study. Materials 2020, 13, 3323. [Google Scholar] [CrossRef] [PubMed]
  2. Bormann, T.; Mai, P.T.; Gibmeier, J.; Sonntag, R.; Muller, U.; Kretzer, J.P. Corrosion behavior of surface-treated metallic implant materials. Materials 2020, 13, 2011. [Google Scholar] [CrossRef]
  3. Kebbach, M.; Darowski, M.; Krueger, S.; Schilling, C.; Grupp, T.M.; Bader, R.; Geier, A. Musculoskeletal multibody simulation analysis on the impact of patellar component design and positioning on joint dynamics after unconstrained total knee arthroplasty. Materials 2020, 13, 2365. [Google Scholar] [CrossRef] [PubMed]
  4. Correa Filho, L.; Schmidt, S.; Goyenola, C.; Skjoldebrand, C.; Engqvist, H.; Hogberg, H.; Tobler, M.; Persson, C. The effect of n, c, cr, and nb content on silicon nitride coatings for joint applications. Materials 2020, 13, 1896. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  5. Wölfle-Roos, J.; Amet, B.K.; Fiedler, J.; Michels, H.; Kappelt, G.; Ignatius, A.; Dürselen, L.; Reichel, H.; Brenner, R. Optimizing manufacturing and osseointegration of ti6al4v implants through precision casting and calcium and phosphorus ion implantation? In vivo results of a large-scale animal trial. Materials 2020, 13, 1670. [Google Scholar]
  6. Vogel, D.; Klimek, M.; Saemann, M.; Bader, R. Influence of the acetabular cup material on the shell deformation and strain distribution in the adjacent bone-a finite element analysis. Materials 2020, 13, 1372. [Google Scholar] [CrossRef] [Green Version]
  7. Hettich, G.; Schierjott, R.A.; Epple, M.; Gbureck, U.; Heinemann, S.; Mozaffari-Jovein, H.; Grupp, T.M. Calcium phosphate bone graft substitutes with high mechanical load capacity and high degree of interconnecting porosity. Materials 2019, 12, 3471. [Google Scholar] [CrossRef] [Green Version]
  8. Adler, D.; Akbar, M.; Spicher, A.; Goerke, S.A.; Schmoelz, W. Biomechanical study of a novel, expandable, non-metallic and radiolucent cf/peek vertebral body replacement (vbr). Materials 2019, 12, 2732. [Google Scholar] [CrossRef] [Green Version]
  9. Almansour, H.; Sonntag, R.; Pepke, W.; Bruckner, T.; Kretzer, J.P.; Akbar, M. Impact of electrocautery on fatigue life of spinal fusion constructs-an in vitro biomechanical study. Materials 2019, 12, 2471. [Google Scholar] [CrossRef] [Green Version]
  10. Inyang, A.O.; Vaughan, C.L. Functional characteristics and mechanical performance of pcu composites for knee meniscus replacement. Materials 2020, 13, 1886. [Google Scholar] [CrossRef] [Green Version]
  11. Eckert, J.A.; Mueller, U.; Walker, T.; Schwarze, M.; Jaeger, S.; Kretzer, J.P. Bearing thickness is not a predictive factor for damage and penetration in oxford unicompartmental knee arthroplasty-a retrieval analysis. Materials 2020, 13, 4589. [Google Scholar] [CrossRef]
  12. Braun, S.; Jaeger, S.; Sonntag, R.; Schroeder, S.; Kretzer, J.P. Quantitative measurements of backside wear in acetabular hip joint replacement: Conventional polyethylene versus cross-linked polyethylene. Materials 2020, 13, 1854. [Google Scholar] [CrossRef] [Green Version]
  13. Bormann, T.; Jager, S.; Kretzer, J.P.; Nebel, L.; Clarius, L.; Omlor, G.; Bitsch, R.; Lehner, B. Retrieval analysis of modern knee tumor megaendoprosthesis shows considerable volumetric metal wear generated at the rotating hinge. Materials 2020, 13, 1519. [Google Scholar] [CrossRef] [Green Version]
  14. Cowie, R.M.; Pallem, N.M.; Briscoe, A.; Jennings, L.M. Third body wear of uhmwpe-on-peek-optima. Materials 2020, 13, 1264. [Google Scholar] [CrossRef] [Green Version]
  15. Cheng, X.; Dirmeier, S.C.; Hasselt, S.; Baur-Melnyk, A.; Kretzer, J.P.; Bader, R.; Utzschneider, S.; Paulus, A.C. Biological reactions to metal particles and ions in the synovial layer of mice. Materials 2020, 13, 1044. [Google Scholar] [CrossRef] [Green Version]
  16. Reiner, T.; Klotz, M.C.; Seelmann, K.; Hertzsch, F.; Innmann, M.M.; Streit, M.R.; Nees, T.A.; Moradi, B.; Merle, C.; Kretzer, J.P.; et al. Long-term results of a second-generation, small-diameter, metal-on-metal bearing in primary total hip arthroplasty at 14-year follow-up. Materials 2020, 13, 557. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  17. Beckmann, N.A.; Bitsch, R.G.; Schonhoff, M.; Siebenrock, K.A.; Schwarze, M.; Jaeger, S. Comparison of the primary stability of porous tantalum and titanium acetabular revision constructs. Materials 2020, 13, 1783. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  18. Jaeger, S.; Uhler, M.; Schroeder, S.; Beckmann, N.A.; Braun, S. Comparison of different locking mechanisms in total hip arthroplasty: Relative motion between cup and inlay. Materials 2020, 13, 1392. [Google Scholar] [CrossRef] [Green Version]
  19. Beckmann, N.A.; Bitsch, R.G.; Bormann, T.; Braun, S.; Jaeger, S. Titanium acetabular component deformation under cyclic loading. Materials 2019, 13, 52. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  20. Lunz, A.; Sonntag, R.; Kretzer, J.P.; Jaeger, S.; Bormann, T.; Streit, M.R.; Beckmann, N.A.; Lehner, B.; Omlor, G.W. Hip spacers with a metal-on-cement articulation did not show significant surface alterations of the metal femoral head in two-stage revision for periprosthetic joint infection. Materials 2020, 13, 3882. [Google Scholar] [CrossRef]
  21. Fabritius, M.; Al-Munajjed, A.A.; Freytag, C.; Julke, H.; Zehe, M.; Lemarchand, T.; Arts, J.J.; Schumann, D.; Alt, V.; Sternberg, K. Antimicrobial silver multilayer coating for prevention of bacterial colonization of orthopedic implants. Materials 2020, 13, 1415. [Google Scholar] [CrossRef] [Green Version]
  22. Xu, J.; Sonntag, R.; Kretzer, J.P.; Taylor, D.; Forst, R.; Seehaus, F. Model-based roentgen stereophotogrammetric analysis to monitor the head-taper junction in total hip arthroplasty in vivo-and they do move. Materials 2020, 13, 1543. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  23. Grupp, T.M.; Baxmann, M.; Jansson, V.; Windhagen, H.; Heller, K.D.; Morlock, M.M.; Knaebel, H.P. How to proceed with asymptomatic modular dual taper hip stems in the case of acetabular revision. Materials 2020, 13, 1098. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  24. Rieker, C.B.; Wahl, P. What the surgeon can do to reduce the risk of trunnionosis in hip arthroplasty: Recommendations from the literature. Materials 2020, 13, 1950. [Google Scholar] [CrossRef] [PubMed] [Green Version]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Kretzer, J.P.; Van Der Straeten, C. Special Issue “Novel Research about Biomechanics and Biomaterials Used in Hip, Knee and Related Joints”. Materials 2021, 14, 2222. https://doi.org/10.3390/ma14092222

AMA Style

Kretzer JP, Van Der Straeten C. Special Issue “Novel Research about Biomechanics and Biomaterials Used in Hip, Knee and Related Joints”. Materials. 2021; 14(9):2222. https://doi.org/10.3390/ma14092222

Chicago/Turabian Style

Kretzer, Jan Philippe, and Catherine Van Der Straeten. 2021. "Special Issue “Novel Research about Biomechanics and Biomaterials Used in Hip, Knee and Related Joints”" Materials 14, no. 9: 2222. https://doi.org/10.3390/ma14092222

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop