Next Article in Journal
α-Amidoamids as New Replacements of Antibiotics—Research on the Chosen K12, R2–R4 E. coli Strains
Next Article in Special Issue
Strain Hardening in an AZ31 Alloy Submitted to Rotary Swaging
Previous Article in Journal
Scaled Approach to Designing the Minimum Hybrid Reinforcement of Concrete Beams
Previous Article in Special Issue
Quasi-Situ Characterization of Retained Austenite Orientation in Quenching and Partitioning Steel via Uniaxial Tensile Tests
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Post-Processing Treatment Impact on Mechanical Properties of SLM Deposited Ti-6Al-4 V Porous Structure for Biomedical Application

1
Department of Mechanics, Biomechanics and Mechatronics, Faculty of Mechanical Engineering, Czech Technical University in Prague, Technická 1902/4, 16000 Prague, Czech Republic
2
Mechanical Testing and Thermophysical Measurement Department, COMTES FHT a.s., Průmyslová 995, 33441 Dobrany, Czech Republic
3
Department of Metals and Corrosion Engineering, University of Chemistry and Technology, Technická 5, 16628 Prague, Czech Republic
*
Author to whom correspondence should be addressed.
Materials 2020, 13(22), 5167; https://doi.org/10.3390/ma13225167
Submission received: 7 October 2020 / Revised: 30 October 2020 / Accepted: 12 November 2020 / Published: 16 November 2020

Abstract

:
Additive manufacturing technologies allow producing a regular three-dimensional mesh of interconnected struts that form an open-cell porous structure. Regular porous structures have been used in the orthopedic industry due to outstanding bone anchoring. The aim of the study was to determine how the postprocessing influences the mechanical properties of porous structures made of titanium alloy CL 41TI ELI. The effect of hot isostatic pressing (HIP) as a method of increasing microstructural integrity was investigated here. The influence of surface etching (SE) technique, which was applied to the porous structure for cleaning unmelted titanium powder particles on the surface of connectors from the inner surfaces of a porous structure, was examined in this study. Mechanical properties were investigated by means of compression tests. The results point out that HIP has a minor effect on the mechanical behavior of considered porous structures. The SE is an effective method to clean the surface of a porous structure, which is very important in the case of biomedical applications when loose powder can cause serious health problems. Another effect of the SE is also the strut thickness reduction. Reducing strut thickness of a porous structure with the surface etching decreases its stiffness to the same extent as predicted by the relative density theoretical model but did not result in structural damage.

1. Introduction

Additive Manufacturing (AM) is an innovative, rapidly developing technology utilized in the biomedical industry. The AM provides a custom shape freedom with lightweight structure optimization for replacing injured or diseased joints [1,2,3,4]. Additively manufactured joint and bone replacements are mostly made of biocompatible titanium and its alloys. However, solid titanium alloys are characterized by significantly higher stiffness than human bones. This mismatch in mechanical properties could limit bone ingrowth, speed up bone resorption and cause loosening of the orthopedic implant as a result of stress shielding [5,6,7]. The phenomenon is a reaction of bone to changing load conditions by its remodeling. The small porous and open-cell structures are arranged as repeating and connected unit cells and can be created by AM. This kind of architecture tends to reduce a stress gradient between the bone and the implant, and thus, promote a bone in-growth and improve osteointegration [8,9,10,11,12]. The mechanical properties of cellular structures can be further altered by an adjustment of open-cell architecture features, such as a strut thickness (relative density) and a material choice [13,14,15,16,17].
Three-dimensional porous structures can be prepared by using titanium powder by selective laser melting (SLM) belonging to powder bed fusion (PBF) technology [18,19,20,21,22,23]. In this system, the deposition process is conducted under a protective atmosphere of inert gas. Implants can be fabricated by melting a powder layer-by-layer using a laser beam as an energy source. After the deposition of a single material layer, a powder bed goes downwards, and the next powder layer is spread by a roller or re-coater. The process is continued until a whole structure is formed. The deposited bulk material could contain internal pores and defects as a result of gas entrapment in the powder particles or SLM deposition parameters selection [24,25]. These internal defects influence the static and fatigue strength, considerably acting as stress concentrators [13]. In other studies, it was demonstrated that hot isostatic pressing (HIP) could be an effective way of porosity reduction in AM-ed metals and their alloys [26,27,28]. Ahlfors et al. investigated the influence of HIP on the AM-ed titanium alloy [28]. The authors concluded that the fatigue performance and ductility of deposited parts could be significantly enhanced as a result of HIP treatment. While the influence of the HIP process is broadly documented for bulk structures, its potential advantage for open-cell architectures has not been extensively described yet.
The SLM method, as a layered fabrication process, produces not only internal defects but also a very rough surface. According to the research of Harun et al., a rough and highly porous structure potentially promotes the bone in-growth and on-growth [29]. Nonetheless, during the deposition process, some powder particles remain not fully melted and loosely attached to the implant surface. These particles remarkably increase the risk of contamination after surgery. In other studies, it was proposed that the released titanium particles can have adverse long-term metabolic, oncogenic and immunologic effects [30,31,32]. Mombelli et al. concluded that the reaction of human tissues to the adjacent titanium implant is very complex, where the presence of titanium particles, the process of tribo-corrosion and the development of inflammation influence each other [30]. According to the study of Heringa et al., the accumulation of titanium in a human body can lead to liver damage [33]. The research of Woodman et al. also demonstrates an effect of ion release from titanium-based implants as damaging to the vital human organs, namely liver and kidney [34]. It was suggested that the separation of any unmelted powder particle from porous structure could lead to critical liver failure [32]. Thus, a thorough surface cleanup is highly recommended for any product used for commercial orthopedic purposes. The removal of loosely connected powder particles can be conducted by means of machining and polishing (mechanical or chemical).
Due to the increased risk of serious health problems of a patient, the process of implant cleaning is considered essential for further application. It was proposed that a chemical or electrochemical process could be used to remove surface powder [35]. Such a process is not specific to powder and also affects the bulk material, namely strut dimensions and porosity. Therefore, a chemical treatment of porous structure is a stochastic process that depends on the local surface quality and could considerably compromise the mechanical properties of porous samples. However, the surface etching slightly affects surface chemistry and thus corrosion behavior. The corrosion rate is higher than in the case of a non-etched surface. Nevertheless, cytocompatibility remains at the same level as for untreated surfaces [36].
In this study, a porous design of cubical testing specimens was derived from the commercially available acetabulum augments implant, as presented in Figure 1. The surface was cleaned by chemical etching for as-built, and HIP treated specimens. The aim of this study was to determine if and to what extend (a) the HIP treatment and (b) the chemical etching affects the mechanical properties in porous specimens.

2. Materials and Methods

The specimens were fabricated using Concept Laser titanium alloy grade 23 (CL 41TI ELI, Concept Laser GmbH, Lichtenfels, Germany) powder [38]. In order to design the computer models of cubical specimens, a computer-aided design package SolidWorks (Version 27, Dassault Systemes SolidWorks Corp., Waltham, MA, USA) and Materialise/Magics (Magics, version 23, Leuven, Belgium) software were employed. The dimensions of a cubical specimen were set up as 6 mm with a single rhombic dodecahedron open unit-cell of 2 mm, as can be seen in Figure 2. An individual rhombic dodecahedron unit cell is composed of 12 identical rhombic faces with 24 edges and 14 vertices [17]. The length of the strut (l) was 0.87 mm. The constant angles between connectors were designed as 2α = 70.53° and 2θ = 109.47°. The strut was characterized by a thickness of 0.3 mm that yielded a relative density of 20%. The connector struts were designed as circular.
The deposition process was conducted using a M2 fusing machine (Concept Laser GmbH, Lichtenfels, Germany), adopting the SLM method. The SLM process was performed according to the manufacturer’s recommendation. The SLM deposition parameters are summarized in Table 1. Prior to the deposition process, a building chamber was not preheated. Concept Laser’s ‘island’ scanning strategy was applied [39].
The HIP treatment was applied in order to reduce the internal defects, increase structural integrity and potentially improve the mechanical properties of the deposited structures. The HIP was carried out by Bodycote Bourgogne (Bodycote HIP Ltd., Magny-Cours, France). The process was conducted under a protective argon gas atmosphere of 1020 bars. The specimens were heated up to 900 °C in 5 h and held at 900 °C for 4 h in steady isostatic pressure. Subsequently, the specimens were cooled down to room temperature in 5 h. The specimens were divided into 6 batches according to the applied posttreatment method, where each batch contained 4 specimens for statistical analysis. The specimen designation system, the number of specimens and the corresponding postprocessing method are summarized in Table 2.
The surface etching was aimed to decrease the surface roughness and to remove partly unmelted surface powders. The surface treatment started with 5 min degreasing in ethanol in an ultrasonic bath. Then, the specimens were etched for a defined time (3 min or 6 min) in a solution of 20 mL HF, 200 mL HNO3 and 780 mL demineralized water in the ultrasonic bath. The specimens were etched in batches of six pieces so that the etching bath volume was high enough to guarantee the success of the process. The specimens were subsequently washed with demineralized water (in the ultrasonic bath) and finally dried by air steam.
The etching conditions were selected based on the previous study of authors. Six minutes is the minimal time to achieve a surface with no partially melted particles [36]. The measurements of the cross-sectional area of the cubical specimens were performed by means of a digital micrometer (Mitutoyo, Mitutoyo Corporation, Tokyo, Japan) for all specimens.
In order to determine a geometrical accuracy and thus, identify the effect of applied postprocessing, a connector strut thickness and cross-sectional area were measured using a scanning electron microscope (SEM) Tescan VEGA-3 LMU (Tescan, Brno, Czech Republic) with ImageJ software (1.52i, NIH, MD, USA) [40]. The SEM is based on a secondary electron (SE) signal detection and operates at 20 kV. The strut thickness was measured on two specimens per batch. Forty-five measurements per specimen were performed that corresponds to approximately two records per each strut.
The mechanical compression tests were carried out with MTS 858 Mini Bionix testing machine (MTS, Eden Prairie, MN, USA) with a load cell of capacity 5 kN. The loading speed of a crosshead was set up as a constant 0.1 mm/min. The elastic gradient was determined in accordance with the standard ISO 13314 and calculated as the slope of the stress–strain curves between 30% and 70% of the plateau strength. The compressive proof stress and maximum first strength values were determined from the diagram using a 0.2% offset method, as is shown in Figure 3.
Theoretical relative density, elastic modulus and yield strength were calculated based on A. A. Zadpoor et al., R. Hedayati et al. and S. M. Ahmadi et al. studies [41,42,43].
The relative density formula is [42]:
ρ = 3 3 2 π ( r l ) 2 27 2 4 π ( r l ) 3
The analytical elastic modulus formula is [43]:
E 1 E s = E 2 E s = 27 s i n θ s i n 2 θ 3 l 4 π r 4 + 18 l 2 π r 2
The analytical yield stress modulus formula is [42]:
σ y 1 σ y s = σ y 2 σ y s = 3 4 4 ρ 3 2

3. Results

Figure 4 presents the surface etching effect on the specimens in as-built and HIP-treated states. The surface etching caused the removal of partly melted powder particles from the struts and the creation of a smoother surface. Removing of a covering layer of the surface resulted in a reduction of the strut thickness up to 14%, as presented in Table 2. The struts subjected to the etching achieved a clear beam form and homogenous shape. The HIP treatment resulted in a reduction of the strut diameter slightly. The decrease in the cross-sectional area could be observed not only at the strut level but also at the porous specimen total cross-sectional area, as summarized in Figure 5. A comparison of the strut thicknesses with corresponding mechanical characterictics obtained experimentally and using analytic model for the specimens in as-built, HIP-ed and etched states is presented in Table 3.
The elastic gradient was calculated in accordance with the ISO 13,314 guidelines by elastic loading and unloading [44]. The observed decrease in the elastic gradient trend may be caused by the reduced strut thickness, as it was predicted by the analytical model. The specimens after HIP treatment (H) achieved a 5.88% higher elastic modulus value than as-built specimens (B). The lowest elastic gradient was recorded for the specimens after 6 min surface treatment (B6) (1.23 ± 0.08 GPa), as presented in Figure 6.
The strut thinning that was a result of the surface etching led to a decrease of compressive proof stress as expected by analytic calculation. The compressive proof stress of porous specimens was not significantly affected by HIP. The specimens after both HIP and 6 min surface treatment (H6) were distinguished by the lowest level of compressive proof stress that reached 28.49 ± 1.24 MPa, as can be seen in Figure 7.

4. Discussion

Strut thickness and cross-sectional area influence the mechanical performance of open-cell porous structures [45]. In the present study, the surface etching led to a decrease of the strut thickness (Table 2), and thus, the mechanical response of the porous structure has changed accordingly, as presented in Figure 6 and Figure 7. The observed trend is in agreement with theoretical predictions. The predicted values are within the same range as the experimentally measured ones for as-built, HIP and 3 min etched specimens. However, the mechanical parameters for the specimens after 6 min etching are slightly higher than the values predicted on the basis of the strut thickness. It indicates that other mechanisms than a simple reduction of the strut thickness should be considered. For example, it could be assumed that the joints of the unit cell are not affected by etching proportionally (Figure 4) that is not included considerably by the analytic calculation.
The etching may be promoted on the surface defects of individual struts that could potentially lead to local weakening. An inconsistent structure can provide a nonuniform deformation while compressive loading, which suggests that the equivalent connector struts deal with the different loading. Such local structural differences would result in various mechanical response observed between the individual specimens within the same group exhibited as a large variance within the group. Within the present study, such behavior was not confirmed. Despite rough structure in as-built specimens (Figure 3), the recorded values exhibited relatively low data scatter. The surface roughness contributes to the deviation of strut diameter values; nonetheless, the variations between the mechanical response of the specimens increased only slightly (Figure 6 and Figure 7).
The specimen post-deposition treatment can affect the effectiveness of surface etching. The specimens in the as-built state, subjected to 3 min etching (B3), were characterized by a reduced relative density by 7.27% in comparison to the specimens in an initial state (B). In the case of the HIP-ed specimens (H and H3), the etching led to relative density reduction by 3.70%, as shown in Table 2. In addition, the total change in relative density after 6 min etching was 12.03% and 11.14% for the specimens in as-built (B6) and post-treated (H6) states, respectively. A similar trend can be observed in overall porous specimen dimensions, as illustrated in Figure 5.
According to Song et al. [46] and Oh et al. [47], a reduction in internal defects should considerably increase the elastic modulus of a solid structure. Furthermore, HIP treatment also decreases internal defect size and increase the elastic gradient. Although a similar behavior was recorded for porous structure in the present study, the observed effect was minor. The highest value of the elastic gradient was noticed for the unetched batch subjected to the HIP treatment (H), and it was only 5% higher than for the porous specimens in the as-built state (B). On the other hand, the lowest elastic gradient values were recorded for the as-built 6 min and 3 min etched batches (B6 and B3), reaching 1.23 and 1.31 GPa, respectively.
In this study, the etched porous structures were assessed to be more compliant for medical applications than those subjected only to the HIP treatment. Obtaining similar values of mechanical characteristics for a human bone and deposited porous structures is desirable for joint replacements and result in the reduction of stress shielding, decrease the risk of implant loosening as well as an extension of the implant lifetime [48]. Surface etching also provides an excellently clean product (Figure 4), free of unmelted powder surface particles that could potentially lead to the damage of vital human organs. Preventing the release of titanium particles from the implant is essential for any future biomedical application.

5. Conclusions

In the present study, the effect of HIP treatment and surface etching on the mechanical properties of porous specimens was investigated. It was shown that HIP processing is not considered effective for porous structures. However, surface etching appears to be an appropriate method as a post-deposition treatment of the porous structures for biomedical implants. By erosion of loosely attached particles from the surface, it prevents contamination of the human body by titanium particles. Furthermore, it lowers the elastic gradient and provides consistent mechanical properties. The material removed by etching slightly decreases the strength of the whole porous structure due to load-bearing cross-section reduction.

6. Future Works

Reflecting on an application of open-cell structures in biomedicine, many other factors must be taken into consideration and investigated in detail. The presented examination was performed with a static compression test in ambient conditions. However, the porous structures being implanted into the human body are supposed to deal with dynamic loading conditions in blood-like material and the environment of body fluids. These fluids and cells penetrate the porous structure that can induce a corrosion process of the implant [36,49]. This effect can lead to disruption of the physiological ion movement in human nerve cells. In addition, in vivo environment can lead to an increase of the open-cell structure density and strength as a result of the interpenetrating phase composites effect [50].

Author Contributions

Conceptualization, M.D. and J.D.; methodology, R.S.; investigation, E.P. and J.F.; writing—original draft preparation, E.P. and S.R.; writing—review and editing, M.D., J.D. and S.R.; supervision, M.D. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the project of the Czech Technical University in Prague No. SGS19/155/OHK2/3T/12, Ministry of Health of the Czech Republic, grant nr. NU20-06-00424 and by Ministry of Education, Youth and Sports No. EF17_048/0007350.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Li, J.; Cui, X.; Hooper, G.J.; Lim, K.S.; Woodfield, T.B.F. Rational design, bio-functionalization and biological performance of hybrid additive manufactured titanium implants for orthopaedic applications: A review. J. Mech. Behav. Biomed. Mater. 2020, 105, 1–18. [Google Scholar] [CrossRef] [PubMed]
  2. Singh, S.; Ramakrishna, S.; Singh, R. Material issues in additive manufacturing: A review. J. Manuf. Process. 2017, 25, 185–200. [Google Scholar] [CrossRef]
  3. Liu, S.; Shin, Y.C. Additive manufacturing of Ti6Al4V alloy: A review. Mater. Des. 2019, 164, 1–23. [Google Scholar] [CrossRef]
  4. Warnke, P.H.; Douglas, T.E.L.; Wollny, P.; Sherry, E. Rapid prototyping: Porous titanium alloy scaffolds produced by selective laser melting for bone tissue engineering. Tissue Eng. Part C Methods 2009, 15, 115–124. [Google Scholar] [CrossRef] [Green Version]
  5. Niinomi, M. Mechanical properties of biomedical titanium alloys. Mater. Sci. Eng. A 1998, 243, 231–236. [Google Scholar] [CrossRef]
  6. Engh, C.A.; Bobyn, J.D.; Glassman, A.H. Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. Bone Jt. J. 1987, 69, 45–55. [Google Scholar] [CrossRef]
  7. Nagels, J.; Stokdijk, M.; Rozing, P.M. Stress shielding and bone resorption in shoulder arthroplasty. J. Shouder Elb. Surg. 2003, 12, 35–39. [Google Scholar] [CrossRef]
  8. Zhang, X.Y.; Fang, G.; Leeflang, S.; Zadpoor, A.A.; Zhou, J. Topological design, permeability and mechanical behavior of additively manufactured functionally graded porous metallic biomaterials. Acta Biomater. 2019, 84, 437–452. [Google Scholar] [CrossRef]
  9. Murr, L.E. Metallurgy principles applied to powder bed fusion 3D printing/additive manufacturing of personalized and optimized metal and alloy biomedical implants: An overview. J. Mater. Res. Technol. 2020, 9, 1087–1103. [Google Scholar] [CrossRef]
  10. Majumdar, T.; Eisenstein, N.; Frith, J.E.; Cox, S.C.; Birbils, N. Additive manufacturing of titanium alloys for orthopedic applications: A materials science viewpoint. Adv. Eng. Mater. 2018, 20, 1–28. [Google Scholar] [CrossRef]
  11. Chamay, A.; Tschantz, P. Mechanical influences in bone remodeling. Experimental research on Wolff’s law. J. Biomech. 1972, 5, 173–180. [Google Scholar] [CrossRef]
  12. Bigerelle, M.; Anselme, K. A kinetic approach to osteoblast adhesion on biomaterial surface. J. Biomed. Mater. Res. Part A 2005, 75, 530–540. [Google Scholar] [CrossRef] [PubMed]
  13. Zhang, X.Z.; Leary, M.; Tang, H.P.; Song, T.; Qian, M. Selective electron beam manufactured Ti-6Al-4V lattice structures for orthopedic implant applications: Current status and outstanding challenges. Curr. Opin. Solid State Mater. Sci. 2018, 22, 75–99. [Google Scholar] [CrossRef]
  14. Wieding, J.; Jonitz, A.; Bader, R. The effect of structural design on mechanical properties and cellular response of additive manufactured titanium scaffolds. Materials 2012, 5, 1336–1347. [Google Scholar] [CrossRef]
  15. Do, D.K.; Li, P. The effect of laser energy input on the microstructure, physical and mechanical properties of Ti-6Al-4V alloys by selective laser melting. Virtual Phys. Prototyp. 2016, 11, 41–47. [Google Scholar] [CrossRef]
  16. Elias, C.N.; Lima, J.H.C.; Valiev, R.; Meyers, M.A. Biomedical applications of titanium and its alloys. JOM 2008, 60, 46–49. [Google Scholar] [CrossRef]
  17. Okazaki, Y.; Ito, Y.; Kyo, K.; Tateishi, T. Corrosion resistance and corrosion fatigue strength of new titanium alloys for medical implants without V and Al. Mater. Sci. Eng. A 1996, 213, 138–147. [Google Scholar] [CrossRef]
  18. Pehlivan, E.; Roudnicka, M.; Dzugan, J.; Koukolikova, M.; Králík, V.; Seifi, M.; Lewandowski, J.J.; Dalibor, D.; Daniel, M. Effects of build orientation and sample geometry on the mechanical response of miniature CP-Ti Grade 2 strut samples manufactured by laser powder bed fusion. Addit. Manuf. 2020, 35, 1–10. [Google Scholar] [CrossRef]
  19. Attar, H.; Calin, M.; Zhang, L.C.; Scudino, S.; Eckert, J. Manufacture by selective laser melting and mechanical behavior of commercially pure titanium. Mater. Sci. Eng. A 2014, 593, 170–177. [Google Scholar] [CrossRef]
  20. Sercombe, T.B.; Li, X. Selective laser melting of aluminium and aluminium metal matrix composites: Review. Mater. Technol. 2016, 31, 77–85. [Google Scholar] [CrossRef]
  21. Seede, R.; Mostafa, A.; Brailovski, V.; Jahazi, M.; Medraj, M. Microstructural and microhardness evolution from homogenization and hot isostatic pressing on selective laser melted inconel 718: Structure, texture, and phases. J. Manuf. Mater. Process. 2018, 2, 30. [Google Scholar] [CrossRef] [Green Version]
  22. Patel, R.; Hirsch, M.; Dryburgh, P.; Pieris, D.; Achamfuo-Yeboah, S.; Smith, R.; Light, R.; Sharples, S.; Clare, A.; Clark, M. Imaging material texture of as-deposited selective laser melted parts using spatially resolved acoustic spectroscopy. Appl. Sci. 2018, 8, 1991. [Google Scholar] [CrossRef] [Green Version]
  23. Khoo, Z.X.; An, J.; Chua, C.K.; Shen, Y.F.; Kuo, C.N.; Liu, Y. Effect of heat treatment on repetitively scanned SLM NiTi shape memory alloy. Materials 2019, 12, 77. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  24. Fousová, M.; Vojtěch, D.; Doubrava, K.; Daniel, M.; Lin, C.F. Influence of inherent surface and internal defects on mechanical properties of additively manufactured Ti6Al4V alloy: Comparison between selective laser melting and electron beam melting. Materials 2018, 11, 537. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  25. Gotterbarm, M.R.; Seifi, M.; Melzer, D.; Dzugan, J.; Salem, A.A.; Liu, Z.H.; Korner, C. Small scale testing of IN718 single crystals manufactured by EB-PBF. Addit. Manuf. 2020, 36, 1–14. [Google Scholar] [CrossRef]
  26. Shipley, H.; McDonnell, D.; Culleton, M.; Lupoi, R.; O’Donnell, G.; Trimble, D. Optimisation of process parameters to address fundamental challenges during selective laser melting of Ti-6Al-4V: A review. Int. J. Mach. 2018, 128, 1–20. [Google Scholar] [CrossRef]
  27. Kuo, Y.-L.; Nagahari, T.; Kakehi, K. The effect of post-processes on the microstructure and creep properties of alloy718 built up by selective laser melting. Materials 2018, 11, 996. [Google Scholar] [CrossRef] [Green Version]
  28. Ahlfors, M.; Bahbou, F.; Ackelid, U. Optimizing HIP and Printing Parameters for EBM Ti-6Al-4V. Quintus Technologies 2018. Available online: https://quintustechnologies.com/knowledge-center/white-paper-optimizing-hip-and-printing-parameters-for-ebm-ti-6al-4v/ (accessed on 28 October 2020).
  29. Harun, W.S.W.; Kamariah, M.S.I.N.; Muhamad, N.; Ghani, S.A.C.; Ahmad, F.; Mohamed, Z. A review of powder additive manufacturing processes for metallic biomaterials. Powder Technol. 2018, 327, 128–151. [Google Scholar] [CrossRef]
  30. Mombelli, A.; Hashim, D.; Cionca, N. What is the impact of titanium particles and biocorrosion on implant survival and complications? A critical review. Clin. Oral Implant. Res. 2018, 29, 37–53. [Google Scholar] [CrossRef]
  31. Hlinka, J.; Kvicala, M.; Lasek, S. Corrosion properties of porous titanium sinteres with sodium chloride. In Proceedings of the METAL 2015—24th International Conference on Metallurgy and Materials, Brno, Czech Republic, 3–5 June 2015. [Google Scholar]
  32. Frisken, K.W.; Dandie, G.W.; Lugowski, S.; Jordan, G. A study of titanium release into body organs following the insertion of single threaded screw implants into the mandibles of sheep. Aust. Dent. J. 2002, 47, 214–217. [Google Scholar] [CrossRef] [Green Version]
  33. Heringa, M.B.; Peters, R.; Bleys, R.L.A.W. Detection of titanium particles in human liver and spleen and possible health implications. Part. Fibre Toxicol. 2018, 15, 1–9. [Google Scholar] [CrossRef] [PubMed]
  34. Woodman, J.L.; Jacobs, J.J.; Galante, J.O.; Urban, R.M. Metal ion release from titanium-based prosthetic segmental replacements of long bones in baboons: A long-term study. J. Orthop. Res. 1984, 1, 421–430. [Google Scholar] [CrossRef] [PubMed]
  35. Bartolo, P.; Kruth, J.P.; Silva, J.; Levy, G.; Malshe, A.; Rajurkar, K.; Mitsuishi, M.; Ciurana, J.; Leu, M. Biomedical production of implants by additive electro-chemical and physical processes. CIRP Ann. Manuf. Technol. 2012, 61, 635–655. [Google Scholar] [CrossRef]
  36. Fojt, J.; Kacenka, Z.; Jablonska, E.; Hybasek, V.; Pruchova, E. Influence of the surface etching on the corrosion behaviour of a three-dimensional printed Ti–6Al–4V alloy. Mater. Corros. 2020. [Google Scholar] [CrossRef]
  37. Pehlivan, E. Developing Trabecular Structure. Ph.D. dissertation, Czech Technical University in Prague, Prague, Czechia, 2019. [Google Scholar]
  38. CONCEPTLASER CL 41TI ELI Titanium Alloy. Available online: https://www.ge.com/additive/sites/default/files/2018-12/CLMAT_41TI%20ELI_DS_EN_US_2_v1.pdf (accessed on 1 October 2020).
  39. Ter Haar, G.M.; Becker, T.H. Selective laser melting produced Ti-6Al-4V: Post-process heat treatments to achieve superior tensile properties. Materials 2018, 11, 146. [Google Scholar] [CrossRef] [Green Version]
  40. Rueden, C.T.; Schindelin, J.; Hiner, M.C.; DeZonia, B.E.; Walter, A.E.; Arena, E.T.; Eliceiri, K.W. ImageJ2: ImageJ for the next generation of scientific image data. BMC Bioinform. 2017, 18, 1–26. [Google Scholar] [CrossRef]
  41. Zadpoor, A.A.; Hedayati, R. Analytical relationships for prediction of the mechanical properties of additively manufactured porous biomaterials. J. Biomed. Mater. Res. A 2016, 104, 3164–3174. [Google Scholar] [CrossRef]
  42. Hedayati, R.; Sadighi, M.; Mohammadi-Aghdam, M.; Zadpoor, A.A. Effect of mass multiple counting on the elastic properties of open-cell regular porous biomaterials. Mater. Des. 2016, 89, 9–20. [Google Scholar] [CrossRef]
  43. Ahmadi, S.M.; Yavari, S.A.; Wauthle, R.; Pouran, B.; Schrooten, J.; Weinans, H.; Zadpoor, A.A. Additively manufactured open-cell porous biomaterials made from six different space-filling unit cells: The mechanical and morphological properties. Materials 2015, 8, 1871–1896. [Google Scholar] [CrossRef] [Green Version]
  44. ISO. ISO 13314. Mechanical Testing of Metals Ductility Testing Compression Test for Porous and Cellular Metals; International Organization for Standardization: Geneva, Switzerland, 2011. [Google Scholar]
  45. Cheng, X.Y.; Li, S.J.; Murr, L.E.; Zhang, Z.B.; Hao, Y.L.; Yang, R.; Medina, F.; Wicker, R.B. Compression deformation behavior of Ti-6Al-4V alloy with cellular structures fabricated by electron beam melting. J. Mech. Behav. Biomed. Mater. 2012, 16, 153–162. [Google Scholar] [CrossRef]
  46. Song, Y.; Xu, D.S.; Yang, R.; Li, D.; Wu, W.T.; Guo, Z.X. Theoretical study of the effects of alloying elements on the strength and modulus of β-type bio-titanium alloys. Mater. Sci. Eng. A 2002, 260, 269–274. [Google Scholar] [CrossRef]
  47. Oh, I.H.; Nomura, N.; Masahashi, N.; Hanada, S. Microstructures and mechanical properties of porous titanium compacts prepared by powder sintering. Mater. Trans. 2003, 49, 1197–1202. [Google Scholar] [CrossRef] [Green Version]
  48. Krishna, B.V.; Bose, S.; Bandyopadhyay, A. Low stiffness porous Ti structures for load-bearing implants. Acta Biomater. 2007, 3, 997–1006. [Google Scholar] [CrossRef] [PubMed]
  49. Shirazi, S.F.S.; Gharehkhani, S.; Mehrali, M.; Yarmand, H.; Metselaar, H.S.C.; Kadri, N.A.; Osman, N.A.A. A review on powder-based additive manufacturing for tissue engineering: Selective laser sintering and inkjet 3D printing. Sci. Technol. Adv. Mater. 2015, 16, 1–20. [Google Scholar] [CrossRef]
  50. Clarke, D.R. Interpenetrating phase composites. J. Am. Ceram. Soc. 1992, 75, 739–759. [Google Scholar] [CrossRef]
Figure 1. (A) Acetabulum metal augments implant with rhombic dodecahedron porous structure surface and (B) rhombic dodecahedron cubical element [37].
Figure 1. (A) Acetabulum metal augments implant with rhombic dodecahedron porous structure surface and (B) rhombic dodecahedron cubical element [37].
Materials 13 05167 g001
Figure 2. Compression specimen dimensions (left), a single unit cell dimensions (middle) and rhombic dodecahedron unit-cell (right).
Figure 2. Compression specimen dimensions (left), a single unit cell dimensions (middle) and rhombic dodecahedron unit-cell (right).
Materials 13 05167 g002
Figure 3. Elastic gradient calculation in accordance with the standard ISO 13,314. The compression stress–strain diagram with a marked elastic gradient tangent of ‘’θ’’. A 0.2% offset compressive proof stress is designated as “B” and maximum first stress is designated as “A” [37].
Figure 3. Elastic gradient calculation in accordance with the standard ISO 13,314. The compression stress–strain diagram with a marked elastic gradient tangent of ‘’θ’’. A 0.2% offset compressive proof stress is designated as “B” and maximum first stress is designated as “A” [37].
Materials 13 05167 g003
Figure 4. Secondary electron micrographs of the representative specimens selected from each tested batch. Comparison of the postprocessing effect on a specimen surface (batch/strut thickness in ( × 0.001) mm): (a) as-built specimen with original surface (B/322 ± 21); (b) as-built specimen after 3 min etching (B3/277 ± 21); (c) as-built specimen after 6 min etching (B6/243 ± 21); (d) HIP-ed specimen with original surface (H/310 ± 23); (e) HIP-ed specimen after 3 min etching (H3/287 ± 21); (f) HIP-ed specimen after 6 min etching (H6/234 ± 18) [37].
Figure 4. Secondary electron micrographs of the representative specimens selected from each tested batch. Comparison of the postprocessing effect on a specimen surface (batch/strut thickness in ( × 0.001) mm): (a) as-built specimen with original surface (B/322 ± 21); (b) as-built specimen after 3 min etching (B3/277 ± 21); (c) as-built specimen after 6 min etching (B6/243 ± 21); (d) HIP-ed specimen with original surface (H/310 ± 23); (e) HIP-ed specimen after 3 min etching (H3/287 ± 21); (f) HIP-ed specimen after 6 min etching (H6/234 ± 18) [37].
Materials 13 05167 g004
Figure 5. Comparison of the cross-sectional area of porous specimens subjected to various postprocessing methods [37].
Figure 5. Comparison of the cross-sectional area of porous specimens subjected to various postprocessing methods [37].
Materials 13 05167 g005
Figure 6. The effect of posttreatment on strut thickness and elastic gradient of the porous structure. The analytical model prediction is based on the change of strut thickness [37].
Figure 6. The effect of posttreatment on strut thickness and elastic gradient of the porous structure. The analytical model prediction is based on the change of strut thickness [37].
Materials 13 05167 g006
Figure 7. The effect of posttreatment on strut thickness and compressive proof stress of the porous structure. The analytical model prediction is based on the change of strut thickness [37].
Figure 7. The effect of posttreatment on strut thickness and compressive proof stress of the porous structure. The analytical model prediction is based on the change of strut thickness [37].
Materials 13 05167 g007
Table 1. Summary of applied selective laser melting (SLM) deposition parameters.
Table 1. Summary of applied selective laser melting (SLM) deposition parameters.
Deposition Parameters
Laser beam power200 W
Scan speed7 mm/s
Layer thickness20 µm
Offset distance75 µm
Table 2. Experiment plan-specimen designation system, corresponding group definition and number of specimens per conditions.
Table 2. Experiment plan-specimen designation system, corresponding group definition and number of specimens per conditions.
Group DesignationPostprocessing ParametersNumber of Specimens
BNo heat (as-built)4
HHIP treatment4
B3Surface treatment 3 min4
B6Surface treatment 6 min4
H3HIP treatment and surface treatment 3 min4
H6HIP treatment and surface treatment 6 min4
Table 3. Comparison of strut thickness and mechanical parameters measured and predicted by the analytic model for the specimen batches subjected to various postprocessing methods.
Table 3. Comparison of strut thickness and mechanical parameters measured and predicted by the analytic model for the specimen batches subjected to various postprocessing methods.
Gr.Strut Thickness
( × 0.001) mm
Relative Density%Compressive Proof Stress Theoretical MPa (σ)Compressive Proof Stress Experiment MPa (σ)Elastic Gradient Theoretical GPa (E)Elastic Gradient Experiment GPa (E)
B322 ± 2127.9443.8638.70 ± 0.632.621.76 ± 0.05
B3277 ± 2120.6727.9231.66 ± 1.661.501.31 ± 0.13
B6243 ± 2115.9118.8530.11 ± 0.430.921.23 ± 0.08
H310 ± 2325.8939.1438.13 ± 0.552.281.87 ± 0.05
H3287 ± 2122.1931.0531.50 ± 0.941.711.48 ± 0.11
H6234 ± 1814.7516.8328.49 ± 1.240.791.34 ± 0.06
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Pehlivan, E.; Džugan, J.; Fojt, J.; Sedláček, R.; Rzepa, S.; Daniel, M. Post-Processing Treatment Impact on Mechanical Properties of SLM Deposited Ti-6Al-4 V Porous Structure for Biomedical Application. Materials 2020, 13, 5167. https://doi.org/10.3390/ma13225167

AMA Style

Pehlivan E, Džugan J, Fojt J, Sedláček R, Rzepa S, Daniel M. Post-Processing Treatment Impact on Mechanical Properties of SLM Deposited Ti-6Al-4 V Porous Structure for Biomedical Application. Materials. 2020; 13(22):5167. https://doi.org/10.3390/ma13225167

Chicago/Turabian Style

Pehlivan, Eren, Jan Džugan, Jaroslav Fojt, Radek Sedláček, Sylwia Rzepa, and Matej Daniel. 2020. "Post-Processing Treatment Impact on Mechanical Properties of SLM Deposited Ti-6Al-4 V Porous Structure for Biomedical Application" Materials 13, no. 22: 5167. https://doi.org/10.3390/ma13225167

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop