Next Article in Journal
Variability of Normative Properties of Wood Chips and Implications to Quality Control
Next Article in Special Issue
Sustainability of Shallow Geothermal Energy for Building Air-Conditioning
Previous Article in Journal
Emission Mitigation and Energy Security Trade-Off: Role of Natural Gas in the Indian Power Sector
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Embodied Energy and Embodied GWP of Windows: A Critical Review

by
Francesco Asdrubali
*,
Marta Roncone
and
Gianluca Grazieschi
Department of Engineering, Roma Tre University, 00146 Rome, Italy
*
Author to whom correspondence should be addressed.
Energies 2021, 14(13), 3788; https://doi.org/10.3390/en14133788
Submission received: 28 May 2021 / Revised: 13 June 2021 / Accepted: 21 June 2021 / Published: 24 June 2021
(This article belongs to the Special Issue Carbon, Water, Energy, and Land-Use Footprint)

Abstract

:
The construction sector is one of the most energy-intensive in the industrialized countries. In order to limit climate change emissions throughout the entire life cycle of a building, in addition to reducing energy consumption in the operational phase, attention should also be paid to the embodied energy and CO2 emissions of the building itself. The purpose of this work is to review data on embodied energy and GWP derived from EPDs of different types of windows, to identify the LCA phases, the most impacting materials and processes from an environmental point of view and to perform a critical analysis of the outcomes. The results show a strong dependence on the typology of the frame, with wooden windows having competitive performances: lower average primary energy non-renewable (1123 MJ/FU), higher average primary energy renewable (respectively 817 MJ/FU) and lower global warming potential (54 kgCO2eq/FU). More transparency and standardization in the information conveyed by the program operators is, however, desirable for a better comparability of windows performances. In particular, the inclusion of the operational impact in the EPD is sporadic, but strongly important, since it can be the most impactful phase.

1. Introduction

Windows are important components of a building’s envelope: they play both a functional/technical and an aesthetical role. Regarding the technical aspect, windows are requested to separate the inner space from the outdoor environment controlling the sunlight entering the rooms, the daylighting, guaranteeing an adequate level of thermal insulation and, if they are openable, also ventilation.
On the other hand, transparent surfaces allow contact with the landscape and are often used by architects as framing for views.
The architecture of the 19th century started giving transparent surfaces an increasing importance in building design, especially for non-residential constructions. The increment of the window to wall ratio is often linked to an increase of the energy consumptions of the building, particularly in hot climates where the excessive solar gain brings to an increase in cooling energy requirements. Considering the heating period, instead, the drawback of large transparent surfaces is linked to the fact that windows are usually the weakest part of the envelope for their higher thermal transmittance, for the presence of thermal bridges at their borders and for the potential of air infiltration.
The recent sensibility to energy efficiency and climate change issues brought to a higher attention to the selection of window typologies and to the role that they can play in reducing the environmental impact of a building [1,2]. The design of windows can in fact influence the visual, thermal and acoustical comfort in buildings. Thermal aspects are surely very important when the operational energy use in buildings, and related environmental impacts, has to be reduced. The reduction of operational energy is, in fact, a key strategy to also cut the life cycle environmental impacts of constructions [3], and it is strongly boosted by European legislation [4]. The energy saving potential achievable trough the substitution of old windows with new high performance ones was investigated by different authors: Kaklauskas et al. [5] showed that, even if the intervention is slowly repaid and not very effective in comparison with other energy retrofit measures, a multicriteria decision method should be adopted considering also the functional and aesthetic obsolescence of existing windows. Noise problems, air infiltrations and glare are also aspects that should also be taken into consideration when managing some substitution interventions. Low-emissivity coatings can significantly improve the thermal properties of windows allowing high-frequency radiation to permeate and trapping lower frequency radiant heat. On the other hand, new buildings should be equipped with high performance windows to meet the more and more stringent standards on energy efficiency.
Inevitably, the substitution of old windows with new ones with higher performances increases the embodied impacts of transparent components.
Thus, the aim of this work is to review data about embodied energy and embodied Global Warming Potential (GWP) derived from Environmental Product Declarations (EPD): this kind of data analysis was already proposed by different literature studies [6,7] for the comparison of the environmental impacts of building insulation materials, and this study tries to extend the analysis to other building components such as windows. For insulation materials the variation of the thickness permits to define a functional unit (FU equal to 1 m2 with a thermal resistance of 1 m2K/W and a design life span of 50 years) able to describe a quite uniform operational performance; this is not the case of windows for which the definition of a functional unit able to normalize both embodied and operational performances is very difficult. However, comparisons among homogenous types of windows were performed.
The paper is structured as follows: Section 2 gives a state of the art about window typologies and related environmental burdens; Section 3 introduces the methodology adopted to review EPD data; Section 4 shows the results obtained and the limitations of the analysis; Section 5 draws the conclusions.

2. State of the Art

Several studies have dealt in recent years with the energy and environmental performance of windows, with particular regard to innovative windows.
Hee et al. [8] proposed a distinction between static windows, that have constant thermal and optical properties, and dynamic ones. Dynamic properties can be activated by electrical currents (electrochromic glazing) or by heat (thermotropic windows). Electrochromic glazing is the most popular solution for dynamic windows and guarantees a wide dimming of optical properties that can reach the ones of a quite completely opaque layer: Oh et al. [9] reported a Solar Heat Gain Coefficient (total fraction of transmitted solar energy across all solar wavelengths) SHGC = 0.107 and a visible transmittance (total fraction of transmitted solar energy across the visible spectrum) Tvis = 0.085 while Sbar et al. [10] showed a SHGC = 0.09 and a Tvis ≤ 2% in the fully tinted state.
Emerging glazing technologies are spreading in the market. These include aerogel glazing, phase change materials glazing, prismatic glazing, and vacuum glazing.
The application of aerogel can be, for example, considered in order to reduce the thermal transmittance of the frames: Paulos and Berardi [11] showed that the filling of frame cavities with the aerogel can create window frames with a thermal transmittance lower than 0.5 W/m2K, a value that is very close to the one of walls and roofs. Photovoltaic glazing can also play an important role, since it permits balancing electricity generation and daylight penetration.
Currently, the increase of transparent surfaces in modern architecture and at the same time of the thermal insulation of buildings’ envelope has raised some overheating issues, even in cold climates [12]: the most reasonable solution is the reduction of the transparent surface, the installation of shading systems or, even better from a cost-effectiveness perspective, the use of glazing with solar control. Generally speaking, windows with a low SHGC should be preferred in hot climates, while a higher attention should be given to the thermal transmittance in cold areas [13]. Baldinelli et al. [14] showed that, in temperate climates, the proper control of the solar radiation through solar treatments (such as low emissive glass or films) is one of the most promising solutions to optimize the windows from both the economic and the LCA points of view. In this context, a complete LCA represents a useful strategy to guide designers in the selection of windows with high energy efficiency and low environmental impact.
The different types of windows can be defined on the basis of the material that constitutes the frame (wood, PVC, aluminum), the presence or absence of the thermal break and the type of insulating glass used (double or triple). Souviron et al. [15] proposed a comprehensive review of the environmental issues related to windows, glazing and frames. Their embodied environmental properties depend on:
  • Dimensions;
  • Life span assumptions;
  • Typology and number of glasses employed (float, float with low-e treatment, laminated, tempered);
  • Typology of the frame (wood, PVC, aluminum with thermal cut, aluminum without thermal cut);
  • Thermal resistance of the window.
In order to eliminate the dependence due to dimensions, the FU that is often adopted for the LCA is the gross surface of the window that includes the external frame. This kind of normalization may be more favorable for large windows since the impact of the frame, which is sometimes higher than the one of the glass parts, are spread over a large surface. Therefore, the use the square meter as FU is consolidated and recommended also by Product Category rules (PCR). Table 1 reports the FU used in the literature works analyzed in the present section.
Wooden frames generally have low levels of embodied energy and carbon dioxide emissions related to production processes, and some better thermal characteristics; the production of aluminum is on the contrary among the most energy-intensive, followed by that of PVC, which is also responsible for high emissions of hydrocarbons, dioxins, vinyl chloride, phthalates and heavy metals.
Several researchers have compared the environmental impacts related to the use of the three aforementioned frames—made of aluminum, PVC and wood—on typical residential windows, characterized by the same geometry and double-glazed system, highlighting that aluminum has the greatest environmental impact. This is due to the energy-intensive production processes and the pollutants deriving from the processes, while those in wood have obtained the best environmental performance as both the processing and production of wooden frames is not energy-intensive like other materials [16]. According to [17], the quantities of incorporated energy needed to produce a standard window of 1.2 m × 1.2 m are equal to: 2980 MJ for PVC windows, 6000 MJ for aluminum windows, 995 MJ for wooden windows and 1460 MJ for aluminum-wooden windows.
Therefore, as regards the frame, some authors [18,19] attributed to wooden frames a lower embodied energy in comparison with other materials such as aluminum and PVC, but also a lower service life (about 40 years). Moreover, wooden materials have carbon sequestration capacities that can be considered as a carbon credit if the origin forests are managed in a sustainable way; the emissions linked to the landfill or incineration of wooden frames during the end-of-life stage should, however, be taken into account too.
Moreover, comparing a PVC window with a wooden one, we find a consumption of coal and oil, which is three times higher in the production phase of raw materials, and a production of CO2, which is seven times higher [22].
Saadatian et al. [13] found out that the wooden frame leads to a 14–24% reduction of the embodied impacts of windows within all impact categories; on the contrary, the aluminum frame leads to a 29–49% increase in all the embodied burdens. Moreover, the typology of frame seems to have a very low influence on operational impacts of windows, demonstrating the strong importance of the control of embodied impacts [24]. Salazar et al. [22,25] noted a similar amount of cradle-to-gate emission for all the most diffused residential frame systems in North America: PVC, fiberglass, and wood covered with an aluminum cladding. The aluminum cladding reduces the maintenance requirements of a wooden frame, but worsens its environmental performance: the only factors concurring in the determination of the competitiveness of different frames remain to be a longer service life and a lower replacement frequency. The inclusion of the use stage awards the solutions able to minimize the energy demand of the buildings where the window is installed and underlines the quite insignificant contribution of the embodied components [26]. This furthermore supports the increment of embodied burdens to reduce operational ones.
For a correct estimate of the environmental impact of windows, it is therefore necessary to evaluate the entire life cycle (see LCA phases in Table 2) in order to include the durability characteristics of the materials and the maintenance processes required to maintain the performance over time. In fact, materials such as aluminum and steel guarantee greater durability and less maintenance over time [27], while less durable materials such as wood and PVC fail to meet high and controllable durability requirements.
The determination of the service life of a window is, however, very complex since it is linked to different variables that include materials and finishes typologies, maintenance frequencies, but also external climatic stressing conditions [21]. Wooden material, in particular, is very sensitive to wet conditions, and a continuous exposure to moisture can threaten its structural integrity or cause biological colonization. Moreover, frequently, the climatic stress causes the detachment of the protective coating applied on wood. PVC is subjected to thermal degradation, that manifests itself in form of scratches, localized corrosion or erosion, and to ultraviolet induced discoloration [28]. Aluminum and steel are both subjected to corrosion.
The durability of the frame affects the environmental sustainability of the window frame, in general the different studies agree on values between 30 and 50 years, in relation to the type of material and the quality of the maintenance carried out [29,30].
Limited literature was found about the environmental performance of dynamic windows and innovative glazing systems. Syrrakou et al. [23] calculated the embodied impacts for the production of a electrochromic glazing window of dimensions equal to 40 cm per 40 cm. The scale of the experiment is not very representative of a real situation, but very low energy and economic payback times are estimated: respectively, 2 and 3.2 years.

3. Materials and Methods

The analysis is based on a review of data of the environmental impacts of same types of windows (double or triple glazing and different frame materials) derived from EPD in compliance with the standard EN 15804:2012 [32] or its updates.
As far as impact categories, the indicators are related to the core impact categories defined in the European standards EN 15804:2012. In particular, the main indicators that were considered are:
  • Total non-renewable primary energy (PENRT), which represents the sum of non-renewable energy sources both used as raw materials and energy fluxes. In order to distinguish the renewable from the non-renewable part or the materials or energy sources characterizing the fabrication process of a product, the life cycle single issues indicator cumulative energy demand (CED) is usually employed [33].
  • Total renewable primary energy (PER), that sums the renewable energy sources input in the production processes considered as raw materials or energy fluxes.
  • Global warming potential (GWP), that quantifies the greenhouse gas emissions spread in the atmosphere. The adopted unit is the kgCO2eq/FU, and the evaluation time horizon is 100 years. The GWP, calculated following the methodology suggested by the standard EN 15804, includes biogenic carbon as a negative contribution to the greenhouse effect.
The limitation to the embodied stages is also linked to the fact that the EPD that were found adopt a cradle to gate approach avoiding reporting information about the operational impacts attributable to windows. Only in few cases, end-of-life impacts are calculated, but the few available data do not permit to derive significant results.
The adopted FU is equal to 1 m2 of window that includes the frame. In case the FU adopted by the EPD is different (e.g., a window of representative dimensions 1.23 × 1.48 m2), the resulting values of environmental impact were normalized by its gross surface. The representative dimensions of a window are introduced by the ISO 10077 [34].

Origin of the Data and Description of the Dataset

A total number of 80 EPDs were collected, and this allowed to create a dataset characterized by 116 values for all the covered impact categories (PERN, PER and GWP).
The materials of the frame of the sample are 42% aluminum, 20% wood, 17% PVC, 12% wood and aluminum and finally 9% n steel (Figure 1).
To guarantee an adequate level of temporal and geographical representativeness, all the EPDs gathered were not expired and referred to windows products sold in the European market.
An extended and detailed data collection was performed; the following EPD databases developed by European program operators were consulted:
  • Baubook (Bau) [35]: it is an EPD database developed within the tool Ecosoft and promoted by the Austrian government. All the environmental impact indicators are elaborated using SimaPro software and are based on CML2 Baseline 2001;
  • EPD Denmark (Den) [36]: it is a database for construction products managed by a Denmark organization, which works for a consistent level of quality and content of EPDs in Europe, offering its services for small- and medium-sized enterprises;
  • Ecoinvent (EcI) [37]: it is one of the LCA leader databases all over the world. In this work, only data referring to the European area were selected;
  • Environdec (Env) [38]: it is a collection of EPDs of a wide range of products from all over the world managed by The International EPD System, a Sweden settled company;
  • EPD Italy (Ita) [39]: it is the Italian database born in 2016 and collecting EPD of different kinds of construction products;
  • EPD Norge (Nor) [40]: it is an EPD database managed by a Norwegian program operator;
  • European Aluminium database (Ead) [41]: it is an international non-profit association representing different members of the aluminum industry and settled in Brussels. Since 2006, European Aluminium has promoted a program for the development of EPDs of aluminum products (aluminum windows, doors, curtain walls, composite panels, cladding or roofing); own-developed PCRs and EPDs are compiled in compliance with EN 15804:2019;
  • GBCe (Gbc) [42]: it is a Spanish platform for EPD managed by the Green Building Council of Spain;
  • IBU [43]: it is a German program operator that manages an online database of EPDs;
  • EPD Ireland (Irl) [44]: it is a platform to source products with EPDs managed by the Irish Green Building Council;
  • INIES (Ini) [45]: it is a French collection of LCA information provided voluntarily by manufacturers and trade associations;
  • Kawneer (Kaw) [46]: it is a manufacturer of aluminum systems and products that has certified some of its products;
  • Ökobaudat (Öko) [47]: it is a German database containing a lot of EPDs realized in compliance with the DIN EN 15,804 standard. The database includes both generic data and product specific ones and only the latter were considered for this study;
  • Ift Rosenheim (Ros) [48]: it is a scientific service provider for manufacturers of windows and facades based in Rosenheim, Germany. The institute creates EPDs for windows and for all buildings envelope products.
Figure 2 shows the share of every program operator in the total amount of analyzed data. INIES (23%), EPD Norge (19%) and European Aluminium (18%) database represent the most important sources of data and all together they account for the 60% of the sample. If the contribution of Baubook (10%), Denmark (5%), Environdec (4%) and GBCe (4%) is also added, these seven databases arrive to cover the 84% of the sample; a residual contribution is finally given by the remaining databases and program operators.
Table 3 lists the number of PENR, PER or GWP values obtained reporting, for every window typology, the reference database from which data were gathered.
It is important to underline that no EPD was found for innovative and dynamic windows. This can be explained by the current limited market distribution of these kinds of windows, but also by the scarceness of literature studies developing LCA about them.

4. Results

The thermo-physical, acoustic and durability properties are reported in Table 4 for every window typology considered. Not all the environmental certifications analyzed reported all the parameters shown in Table 4.
While all of them report the thermal transmittance of the entire window, 74% of them contains acoustic properties and 86% have information about the durability of the certified product. Moreover, scarce information was also found about the typology of the glass employed (e.g., float, tempered, laminated), that is supposed to be float for all cases, and about the thickness of panes.
Table 5 shows the number of EPDs and their percentage value with respect to the entire sample of data in relation to each LCA phase. The life cycle phases considered are the production stage (A1–A3, see Table 2) in all cases with more limited EPDs reporting impacts linked to the end-of-life (43% of the total as shown in Table 5).
The use phase is the most neglected one (considered only by 31% of the sample) along with the related impacts concerning the maintenance requirements (taken into account by 45% of EPDs consulted), that, as already shown in Section 2, can represent a relevant phase able to influence the overall environmental performance of the window. The exclusion of the operational stage is an important limitation since it is the most impacting stage, as already pointed out by the literature analyzed in Section 2. Finally, 79% of the sample considers phases C4 and D.
It could be expected that a reduction of thermal transmittance of the window would bring an increase of the environmental impacts considered, due to the increase in the amount of materials employed for the manufacture. Instead, no significant statistical relationship was found. Similarly, when searching some statistical relations correlating the environmental results considered with the parameters reported in Table 4 (Sound Reduction Index-Rw and durability), no significant result was gathered.
This finding underlines how the environmental properties of commercialized windows principally vary in function of the typology of material employed for the frames and plates, on their recyclable content, on the energy mix that characterized the fabrication process, and that some low embodied energy/carbon components or design precautions can be very effective in reducing energy losses and infiltrations. In the same way, considering durability (see column four of Table 4), the gathered data do not permit us to confirm some literature works that assign a lower durability to wooden frames.
The end-of-life phase also plays an important role in relation to the frame material. The recyclability of window materials has a fundamental role in reducing environmental impacts, particularly in case of frequent substitutions. The resulting benefit depends on the material and can be indicated separately in EPDs. Glass is destinated to landfill for the 65%, while the remaining part is recycled for different uses (only 10% is destinated to the production of new float glass since high quality material is necessary [49]); wood is usually burned for energy valorization or landfilled if deeply treated superficially; PVC has a high recyclable potential, but the process is still characterized by high costs and impacts so that landfilling is often preferred; aluminum is recycled with a recovery rate of 95% and without loss of quality, but only less than the half of the material of windows profiles is recycled [50].
Another technical factor that can have an important drawback in the operation performance of windows is their air tightness that depends on the precision in their manufacturing and building assembly rather than on their maintenance conditions. This kind of information requires hypotheses that are hard to be made within environmental declarations: in fact, no data were collected from the analyzed EPDs.
Figure 3 and Figure 4 display the mean value, the median (the central line), the values of first and third quartiles (the limits of the box) and the minimum and maximum values (the whiskers) for the PENR, PER and GWP of the analyzed windows: the data are evaluated for different frame materials and for the type of glass since literature reviewed in Section 2 already had underlined a strong dependence on these two characteristics.
Instead, Table 6 and Table 7 show the minimum, maximum and average values for PENR, PER and GWP of the different types of windows.
Among the double-glazed windows analyzed (Table 6), those in wood have the lowest PENR, equal to 699 MJ/FU, while those in aluminum have the highest maximum value, equal to 2770 MJ/FU. Comparing the PENR values between the triple glazed windows of the sample (7), it can be observed that those with the lowest value are in wood (1313.9 MJ/FU) and those with the highest value are in steel (4445 MJ/FU). Evaluating the PER, the highest average values are recorded for windows made of wood-aluminum (1154.8 MJ/FU), while the lowest values are recorded for those in steel (215.9 MJ/FU). Finally, the highest average value recorded for GWP belongs to steel (168.8 kgCO2eq/FU), while the lowest belongs to wood (53.6 kgCO2eq/FU).
As it can be noted, it is very difficult to compare the environmental performance of the three different frame materials: in some cases, similar values were obtained that do not permit to derive consistent conclusions. It is possible to assert that wooden frames have sensible higher PER and lower GWP because of the inclusion of biogenic material and carbon in the calculations. The issue is, however, very debated since the carbon stored in wooden materials is released in the atmosphere during the end-of life of the frame, both if it is burned for energy purposes or landfilled. The inclusion of end-of-life stages in the EPD would permit a better understanding of the real competitiveness of wooden frames along with the consideration of impacts related to maintenance, painting, and staining. Otherwise, steel results to be a very impactful material for windows frames with both higher average PENR (2125 MJ/FU for double glasses and 2810 MJ/FU for triple glasses) and GWP (127 and 169 kgCO2eq/FU, respectively, for double and triple glasses).
The values shown in Figure 4 for triple-glass windows are quite always higher due to the additional material required for their production.
Figure 5 displays the share of PENR and PER in the total embodied energy of every window. Wooden framed solutions are characterized by a higher renewable energy content that usually surpasses the 50%: it is because wooden material has itself a low embodied energy with a high renewable energy content. LCA studies tend to consider wood as a renewable energy source, even if its real renewable characterization depends on the sustainable management of forests where it comes from [19]. On the contrary for all the other framed solutions the non-renewable part often exceeds the 80%.

5. Conclusions

Transparent surfaces are important parts of the building envelope because they play aesthetic, comfort and thermophysical functions. The increase of the use of transparent surfaces in the 19th century architecture, and the current sensibility to climate change and environmental issues, has brought about the fabrication of high energy performance windows with low thermal transmittance and solar control systems. Dynamic windows are also emerging as new engineered solutions to reduce operational energy requirements in buildings. These efforts, however, brought an increase of the embodied energy and embodied CO2 emissions of window systems.
The aim of this work was to perform a review of environmental impact data obtained from the analysis of EPDs. The analysis permitted us to determine the range of variability of the embodied PENR, PER and GWP of the window systems commercialized in the European market.
The most impactful frame was shown to be the steel one with an average PENR of 2125 MJ/FU for double glasses and 2810 MJ/FU for triple glasses, and GWP 127 and 169 kgCO2eq/FU, respectively, for double and triple glasses. Aluminum and PVC frames follow: aluminum with average PENR of 1724 MJ/FU-double panes and 1932 MJ/FU-triple panes and GWP of 105 kgCO2eq/FU-double panes and of 142 kgCO2eq/FU-triple panes; PVC with average PENR of 1542 MJ/FU-double panes and 1650 MJ/FU-triple panes, and GWP of 68 kgCO2eq/FU-double panes and of 101 kgCO2eq/FU-triple panes.
Finally, wooden frames showed the lowest average PENR (1123 MJ/FU), the highest average PER (respectively 817 MJ/FU) and the lowest GWP (54 kgCO2eq/FU).
The results, however, show a high variability range for the selected embodied impacts and this variability does not fully permit “to enable comparisons between products fulfilling the same function” as required for Type III declarations by the ISO 14025. Moreover, since windows are complex building components fulfilling a lot of functions, the definition of a FU able to describe a uniform performance and to guarantee an adequate basis for the compatibility results still problematic.
An increased transparency and standardization in the information conveyed by the Program Operators is, however, desirable since it can permit a better interpretation of the results conveyed.
In particular, the definition of a common methodology frame for the determination of operational impacts is very important since this stage is generally the most impacting one in the total life cycle.

Author Contributions

Conceptualization, F.A.; methodology, F.A. and G.G.; investigation, M.R. and G.G.; data curation, M.R. and G.G.; writing—original draft preparation, M.R. and G.G.; writing—review and editing, F.A.; supervision, F.A. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data available on request due to restrictions. The data presented in this study are available on request from the corresponding author. The data are not publicly available due to privacy reasons.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Orsini, F.; Marrone, P.; Asdrubali, F.; Roncone, M.; Grazieschi, G. Aerogel insulation in building energy retrofit. Performance testing and cost analysis on a case study in Rome. Energy Rep. 2020, 6, 56–61. [Google Scholar] [CrossRef]
  2. Asdrubali, F.; Venanzi, D.; Evangelisti, L.; Guattari, C.; Grazieschi, G.; Matteucci, P.; Roncone, M. An Evaluation of the Environmental Payback Times and Economic Convenience in an Energy Requalification of a School. Buildings 2020, 11, 12. [Google Scholar] [CrossRef]
  3. Ramesh, T.; Prakash, R.; Shukla, K.K. Life cycle energy analysis of buildings: An overview. Energy Build. 2010, 42, 1592–1600. [Google Scholar] [CrossRef]
  4. European Parliament and Council Directive (EU). 2018/844 of 30 May 2018 amending Directive 2010/31/EU on the energy performance of buildings and Directive 2012/27/EU on energy efficiency. Off. J. Eur. Union 2018, L 156/75, 75–91. [Google Scholar]
  5. Kaklauskas, A.; Zavadskas, E.K.; Raslanas, S.; Ginevicius, R.; Komka, A.; Malinauskas, P. Selection of low-e windows in retrofit of public buildings by applying multiple criteria method COPRAS: A Lithuanian case. Energy Build. 2006, 38, 454–462. [Google Scholar] [CrossRef]
  6. Hill, C.; Norton, A.; Dibdiakova, J. A comparison of the environmental impacts of different categories of insulation materials. Energy Build. 2018, 162, 12–20. [Google Scholar] [CrossRef]
  7. Grazieschi, G.; Asdrubali, F.; Thomas, G. Embodied energy and carbon of building insulating materials: A critical review. Clean. Environ. Syst. 2021, 2, 100032. [Google Scholar] [CrossRef]
  8. Hee, W.J.; Alghoul, M.A.; Bakhtyar, B.; Elayeb, O.; Shameri, M.A.; Alrubaih, M.S.; Sopian, K. The role of window glazing on daylighting and energy saving in buildings. Renew. Sustain. Energy Rev. 2015, 42, 323–343. [Google Scholar] [CrossRef]
  9. Oh, M.; Park, J.; Roh, S.; Lee, C. Deducing the Optimal Control Method for Electrochromic Triple Glazing through an Integrated Evaluation of Building Energy and Daylight Performance. Energies 2018, 11, 2205. [Google Scholar] [CrossRef] [Green Version]
  10. Sbar, N.L.; Podbelski, L.; Yang, H.M.; Pease, B. Electrochromic dynamic windows for office buildings. Int. J. Sustain. Built Environ. 2012, 1, 125–139. [Google Scholar] [CrossRef] [Green Version]
  11. Paulos, J.; Berardi, U. Optimizing the thermal performance of window frames through aerogel-enhancements. Appl. Energy 2020, 266, 114776. [Google Scholar] [CrossRef]
  12. Aste, N.; Buzzetti, M.; Del Pero, C.; Leonforte, F. Glazing’s techno-economic performance: A comparison of window features in office buildings in different climates. Energy Build. 2018, 159, 123–135. [Google Scholar] [CrossRef]
  13. Saadatian, S.; Simões, N.; Freire, F. Integrated environmental, energy and cost life-cycle analysis of windows: Optimal selection of components. Build. Environ. 2021, 188, 107516. [Google Scholar] [CrossRef]
  14. Baldinelli, G.; Asdrubali, F.; Baldassarri, C.; Bianchi, F.; D’Alessandro, F.; Schiavoni, S.; Basilicata, C. Energy and environmental performance optimization of a wooden window: A holistic approach. Energy Build. 2014, 79, 114–131. [Google Scholar] [CrossRef]
  15. Souviron, J.; van Moeseke, G.; Khan, A.Z. Analysing the environmental impact of windows: A review. Build. Environ. 2019, 161, 106268. [Google Scholar] [CrossRef]
  16. Sinha, A.; Kutnar, A. Carbon Footprint versus Performance of Aluminum, Plastic, and Wood Window Frames from Cradle to Gate. Buildings 2012, 2, 542–553. [Google Scholar] [CrossRef] [Green Version]
  17. Velfac Cradle to Grave: The Comparison of Window Life Cycles. Available online: https://velfac.co.uk/commercial/consultancy/cpd/cradle-to-grave/ (accessed on 3 May 2021).
  18. Citherlet, S.; Di Guglielmo, F.; Gay, J.-B. Window and advanced glazing systems life cycle assessment. Energy Build. 2000, 32, 225–234. [Google Scholar] [CrossRef]
  19. Asdrubali, F.; Ferracuti, B.; Lombardi, L.; Guattari, C.; Evangelisti, L.; Grazieschi, G. A review of structural, thermo-physical, acoustical, and environmental properties of wooden materials for building applications. Build. Environ. 2017, 114. [Google Scholar] [CrossRef]
  20. Asif, M.; Muneer, T.; Kubie, J. Sustainability analysis of window frames. Build. Serv. Eng. Res. Technol. 2005, 26, 71–87. [Google Scholar] [CrossRef]
  21. Fernandes, D.; de Brito, J.; Silva, A. Methodology for service life prediction of window frames. Can. J. Civ. Eng. 2019, 46. [Google Scholar] [CrossRef] [Green Version]
  22. Salazar, J.; Sowlati, T. A review of life-cycle assessment of windows. For. Prod. J. 2008, 58, 91–96. [Google Scholar]
  23. Syrrakou, E.; Papaefthimiou, S.; Yianoulis, P. Environmental assessment of electrochromic glazing production. Sol. Energy Mater. Sol. Cells 2005, 85, 205–240. [Google Scholar] [CrossRef]
  24. Asdrubali, F.; Baldinelli, G.; Bianchi, F. Influence of cavities geometric and emissivity properties on the overall thermal performance of aluminum frames for windows. Energy Build. 2013, 60, 298–309. [Google Scholar] [CrossRef]
  25. Salazar, J.; Sowlati, T. Life cycle assessment of windows for the North American residential market: Case study. Scand. J. For. Res. 2008, 23, 121–132. [Google Scholar] [CrossRef]
  26. Salazar, J. Life cycle assessment (LCA) of windows and window materials. In Eco-Efficient Construction and Building Materials; Elsevier: Amsterdam, The Netherlands, 2014; pp. 502–527. [Google Scholar]
  27. Lyons, A. Materials for Architects and Builders; Routledge: London, UK, 2020; ISBN 9780815363392. [Google Scholar]
  28. González, A.; Pastor, J.M.; De Saja, J.A. Monitoring the UV degradation of PVC window frames by microhardness analysis. J. Appl. Polym. Sci. 1989, 38, 1879–1882. [Google Scholar] [CrossRef]
  29. Menzies, G.F.; Wherrett, J.R. Windows in the workplace: Examining issues of environmental sustainability and occupant comfort in the selection of multi-glazed windows. Energy Build. 2005, 37, 623–630. [Google Scholar] [CrossRef]
  30. Menzies, G.F. Whole Life Analysis of timber, modified timber and aluminiumclad timber windows. Available online: https://researchportal.hw.ac.uk/en/publications/whole-life-analysis-of-timber-modified-timber-and-aluminium-clad- (accessed on 18 May 2021).
  31. Wiklund, U. PCR 2014:02 Buildings (Version 2.0). Available online: https://www.environdec.com/PCR/Detail/?Pcr=5950 (accessed on 3 May 2021).
  32. EN 15804. Sustainability of Construction Works, Environmental Product Declarations, Core Rules for the Product Category of Construction Products; CEN: Bruxelles, Belgium, 2012. [Google Scholar]
  33. Hischier, R.; Weidema, B.; Althaus, H.-J.; Bauer, C.; Doka, G.; Dones, R.; Frischknecht, R.; Hellweg, S.; Humbert, S.; Jungbluth, N.; et al. Implementation of Life Cycle Impact Assessment Methods Data v2.2, Ecoinvent Report No. 3 v2.2; Dübendorf, Swiss Centre for Life Cycle Inventories: Zurich, Switzerland, 2010; Available online: https://www.ecoinvent.org/files/201007_hischier_weidema_implementation_of_lcia_methods.pdf (accessed on 6 May 2021).
  34. ISO 10077-1, Thermal Performance of Windows, Doors and Shutters—Calculation of Thermal Transmittance; International Organization for Standardization: Geneva, Switzerland, 2017.
  35. Baubook GmbH Baubook Database. Available online: https://www.baubook.info/ (accessed on 6 May 2021).
  36. EPD Danmark EPD Danmark Database. Available online: https://epddanmark.dk/ (accessed on 18 May 2021).
  37. Wernet, G.; Bauer, C.; Steubing, B.; Reinhard, J.; Moreno-Ruiz, E.; Weidema, B. The ecoinvent database version 3 (part I): Overview and methodology. Int. J. Life Cycle Assess. 2016, 21, 1218–1230. [Google Scholar] [CrossRef]
  38. EPD International AB International EPD®® System Database. Available online: http://environdec.com/ (accessed on 6 May 2021).
  39. EPDItaly EPD Database. Available online: https://www.epditaly.it/ (accessed on 11 May 2021).
  40. The Norwegian EPD Foundation Epd-Norge. Available online: https://www.epd-norge.no/ (accessed on 11 May 2021).
  41. European Aluminium Building Products EPD-Programme According to EN 15804. Available online: https://european-aluminium.eu/resource-hub/building-products-epd-programme/ (accessed on 11 May 2021).
  42. Green Building Council España (GBCe) Declaración Ambiental de Productos. Available online: http://materiales.gbce.es/declaracion-ambiental-de-productos/ (accessed on 11 May 2021).
  43. Institut Bauen und Umwelt IBU Data. Available online: https://ibu-epd.com/en/ibu-data-start/ (accessed on 14 May 2021).
  44. Irish Green Building Council EPD Ireland. Available online: https://www.igbc.ie/epd-home/ (accessed on 14 May 2021).
  45. Association HQE INIES Life Cycle Database. Available online: https://www.inies.fr/home/ (accessed on 14 May 2021).
  46. Kawneer Product Transparency, Environmental Product Declarations. Available online: https://www.kawneer.com/kawneer/north_america/en/info_page/product_transparency.asp (accessed on 14 May 2021).
  47. German Federal Ministry of the Interior Building and Community ÖKOBAUDAT Database. Available online: https://www.oekobaudat.de/en/database/database-oekobaudat.html (accessed on 14 May 2021).
  48. IFT Rosenheim GmbH IFT EPD database. Available online: https://www.ift-rosenheim.de/en/environmental-product-declaration-epd (accessed on 18 May 2021).
  49. Maccarini Vefago, L.H.; Avellaneda, J. Recycling concepts and the index of recyclability for building materials. Resour. Conserv. Recycl. 2013, 72, 127–135. [Google Scholar] [CrossRef]
  50. European Aluminium EPD European Aluminium Reynaers 2-SlimLine 38 Door. Available online: https://european-aluminium.eu/media/1761/16-10-25-epd-2-reynaers-doors-sl-38-r02.pdf (accessed on 11 May 2021).
Figure 1. Percentage distribution of the materials of the frame of the sample.
Figure 1. Percentage distribution of the materials of the frame of the sample.
Energies 14 03788 g001
Figure 2. Share of every program operator in the total amount of values analyzed.
Figure 2. Share of every program operator in the total amount of values analyzed.
Energies 14 03788 g002
Figure 3. Embodied impacts of double-glazed window for different frame material: (a) PERN, (b) PER, (c) GWP.
Figure 3. Embodied impacts of double-glazed window for different frame material: (a) PERN, (b) PER, (c) GWP.
Energies 14 03788 g003aEnergies 14 03788 g003b
Figure 4. Embodied impacts of triple-glazed window for different frame material: (a) PERN, (b) PER, (c) GWP.
Figure 4. Embodied impacts of triple-glazed window for different frame material: (a) PERN, (b) PER, (c) GWP.
Energies 14 03788 g004aEnergies 14 03788 g004b
Figure 5. Results about the incidence (%) of PERN and PER for every window analyzed.
Figure 5. Results about the incidence (%) of PERN and PER for every window analyzed.
Energies 14 03788 g005
Table 1. Assumptions made by the analyzed literature studies.
Table 1. Assumptions made by the analyzed literature studies.
ReferenceFunctional UnitLife SpanMaintenance
Asif et al. [20]1.2 × 1.2 m2
window
Aluminum: 43.6 yearsAluminum: 20 years,
Wood + aluminum: 46.7 yearsWood: 5 years painting and 3 years staining (externally), 10 years painting and 5 years staining (internally).
Wood: 39.6 yearsPVC: 6 months cycles of cleaning with solvents.
PVC: 24.1 years
Baldinelli et al. [14]1.23 × 1.48 m2
window
30 yearsn.c.
Fernandes et al. [21]-Aluminum: 37.6 years, Wood: 27.3 yearsn.c.
Saadatian et al. [13]1.23 × 1.48 m2
window
30 yearsn.c.
Salazar et al. [22]0.6 × 1.2 m2
window
75 years for windowsn.c.
18 years for PVC frames
25 years for wood, fiberglass and aluminum frames
Syrrakou et al. [23]0.4 × 0.4 m2 electrochromic systemn.c.n.c.
Souviron et al. [15]1 m220–30 years for glazingWood frames are the most demanding in terms of maintenance.
PVC: 18–30 years
Wood: 25–65 years
Wood + aluminum: 25–83 years
Aluminum: 25–80 years
Table 2. Complete phases of the LCA analysis [31].
Table 2. Complete phases of the LCA analysis [31].
LCA Phases
A1–A3A4–A5B1–B7C1–C4D
Product StageConstruction StageUseEnd of LifeBenefits and Loads beyond the System Boundary
A1A2A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Raw Materials SupplyTransportManufacturingTransportConstruction and installation processUse/applicationMaintenanceRepairReplacementRefurbishmentOperational EnergyOperational WaterDe-construction/DemolitionTransportWaste ProcessingDisposalReuseRecoveryRecyclingExported Energy
Table 3. Complete phases of the LCA analysis.
Table 3. Complete phases of the LCA analysis.
Window TypologyValues for Each Impact Indicator (Source)Total n.
Double glass–steel framed4 Ini; 2 Oko6
Triple glass–steel framed1 Bau; 1 Ini; 1 Oko; 1 Ros4
Double glass–PVC framed1 Env; 1 Irl; 1 Gbc; 1 IBU; 7 Ini11
Triple glass–PVC framed2 Bau;1 Irl;1 Nor; 1 Gbc; 2 IBU; 2 Ini9
Double glass–wooden framed1 EcI; 1 Nor; 5 Ini7
Triple glass–wooden framed2 Bau; 1 Env; 13 Nor16
Double glass–aluminum framed1 Den; 2 Env; 1 Ita; 11 Ead; 1 IBU; 6 Ini; 1 Ros23
Triple glass–aluminum framed8 Den; 2 Ita; 10 Ead; 3 Gbc; 1 Ini; 1 Kaw; 1 Ros26
Double glass–wood + aluminum framed1 Ini; 1 Ros2
Triple glass–wood + aluminum framed4 Bau; 7 Nor; 1 Ini12
All types of windowsAll116
Table 4. Maximum and minimum value of the parameters characterizing the different window typologies.
Table 4. Maximum and minimum value of the parameters characterizing the different window typologies.
Window TypologyUw-Value 1RwDurability
[W/m2k][dB][Years]
Aluminum–double0.8–3.728–4730–50
Aluminum–triple0.7–1.528–5130–60
PVC–double1.0–1.629–4430–60
PVC–triple0.3–1.227–4430–60
Steel–double1.3–1.628–3230–50
Steel–triple0.5–1.1437.530–50
Wood–double0.6–1.427–4025–60
Wood–triple0.2–1.230–4630–60
1 Uw-value: thermal transmittance of the entire window, Rw: Sound Reduction Index.
Table 5. Number of EPDs and their percentage value with respect to the entire sample of data in relation to each LCA phase.
Table 5. Number of EPDs and their percentage value with respect to the entire sample of data in relation to each LCA phase.
Phases LCAn. EPDEPD (%)
A1–A3116100%
A1–A47060%
A1–A55043%
B14236%
B25245%
B34135%
B44337%
B1–B73631%
C1–C45043%
C15043%
C26657%
C36153%
C49279%
D9279%
Table 6. Minimum, maximum and average values for PENR, PER and GWP of the double-glazed windows analyzed according to the different frame materials.
Table 6. Minimum, maximum and average values for PENR, PER and GWP of the double-glazed windows analyzed according to the different frame materials.
Double Glass
MaterialsPENR [MJ/FU]PER [MJ/FU]GWP [kgCO2eq/FU]
Min.Max.Ave.Min.Max.Ave.Min.Max.Ave.
Aluminum993.02770.41724.2180.6540.0297.646.5146.0105.0
PVC825.82740.01542.345.2334.0133.438.6113.068.4
Steel1396.82710.42125.0127.7310.2245.685.9152.5127.3
Wood699.02550.01473.0534988.8814.131.8105.055.0
Table 7. Minimum, maximum and average values for PENR, PER and GWP of the triple-glazed windows analyzed according to the different frame materials.
Table 7. Minimum, maximum and average values for PENR, PER and GWP of the triple-glazed windows analyzed according to the different frame materials.
Triple Glass
MaterialsPENR [MJ/FU]PER [MJ/FU]GWP [kgCO2eq/FU]
Min.Max.Ave.Min.Max.Ave.Min.Max.Ave.
Aluminum719.23910.01932.2158.31090.0404.960.2324.1141.9
PVC1313.93938.01649.752.31587.5280.462.9191.8100.5
Steel1890.04445.02810.2152.4310.2215.9111.1221.0168.8
Wood450.01713.0960.1327.01387.4819.17.894.253.6
Wood-aluminum955.82766.01538.9776.21502.41154.830.999.967.6
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Asdrubali, F.; Roncone, M.; Grazieschi, G. Embodied Energy and Embodied GWP of Windows: A Critical Review. Energies 2021, 14, 3788. https://doi.org/10.3390/en14133788

AMA Style

Asdrubali F, Roncone M, Grazieschi G. Embodied Energy and Embodied GWP of Windows: A Critical Review. Energies. 2021; 14(13):3788. https://doi.org/10.3390/en14133788

Chicago/Turabian Style

Asdrubali, Francesco, Marta Roncone, and Gianluca Grazieschi. 2021. "Embodied Energy and Embodied GWP of Windows: A Critical Review" Energies 14, no. 13: 3788. https://doi.org/10.3390/en14133788

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop