Next Article in Journal
Integration of Portable Sedimentary Microbial Fuel Cells in Autonomous Underwater Vehicles
Next Article in Special Issue
Independent Upper- and Lower-Arm Switching Scheme Based on Reference Current Polarity for Three-Level NPC Inverters
Previous Article in Journal
Low-Cost Thermal Camera-Based Counting Occupancy Meter Facilitating Energy Saving in Smart Buildings
Previous Article in Special Issue
Influence of the Semiconductor Devices Cooling Conditions on Characteristics of Selected DC–DC Converters
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Sensorless Control of Voltage Peaks in Class-E Single-Ended Resonant Inverter for Induction Heating Rice Cooker

1
R&D Center, Willings Co., Ltd., Yongin-si 17037, Gyeonggi-do, Korea
2
Infineon Technologies Austria AG, 9500 Villach, Austria
3
Department of Mechatronics Engineering, Hanyang University, Seongdong-gu, Seoul 04763, Korea
4
Institute of Industrial Electronics and Electrical Engineering, Riga Technical University, LV-1658 Riga, Latvia
5
Department of Electrical Engineering, Yuhan University, Bucheon 14780, Gyeonggi-do, Korea
6
Department of Information and Communication Engineering, Yuhan University, Bucheon 14780, Gyeonggi-do, Korea
*
Author to whom correspondence should be addressed.
Energies 2021, 14(15), 4545; https://doi.org/10.3390/en14154545
Submission received: 24 June 2021 / Revised: 16 July 2021 / Accepted: 21 July 2021 / Published: 28 July 2021
(This article belongs to the Special Issue Optimal Design of Power Converters)

Abstract

:
Single-ended (SE) resonant inverters are widely used as power converters for high-pressure rice cooker induction, with 1200 V insulated-gate bipolar transistors (IGBTs) being used as switching devices for kW-class products. When voltage fluctuations occur at the input stage of an SE resonant inverter, the resonant voltage applied to the IGBT can be directly affected, potentially exceeding the breakdown voltage of the IGBT, resulting in its failure. Consequently, the resonant voltage should be limited to below a safety threshold—hardware resonant voltage limiting methods are generally used to do so. This paper proposes a sensorless resonant voltage control method that limits the increase in the resonant voltage caused by overvoltage or supply voltage fluctuations. By calculating and predicting the resonance voltage through the analysis of the resonance circuit, the resonance voltage is controlled not to exceed the breakdown voltage of the IGBT. The experimental results of a 1.35 kW SE resonant inverter for a high-pressure induction heating rice cooker were used to verify the validity of the proposed sensorless resonant voltage limiting method.

1. Introduction

Induction heating—that is, the conversion of electrical energy into thermal energy using electromagnetic induction generated in conductive materials in alternating magnetic fields—has been used in the melting and heat treatment of metals in industry for many years [1]. In particular, owing to the rapid progress of semiconductor devices and control systems in the 1980s, various high-frequency resonant inverter systems [2] have been developed as induction heating power sources. Their use has been increasing in industrial applications as well as in domestic cookers [3].
Inverters for domestic induction heating products, such as electric or induction rice cookers, usually have a capacity of 1–2 kW, using simple, low-cost, class-E single-ended (SE) resonant inverters [4]. Such inverters require a semiconductor switch with a high breakdown voltage—deemed to be necessary because a capacitor is connected in parallel with a working coil to obtain voltage resonance, which is applied to a switch in series with a DC link capacitor [5]. Consequently, an insulated-gate bipolar transistor (IGBT) with a high breakdown voltage of 1200 V or more is typically used as the switching element [6,7].
For the stable operation of a resonant inverter, it is necessary to stabilize the DC link voltage. Moreover, the power factor of the power input should be considered, making it necessary to apply a DC/DC converter with a power factor correction function and a large capacitor in the DC link stage [8,9].
However, in the case of an SE resonant inverter, only a choke coil and a small capacitor to bypass a resonant current are applied to the bridge circuit DC stage—a method of using the high-input power factor characteristics of high-frequency switching on the inverter side [10,11], and the theoretical analysis of the equivalent circuit was presented [11,12]—simplifying the configuration circuit and reducing manufacturing costs. However, its small capacity makes it vulnerable to changes in the input voltage and distortion. Therefore, when the input power voltage fluctuates, the DC link voltage can be directly affected—that is, the resonant voltage and the voltage across the switching element may suddenly increase, destroying the switching element [13,14,15]. Consequently, for stable operation of an SE resonant inverter, it is necessary to control or limit the resonant voltage.
An active clamped class-E (ACCE) inverter that clamps the resonant voltage has been proposed as a solution. Although the output power of the ACCE inverter is lower than that of existing class-E inverters, it has the advantage of protecting the switching element by reducing the resonance voltage of the switch [16,17].
A hybrid scheme has been proposed to overcome the shortcomings of ACCE inverters with reduced output power [18], a method that has the advantage of increasing the output power by using two circuits—that is, a class-E and an ACCE inverter. However, these hybrid-ACCE inverters have the disadvantage of being more expensive than conventional class-E inverters because of the addition of auxiliary switches and clamping capacitors. To solve this problem, an improved hybrid-ACCE inverter control scheme using pulse frequency modulation and eliminating auxiliary frequency switches and clamping capacitors has been proposed [19]. Here, the switching frequency is adjusted based on the input reference voltage: the switching frequency of the class-E inverter is divided into constant frequency and variable frequency regions, the voltage stress of the switch being controlled by the variable frequency. However, this also requires more switches than the class-E inverter, increasing its price. Moreover, control is complex, raising the possibility of malfunctions. A prediction model of an induction heating inverter was made and the power was controlled, but the resonance voltage was not controlled [20].
In a steady-state, operation for induction heating is sufficient for use with SE inverters as well. However, when instantaneous fluctuations and disturbances occur in the field, the SE inverter is greatly affected compared to inverters of other topologies. The authors have also proposed a resonant voltage limitation method using hardware [21] comprising one current sensing resistor, one analog comparator, one set/reset (SR) latch, and one AND-gate. It is simple hardware but more complex to implement than software.
When an oversized load is operated in a grid, fluctuations and disturbances in the input voltage are inevitably accompanied. In this case, the SE inverter is frequently stopped because of the protective operation to prevent damage to the IGBT. Additionally, the heating time is increased. Therefore, the resonant voltage must be controlled in an abnormal state rather than in a steady state.

2. Methodology: Single-Ended (SE) Resonant Inverter for Induction Heating Rice Cooker

Figure 1 shows a circuit diagram of an SE resonant inverter used for induction heating. This inverter can significantly reduce switching losses through a zero-voltage switching operation, while the voltage across the IGBT, Q, is high owing to the voltage resonance. The input stage consists of a bridge diode for rectification, a choke coil, and a DC link capacitor, Cdc. An equivalent inductor, Leq, and equivalent resistance, Req, for the working coil and cooking vessel are connected in series. A resonant capacitor, Cr, is connected in parallel with the working coil to form a resonant tank. In rice cookers, variations in the equivalent inductance and resistance are not significant as the rice cooking vessel is fixed within the cooker body with the working coil wound around it.

2.1. Operation Mode of the Equivalent Resonant Circuit

The operation of the resonant inverter is shown in Figure 2. In mode I, the resonant current of the previous mode flows through the anti-parallel diode of the switching element Q. Consequently, the voltage across the switching element, Q, is zero. The switching device is turned on during this period, and zero-voltage switching is performed. Mode II is an operational mode in which the switching element, Q, is turned on to receive power from the input while the current flows through the equivalent inductor, Leq, and equivalent resistor, Req. In Mode III, the switching element, Q, is turned off, and resonance starts between the equivalent inductor Leq and resonant capacitor Cr. In this case, neglecting the tail current of the IGBT used as a switching element can be considered to be zero-voltage turn-off switching. Mode IV is an operational mode in which the energy of the equivalent inductor, Leq, is accumulated in the resonant capacitor Cr and then transferred to the equivalent inductor Leq [22].
Figure 3 shows the theoretical voltage and current waveforms of each part of the circuit during operation.

2.2. Anlalysis of the Equivalent Resonant Circuit

Two equivalent circuits of the inverter exist, as shown in Figure 4: one for the on-state of the IGBT and another for the off-state [22].
When the IGBT, Q, is turned on, the current flows through the equivalent inductor Leq and equivalent resistance Req, as shown in Figure 4a. When the IGBT, Q, is turned off, the inductor energy is transferred to the capacitor by resonance, as shown in Figure 4b.
First, assuming that the DC link voltage, Vdc, is constant while the switching element, Q, is turned on, it is possible to compose the voltage equation of the equivalent circuit, as follows:
V d c = L e q d i L e q _ o n ( t ) d t + R e q i L e q _ o n ( t )
The inductor current, iLeq_on, can be derived from (1), which in the case of the on-state, can be represented as:
i L e q _ o n ( t ) = V d c R e q ( 1 e R e q L e q t )
When the IGBT, Q, is off, the current of equivalent inductor Leq continues flows as shown in Figure 4b. The voltage equation of the equivalent circuit can be expressed as:
1 C r i L e q _ o f f d t + L e q d d t i L e q _ o f f + R e q i L e q _ o f f = 0
When the IGBT, Q, is turned on, the inductor current, iLeq_off, can be represented as:
i L e q _ o f f ( t ) = A e α t cos ( ω t + θ )
where:
A = ( V d c ω L e q α I L e q P ω ) 2 + I L e q P 2
α = R e q 2 L e q
ω = 1 L e q C r ( R e q 2 L e q ) 2
and
θ = tan 1 ( α L e q I L e q P V d c ω L e q I L e q P )
Conversely, when the switching element, Q, is turned off, the resonance of the equivalent inductor, Leq, and resonant capacitor, Cr, starts; therefore, the resonant capacitor current iCr can be expressed as follows:
i C r _ o f f ( t ) = i L e q _ o f f ( t )
= A e α t cos ( ω t + θ )
Accordingly, the resonant capacitor voltage, vCr, can be represented as follows:
v C r ( t ) = 1 C r i C r ( t ) d t
= A C r e α t cos ( ω t + θ ) d t
As the maximum instant of the resonance voltage is a quarter of the resonance period, T, the value of the peak resonance voltage, VCrP, can be derived as follows:
V C r P = 1 C r 0 T 4 i C r ( t ) d t
= A C r 0 T 4 e α t cos ( ω t + θ ) d t
= A C r 1 ( α + ω ) 2 ( α + ω e α π 2 ω )
The voltage across the switching element vCE is the sum of the DC link voltage and resonant capacitor voltage. Thus, vCE can be given by:
v C E ( t ) = V d c v C r ( t )
Consequently, the maximum value, VCEM, that appears across the IGBT over the entire period of the source voltage, vS, can be given by:
V C E M = V S P V C r P
where VSP is the maximum value of the source voltage, vS.
As shown in (15), the maximum voltage, VCEM, is usually 1000 V or more because VCrP is negative, making it necessary to control the magnitude of the resonance voltage to prevent breakage of the IGBT.

2.3. Sensorless Control of Voltage Peaks by Resonant Voltage Estimation Using the Turn-On Duration of the IGBT

We can calculate the resonant peak voltage, VCrP, using (15). However, it is complex, and calculations using (15) can be a burden on the MCU.
As ω >> α, A and VCrP in (5) and (15) can be represented, respectively, as:
A I L e q P
V C r P A C r 1 ( α + ω )
Meanwhile, the peak current of the working coil is equal to the current at the turn-off instant of the IGBT. As the conduction period of the anti-parallel diode before the IGBT turns on is relatively short, it can be ignored. Consequently, the peak current of the working coil, ILeqP, can be obtained from the DC link voltage, Vdc, the equivalent inductance, Leq, and the turn-on duration of the switching element, ton, as follows:
I L e q P = V d c × t o n L e q
The peak resonant voltage can be given by:
V C r P V d c × t o n L e q C r ( α + ω )
It can be seen that (21) is simpler to calculate than (15). Substituting (21) into (17) yields:
V C E M V S P + V S P × t o n L e q C r ( α + ω )
The turn on time can be given by:
t o n = ( V C E M V S P ) L e q C r ( α + ω ) V S P
Typically, the SE converter controls the input power by measuring the input voltage and current, as it is easier to measure the low-frequency than the high-frequency AC of the output. With the input voltage and turn-on time, the resonant voltage can be controlled using (21) without any additional circuits, including a voltage sensor for the high-frequency resonant voltage. Consequently, the maximum voltage across the IGBT can be limited using (22).
The constants of the equivalent variables and switching frequency change slightly during operation, making it difficult to calculate the resonant peak voltage, VCrP, using (15). Consequently, we propose a simple estimation method to control the resonant voltage for the protection of the switching element from overvoltage damage.
Figure 5 shows the sequence for power control and resonance voltage control. MCU performs AD conversion at 100 us interrupt, which is the control cycle.
The ton is calculated every 50 ms by executing the PI controller. The toff is determined according to the working coil and vessel and is a fixed value. Therefore, the period of PWM becomes ton + toff, so the switching frequency slightly varies according to the amount of power. The maximum value of ton, ton(max), is calculated by Equation (23). VCEM is determined in consideration of the breakdown voltage of the IGBT. If the PWM ton is greater than a ton(max), the ton is limited to ton(max).

3. Results: Experimental Setup and Evaluation

Figure 6 shows the configuration of the SE resonant inverter of the 1.35 kW household induction rice cooker used in the experiment, an MC56F8002 being used as a controller in the experimental setup. Table 1 and Figure 7 show the parameters of the experimental setup and an image of the main printed circuit board (PCB), respectively.
First, waveforms of the voltage across the switching element, vCE, and the resonant current, iLeq, with a source voltage of 220 V, are shown in Figure 8. The maximum voltage across the switching element was measured to be 1016 V, approximately 75% of the IGBT ratings used in the experiment.
The experiment was conducted under fluctuations of the source voltage to verify the usefulness of the proposed resonant voltage estimation method, the source voltage fluctuations being induced by increasing it from 220 V to 260 V for 1 ms (using the 80° voltage phase).
The experimental results—using the single-ended (SE) resonant inverter shown in Figure 5 and Figure 6—under source voltage fluctuations, are shown in Figure 9. In these experiments, the source voltage was increased at the disturbance point, the reaction of the inverter being recorded.
The results of the conventional system without resonant-voltage limit-control under source voltage disturbance are shown in Figure 9a. These show that the inverter tripped owing to the IGBT overvoltage protection at the voltage disturbance point. In this case, the overvoltage level was 1270 V, the voltage safety margin being just 80 V for the 1350 V-rated IGBT.
Figure 9b shows the experimental results of the proposed sensorless method, the voltage across the IGBT being limited to a specific level. As a result, the inverter operated continuously without tripping. In this case, the control level of the resonant peak voltage was set to 900 V, the peak voltage across the IGBT being limited to 1210 V. Here, the voltage margin was 140 V, the peak voltage across the IGBT level being 90% of the IGBT rating. Consequently, it was confirmed that the proposed system could be operated stably and continuously without tripping under voltage disturbances.
Figure 10 shows the experimental results of a resonant voltage limitation method using the hardware proposed in [19]. The performance of the proposed sensorless method and that of the hardware method are the same as those shown in Figure 9 and Figure 10. The hardware comprises one current sensing resistor, one analog comparator, one SR latch, and one AND-gate, as shown in Figure 10b. It is simple, but more expensive, hardware. As most home appliances today use an MCU as a controller, it is desirable to have as few components as possible.

4. Discussion

The given results showed that the voltage across the switching element of the SE resonant inverter could be limited to a certain level or less using the proposed sensorless resonant voltage peak control. As a result, the inverter could be operated continuously without tripping. When the control level of the resonant peak voltage was set to 890 V, the peak voltage across the switching element was limited to 1200 V. This result indicates that the proposed method could provide stable control even under input voltage fluctuations and disturbances by limiting the high-voltage stress across the switching element. The system efficiency was 96.55% at full load and 88.13% at 40% load. While the input voltage is rising, it operates as hard switching, not ZVS. However, since the resonance voltage peak control is operated under abnormal, the efficiency is not affected.

5. Conclusions

In this paper, a sensorless resonance voltage estimation method is proposed to prevent the breakdown of IGBT in case of instantaneous fluctuation of input voltage and to enable continuous operation without protection operation. The validity of the proposed method was verified experimentally using an SE resonant inverter for a 1.35 kW induction heating household rice cooker.
The proposed method has the advantage to implement without additional hardware or high-frequency side voltage sensors in an SE inverter. Since resonant voltage estimation requires input voltage and turn-on time, it can be easily calculated even with a low-cost MCU. However, it is necessary to consider the change in circuit constant in actual application due to temperature rise.

Author Contributions

Conceptualization, Y.O. and J.Y.; methodology, Y.O. and J.Y.; software, J.K.; validation, W.O., I.G., and K.C. writing—original draft preparation, W.O. and K.C.; writing—review and editing, I.G., W.O., and K.C. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Dawson, F.; Jain, P. A comparison of load commutated inverter systems for induction heating and melting applications. IEEE Trans. Power Electron. 1991, 6, 430–441. [Google Scholar] [CrossRef]
  2. Bi, C.; Lu, H.; Jia, K.; Hu, J.; Li, H. A Novel Multiple-Frequency Resonant Inverter for Induction Heating Applications. IEEE Trans. Power Electron. 2016, 31, 8162–8171. [Google Scholar] [CrossRef]
  3. Kim, D.; So, J.; Kim, D. Study on Heating Performance Improvement of Practical Induction Heating Rice Cooker with Magnetic Flux Concentrator. IEEE Trans. Appl. Supercond. 2016, 26, 1–4. [Google Scholar] [CrossRef]
  4. Bhasme, N.R.; Mandval, B. Topologies of Voltage Source Inverter for Domestic Induction Heating. J. Sci. Eng. Res. 2015, 6, 121–126. [Google Scholar]
  5. Yeon, J.; Park, M.; Cho, K.; Kim, H. Field stop shorted anode trench IGBT for induction heating appliances. In Proceedings of the 38th Annual Conference on IEEE Industrial Electronics Society (IECON 2012), Montreal, QC, Canada, 25–28 October 2012; pp. 422–426. [Google Scholar] [CrossRef]
  6. Yeon, J.; Park, M.; Cho, K.; Kim, H. A new high voltage shorted-anode IGBT with intrinsic body diode improves performance of single-ended induction cooker. In Proceedings of the 15th European Conference on Power Electronics and Applications (EPE 2013), Lille, France, 2–6 September 2013; pp. 1–9. [Google Scholar] [CrossRef]
  7. Crisafulli, V. New IHR Field Stop II IGBT technology, the best efficiency for high frequency Induction Cooking Applications. In Proceedings of the International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management (PCIM Europe 2014), Nuremberg, Germany, 20–22 May 2014; pp. 873–880. [Google Scholar]
  8. Tanimatsd, H.; Ahmed, T.; Hirota, I.; Yasui, K.; Iwai, T.; Omori, H.; Ahmed, N.; Lee, H.; Nakaoka, M. Two-switch boost-half bridge and boost active clamped ZVS-PWM AC-AC converters for consumer high frequency induction heater. In Proceedings of the Twentieth Annual IEEE Applied Power Electronics Conference and Exposition (APEC 2005), Austin, TX, USA, 6–10 March 2005; Volume 2, pp. 1124–1130. [Google Scholar] [CrossRef]
  9. Pérez-Tarragona, M.; Sarnago, H.; Lucía, Ó.; Burdío, J. Design and Experimental Analysis of PFC Rectifiers for Domestic Induction Heating Applications. IEEE Trans. Power Electron. 2018, 33, 6582–6594. [Google Scholar] [CrossRef]
  10. Fairchild Semiconductor. Induction Heating System Topology Review, AN-9012, Rev 1.0.4 12/18/13; Fairchild Semiconductor: Sunnyvale, CA, USA, 2000. [Google Scholar]
  11. Yeon, J.; Cho, K.; Kim, H. A 3.6 kW Single-ended Resonant Inverter for Induction Heating Applications. In Proceedings of the 17th European Conference on Power Electronics and Applications (EPE’15 ECCE-Europe), Geneva, Switzerland, 8–10 September 2015; pp. 1–7. [Google Scholar] [CrossRef]
  12. Sarnago, H.; Lucía, O.; Mediano, A.; Burdío, J.M. A Class-E Direct AC–AC Converter With Multicycle Modulation for Induction Heating Systems. IEEE Trans. Ind. Electron. 2014, 61, 2521–2530. [Google Scholar] [CrossRef]
  13. Lucia, O.; Burdio, J.; Millan, I.; Acero, J.; Puyal, D. Load-Adaptive Control Algorithm of Half-Bridge Series Resonant Inverter for Domestic Induction Heating. IEEE Trans. Ind. Electron. 2009, 56, 3106–3116. [Google Scholar] [CrossRef]
  14. Kim, C. Minimization of Abnormal Output Voltage Rising for LLC Resonant Converter at Very Light Load. IEEE Trans. Ind. Electron. 2019, 67, 1–9. [Google Scholar] [CrossRef]
  15. Cai, M.; Wasynczuk, O.; Saeedifard, M. A Voltage- Edge-Rate-Limiting Soft-Switching Inverter Based on Auxiliary Resonant Pole. IEEE J. Emerg. Sel. Top. Power Electron. 2019, 7, 736–744. [Google Scholar] [CrossRef]
  16. Divan, D.; Skibinski, G. Zero-Switching-Loss Inverters for High-Power Applications. IEEE Trans. Ind. Appl. 1989, 25, 634–643. [Google Scholar] [CrossRef]
  17. Kim, H.; Leu, C.; Farrington, R.; Lee, F. Clamp Mode Zero-Voltage-Switched Multi-Resonant Converters. In Proceedings of the 23rd Annual IEEE Power Electronics Specialists Conference (PESC 1992), Toledo, Spain, 29 June–3 July 1992; pp. 18–24. [Google Scholar] [CrossRef]
  18. Lee, D.; Hyun, D. A new hybrid Control Scheme Using Active-Clamped Class-E Inverter with Induction Heating Jar for High Power Application. In Proceedings of the 17th Annual IEEE Applied Power Electronics Conference and Exposition (APEC 2002), Dallas, TX, USA, 10–14 March 2002; Volume 2, pp. 1148–1153. [Google Scholar] [CrossRef]
  19. Park, N.; Lee, D.; Hyun, D. A Study on the New Control Scheme of Class-E Inverter for IH-Jar Application with Clamped Voltage Characteristics Using Pulse Frequency Modulation. IET Electr. Power Appl. 2007, 1, 433–438. [Google Scholar] [CrossRef]
  20. Kranprakon, P.; Sangswang, A.; Naetiladdanon, S. Model predictive control of LLC resonant inverter for induction furnace. In Proceedings of the 2017 International Electrical Engineering Congress (IEECON), Pattaya, Thailand, 8–10 March 2017; pp. 1–4. [Google Scholar] [CrossRef]
  21. Oh, Y.; Yeon, J.; Cho, K.; Kim, H. Resonant voltage limiting technique of single-ended resonant inverter for induction heating. Electron. Lett. 2017, 53, 804–806. [Google Scholar] [CrossRef]
  22. Oh, Y.; Cho, K. Load State Detection Method of the Single-Ended Resonant Inverter for the Induction Heating Rice Cooker. J. Korean Inst. Inf. Technol. 2020, 18, 43–54. [Google Scholar] [CrossRef]
Figure 1. The circuit of a single-ended (SE) resonant inverter for induction heating.
Figure 1. The circuit of a single-ended (SE) resonant inverter for induction heating.
Energies 14 04545 g001
Figure 2. Operation modes of the single-ended (SE) resonant inverter: (a) mode I (t0~t1); (b) mode II (t1~t2); (c) mode III (t2~t3); (d) mode IV (t3~t0).
Figure 2. Operation modes of the single-ended (SE) resonant inverter: (a) mode I (t0~t1); (b) mode II (t1~t2); (c) mode III (t2~t3); (d) mode IV (t3~t0).
Energies 14 04545 g002
Figure 3. Theoretical waveforms of the single-ended (SE) resonant inverter.
Figure 3. Theoretical waveforms of the single-ended (SE) resonant inverter.
Energies 14 04545 g003
Figure 4. Equivalent circuits of switching device Q status of the SE resonant inverter: (a) equivalent circuit for the switching device, Q, in turned-on status; (b) equivalent circuit for the switching device, Q, in turned-off status.
Figure 4. Equivalent circuits of switching device Q status of the SE resonant inverter: (a) equivalent circuit for the switching device, Q, in turned-on status; (b) equivalent circuit for the switching device, Q, in turned-off status.
Energies 14 04545 g004
Figure 5. Sequence flowchart for resonant voltage control.
Figure 5. Sequence flowchart for resonant voltage control.
Energies 14 04545 g005
Figure 6. Configuration of the single-ended (SE) resonant inverter for the 1.35 kW domestic induction rice cooker used in the experiment.
Figure 6. Configuration of the single-ended (SE) resonant inverter for the 1.35 kW domestic induction rice cooker used in the experiment.
Energies 14 04545 g006
Figure 7. Image of the main printed circuit board (PCB).
Figure 7. Image of the main printed circuit board (PCB).
Energies 14 04545 g007
Figure 8. Experimental waveforms under a normal source voltage (220 V): (a) waveforms of vCE and iLeq; (b) enlarged waveforms at peak positions.
Figure 8. Experimental waveforms under a normal source voltage (220 V): (a) waveforms of vCE and iLeq; (b) enlarged waveforms at peak positions.
Energies 14 04545 g008
Figure 9. Experimental waveforms under source voltage fluctuations: (a) a conventional system; (b) the proposed system.
Figure 9. Experimental waveforms under source voltage fluctuations: (a) a conventional system; (b) the proposed system.
Energies 14 04545 g009
Figure 10. Experimental result using hardware limitation: (a) experimental waveforms; (b) circuit diagram.
Figure 10. Experimental result using hardware limitation: (a) experimental waveforms; (b) circuit diagram.
Energies 14 04545 g010
Table 1. Parameters of the experimental setup.
Table 1. Parameters of the experimental setup.
ParameterValue
Rated source voltage220 [V]
Rated source current6.14 [A]
Rated input power1350 [W]
Ratings of bridge diode600 [V]/15 [A]
Inductance of chock coil660 [μH]
Capacitance of Cr0.22 [μF]
Inductance of Leq90 [μH]
Resistance of Req4 [Ω]
Frequency of fs24–50 [kHz]
Ratings of switching IGBT1350 [V]/30 [A]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Oh, Y.; Yeon, J.; Kang, J.; Galkin, I.; Oh, W.; Cho, K. Sensorless Control of Voltage Peaks in Class-E Single-Ended Resonant Inverter for Induction Heating Rice Cooker. Energies 2021, 14, 4545. https://doi.org/10.3390/en14154545

AMA Style

Oh Y, Yeon J, Kang J, Galkin I, Oh W, Cho K. Sensorless Control of Voltage Peaks in Class-E Single-Ended Resonant Inverter for Induction Heating Rice Cooker. Energies. 2021; 14(15):4545. https://doi.org/10.3390/en14154545

Chicago/Turabian Style

Oh, Yongseung, Jaeeul Yeon, Jayoon Kang, Ilya Galkin, Wonsoek Oh, and Kyumin Cho. 2021. "Sensorless Control of Voltage Peaks in Class-E Single-Ended Resonant Inverter for Induction Heating Rice Cooker" Energies 14, no. 15: 4545. https://doi.org/10.3390/en14154545

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop