Next Article in Journal
An Ab Initio RRKM-Based Master Equation Study for Kinetics of OH-Initiated Oxidation of 2-Methyltetrahydrofuran and Its Implications in Kinetic Modeling
Next Article in Special Issue
European DEMO Fusion Reactor: Design and Integration of the Breeding Blanket Feeding Pipes
Previous Article in Journal
Estimating the Performance Loss Rate of Photovoltaic Systems Using Time Series Change Point Analysis
Previous Article in Special Issue
High Heat Flux Testing of Graded W-Steel Joining Concepts for the First Wall
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Development of a Steam Generator Mock-Up for EU DEMO Fusion Reactor: Conceptual Design and Code Assessment

1
Department of Astronautical, Electrical and Energy Engineering (DIAEE), Sapienza University of Rome, 00186 Roma, Italy
2
Department of Fusion and Nuclear Safety Technology (ENEA), 00044 Rome, Italy
3
Department of Fusion and Nuclear Safety Technology (ENEA), Camugnano, 40032 Bologna, Italy
4
CREATE Consortium, Università di Napoli Federico II, 80125 Napoli, Italy
*
Author to whom correspondence should be addressed.
Energies 2023, 16(9), 3729; https://doi.org/10.3390/en16093729
Submission received: 1 March 2023 / Revised: 17 April 2023 / Accepted: 24 April 2023 / Published: 26 April 2023

Abstract

:
Recent R&D activities in nuclear fusion have identified the DEMO reactor as the ITER successor, aiming at demonstrating the technical feasibility of fusion plants, along with their commercial exploitation. However, the pulsed operation of the machine causes an “unconventional” operation of the system, posing unique challenges to the functional feasibility of the steam generator, for which it is necessary to define and qualify a reference configuration for DEMO. In order to facilitate the transitions between different operational regimes, the Once Through Steam Generator (OTSG) is considered to be a suitable choice for the DEMO primary heat transfer systems, being characterized by lower thermal inertia with respect to the most common U-tube steam generators. In this framework, the ENEA has undertaken construction of the STEAM facility at Brasimone R.C., aiming at characterizing the behavior of the DEMO OTSG and related water coolant systems in steady-state and transient conditions. A dedicated OTSG mock-up has been conceived and designed, adopting a scaling procedure, keeping the height 1:1 of the DEMO OTSGs. The conceptual design has been supported by RELAP5/Mod3.3 thermal-hydraulic calculations. CFD and FEM codes have been used for fluid-dynamic analyses and mechanical stress analyses, respectively, in specific parts of the component.

1. Introduction

In recent years, relevant R&D activities on fusion technology have led to the conceptualization of the DEMO (DEMOnstration Power Station) reactor [1], an evolution of the ITER experimental reactor [2]. These efforts aim at demonstrating the fusion reactor feasibility and its electricity production at competitive prices with respect to other energy sources [3]. The complexity of the fusion machine design has led European countries to focus their research efforts by founding EUROfusion, a European consortium for nuclear fusion development [4].
As a partner of the EUROfusion Consortium, ENEA (Italian National Agency for New Technologies, Energy and Sustainable Economic Development) pursues R&D activities to develop the Water Cooled Lithium Lead (WCLL) Breeding Blanket (BB) design [5], selected as the driver concept for DEMO, in the framework of the BB and Balance of Plant (BoP) work packages of the EUROfusion Power Plant Physics and Technology Programme.
One of the peculiar features of the fusion machines is the pulsed power generation from the plasma, which determines unique challenges to the functional feasibility of the components [6], especially of the heat sink (i.e., steam generator), making it necessary to define reliable control logics, capable of distinguishing the operational transients (i.e., pulse-dwell-pulse phases) from the accidental ones.
The “unconventional” operation of the fusion reactor has led to the selection of the Once Through Steam Generator (OTSG) as the main heat sink [7] since it is characterized by lower thermal inertia with respect to the most common U-tube generators, and therefore, it is more suitable for following the variability of the power load. The research activity has to demonstrate the possibility of translating the well-proven Pressurizer Water Reactor (PWR) technology in a fusion reactor plant.
In this framework, a new multipurpose experimental infrastructure, named W-HYDRA, will be designed, constructed and operated at ENEA Brasimone R.C. Among the facilities constituting this new platform, STEAM [8] is designed to experimentally investigate the DEMO BoP, focusing on the Steam Generator (SG) of the BB Primary Heat Transfer Systems (PHTSs). The STEAM facility will be mainly made up of two loops reproducing the DEMO PHTS and Power Conversion System (PCS), respectively, thermally coupled by means of the test section (i.e., the OTSG), which is a scaled-down mock-up of the DEMO OTSGs.
A design activity has been performed to achieve a preliminary layout of the OTSG mock-up to be installed in the STEAM facility. Such a study has been supported by means of a Thermal-Hydraulic (TH) analysis of this component using the SYStem TH (SYS-TH) code RELAP5/Mod3.3 [9]. The conceptualization of the STEAM OTSG starts from the preliminary qualification of the RELAP5/Mod3.3 code against experimental data related to the correspondent component installed in the Three Mile Island (TMI) nuclear power plant. After that, the sizing of the Breeding Zone (BZ) OTSG has been performed and its TH performances during DEMO normal operations have been fully characterized [10]. Finally, a scaling procedure has been applied to the BZ OTSG to design the STEAM mock-up [8]. Different configurations have been analyzed with the RELAP5/Mod3.3 code and further optimization has been implemented to obtain a configuration suitable for the facility requirements. In addition, CFD analyses on the riser tube support plates (i.e., grids) and Thermo-Mechanical (TM) analyses on the tube sheet have been carried out and are presented in the following.

2. RELAP5/Mod3.3 Model Qualification through TMI OTSG Experimental Data

This paper focuses on the realization of a numerical model of the STEAM OTSG mock-up, aiming at supporting the design and the realization of the component and its integration in the circuit. The TH analysis and simulation of this component have been performed using the SYS-TH code RELAP5/Mod3.3.
A preliminary activity has been dedicated to the verification of the code capabilities in simulating the thermal-hydraulic behavior of an OTSG, in a configuration envisioned for the DEMO reactor. Among the builders of PWRs, Babcock and Wilcox (B&W) Company [11] is the only supplier of OTSGs [12,13]; therefore, the B&W OTSG of TMI power plant [14,15] has been taken as a reference for the analysis (see Figure 1, left). A 1-D numerical model has been set up using RELAP5/Mod3.3 (see Figure 2) reproducing both the primary side (PS), i.e., tube side, and the secondary side (SS), i.e., shell side, of the component.
RELAP5/Mod3.3 nodalization consists in an open loop that focuses on the component T/H investigation, neglecting the rest of the loop. Fluid boundary conditions (e.g., pressure and temperature) have been set by time-dependent volumes, while time-dependent junctions fix the mass flow rate.
Primary coolant enters the upper plenum through a single inlet nozzle (Figure 1, right), flows downward tube side and exits through two outlet nozzles in the lower plenum. Secondary fluid (i.e., feedwater) enters the OTSG through the circular header located above the mid-plane of the system in Figure 1. Water is injected in partially external pipes, whose internal part is equipped with 32 perforated nozzles. Feedwater is here sprayed downwards into the annular downcomer (DC) between the shell and the shroud up to the water ports, where it changes its direction entering the riser (the shell side region between the primary tubes and the shroud). The tube bundle is structurally supported by 16 grids (tube support plates, TSPs) characterized by a mutual distance of approximately 1 m. The main feature of the OTSG is the recirculation zone, placed slightly above the feedwater inlet nozzles, which allows steam bleeding from the tube bundle in order to pre-heat the feedwater up to saturation conditions in correspondence with the tube bundle inlet. Flowing up through the tube bundle, the water vaporizes achieving superheated steam conditions on the top. Then, the steam is collected inside the annular DC and it exits toward the steam line.
The active length axial nodalization of both the primary and secondary sides respects the slice modeling approach. After mesh sensitivity, the selected mesh size for the thermal height is about 20 cm. Heat structures have been introduced in the model of Figure 2 to simulate the thermal coupling between the primary side and secondary side (i.e., the tube bundle with HS 310-1 and the lower and upper tube sheets with HS 113-3), allowing in such a way the power exchange along the OTSG active region. The model also includes heat structures reproducing the thermal losses toward the environment (HS 113-4 and 312-1). The axial meshing of the heat structures is the result of the slice modeling approach. The radial conduction has been taken into account by dividing the heat structure thickness (that contains also the insulation thickness for passive structures) into 14 intervals.
The model described above has been used to perform a set of simulations aiming at qualifying it for its utilization during the scaling process. Results showed that higher mass flows allow the exchange of higher power. For this reason, keeping the primary mass flow constant, feedwater mass flow is regulated by a control system in order to achieve the required outlet primary side temperature. A higher feedwater mass flow leads to a higher power exchange, resulting in a decrease in the primary side outlet temperature. On the other hand, the higher the feedwater mass flow rate, the lower the outlet steam temperature, affecting negatively the efficiency of the thermodynamic cycle. As reported in Table 1, the code results show good agreement with the reference data reported in [14], demonstrating that the model is suitable to support the design of this SG type and to investigate its TH performances.

3. STEAM OTSG Mock-Up

The STEAM facility’s [8] main purpose is to demonstrate the DEMO OTSG [16] feasibility and its capability to exchange the produced power in all phases foreseen during DEMO normal operations (i.e., pulse, dwell and related transitions). For this reason, once the RELAP5 model has been qualified, an analytical methodology is developed to perform a preliminary evaluation and sizing of the DEMO WCLL BB PHTS OTSGs, leading to the thermal length reduction from 17 to 13 m. In doing so, the TSPs number has been reduced to 13, keeping the mutual distance of 1 m.
A scaling procedure has been then followed by applying the “power to volume” approach and keeping the full-length scale of the BZ OTSG. Assuming that the “power/tube” ratio is unchanged, and knowing the thermal loads, a mock-up (scaled 1:1 in length) has been conceived for the STEAM facility (3 MW).
Results of the scaling process show no major TH distortion nor instabilities but, keeping the same layout of the reference case, the obtained configuration has a DC annular gap 2 cm thick, which cannot be easily realized because of manufacturing tolerances of the coaxial pipes. Moreover, such a configuration would imply unavoidable distortions in preserving the pressure drop chain of the component, as well as issues with the installation of the instrumentation in the riser. For this reason, two different constructive solutions have been investigated, with one or two external DC tubes, respectively (Figure 3). This variation is pursued by adopting the DC scaled area for the case with one external pipe, and its half value for both the DCs in the case with two external pipes.
The adoption of one (or two) DC pipe(s) leads to the following distortions, which refer to Figure 3:
  • DC hydraulic diameter variation introduces distortions in the pressure drops;
  • the steam DC dead zone (below pipes 213 and 235) is neglected, without determining any influence on the results;
  • the dimensions of the inlet and outlet nozzles have not been scaled from TMI, but they have been assumed as the ones corresponding to the STEAM pipelines, introducing distortions of the correspondent pressure drops;
  • the Aspirator Port (AP), is simulated by the Single Junction (SJ) 223 both in the integrated DC and one external pipe DC configurations, while in the two external DCs case, the total recirculation area is split in half with SJ 223 and SJ 238. This causes differences in the pressure loss coefficients calculated across the riser-AP and AP-DC;
  • the multiple junction 220 used in the reference model of Figure 3a, simulating the eight Water Ports (WPs) that allow the feedwater to enter the tube bundle has been substituted with one (or two) SJ(s), for the case with one (or two) external DC(s). Such differences cause distortions of the singular pressure drops among the three configurations;
  • the shroud thickness has been changed accordingly to the different pressure it has to withstand in the case of integrated DC and one (or two) external DCs.
Table 2 summarizes the results of the simulations performed. As the main outcome, it is possible to conclude that, from a thermal-hydraulic point of view, the three OTSG configurations have almost the same performances as the BZ reference case, meaning that the scaling procedure has preserved the main features of the component.
The thermal decoupling of the riser and downcomer affects the heat losses toward the environment. In particular, Table 2 shows that the percentage of the heat losses increases with decreasing the power (i.e., the vessel O.D.) and with realizing external DC(s), since the ratio surface/volume of the component increases. The higher value of heat losses (0.98%) is achieved in the case of two external DCs. Heat losses also affect the values of void fraction achieved at the bottom of the DC, obtained by injecting a recirculation flow through the AP for the pre-heating along the DC. Since the heat losses along the DC increase, the final value of the void fraction at the DC bottom decreases, passing from the integrated DC solution to cases with external DC(s). However, the results show that the recirculation flow rate is still sufficient for bringing the fluid to saturation before entering the tube bundle.
Pressure drop is the parameter that is mostly affected by the DC configuration variations. The superficial roughness adopted for the distributed pressure drop is 4 × 10−5 m. The adoption of one (or two) DC(s) led to the necessity of collapsing the annular DC and its related junction areas into one (or two). As a result, pressure loss coefficients and hydraulic diameters have been modified (see Table 3 and Figure 4).
Stating that it is possible to conclude that the configuration with one external DCs (Figure 5) is a suitable choice for the OTSG mock-up foreseen for STEAM. In fact, assuring the removal of the required power, with respect to the full-size reference OTSG configuration, it:
  • introduces low-pressure drop distortions;
  • avoids parallel channels instability (which can occur in the two external-downcomer configurations);
  • eliminates the problem related to the manufacturing of an integrated annular DC.
Table 4 summarizes the OTSG geometrical data of TMI, BZ, scaled and optimized STEAM. After the selection of the reference DC configuration, further optimizations have been implemented without introducing modifications to the primary side tube geometry (i.e., tube thickness, diameter, arrangement and pitch). In particular:
  • according to the scaling procedure, the primary side tubes should be 35. Since the corresponding bundle configuration would be made up of uncompleted ranks, 37 tubes have been adopted in order to reduce the side effect: primary side flow area is increased and the fluid velocity is consequently decreased, affecting the heat transfer coefficient. However, the negative effect of the flow area increment is negligible with respect to the positive effect linked to the heat exchange area increment;
  • in order to reduce the by-pass and to uniform the temperature of the fluid exiting from different sub-channels, the shell has been hexagonally shaped, preserving the scaled riser free flow area, as shown in Figure 6.
In Figure 7 the temperature axial profile of BZ [10] and STEAM OTSG are shown: the feedwater temperature inside the downcomer steeply rises thanks to the recirculation pre-heating, reaching saturation conditions. Saturated boiling starts in the fluid flowing upwards in the riser until a single phase (superheating zone) is reached: the fluid temperature starts to increase, remaining constant inside the steam downcomer, where the heat transfer coefficient is almost negligible. The primary side temperature profile is flatter in the upper part of the OTSG because of the small heat transfer coefficient of the steam secondary side, while the lower part of the profile is steeper due to the high saturated boiling heat transfer coefficient.
The secondary side heat transfer coefficient in the riser is shown in Figure 8. Starting from the riser inlet, the nucleated boiling region is characterized by turbulences resulting from the bubble formation that enhances the heat transfer coefficient, until dry-out occurs when a blanket of saturated steam forms on the tube’s internal surface. Film boiling, characterized by a low heat transfer coefficient, starts and lasts until 100% steam quality is reached. After the end of the two-phase region, the superheating region starts, where the heat transfer coefficient is lower due to the low vapor density.
In Figure 7 and Figure 8, the main effect of the optimization process can be detected: as a result of the primary side tube number increase, dry-out occurs at a lower height in STEAM with respect to BZ OTSG, and therefore, also the vapor temperature starts to increase at a lower height.

4. CFD Analyses on the OTSG Tube Support Plate

System thermal hydraulic codes such as RELAP code are not reliable in the prediction of local pressure losses such as flow distribution in manifolds or sudden flow area changes. To overcome this issue a CFD analysis with Ansys CFX 2022 [17] code has been performed in order to hydraulically characterize the Tube Supporting Plate (TSP), reported in Figure 9, to assess the concentrated pressure drops at different mass flow rates (Re number). The ratio between TSP broached area and the riser free flow area is 0.01.
The developed CFD model includes only the fluid part and it is based on the same geometrical dimensions of the RELAP5 input, preserving the hexagon dimension, the grid measures, the PS tube diameter and the pitch. The 3D geometry, reported in Figure 10, consists of:
  • an upstream zone: a tube bundle region whose length is equal to 57 hydraulic diameters in order to have fully developed flow conditions at the grid;
  • the tube support plate;
  • a downstream zone: a tube bundle region whose length is equal to 25 hydraulic diameters in order to take into account the flow recirculation downstream the grid in the simulations.
Thanks to the symmetry of the pipe triangular lattice, only 1/6 of the geometry has been modeled, this solution grants a reduction of the computational resources for the simulations.
The input mesh (Figure 11) is fully structured both in the upstream/downstream regions and in the TSP grid (Figure 6). The average mesh size is 0.3 mm in the upstream/downstream regions and 0.2 mm inside the TSP holes. No node inflation was set on the walls, the water viscous sublayer is resolved with wall functions. The total number of elements is 9.97 million while the total number of nodes is 10.32 million.
Several calculations have been performed in order to characterize the grid pressure drops and the relative loss coefficient at different flow conditions. Isothermal simulations with single-phase fluid in saturation conditions (liquid or vapor) have been set adopting variable mass flow (from 1% to 100% of the nominal value) corresponding to a Reynolds number ranging from 300 to 1.5 × 105. Single-phase fluid simulations were performed instead of the two-phase ones, due to the well-known limitation of the current CFD codes in the reliable (validated) prediction of two-phase flow regimes. To overcome this issue, the Re range of the CFD simulation was widely expanded if compared to the nominal operating conditions in order to support the RELAP5 code, bordering all the possible Re flow regimes of the liquid and vapor phases in the OTSG. A detailed overview of the test conditions is reported in Table 5.
The boundary conditions set in the input model are:
  • a mass flow rate at the inlet surface (1/6 of the nominal value), see mfrCFD in Table 5;
  • an average relative pressure of 0 Pa at the outlet surface;
  • a free slip boundary condition (zero friction) on the side walls due to the symmetry constraint of the model.
Water and steam properties at saturated conditions (6.41 MPa, 279.93 °C) were calculated from [18] and implemented in the CFX code.
The turbulence model set in the simulations is the SST k-ω developed by Menter [19] for the turbulent and transition flow regime while a laminar flow model is set for the laminar regime. The simulations performed are steady-state RANS followed by a small transient run (CFL ≈ 1) of 3 s total time to reduce and stabilize all the RMS residuals to a value of 10 × 10−5. Total pressure drops across the model and velocity components on two monitor points upstream and downstream of the TSP were also monitored during the simulations.
Thanks to the Upgraded Cheng and Todreas (UCT) pressure drop correlation [20] for bare rod bundles, laminar and turbulent Re number limits were calculated. The maximum Re number for the laminar region is 1532 while the minimum Re for the turbulent regime is 19,055. It must be highlighted that the transition flow range predicted by the correlation is wider than the one implemented in RELAP5/Mod3.3 [9]. Four cases are in the laminar flow regime, four cases are in the transition regime and five cases are in the fully turbulent regime.
The axial pressure profile of a general test case (Figure 12) shows: a linear gradient from the inlet to the TSP due to the distributed pressure drop in the tube bundle, a step pressure drop and downstream pressure recovery due to the localized pressure drop of the TSP followed by the liner pressure trend of the downstream tube bundle.
To assess the reliability of the model and mesh developed, the pressure gradients in the tube bundle were compared with the analytical correlation [20] for all the cases simulated. The accuracy of the Upgraded Cheng and Todreas (UCT) pressure drop correlation for bare rod bundles is about ±10% for all the flow regimes [21], as reported in Table 6 the discrepancy of the CFD results is always lower than 7% for all the cases confirming the reliability of the CFD results.
Figure 13 shows in semi-logarithmic scale the TSP local pressure loss coefficient (Kgrid) against the Re number. The parameter Kgrid is defined as:
K g r i d = Δ p g r i d 1 2 ρ v 2   ,
where Δpgrid is the concentrated pressure loss due to the TSP grid and highlighted in Figure 12, ρ is the fluid density while v is the average mainstream velocity of the fluid in the tube bundle upstream of the TSP.
The general trend is similar to the Darcy friction factor coefficient with an almost linear trend in the laminar region and a power law trend in the transition/turbulent region. In the same figure is also reported (in light blue) the range of the average Re near the TSPs coming from the steady-state RELAP5 simulations.

5. Thermo-Mechanical Design of the STEAM OTSG Tubesheet

The STEAM OTSG is a non-nuclear equipment and falls into the PED hazard Category IV. The PED does not prescribe a specific standard for design; therefore, the analyses have been performed referring to the well-known ASME Boiler and Pressure Vessel Code (B&PVC). The pressure vessel (i.e., the shell) is assumed to be constructed from an 8-inch Schedule 160 carbon steel pipe and the tubesheet is considered to be integrated with the shell and channels (Figure 14). Future design activities will explore a more convenient flanged design. Concerning the internals of the STEAM OTSG mock-up, the TSPs are 1½ inches in thickness, as in TMI OTSG. A 1/8-inch-thick hexagonal shroud is placed around the tube bundle, forming the secondary-side flow channel.
ASME SA106 grade B carbon steel is commonly used in the construction of high-temperature oil and gas equipment, boilers, etc., and thus was assumed as the main structural material, due to its good resistance to high temperatures, low price, and good weldability. The thickness selected in any case far exceeds what would be required to withstand pressure load, but it was increased to consider possible unreinforced penetrations for measurement equipment, ports, centering pins, etc. The tube material is Inconel® Alloy 690 (UNS N06690). The allowable stress calculation procedure provided by the PED may lead to limits different from those taken from ASME B&PVC Section II-D. However, possible changes in material choice will be addressed in more detailed stages of the design. The tubesheet was preliminarily dimensioned according to the iterative methodology suggested by ASME BPVC.VIII.1 Part. UHX-13. Therefore, seven loading cases were considered: three design conditions that do not include thermal stresses and four operating conditions that do also include the thermal stresses. The load cases are summarized in Table 7.
The tubes were assumed to be fully hydraulically expanded into the tubesheet holes and then welded primary side. Corroded conditions were not considered.
Eventually, the thickness of the tubesheet was set to 4. The results are shown in Table 8 and Table 9.
As one can see, the stresses are everywhere far lower than the allowable limits, except in operating conditions when the compression stress in the tubes due to the thermal gradient would be more than allowed. This is a well-known issue that affects this kind of steam generator; therefore, to withstand the thermal loads, the tubes shall be pretensioned before mounting (e.g., once welded to the one tubesheet, they may be heated up and then welded to the other tubesheet). A preliminary Finite Element Method (FEM) steady-state thermo-mechanical analysis was conducted with ANSYS® Mechanical 2021 R2 to validate ASME design-by-formulae results. A 90° sector of the upper head was modeled (Figure 15).
The OTSG was considered perfectly insulated. Equilibrium temperatures were assigned to fluid and steam domains. The results (Figure 16) were then imported into ANSYS Mechanical.
For the sake of conciseness, just some results related to the normal operating conditions are summarised in Figure 17 and Table 10.
The results obtained from FEA are close to ASME previsions, although, as mentioned, the design of the OTSG shall be optimized in more detailed phases of the design.

6. Conclusions

The present paper describes the outcomes of the preliminary design phase of the DEMO OTSG mock-up to be installed in the STEAM facility, which will be built at the ENEA Brasimone Research Centre. The infrastructure is conceived to validate the WCLL DEMO BoP water coolant systems through a series of steady-state and transient experiments, aiming at demonstrating the capability of the OTSG to follow the plasma-induced load variations.
The first part of the activity focused on the realization of a RELAP5/Mod3.3 model to be used for code validation through the reproduction of the TMI OTSG. An analytical methodology has been set up in order to perform the BZ OTSG sizing, defining the active length on the basis of the power requirement. The procedure leads to a reduction in the tube length from 17 m of the TMI OTSG to 13 m. The obtained geometry can be considered the reference configuration to which apply a 1:1 in length scaling procedure for the STEAM OTSG through the adoption of a scaling factor calculated as powers ratio.
The constant “power to volume” scaling to switch from BZ OTSG to STEAM OTSG does not affect the parameter stability nor introduce major TH distortions. However, keeping the same layout of the BZ OTSG, the obtained configuration is characterized by a downcomer gap thickness of 2 cm, which is unfeasible because of manufacturing tolerances of coaxial pipes and determines remarkable difficulties in the instrumentation installation in the annular region. Two different solutions have been investigated with one or two external downcomers without modifying the component total flow area but removing the thermal coupling between ascendant and descendant regions. RELAP5/Mod3.3 comparison of the different constructive options shows that heat losses to the environment in percentage increases in decreasing power and in realizing external DC(s). Pressure losses are also influenced by the configuration variation since the necessity of collapsing the annular DC area and its related junctions into one (or two) modifies the correspondent pressure loss coefficients and hydraulic diameter. The solution with one external downcomer has been selected as a reference layout for the OTSG mock-up to be tested in the dedicated facility STEAM since it is easier to realize and does not introduce relevant distortions nor determine flow instabilities.
Further improvements have been adopted for optimizing the obtained configuration, such as increasing the scaled number of PS tubes in order to complete the ranks and adopting a hexagonally shaped riser in order to reduce the side effect. As a result, the final mock-up is characterized by a higher exchange area with respect to the required one determining anticipation of the dry-out condition.
CFD analyses have been performed in order to hydraulically characterize the TSP in order to find a Reynolds-dependent curve of the correspondent loss coefficient, to be implemented in RELAP5 code. Finally, FEM analyses have been carried out in order to size the tubesheets of the mock-up.

Author Contributions

Conceptualization, A.V., P.L., A.D.N. and M.E.; methodology, A.V., P.L. and A.D.N.; software, A.V., F.G., C.C., R.M. and A.T. (Andrea Tarallo); validation, A.V., P.L. and A.D.N.; formal analysis, A.V., P.L. and A.D.N.; investigation, A.V., P.L., A.D.N., M.E., F.G., R.M. and C.C.; resources, A.D.N.; data curation, A.V. and P.L.; writing—original draft preparation, A.V., P.L. and R.M.; writing—review and editing, A.V., P.L., M.E., F.G., C.C., A.T. (Amelia Tincani) and A.D.N.; visualization, A.V. and P.L.; supervision, A.D.N., M.E. and F.G.; project administration, A.D.N. and M.E.; funding acquisition, A.D.N. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the European Union via the Euratom Research and Training Programme, grant number 101052200.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not Applicable.

Acknowledgments

This work has been carried out within the framework of the EUROfusion Consortium, funded by the European Union via the Euratom Research and Training Programme (Grant Agreement No 101052200—EUROfusion). Views and opinions expressed are, however, those of the author(s) only and do not necessarily reflect those of the European Union or the European Commission. Neither the European Union nor the European Commission can be held responsible for them.

Conflicts of Interest

The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

Nomenclature

APAspirator Port
BBBreeding Blanket
BoPBalance of Plant
BZBreeding Zone
B&WBabcock & Wilcox
CFDComputational Fluid Dynamics
DCDownComer
DEMODEMOnstration Power Plant
ENEAItalian National Agency for New Technologies, Energy and Sustainable Economic Development
FEMFinite Element Method
HSHeat Structure
HYDRAHYDRAulic
ITERInternational Thermonuclear Experimental Reactor
MFRMass Flow Rate
N.C.Not Considered
O.D.Outer Diameter
OTSGOnce Trough Steam Generator
PCSPower Conversion System
PHTSPrimary Heat Transfer System
PSPrimary Side
PWRPressurized Water Reactor
R&DResearch & Development
SGSteam Generator
SJSingle Junction
SSSecondary Side
T-HThermal-Hydraulic
T-MThermo-Mechanical
TMIThree Miles Island
TSPTuve Support Plate
UCTUpgraded Cheng and Todreas
WCLLWater Cooled Lithium Lead
WPWater Port

References

  1. Federici, G.; Boccaccini, L.; Cismondi, F.; Gasparotto, M.; Poitevin, Y.; Ricapito, I. An overview of the EU breeding blanket design strategy as an integral part of the DEMO design effort. Fusion Eng. Des. 2019, 141, 30–42. [Google Scholar] [CrossRef]
  2. Muratov, V.P.; Saksagansky, G.L.; Filatov, O.G. ITER—International Thermonuclear Experimental Reactor. In Fundamentals of Magnetic Thermonuclear Reactor Design; Woodhead Publishing Series in Energy: Sawston, UK, 2018; pp. 39–67. [Google Scholar] [CrossRef]
  3. Barucca, L.; Bubelis, E.; Ciattaglia, S.; D’Alessandro, A.; Del Nevo, A.; Giannetti, F.; Hering, W.; Lorusso, P.; Martelli, E.; Moscato, I.; et al. Pre-conceptual design of EU DEMO balance of plant systems: Objectives and challenges. Fusion Eng. Des. 2021, 169, 112504. [Google Scholar] [CrossRef]
  4. Available online: https://www.euro-fusion.org/ (accessed on 10 May 2022).
  5. Tarantino, M.; Martelli, D.; Del Nevo, A.; Utili, M.; Di Piazza, I.; Eboli, M.; Diamanti, D.; Tincani, A.; Miccichè, G.; Bernardi, D.; et al. Fusion technologies development at ENEA Brasimone Research Centre: Status and perspectives. Fusion Eng. Des. 2020, 160, 112008. [Google Scholar] [CrossRef]
  6. Barucca, L.; Hering, W.; Martin, S.P.; Bubelis, E.; Del Nevo, A.; Di Prinzio, M.; Caramello, M.; D’Alessandro, A.; Tarallo, A.; Vallone, E.; et al. Maturation of critical technologies for the DEMO balance of plant systems. Fusion Eng. Des. 2022, 179, 113096. [Google Scholar] [CrossRef]
  7. Moscato, I.; Barucca, L.; Bubelis, E.; Caruso, G.; Ciattaglia, S.; Ciurluini, C.; Del Nevo, A.; Di Maio, P.A.; Giannetti, F.; Hering, W.; et al. Tokamak cooling systems and power conversion system options. Fusion Eng. Des. 2022, 178, 113093. [Google Scholar] [CrossRef]
  8. Lorusso, P.; Del Nevo, A.; Arena, P.; Eboli, M.; Marinari, R.; Tincani, A.; Agostini, P.; Badodi, N.; Cammi, A.; Del Moro, T.; et al. STEAM: A novel experimental infrastructure for the development of the DEMO BoP water coolant technology. In Proceedings of the 19th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-19), Brussels, Belgium, 6–11 March 2022. [Google Scholar]
  9. Information Systems Laboratories. RELAP5/Mod3.3 Code Manual Volume I: Code Structure, System Models, and Solution Methods; Nuclear Safety Analysis Division, Information Systems Laboratories: Idaho Falls, ID, USA, 2001; Volume 1. [Google Scholar]
  10. Ciurluini, C.; Vannoni, A.; Del Moro, T.; Lorusso, P.; Tincani, A.; Del Nevo, A.; Barucca, L.; Giannetti, F. Thermal-hydraulic assessment of Once-Through Steam Generators for EU-DEMO WCLL Breeding Blanket primary cooling system application. Fusion Eng. Des. 2023, 193, 113688. [Google Scholar] [CrossRef]
  11. Available online: https://www.babcock.com/ (accessed on 20 April 2022).
  12. The Babcock & Wilcox Company. Steam, Its Generation and Use, 41st ed.; Kitto, J.B., Stultz, S.C., Eds.; The Babcock & Wilcox Company: Akron, OH, USA, 2005. [Google Scholar]
  13. USNRC HRTD. Pressurized Water Reactor B&W Technology, Crosstraining Course Manual, Chapter 2.4, Once-through Steam Generator; USNRC HRTD: Washington DC, USA, 2011. [Google Scholar]
  14. Ivanov, K.N.; Beam, T.M.; Baratta, A.J.; Irani, A.; Trikouros, N. Pressurised Water Reactor Main Steam Line Break (Mslb) Benchmark; Volume I: Final Specifications; Nuclear Energy Agency: Paris, France, 1999. [Google Scholar]
  15. Spontarelli, A.M. CFD Analysis of the Aspirator Region in a B&W Enhanced Once-Through Steam Generator. Master’s Thesis, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA, 7 May 2013. [Google Scholar]
  16. Tincani, A.; Ciurluini, C.; Del Nevo, A.; Giannetti, F.; Tarallo, A.; Tripodo, C.; Cammi, A.; Vannoni, A.; Eboli, M.; Del Moro, T.; et al. Conceptual Design of the Steam Generators for the EU DEMO WCLL Reactor. Energies 2023, 16, 2601. [Google Scholar] [CrossRef]
  17. Ansys Inc. Ansys CFX-Solver Theory Guide; Release 2022 R1; Ansys Inc.: Canonsburg, PA, USA, 2022. [Google Scholar]
  18. Water TH Properties. Available online: http://www.peacesoftware.de/einigewerte/wasser_dampf_e.html (accessed on 8 June 2022).
  19. Menter, F.R. Two-equation eddy-viscosity turbulence models for engineering applications. AIAA J. 1994, 32, 1598–1605. [Google Scholar] [CrossRef]
  20. Chen, S.K.; Chen, Y.M.; Todreas, N.E. The upgraded Cheng and Todreas correlation for pressure drop in hexagonal wire-wrapped rod bundles. Nucl. Eng. Des. 2018, 335, 356–373. [Google Scholar] [CrossRef]
  21. Chen, S.K.; Chen, Y.M.; Todreas, N.E. A note on the accuracy of the upgraded Cheng and Todreas correlation for predicting pressure drop in hexagonal bare rod bundles. Appl. Therm. Eng. 2019, 161, 114193. [Google Scholar] [CrossRef]
Figure 1. OTSG reference configuration (left) and schematic flow paths (right).
Figure 1. OTSG reference configuration (left) and schematic flow paths (right).
Energies 16 03729 g001
Figure 2. RELAP5/Mod3.3 1-D nodalization of the TMI OTSG.
Figure 2. RELAP5/Mod3.3 1-D nodalization of the TMI OTSG.
Energies 16 03729 g002
Figure 3. Analyzed configuration for the STEAM OTSG secondary side: annular coaxial DC (a), one external DC pipe (b), two external DC pipes (c).
Figure 3. Analyzed configuration for the STEAM OTSG secondary side: annular coaxial DC (a), one external DC pipe (b), two external DC pipes (c).
Energies 16 03729 g003
Figure 4. Pressure drops relevant points reported in Table 3 along the OTSG.
Figure 4. Pressure drops relevant points reported in Table 3 along the OTSG.
Energies 16 03729 g004
Figure 5. STEAM OTSG 3D CAD.
Figure 5. STEAM OTSG 3D CAD.
Energies 16 03729 g005
Figure 6. Hexagonally shaped riser with a detail of the tube support plate (TSP).
Figure 6. Hexagonally shaped riser with a detail of the tube support plate (TSP).
Energies 16 03729 g006
Figure 7. Axial temperature profile of BZ and STEAM OTSG.
Figure 7. Axial temperature profile of BZ and STEAM OTSG.
Energies 16 03729 g007
Figure 8. Axial profile of the heat transfer coefficient of BZ and STEAM OTSG.
Figure 8. Axial profile of the heat transfer coefficient of BZ and STEAM OTSG.
Energies 16 03729 g008
Figure 9. Three-dimensional model of the tube supporting plate.
Figure 9. Three-dimensional model of the tube supporting plate.
Energies 16 03729 g009
Figure 10. Sketch of the 3d geometry developed highlighting the three main regions of the model.
Figure 10. Sketch of the 3d geometry developed highlighting the three main regions of the model.
Energies 16 03729 g010
Figure 11. Axial sketch of the fully structured mesh developed (left) and highlight of the calculation grid on a cross-section plane (right).
Figure 11. Axial sketch of the fully structured mesh developed (left) and highlight of the calculation grid on a cross-section plane (right).
Energies 16 03729 g011
Figure 12. Axial pressure profile for a generic test case (100% liquid mass flow rate).
Figure 12. Axial pressure profile for a generic test case (100% liquid mass flow rate).
Energies 16 03729 g012
Figure 13. Plot of the TSP local pressure drop coefficient against the bundle Re number, In the plot are highlighted the flow regimes and the Re operative range near the grids according to RELAP results.
Figure 13. Plot of the TSP local pressure drop coefficient against the bundle Re number, In the plot are highlighted the flow regimes and the Re operative range near the grids according to RELAP results.
Energies 16 03729 g013
Figure 14. Upper (left) and lower (right) tubesheets.
Figure 14. Upper (left) and lower (right) tubesheets.
Energies 16 03729 g014
Figure 15. Solid model for FE thermal analyses.
Figure 15. Solid model for FE thermal analyses.
Energies 16 03729 g015
Figure 16. Thermomechanical analysis.
Figure 16. Thermomechanical analysis.
Energies 16 03729 g016
Figure 17. Von-Mises stresses and SCLs are used for stress linearization (normal operation loading case).
Figure 17. Von-Mises stresses and SCLs are used for stress linearization (normal operation loading case).
Energies 16 03729 g017
Table 1. TMI steady state qualification.
Table 1. TMI steady state qualification.
ParameterUnitRef [15]R5Error
PowerMW13861335.273%
Tinlet,PS (BC)°C318318.000 °C
Toutlet,PS°C291291.040.04 °C
Tinlet,SS (BC)°C2382380 °C
Toutlet,SS°C299305.116.11 °C
pinlet,PSMPa15.17 [15]15.02−1%
poutlet,PSMPa14.9614.89−0.5%
priser bottom,SSMPaN/A6.52-
poutlet,SSMPa6.416.410%
mfrPS (BC)kg/s8801.18801.10%
mfrSS *kg/s761.59717.80−5.7%
mfrreckg/sN/A111.1-
* Feedwater mass flow is regulated in order to exchange the amount of power that guarantees the correct primary side outlet temperature, which is considered to be fixed.
Table 2. Comparison of the T/H results of the different configurations simulated.
Table 2. Comparison of the T/H results of the different configurations simulated.
ParameterBZSTEAM
Annular DCOne DCTwo DCs
Power [MW]581.53.013.023.01
Riser Level [m]1.81.751.861.86
DC Level [m]4.03.943.503.49
Tout,PHTS [°C]295.0294.87294.78294.75
ΓPHTS [kg/s]3010.615.55215.55215.552
ΓFW [kg/s]316.21.5671.5671.567
Γrec [kg/s]42.00.240.220.22
ΓrecFW14151414
Heat losses14.00.232.172.96
Ploss/P0.02%0.08%0.72%0.98%
Void F. (DC last volume)0.340.027284.0 × 10−61.0 × 10−5
Table 3. Comparison between pressure drops of the analyzed configurations.
Table 3. Comparison between pressure drops of the analyzed configurations.
Pressure Drops [kPa]BZSTEAM
Annular DCOne DCTwo DCs
PHTS * (from A to B)81.94118.26118.21118.23
DC (from 1 to 2)−31.85−31.69−30.97−30.17
Orifice plate (from 2 to 3)2.262.622.152.16
WPs and low riser (from 3 to 4)28.0928.4528.3227.69
High riser (from 4 to 5)4.0416.7416.6617.18
Steam ports (from 5 to 6)16.191.013.323.36
Steam DC (from 6 to 7)0.619.770.621.62
Steam nozzle (from 7 to 8)23.891.791.681.83
Total SS (from 1 to 8)43.2228.6921.7823.67
Aspirator port (from 4 to 9)1.400.620.510.31
* Primary side total pressure drops are calculated by subtracting the static contribution to the total pressure drop.
Table 4. TMI, BZ, STEAM scaled and optimized configuration geometrical data.
Table 4. TMI, BZ, STEAM scaled and optimized configuration geometrical data.
ParameterTMIBZSTEAM (Scaled)STEAM (Optim.)
Tubes number [-]15,50069433537
Active Length [m]16.26912.9812.9812.98
Tubes O.D. [mm]15.87515.87515.87515.875
Total PHTS Area [m2]2.43671.090.00550.0058
Riser flow Area [m2]4.0161.790.0090.009
DC flow Area [m2]2.1670.970.00490.0049
Rec. Area [m2]0.960.510.00260.0026
(p/D)1.41.4 1.41.4
LatticeTriangular TriangularTriangularTriangular
Shell I.D. [m]3.52.3640.170.1554
(hexagon diameter)
Table 5. CFD numerical test matrix.
Table 5. CFD numerical test matrix.
Phase m ˙ ReRegimemfrCFDv
[-][%][-][-][kg/s][m/s]
liq1003.0 × 104Turb0.2720.24
liq501.5 × 104Tran0.1360.119
liq257.5 × 103Tran0.0680.059
liq103.0 × 103Tran0.0270.023
liq61.8 × 103Tran0.0160.014
liq41.2 × 103Lam0.0110.009
liq39.0 × 102Lam0.0080.007
liq13.0 × 102Lam0.0030.002
vap1001.5 × 105Turb0.2725.41
vap507.5 × 104Turb0.1362.704
vap253.7 × 104Turb0.0681.352
vap172.5 × 104Turb0.0450.9
vap11.5 × 103Lam0.0030.054
Table 6. Relative error of the bundle pressure gradient predicted by the CFD simulations against the analytical UCT correlation.
Table 6. Relative error of the bundle pressure gradient predicted by the CFD simulations against the analytical UCT correlation.
ReRegime ( d p d l ) U C T ( d p d l ) C F D Err = | U C T C F D | U C T
[-][-][Pa/m][Pa/m][-]
3.0 × 104Laminar30.5631.880.04
1.5 × 104Laminar8.839.520.07
7.5 × 103Laminar2.792.930.05
3.0 × 103Laminar0.660.670.01
1.8 × 103Transition0.310.300.02
1.2 × 103Transition0.160.170.05
9.0 × 102Transition0.120.120.02
3.0 × 102Transition0.040.040.05
1.5 × 105Turbulent518.05499.820.04
7.5 × 104Turbulent146.72144.930.01
3.7 × 104Turbulent41.5642.650.03
2.5 × 104Turbulent19.8320.970.05
1.5 × 103Turbulent0.180.190.07
Table 7. Loading cases for tubesheet preliminary sizing.
Table 7. Loading cases for tubesheet preliminary sizing.
CasePSPtTsTt
MPaMPa°C°C
1017.8N.C.N.C.
27.40N.C.N.C.
37.417.8N.C.N.C.
4015.5287311
56.40287311
66.415.5287311
700287311
Table 8. Results for design loading cases.
Table 8. Results for design loading cases.
LimitUnitCase 1Case 2Case 3
Tubesheet Bending stress141.8MPa12.39.112.0
Tube compressive load63.5MPa35.814.621.2
Shell membrane stress94.5MPa2.810.112.7
Total shell axial stress141.8MPa5.441.040.6
Total channel axial stress 141.8MPa70.26.676.3
Table 9. Results for operating loading cases.
Table 9. Results for operating loading cases.
LimitUnitCase 4Case 5Case 6Case 7
Tubesheet Bending stress283.5MPa6.513.13.213.7
Tube compressive load63.4MPa87.3131.3100.1118.4
Shell membrane stress283.5MPa16.923.425.714.5
Total shell axial stress283.5MPa24.960.960.624.7
Total channel axial stress 283.5MPa50.94.756.310.2
Table 10. FEA results for normal operation loading cases.
Table 10. FEA results for normal operation loading cases.
LIMITUnitASMEFEA
Max Tubesheet Bending stress283.5MPa3.26.01
Tube compressive load63.4MPa100.195.8
Shell membrane stress283.5MPa25.729.4
Total shell axial stress283.5MPa60.647.6
Total channel axial stress 283.5MPa56.363.0
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Vannoni, A.; Lorusso, P.; Eboli, M.; Giannetti, F.; Ciurluini, C.; Tincani, A.; Marinari, R.; Tarallo, A.; Del Nevo, A. Development of a Steam Generator Mock-Up for EU DEMO Fusion Reactor: Conceptual Design and Code Assessment. Energies 2023, 16, 3729. https://doi.org/10.3390/en16093729

AMA Style

Vannoni A, Lorusso P, Eboli M, Giannetti F, Ciurluini C, Tincani A, Marinari R, Tarallo A, Del Nevo A. Development of a Steam Generator Mock-Up for EU DEMO Fusion Reactor: Conceptual Design and Code Assessment. Energies. 2023; 16(9):3729. https://doi.org/10.3390/en16093729

Chicago/Turabian Style

Vannoni, Alessandra, Pierdomenico Lorusso, Marica Eboli, Fabio Giannetti, Cristiano Ciurluini, Amelia Tincani, Ranieri Marinari, Andrea Tarallo, and Alessandro Del Nevo. 2023. "Development of a Steam Generator Mock-Up for EU DEMO Fusion Reactor: Conceptual Design and Code Assessment" Energies 16, no. 9: 3729. https://doi.org/10.3390/en16093729

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop