Next Article in Journal
sEMG-Based Robust Recognition of Grasping Postures with a Machine Learning Approach for Low-Cost Hand Control
Previous Article in Journal
User Orientation Detection in Relation to Antenna Geometry in Ultra-Wideband Wireless Body Area Networks Using Deep Learning
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Advancements in Battery Monitoring: Harnessing Fiber Grating Sensors for Enhanced Performance and Reliability

by
Kaimin Yu
1,
Wen Chen
2,*,
Dingrong Deng
1,
Qihui Wu
1 and
Jianzhong Hao
3,*
1
School of Marine Equipment and Mechanical Engineering, Jimei University, Xiamen 361021, China
2
School of Ocean Information Engineering, Jimei University, Xiamen 361021, China
3
Institute for Infocomm Research (I2R), Agency for Science, Technology and Research (A★STAR), Singapore 138632, Singapore
*
Authors to whom correspondence should be addressed.
Sensors 2024, 24(7), 2057; https://doi.org/10.3390/s24072057
Submission received: 25 February 2024 / Revised: 19 March 2024 / Accepted: 21 March 2024 / Published: 23 March 2024

Abstract

:
Batteries play a crucial role as energy storage devices across various industries. However, achieving high performance often comes at the cost of safety. Continuous monitoring is essential to ensure the safety and reliability of batteries. This paper investigates the advancements in battery monitoring technology, focusing on fiber Bragg gratings (FBGs). By examining the factors contributing to battery degradation and the principles of FBGs, this study discusses key aspects of FBG sensing, including mounting locations, monitoring targets, and their correlation with optical signals. While current FBG battery sensing can achieve high measurement accuracies for temperature (0.1 °C), strain (0.1 μ ε ), pressure (0.14 bar), and refractive index (6 × 10−5 RIU), with corresponding sensitivities of 40 pm/°C, 2.2 pm/ μ ε , −0.3 pm/bar, and −18 nm/RIU, respectively, accurately assessing battery health in real time remains a challenge. Traditional methods struggle to provide real-time and precise evaluations by analyzing the microstructure of battery materials or physical phenomena during chemical reactions. Therefore, by summarizing the current state of FBG battery sensing research, it is evident that monitoring battery material properties (e.g., refractive index and gas properties) through FBGs offers a promising solution for real-time and accurate battery health assessment. This paper also delves into the obstacles of battery monitoring, such as standardizing the FBG encapsulation process, decoupling multiple parameters, and controlling costs. Ultimately, the paper highlights the potential of FBG monitoring technology in driving advancements in battery development.

1. Introduction

Batteries have revolutionized various industries by offering high energy density, long lifespan, and recharge ability [1,2,3]. Their widespread use in electric vehicles, energy storage systems, and mobile technologies has accelerated the global energy transition [4,5,6,7,8]. However, the complex chemical reactions in batteries pose safety risks such as thermal runaway and capacity degradation [9,10]. Even routine charging and discharging induce simultaneous changes in micro-chemical properties and macro-physical parameters, including temperature, stress, gas by-products, and electrolyte solubility. External factors such as collisions, extrusions, and environmental changes can further impact battery performance and safety [11,12]. Battery runaway phenomena typically initiate within the battery and extend throughout the entire battery, eventually reaching the battery pack. Despite extensive efforts to improve battery materials and design, these challenges persist. Consequently, the research focus has shifted towards monitoring detailed chemical changes and assessing the health states within the battery to enhance battery properties, predict service life, and provide early warnings for safety risks [13]. Table 1 outlines sensors for monitoring various parameters, along with their installation locations, advantages, and disadvantages. According to the measured battery parameter, monitoring methods can be categorized into:
(1) Detecting the microstructure or spectral properties of the battery material: Traditional methods like X-ray diffraction (XRD), scanning transmission electron microscope (STEM), Raman spectroscopy, infrared (IR) spectroscopy, nuclear magnetic resonance (NMR), and mass spectrometry enable the direct observation of the crystal structure and microscopic surface morphology of electrodes or the study of the molecular composition of liquid electrolytes. However, these methods require sample preparation and testing in the laboratory using expensive and sophisticated instruments. While accurate, they are not real-time.
(2) Detecting physical phenomena accompanying chemical reactions in batteries: The real-time monitoring of physical phenomena associated with chemical reactions (temperature changes, strains, and deformations) is typically accomplished using load cell, strain gauge, thermocouple, or IR thermography. While these methods provide real-time insight into chemical reaction processes, they have limitations in accurately depicting changes in battery characteristics and health. Thermocouples are typically placed on the surface of the cell and have limitations in directly assessing internal temperatures. Monitoring large area battery pack temperatures is challenging due to point measurements and wire conductivity issues. IR thermography, while useful, is limited by resolution and accuracy, making it difficult to accurately determine surface and internal temperatures. Load cell and strain gauge methods can measure cell expansion and contraction, but are affected by temperature.
(3) Detecting chemical properties of battery substances: Analyzing the chemical properties of battery substances, such as acidity, alkalinity, and refractive index (RI), is commonly achieved using electrochemical workstations or electrochemical analyzers. Techniques like cyclic voltammetry (CV), constant current constant voltage (CCCV), and electrochemical impedance spectroscopy (EIS) explore ionic transport during battery chemical reactions. Mass spectrometry assesses solute and solvent concentrations in the electrolyte, along with its potential of hydrogen (pH) value. Cycle life testing simulates charging and discharging cycles to study electrode material changes and electrolyte degradation in real time. While this method addresses the limitations of the previous two types, providing direct monitoring of battery material properties, the comprehensive monitoring of each battery remains impractical.
Despite the wide variety of sensors used to monitor various parameters, current sensors are still unable to provide real-time and accurate monitoring of the quality, reliability, and life (QRL) of batteries. Fiber optic sensors are prominent in battery sensing due to their compactness, high sensitivity, chemical inertness, resistance to electromagnetic interference, and multiplexing capability. Distributed fiber optic sensing, while capable of covering the battery pack comprehensively, faces challenges such as inadequate spatial resolution, low measurement accuracy, and the requirement for manual calibration with precise positioning [14]. Point-type fiber optic sensors like the Mach–Zehnder (MZ) interferometer, Michelson interferometers, Sagnac interferometers, and Fabry-–Pérot (FP) interferometers can address these issues but may struggle with monitoring the battery pack at multiple points. Quasi-distributed fiber Bragg grating (FBG) sensors offer a solution to these challenges as they can be conveniently deployed and integrated on the surface or inside the cell, delivering more precise detection results [15,16,17]. Notably, FBG spectroscopy provides insights into ionic motion at the molecular level, making it the most widely used sensor in battery sensing today [18]. However, some recent fiber optic sensors have attempted to monitor changes in battery chemistries, such as Surface Plasmon Resonance (SPR) spectroscopy, but it is difficult to use them to quantitatively characterize changes, and they do not allow for large-scale applications [19,20,21,22,23].
This paper aims to further explore the accurate measurement of battery structure health status and remaining life using FBG sensors, based on a comprehensive investigation of various types of sensing systems and their monitoring parameters. The article begins by elaborating on the chemical reaction mechanisms and potential adverse reactions within the battery during operation. Subsequently, it delves into the current application status of FBG sensors in monitoring internal parameters of batteries. Finally, it scrutinizes the future prospects and challenges associated with the application of FBG sensors in battery monitoring.
Table 1. Various battery sensing methods.
Table 1. Various battery sensing methods.
MethodParametersCharacteristicsLocation
Fiber Bragg Grating (FBG) [24]Temperature, Strain, RI, and moreSmall size, immune to electromagnetic interference, quasi-distributed measurement, and real-time monitoringInternal, External
Resistance Temperature Detector [25]TemperatureHigh accuracy, wide linear range, and slow responseInternal, External
Thermistor [26]TemperatureSmall and cost-effective, fast response, and limited accuracyInternal, External
Thermographic Imaging [27]TemperatureMeasures overall temperature distribution, limited resolution and accuracyExternal
Isothermal Calorimetry [28]TemperatureComplex equipment, poor real-time performanceExternal
Infrared (IR) Thermal Imaging [29]TemperatureGraphic display of temperature distribution, real-time monitoringExternal
Pressure Sensor [30]PressureReal-time monitoring of gas pressure, larger sizeExternal
Load Cell [31]StrainRequires support structure, internal parameters cannot be directly measuredExternal
Strain Gauge [32]StrainUsed for material stress analysis, attached to battery surfaceExternal
X-ray Diffraction (XRD) [33]StrainMaterial discrimination, phase transformation, structural variation, particle size distribution, and lattice sizeExternal
X-ray Photoelectron Spectroscopy (XPS) [34]StrainElemental component, valence variation, and energy shiftsExternal
Digital Image Correlation [35]StrainAcquires surface deformation information, cannot access internal informationExternal
IR Spectroscopy [36]Electrolyte compositionProvides information about the structure of the moleculeExternal
Raman Spectroscopy [37]Electrolyte compositionMeasurement of molecular vibrational modesExternal
Nuclear Magnetic Resonance (NMR) [38]Electrolyte compositionProvides information about the structure of the moleculeExternal
Mass Spectrometry [39]Electrolyte compositionProvides information on the mass and structure of the moleculeExternal
Optical Fiber Evanescent Wave [40]Electrolyte compositionMonitors electrolyte composition, complex sample preparationInternal
Machine Learning Algorithms [32]SOC/SOHData-driven analysis, requires a large number of high-quality dataExternal
Scanning Transmission Electron Microscope (STEM) [41]SoC/SoHMorphological change, element distribution, compositional analysis, and structural changeExternal
Equivalent Circuit Model (ECM) [42]SoC/SoHLimited accuracy, cumulative model errorExternal

2. Battery Degradation Mechanism and Fiber Optic Monitoring Principle

2.1. Battery Principle

Deng et al. from our team designed a variety of special electrode materials and applied them to various new energy storage devices, such as lithium-ion (Li-ion) batteries, sodium-ion batteries, lithium-sulfur batteries, and supercapacitors, which greatly improved the performance of the batteries. In addition, they have systematically studied the interfacial reactions in energy storage systems and elaborated various reaction mechanisms [43,44,45,46,47]. While different battery types undergo unique charging and discharging processes, they fundamentally rely on internal chemical reactions for energy conversion. During the charging phase, an external power supply introduces electrons into the battery, merging them with positive ions within the energy storage material, transitioning the battery from a low-energy state to a high-energy state. Upon discharge, the chemical bonds in the energy storage material break, returning the battery to a low-energy state. This process releases stored electrons and positive ions, supplying energy to external devices. These processes induce alterations in microchemical properties and macroscopic physical parameters, including heat, stress, gas byproducts, and electrolyte solubility, impacting battery performance and cycle life. Currently, operational battery systems predominantly comprise 78% Li-ion batteries, with sodium and lead-acid batteries accounting for 11% and 4%, respectively. Other storage technologies, such as flow batteries, electrochemical capacitors, sodium-ion batteries, and nickel- and zinc-based batteries, collectively contribute to the remaining 7% [48]. Consequently, the majority of reported fiber optic sensing battery monitoring studies have focused on Li-ion batteries. This paper specifically centers on the online monitoring of Li-ion batteries.

2.1.1. Anode Degradation

During the charging and discharging process of Li-ion batteries, several deleterious phenomena occurring at the anode significantly impact the QRL of the battery [49,50,51,52,53,54,55]. These phenomena are primarily observed in the following three aspects:
(1) The formation of a solid electrolyte interface (SEI) layer on the anode surface leads to a decline in conductivity and ion transport rate. When a chemical reaction occurs between the electrolyte and the anode, a SEI layer forms on the anode surface, accompanied by the generation of gases [56,57,58,59,60]. With an increasing number of charging and discharging cycles, the SEI layer thickens on the anode surface due to mechanisms such as the solvent molecules diffusion, cleavage, and side-reaction product accumulation. The SEI layer obstructs contact between the active material and the electrolyte, reducing the electrical conductivity and ion transport rate of the battery, ultimately degrading the QRL. Moreover, under harsh conditions such as high temperature, high current load, and electrode breakage, the growth of the SEI layer may accelerate, leading to a decrease in battery capacity [61,62,63].
(2) Internal stresses within the anode material can result in cracking or fracturing. The uneven embedding or dislodging of Li-ions in the electrode material, causing varying volume changes in different regions, has been observed [64,65]. This volume change induces uneven internal stresses in the electrode material, ultimately leading to electrode cracking and potential fracture. High current loads and extreme temperatures can expedite this phenomenon. As cracks widen on the electrode surface, the SEI layer grows on the newly exposed electrode surface, further amplifying the uneven stress distribution within the battery. Additionally, the reduction reaction generates gases, increasing pressure within the battery, potentially resulting in battery cracking.
(3) Lithium plating occurring on the anode surface poses the risk of causing internal short circuits. This phenomenon induces a series of associated side reactions, including the deposition of lithium metal and lithium dendrite growth. Li-ions undergo a reduction reaction on the anode surface to form lithium metal deposition [60]. Consequently, lithium metal no longer participates in redox reactions, leading to an irreversible loss of battery capacity. Furthermore, the deposited lithium metal extends from the anode surface, forming a tree-like structure known as lithium dendrites. The growth of lithium dendrites has the potential to breach the separator, causing an internal short circuit and triggering thermal runaway in the battery. The formation and evolution of the lithium anode coating are influenced by various factors, such as the electrolyte’s nature, the positive-to-negative electrode capacity ratio, the operating temperature, and the charging rate.

2.1.2. Cathode Degradation

During battery operation, the cathode also undergoes changes detrimental to the QRL of the battery, such as loss of active material, cathode cracking, and cathode electrolyte interface (CEI) formation [66,67,68,69,70].
(1) The loss of active material from the cathode represents a prevalent aging process. Transition metals such as nickel, manganese, cobalt, and iron in the cathode may dissolve in the electrolyte [69], leading to a decline in battery capacity and performance. This phenomenon is particularly accelerated under conditions of high temperature and frequent charging and discharging cycles.
(2) Cathode cracking can occur due to charge insertion or extraction and gas generation. Specifically, the uneven insertion and extraction of lithium ions during charging and discharging can cause irreversible phase transitions in the cathode structure, resulting in internal stresses that crack the cathode [71]. This essentially reduces the amount of acceptable lithium ions in the cathode, resulting in diminished battery capacity. Additionally, gases generated within the battery contribute to cathode cracking; at elevated temperatures, metal oxides may lose oxygen, and under high pressures, the electrolyte may decompose, producing gases. The accumulation of these gases raises the internal air pressure within the battery, potentially leading to cathode cracking.
(3) Similar to the anodic SEI layer, the CEI layer is mainly generated by the chemical reaction between the cathode and the electrolyte. However, due to the higher cathode voltage, the volume of the CEI layer is considerably smaller than that of the SEI layer. Its formation results in a reduction in active materials, such as lithium, uneven pressure leading to alterations in the cathode structure, and even the development of cracks. Particularly under conditions of high voltage and high state of charge (SOC), these issues become more severe, significantly impacting the QRL of the battery.

2.2. Fiber Optic Sensing Principle

The FBG sensor is essentially an optical wavelength selector that utilizes periodic changes in RI along an optical fiber to diffract and reflect light. When external factors such as temperature, strain, or pressure impact the fiber grating, the periodic RI of the grating changes, leading to the reflection or diffraction of light at a specific wavelength. FBG sensors have a wide range of applications in fields such as structural health monitoring, oil and gas pipeline surveillance, aerospace, and the medical industry [18,72,73,74,75,76,77,78,79,80,81,82,83,84,85].

2.2.1. Fiber Bragg Grating

Fiber gratings are formed by interferential irradiation of optical fibers by laser or ultraviolet light beams [86,87,88]. As shown in Figure 1, when broadband light is incident on a fiber grating sensor, specific wavelengths of light are reflected while others are transmitted.
The wavelength of the reflected light is so-called the Bragg wavelength, which is proportional to the period of the grating and the effective RI of the fiber. It can be expressed as:
λ B = 2 n n e f f Λ ,
where n e f f denotes the effective RI of the optical fiber, λ B denotes the Bragg wavelength, and Λ denotes the grating period. When a FBG sensor is subjected to temperature and/or stress, its period and equivalent refraction change, resulting in a change in Bragg wavelength. The relationship between Bragg wavelength change and temperature/strain can be expressed by the following equation:
Δ λ B λ B = ( α + β ) Δ T + 1 ρ e Δ ε ,
in which
α = Λ / Λ T , β = n eff / n eff T , ρ e = n e f f 2 2 ( 1 ν ) p 12 ν p 11 ,
where Δ T is the change of the FBG’s temperature, α denotes the thermal expansion coefficient, β denotes the thermo-optic coefficient, Δ ε is the FBG’s strain, ρ e denotes the effective optoelastic coefficient of the fiber core, ν denotes the Poisson’s ratio, and p 11 and p 12 denote the Pockel’s coefficients of the strain optical tensor [89]. Therefore, FBG sensors can be used to detect temperature and/or strain. The mainstream spectrum analysis device is shown in Figure 2. The system consists of a light source, a circulator, a spectral analysis device, a photodetector, and a data acquisition card. The light signal from the light source passes through the circulator and enters the optical fiber with the FBG sensor. The FBG sensor reflects the light back to the circulator and is spectrally decomposed. The photodetector measures the light intensity of different frequencies, which is then converted to 16-bit electrical signals by the data acquisition card. Finally, the signals are processed by a computer.

2.2.2. Tilted Fiber Bragg Grating

Unlike conventional FBG, Tilted FBG (TFBG) features a specific angle Bragg grating tilted with respect to the optical axis of the fiber [90,91,92,93]. This tilt angle induces coupling between the forward-propagating fiber core modes and the cladding modes, resulting in the emergence of multiple closely spaced resonance peaks in the transmission spectrum of the sensor, as illustrated in Figure 3.
The resonant wavelengths of the core modes exhibit high sensitivity to a broad range of physical parameters (temperature, strain, pressure, etc.) but remain insensitive to changes in the external RI. On the other hand, the resonant wavelength of the cladding mode is highly sensitive to variations in the external RI. Consequently, the resonant wavelength of the cladding mode shifts in response to changes in the surrounding refractive index. The mode wavelengths λ c l ( i ) coupled to the cladding can be expressed as:
λ c l ( i ) = n e f f , c o + n e f f , c l ( i ) Λ cos θ ,
where λ c l ( i ) is the wavelength of the i th cladding mode, and n e f f , c o and n e f f , c l ( i ) are the effective RI of the fiber core mode and the i th cladding mode, respectively. θ is the tilted angle between the grating planes and the cross-section of the fiber.

3. Online Monitoring of Battery Degradation

FBG sensors have garnered significant attention in battery monitoring applications since their initial use in 2013 [94]. Originally employed to monitor the real-time surface temperature distribution, surface strain, and SOC of batteries [64,95,96,97,98,99,100,101,102], their monitoring capabilities have subsequently expanded to include temperature, strain, pressure, and chemical reaction processes within the battery.

3.1. Monitoring Chemical Formulae and Stereo Structures

Traditional methods for characterizing the microstructure and crystal structure of battery materials involved techniques such as STEM, Scanning Electron Microscopy (SEM), and XRD to analyze the loss of Li-ion and the extent of electrode fracture and cracking [41,103,104,105,106]. EIS was employed to evaluate the electrochemical impedance of the battery, providing insights into the growth of the SEI layer [107]. Compositional analysis of battery materials was performed using NMR, mass spectrometry, IR spectroscopy, and Raman spectroscopy, offering molecular-level insights into the state of electrodes and electrolytes [36,37,38,39].
Different fiber optic sensors enable a variety of spectroscopic analysis techniques, including SPR spectroscopy, absorption spectrum, IR spectroscopy, and Raman spectroscopy. These spectral analysis techniques are safe and rapid methods that have been widely used to monitor the chemical composition and evolution of various batteries.
Fiber optic evanescent wave sensors (FOEWS) are used to analyze the absorption spectra of the electrodes to monitor the changes in the material inside the battery. Its transmittance intensity is affected by the lithium content of the graphite anode, which is directly related to the SOC of the Li-ion battery. Therefore, FOEWS can be used to estimate the SOC of the battery. Further, a decrease in the amount of change in its transmittance indicates a decrease in the amount of change in the lithium content of the graphite, which implies that the capacity of the Li-ion battery is degraded. Therefore, the magnitude of FOEWS transmittance can also decode the state of health (SOH) of the battery [108].
Silicon-free background Raman spectroscopic measurements of various electrolyte components were conducted by incorporating a hollow-core fiber optic sensor into a Li-ion pouch battery. The aim was to undertake a thorough examination of the chemical degradation mechanism of the electrolyte. Spectroscopic analysis revealed changes in the ratio of carbonate solvents and electrolyte additives corresponding to variations in battery voltage. Moreover, the hollow-core fiber optic sensor showcased its potential for monitoring lithium ion dissolution dynamics [37]. Hollow-core fiber optics offer solutions to several limitations associated with silica fiber optic probes in monitoring nearby electrolyte compositions. These limitations include relatively weak Raman signals, short light-matter interaction lengths (largely confined to the fiber tip), and sensitivity issues induced by silica, while simultaneously eliminating silica-generated Raman signals.
Fiber optic IR spectroscopy has been employed to monitor the insertion and removal of Na-ions from electrodes, as well as the phase transitions experienced by materials inside the cell during cycling. Gervillié-Mouravieff et al. implemented operando IR fiber evanescent wave spectroscopy using sulfur-based (sulfide, selenide, and telluride) glass fibers with a transmission window in the range of 3 to 13 μ m [109].
Localized electrochemical events at the electrode interface can be screened by monitoring changes in the SPR spectra of a TFBG sensor with a gold film. In 2022, Wang et al. [110] successfully quantified ion transport kinetics and electrolyte–electrode interactions at the electrode surface of a battery using this sensor, as shown in Figure 4.
The sensor, with its longer penetration depth and propagation length, allows for the real-time monitoring of electrochemical kinetics without interfering with the normal operation of the battery. Experiments conducted on a zinc-ion water battery illustrated the visualization of a two-step ion insertion mechanism at the MnO2 cathode during the discharge process, distinguishing the intercalation processes of H+ and Zn2+. Additionally, it was demonstrated that a thin layer of poly (3,4-ethylenedioxythiophene) coated on the surface of the electrodes improves battery capacity and cycle stability.
In 2024, Han et al. [111] successfully embedded a TFBG sensor onto the electrode surface of a lithium battery, enabling the monitoring of mass transfer kinetics and lithium dendrite growth at the anode nanoscale interface. In addition, it was demonstrated that the artificial SEI layer can reduce the substance concentration gradient on the anode surface, which helps to inhibit the generation of lithium dendrites, notably based on the ionic conductor artificial SEI layer.
Traditional techniques, while capable of accurately characterizing the internal state of a battery, require expensive and complex equipment that cannot be monitored in real time.

3.2. Monitoring Physical Phenomena of Batteries

The microscale reactions, such as lithium ion insertion/precipitation, volume expansion, gas generation, and dendrite formation, inside the electrode particles can be manifested in the macroscale as regular stress evolution, temperature changes, etc. The loss of battery materials and the insertion and detachment of ions can lead to changes in the internal stress of the battery and even lead to battery rupture. The internal battery strain can provide information about the change of battery thickness and the evolution of electrode stress [112]. The polarization and exotherm of chemical reactions result in internal temperatures significantly higher than external temperatures [113,114], offering a more reflective measure of the charging and discharging state of the battery.
In 2013, Yang et al. [94] conducted investigations on Li-ion button and cylindrical batteries, achieving real-time temperature monitoring by installing FBG sensors on the battery surface. Comparative experiments with thermocouple sensor monitoring demonstrated that FBG sensors can accurately track temperature changes in Li-ion batteries under normal and excessive charging and discharging conditions. They exhibited excellent thermal response performance during battery charging and discharging, providing a temperature resolution of 0.1 °C and a sensitivity of 10 pm/°C, making them a viable alternative to thermocouple sensors.
In 2016, Novais et al. [13] positioned two FBG sensors inside and outside Li-ion pouch cell to monitor their temperature changes, as shown in Figure 5.
The results revealed that internal FBG sensors recorded temperature variations of up to 2 °C between the two areas, while external FBG sensors exhibited temperature variations of only 0.2 °C. In the center and electrode areas of the cell, external temperature measurements showed minimal variations, approximately 1.5 ± 0.1 °C, whereas corresponding internal temperature variations in the center area of the cell were 4.0 ± 0.1 °C, and internal temperatures varied by 4.7 ± 0.1 °C. These temperature fluctuations were correlated with current magnitude, with the highest temperature peaks occurring at the end of charging and discharging. Additionally, the influence of strain on temperature measurements was negligible due to the pouch cell’s very small thickness.
In 2018, Amietszajew et al. [115] utilized an FBG sensor to evaluate the internal temperature of cylindrical Li-ion battery. The internal temperature increased by 5 °C compared to the external temperature. To eliminate the effect of strain on the temperature measurement, an aluminum loose sleeve was used to protect the FBG sensor encapsulated with a polyamide coating. In addition, fluorinated ethylene propylene (FEP) heat shrinkable tubing was used to prevent the aluminum tubing and polyamide coating from interfering with the electrolyte, as shown in Figure 6a.
The results showed that the battery could safely withstand a maximum charging current 6.7 times higher than the manufacturer’s specified value. As a result, a fast-charging protocol was developed to improve charging efficiency, reducing charging time by more than five times while ensuring the continued safe operation of the battery.
In the same year, Fleming et al. [116] of the same research group used four FBG sensors to monitor the internal temperature distribution of a cylindrical Li-ion battery. These sensors were threaded through a custom aluminum tube coated with FEP into the interior of the battery, as shown in Figure 6b. The results show that in the region close to the anode and cathode, the temperature difference from the surface of the battery is as high as 6 °C during discharge and 3 °C during charging. In addition, the corrosion resistance of the FBG sensor material to the electrolyte was demonstrated, as well as the long term stability of the FBG sensors during the battery cycling process.
In 2022, Liu et al. [117] employed a femtosecond laser FBG sensor to monitor the operating temperature inside a cylindrical Li-ion battery. The integration scheme of the FBG with a thermocouple sensor into the battery is depicted in Figure 7.
The FBG sensor and a thermocouple were inserted inside the battery, while another thermocouple was positioned outside the battery as a temperature reference. The results demonstrated that the FBG sensor and the thermocouple sensor exhibited similar temperature response curves during charge/discharge cycling at different rates (0.5 C, 1 C, and 2 C). It is noteworthy that the FBG sensor exhibited a smaller baseline change. The internal cell temperature detected by the FBG sensor was 0.96 °C higher than the external temperature during the 0.5 C cycle, 1.78 °C higher during the 1 C cycle, and 3.78 °C higher during the 2 C cycle. Additionally, the reflective wavelength of the FBG sensor showed minimal change over the 2 MPa internal pressure range, indicating that the internal pressure change had a negligible effect on temperature.
In 2023, Wu et al. [15] employed an FBG array film (FBGAF) for assessing the internal temperature of a hard-shelled Li-ion battery. The FBGAF integrates a flexible thin-film sensor with five FBG sensors, as illustrated in Figure 8. In experiments with pulse discharge rates of 30 C, the internal temperature increased by approximately 13–15 °C, reaching a maximum temperature of 50 °C. Concurrently, the external temperature increased by about 10 °C, reaching a maximum temperature of 45 °C. Notably, the FBGAF were able to resist corrosion of the electrolyte solution for a long period of time.
In 2016, Bae et al. [118] applied FBG sensors by pasting and implanting them on Li-ion battery anodes to monitor strain changes, as depicted in Figure 9. The pasted FBG sensors measured longitudinal strain, while the implanted FBG sensors measured both longitudinal and transverse strain. The results revealed that during charging, electrode expansion caused the peak wavelength to shift towards longer wavelengths, and during discharging, electrode contraction caused the peak to shift towards shorter wavelengths.
In 2016, Ganguli et al. [119] utilized two FBG sensors to measure internal strain inside a Li-ion pouch battery for estimating SOC and SOH. In static cycling tests with fixed charging and discharging rates, the estimated SOC error did not exceed 1%. During dynamic cycling tests involving different charge/discharge rates, the estimated SOC error remained below 2.5%. Furthermore, they developed a method to estimate SOH with an error of no more than 1.1%.
In 2022, Blanquer et al. [120] utilized FBGs and external force sensors to monitor stress changes inside and outside a Li-ion battery, respectively. Throughout battery cycling, changes in the fiber Bragg wavelength reflected stress variations and exhibited correlation with voltage. Importantly, in symmetric all-solid-state Li-ion batteries, external force sensors faced limitations in monitoring stress changes outside the battery, particularly those occurring in the electrodes. In contrast, FBG is not constrained by monitoring electrode stress due to its small size.
In 2022, Miao et al. [70] integrated FBG sensors into the positive electrode of a Li-ion pouch battery to monitor stress changes. Through an exploration of various sulfur embedding and releasing mechanisms, they discovered that stress changes are not only associated with volume alterations but also influenced by material properties. Specifically, under the solid–solid mechanism, the polyacrylonitrile (PANS) cathode material exhibited significant stress changes, whereas under the solid–liquid–solid mechanism, the ketjen black/sulfur (KB/S) cathode material displayed a smaller stress change.
In 2022, Unterkofler et al. [121] explored encapsulation methods for FBG sensors used within the Li-ion battery. Various encapsulation methods for strain relief were compared, including polyether ether ketone (PEEK) with a single-point adhesive, fused silica tubes with a polyimide coating, fused silica tubes without a polyimide coating, and fused silica tubes with a two-point adhesive but without a polyimide coating. The results indicated that the encapsulation method using fused silica tubes with polyimide coatings is user-friendly, provides effective fiber protection, has a smaller diameter, and exhibits rapid response to temperature changes.
In 2017, Fortier et al. [24] employed an FBG sensor to monitor the temperature and strain inside a Li-ion coin cell. To safeguard the positive electrode from damage, two isolation layers were added above and below the embedded FBG sensor, as illustrated in Figure 10a–d.
The results revealed a temperature difference of 10 °C between the inside and outside of the cell at a charge/discharge rate of C/20. The small size of the cell contributed to minimal strain changes inside the cell.
In 2019, Nascimento et al. [122] embedded hybrid sensors consisting of FBG sensors and FP cavities at the top, middle, and bottom of the inside of a Li-ion pouch battery to monitor strain and temperature changes, as shown in Figure 11.
The simultaneous measurement of strain and temperature changes can be expressed by the following equation:
Δ ε Δ T T = K F P T K F B G T K F P ε K F B G ε K F P ε K F B G T K F P T K F B G ε Δ λ F B G Δ λ F P ,
where K F B G T and K F B G ε represent the temperature and strain sensitivity coefficients of the FBG sensor, respectively. Δ λ F B G states the wavelength shift of FBG sensors. Similarly, K F P T , K F P ε represent the temperature and strain sensitivity coefficients of the FP cavity, respectively. Δ λ F P represents the wavelength shift of the FP cavities. The results show that the FBG sensor mounted at the bottom of the battery is the most sensitive to strain changes at 65.0 ± 0.1 μ ε , and the one in the middle is the most sensitive to temperature changes at 3.3 ± 0.1 °C.
In 2022, Xi et al. [112] positioned two FBG sensors within a Li-ion coin cell to meticulously observe temperature and stress variations. As shown in the Figure 12, one FBG sensor nested inside a quartz capillary was subjected to temperature only, while the other was subjected to both temperature and strain.
The findings revealed a maximum temperature alteration of 0.42 °C and a maximum strain change of 11.5 μ ε . Notably, the strain variations exhibited greater magnitude during the initial two charging and discharging cycles and diminished in subsequent cycles. The existence of strain within the cell was substantiated by the observation of lithium dendrites through SEM at the conclusion of the charging and discharging processes.
In 2018, Lao et al. [123] utilized a TFBG sensor with an attached gold film to monitor the charging and discharging processes of supercapacitors. The results showed that the SPR spectral response was closely related to the charge stored in the supercapacitor. Notably, the SPR spectral response demonstrated a stable and distinct reflection of multiple charge/discharge cycles in supercapacitors.
The aforementioned alterations in physical parameters, such as temperature and strain induced by battery chemistry, may not precisely portray the authentic state of the battery. Temperature variations can be influenced by factors like battery design and operating environment, while strain may be subject to various elements, including material phase transitions and battery structure. Certain materials, such as lithium titanate and lithium iron phosphate, exhibit minimal or even negligible strains. Consequently, methodologies reliant solely on monitoring these physical parameters might not offer an accurate determination of the battery’s state. Fortunately, additional phenomena during battery operation, such as variations in electrolyte RI, pH fluctuations, and the generation of gases due to battery side reactions, present avenues for acquiring more precise and detailed insights into a battery’s QRL.

3.3. Monitoring Compounds and Gas Products

Accompanying substances in battery chemistry serve as key information for deciphering the internal operational status of the battery. High temperatures can prompt metal oxides to shed oxygen molecules, and elevated pressure can cause electrolytes to decompose, resulting in gas production. If the gas generation rate surpasses the diffusion rate, it may lead to battery cracking. Gas generation can also occur during the initial formation of the SEI layer. Simultaneously, redox reactions may alter the electrolyte’s solubility. FBG sensors prove instrumental in monitoring these gas byproducts and electrolyte concentrations, facilitating the analysis of SEI layer formation and ion transport kinetics.
In 2020, Huang et al. [124] utilized FBG sensors integrated into conventional single-mode fiber (SMF) or microstructure optical fiber (MOF) to simultaneously monitor temperature and gas pressure inside the battery, as shown in Figure 13a.
Two FBG sensors were positioned in a 0.8 mm diameter hole at the battery’s center to mitigate the impact of internal strain. The hole was subsequently sealed with epoxy resin, as shown in Figure 13b. The operando calorimetry method transforms temperature into quantifiable thermal events, enabling the tracking of SEI layer formation and battery life. Temperature and gas pressure can be decoupled using the following equation:
Δ P = k T , SMF Δ λ B , MOF k T , MOF Δ λ B , SMF k T , SMF k P , MOF k T , MOF k P , SMF , Δ T = Δ λ B , SMF k P , SMF Δ P k T , SMF ,
where k P , SMF = −0.3 pm/bar and k T , SMF = +10 pm/°C represent the pressure sensitivity and the temperature sensitivity of the SMF sensor, respectively. k P , MOF = −2.7 pm/bar and k T , MOF = +10 pm/°C represent the pressure sensitivity and the temperature sensitivity of the MOF sensor, respectively. λ B , MOF and Δ λ B , SMF represent the wavelength shift of the MOF-FBG sensor and SMF-FBG sensor, respectively.
In 2021, Desai et al. [125] integrated an FBG sensor with a MOF to monitor the heat and pressure within a cell, aiming to optimize the electrolyte formulation for sodium-ion batteries. The study investigated the electrolyte degradation rate in three batteries utilizing the same electrolyte with the addition of various electrolyte additives. The three batteries included Na3V2(PO4)2F3 (NVPF)/hard carbon (HC) full-cell, NVPF/NVPF symmetric, and HC/HC symmetric batteries. The electrolyte composition comprised ethylene carbonate vinyl acetate (EC)/propylene carbonate (PC)/dimethyl carbonate (DMC). The electrolyte additives were formulated as 0.5 wt.% sodium oxalato (difluoro) borate (NaODFB), 3 wt.% vinylene carbonatevinyl (VC), 3 wt.% succinonitrile (SN), and 0.2 wt.% VC and 0.2 wt.% tris-trimethylsilylphosphite (TMSPi). The findings revealed that cells with additives, particularly in the NVPF electrodes, exhibited a lower rate of electrolyte degradation and considerably reduced heat and gas generation compared to cells without additives.
In 2023, Mei et al. [126] devised a fiber optic sensor comprising an FBG and an FP interferometer (FPI) to elucidate the thermal runaway mechanism and its progression in three distinct SOC cases (100% SOC, 50% SOC, and 0% SOC). Cells with 100% SOC exhibited thermal runaway internal temperatures reaching up to 510 °C, with a maximum temperature difference between the interior and surface exceeding 180 °C. The thermal runaway behavior of the 50% SOC cell closely resembled that of the 100% SOC cell, registering an internal temperature of 440 °C. Conversely, the 0% SOC cell displayed no thermal runaway, reaching a maximum internal temperature of 330 °C. The study demonstrated that the FBG-FPI exhibited exceptional resistance to high temperatures during the entire thermal runaway phase.
In 2019, Nedjalkov et al. [127] employed an innovative FBG sensor for monitoring the Li-ion pouch battery, incorporating an additional optical waveguide embedded in the fiber cladding. As illustrated in Figure 14, the first FBG sensor is integrated into the fiber core, while the second FBG sensor is integrated into the optical waveguide at the fiber’s edge.
This design enhances the sensor’s sensitivity to changes in the electrolyte solution’s RI. Experimental results demonstrate the sensor’s capability to detect subtle changes in electrolyte properties and accurately characterize battery capacity degradation. It has no significant effect on battery performance, although traces of pressure by the sensor are detected on the electrodes. Notably, the sensor exhibited early detection of thermal runaway in abuse tests.
In 2021, Huang et al. [90] utilized a TFBG sensor inserted into a hollow cylindrical Li-ion cell to decipher its internal temperature and electrolyte RI. Due to the TFBG’s immunity to the strain within the battery, its spectral changes are solely influenced by variations in temperature and RI. The wavelength interval between the resonance wavelength and the Bragg resonance provides RI information. Moreover, monitoring the amplitude peaks of the TFBG cladding mode enables the tracking of electrolyte turbidity, offering valuable insights into the formation process of the SEI layer.
Compared to the first two types of detection methods, monitoring the chemical reaction’s accompanying substances provides more accurate and real-time insights into the SOC, SOH, and Remaining Useful Life (RUL) of the battery. However, challenges persist in decoupling the electrolyte RI from other measured quantities, such as barometric pressure and stress; demodulating optical signals to extract the measured quantities; and effectively monitoring multi-battery configurations.

3.4. FBG Measurement Accuracy and Sensitivity

The monitoring of the internal parameters of the battery was achieved based on FBG sensors. Table 2 shows a summary of some FBG sensors used to monitor different parameters of the battery (temperature, strain, pressure, electrolyte RI, and SOC). Table 2 illustrates that the FBG sensing systems developed by Novais et al. [13], Nascimento et al. [122], Huang et al. [124], and Desai et al. [125] exhibit the highest temperature accuracy of 0.1 °C. Furthermore, Nascimento et al. [122]’s FBG sensing system demonstrates the highest temperature sensitivity at 40 pm/°C. Nascimento et al. [122] established the peak strain accuracy and sensitivity of the FBG sensor at 0.1 μ ε and 2.2 pm/ μ ε , respectively. Huang et al. [124] reported the top pressure measurement accuracy and sensitivity of the FBG sensor as 0.14 bar and −0.3 pm/bar. The highest RI measurement accuracy and sensitivity for FBG sensors were determined to be 6 × 10−5 RIU and −18 nm/RIU, respectively, by Huang et al. [90]. While these studies achieve notable precision and sensitivity for individual parameters, simultaneous high accuracy and sensitivity for multi-parameter measurements remain challenging due to the complexities associated with multi-parameter decoupling.

4. Challenges and Outlooks

FBG sensing technology for battery applications is rapidly advancing from conventional laboratory measurements towards practical field monitoring applications. However, the future development of FBG sensors for internal battery monitoring encounters several challenges.
Firstly, the design and packaging of FBG sensors for internal battery applications confront complex technical requirements. The variable and intricate operating environment within the battery, coupled with the delicate nature of FBGs, necessitates stable sensor operation. Optimizing fiber material, structure, and surface metal plasma coating becomes imperative to withstand the harsh chemical environment within batteries [128,129], preventing electrolyte leakage, and improving the QRL of the battery [130]. Our fiber optic grating sensor design, manufacturing, and packaging technologies developed for the construction, aerospace, robotics, chemical, entertainment, biological, and pharmaceutical industries may be transferable to internal and external battery monitoring [131,132,133,134,135,136,137].
Secondly, accurately parsing FBG sensor data used for battery assessment is a major challenge [70,110,121,124,125]. (1) Due to the sensitivity of fiber optic sensors to multiple parameters, such as temperature and stress, achieving decoupling and precise measurement of multidimensional parameters is crucial for accurately evaluating the health status of batteries [138,139,140,141]. This includes addressing the coupling of temperature and strain, electrolyte RI, and other influencing factors, such as the solid electrolyte layer versus the electrochemical interfacial layers. (2) Effective signal processing techniques can significantly reduce the impact of noise on optical signals, thereby enhancing the accuracy of battery condition measurements [142,143,144,145,146,147,148]. For instance, the Activation Function Dynamic Averaging (AFDA) algorithm outperforms the Frequency Domain Dynamic Averaging (FDDA) algorithm by processing signals eight times faster and improving the SNR by 3.7 dB independently, and by 10.8 dB when combined with MA-MD [143]. Additionally, a nonlinear distortion correction algorithm can rectify charge coupled device (CCD) measurement spectra, eliminating errors that may arise during various Time of INTegration (TINT) measurements [142]. Furthermore, a fiber grating filter is incorporated to enhance the overall signal processing capabilities [144]. (3) In addition, advanced algorithms and models based on a large number of monitoring data are crucial for the real-time evaluation and prediction of battery SOC, SOH, and RUL in fiber optic sensing battery monitoring red[149,150,151,152,153,154]. This requires the combination of multi-dimensional parameters inside and outside the monitored battery with technologies such as machine learning and artificial intelligence to achieve a battery level battery management system (BMS) and fault diagnosis. Our recently proposed series of advanced fiber optic signal processing methods [155,156,157,158,159] is capable of eliminating various kinds of noises in practice, such as electrochemical noises, road noises, wind noises, and auxiliary system noises [160,161]. This helps in fiber optic sensing multiparameter decoupling; signal signature identification; and evaluation with battery SOC, SOH, and RUL.
Finally, the cost of equipment and standardization of production also limit the application of FBG sensors in battery monitoring. (1) Standardizing the integration of FBG sensors during the battery manufacturing process ensures their seamless incorporation into the battery structure. (2) The cost of optical sensing does not increase linearly with the number of batteries because of multiplexing, which is different from the cost of using electrical sensing. (3) The establishment of uniform standards and specifications is crucial to ensuring the applicability and reliability of different types of FBG sensors across various battery systems. According to a cost analysis forecast done by Alamgir in 2016 [162], fiber optic sensing BMSs are expected to compete with traditional electrical sensing BMSs.
In short, fiber optic sensing battery monitoring technology includes fiber optic design, fabrication, installation, signal processing, physical field analysis of monitoring objects, big data analysis, and artificial intelligence battery health assessment. Although there are still some difficulties and challenges, fiber optic sensors will play an important role in future development. The application of fiber optic sensors can not only guarantee the safe operation of batteries but also provide the necessary data support for the optimization and development of new high energy density batteries. Therefore, further research and application of fiber optic sensor technology is of great significance to promote the development of battery technology.

5. Discussion

This paper provides a comprehensive review and analysis of various sensing technologies, with a particular focus on the application of FBG technology in monitoring batteries. The strengths and limitations of different detection technologies are carefully examined. Assessing parameters crucial to battery health, current technologies can be categorized into:
(1) Traditional monitoring technologies, while accurate, face limitations in real-time monitoring due to the need for intricate sample preparation, complex signal processing, and expensive equipment.
(2) Fiber optic sensing technology, while capable of monitoring physical parameters related to battery status in real time, faces challenges in achieving accurate monitoring. Its effectiveness may vary under different conditions of use.
(3) Fiber optic sensing technology emerges as a promising avenue for monitoring chemical characteristics such as pH value, RI, and gas emissions in batteries. It holds the potential to overcome the drawbacks of the previous methods, enabling precise and real-time assessments of battery performance.
Therefore, the primary challenge in current battery monitoring technology lies in achieving real-time and accurate detection of SOH, SOC, and RUL. A promising approach involves the real-time monitoring of battery material properties, contingent upon establishing explicit monitoring parameters and physical models of the battery state. Despite facing challenges, such as standardized packaging, temperature–strain coupling for fiber optic sensing, noise reduction in signal processing, and the integration of multiparameter and artificial intelligence models, FBG technology is expected to comprehensively enhance the QRL of batteries. This optimism is grounded in the unique advantage of FBG, as evidenced by its pivotal role in advancing the field of battery condition monitoring [163,164,165].

Author Contributions

Conceptualization, K.Y. and J.H.; methodology, K.Y. and J.H.; software, W.C. and D.D.; validation, K.Y. and Q.W.; formal analysis, W.C. and J.H.; investigation, K.Y.; data curation, K.Y.; writing—original draft preparation, K.Y.; writing—review and editing, W.C.; visualization, K.Y.; and supervision, W.C. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported in part by the Natural Science Foundation of Fujian Science and Technology Plan under Grant (2022J01824) and the National Natural Science Foundation of China (22172062, 22379051).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
XRDX-ray Diffraction
STEM     Scanning Transmission Electron Microscope
IRInfrared
NMRNuclear Magnetic Resonance
RIRefractive Index
CVCyclic Voltammetry
CCCVConstant Current Constant Voltage
EISElectrochemical Impedance Spectroscopy
pHPotential of Hydrogen
QRLquality, reliability and life
MZMach–Zehnder
FBGFiber Bragg Grating
SPRSurface Plasmon Resonance
XPSX-ray Photoelectron Spectroscopy
SEMScanning Electron Microscope
ECMEquivalent Circuit Model
Li-ionlithium-ion
SEISolid Electrolyte Interface
CEICathode Electrolyte Interface
SOCState of Charge
TFBGTilted Fiber Bragg Grating
SOHState of Health
FOEWSFiber optic evanescent wave sensors
FEPFluorinated Ethylene Propylene
FBGAFFiber Bragg Grating Array Film
PANSPolyacrylonitrile
KB/SKetjen Black/Sulfur
PEEKPolyether Ether Ketone
FPFabry–Perot
SMFSingle Mode Fiber
MOFMicrostructure Optical Fiber
NVPF Na 3 V 2 ( PO 4 ) 2 F 3
HCHard Carbon
ECEthylene Carbonate
PCPropylene Carbonate
DMCDimethyl Carbonate
NaODFBNamely Sodium Oxalato (Difluoro) Borate
VCVinylene Carbonate
SNSuccinonitrile
TMSPiTris-trimethylsilylphosphite
FPIFabry–Perot Interferometer
RULRmaining Useful Life
AFDAActivation Function Dynamic Averaging
FDDAFrequency Domain Dynamic Averaging
CCDCharge Coupled Device
TINTTime of INTegration
BMSBattery Management Systems

References

  1. Dehghani-Sanij, A.R.; Tharumalingam, E.; Dusseault, M.B.; Fraser, R. Study of Energy Storage Systems and Environmental Challenges of Batteries. Renew. Sustain. Energy Rev. 2019, 104, 192–208. [Google Scholar] [CrossRef]
  2. Kebede, A.A.; Coosemans, T.; Messagie, M.; Jemal, T.; Behabtu, H.A.; Van Mierlo, J.; Berecibar, M. Techno-Economic Analysis of Li-ion and Lead-Acid Batteries in Stationary Energy Storage Application. J. Energy Storage 2021, 40, 102748. [Google Scholar] [CrossRef]
  3. Xu, H.; Shen, M. The Control of Lithium-ion Batteries and Supercapacitors in Hybrid Energy Storage Systems for Electric Vehicles: A Review. Int. J. Energy Res. 2021, 45, 20524–20544. [Google Scholar] [CrossRef]
  4. Graham, J.D.; Rupp, J.A.; Brungard, E. Lithium in the Green Energy Transition: The Quest for Both Sustainability and Security. Sustainability 2021, 13, 11274. [Google Scholar] [CrossRef]
  5. Grey, C.P.; Hall, D.S. Prospects for Lithium-Ion Batteries and beyond—A 2030 Vision. Nat. Commun. 2020, 11, 6279. [Google Scholar] [CrossRef]
  6. Fan, X.; Liu, B.; Liu, J.; Ding, J.; Han, X.; Deng, Y.; Lv, X.; Xie, Y.; Chen, B.; Hu, W.; et al. Battery Technologies for Grid-Level Large-Scale Electrical Energy Storage. Trans. Tianjin Univ. 2020, 26, 92–103. [Google Scholar] [CrossRef]
  7. Mukherjee, S.; Albertengo, A.; Djenizian, T. Beyond Flexible-Li-Ion Battery Systems for Soft Electronics. Energy Storage Mater. 2021, 42, 773–785. [Google Scholar] [CrossRef]
  8. Apa, L.; D’Alvia, L.; Del Prete, Z.; Rizzuto, E. Battery Energy Storage: An Automated System for the Simulation of Real Cycles in Domestic Renewable Applications. In Proceedings of the 2023 IEEE 13th International Workshop on Applied Measurements for Power Systems (AMPS), Bern, Switzerland, 27–29 September 2023; pp. 1–6. [Google Scholar] [CrossRef]
  9. Surya, S.; Rao, V.; Williamson, S.S. Comprehensive Review on Smart Techniques for Estimation of State of Health for Battery Management System Application. Energies 2021, 14, 4617. [Google Scholar] [CrossRef]
  10. Zou, B.; Zhang, L.; Xue, X.; Tan, R.; Jiang, P.; Ma, B.; Song, Z.; Hua, W. A Review on the Fault and Defect Diagnosis of Lithium-Ion Battery for Electric Vehicles. Energies 2023, 16, 5507. [Google Scholar] [CrossRef]
  11. Li, R.; Li, W.; Singh, A.; Ren, D.; Hou, Z.; Ouyang, M. Effect of External Pressure and Internal Stress on Battery Performance and Lifespan. Energy Storage Mater. 2022, 52, 395–429. [Google Scholar] [CrossRef]
  12. Pradhan, S.K.; Chakraborty, B. Battery Management Strategies: An Essential Review for Battery State of Health Monitoring Techniques. J. Energy Storage 2022, 51, 104427. [Google Scholar] [CrossRef]
  13. Novais, S.; Nascimento, M.; Grande, L.; Domingues, M.; Antunes, P.; Alberto, N.; Leitão, C.; Oliveira, R.; Koch, S.; Kim, G.; et al. Internal and External Temperature Monitoring of a Li-Ion Battery with Fiber Bragg Grating Sensors. Sensors 2016, 16, 1394. [Google Scholar] [CrossRef]
  14. Badar, M.; Lu, P.; Wang, Q.; Boyer, T.; Chen, K.P.; Ohodnicki, P.R. Real-Time Optical Fiber-Based Distributed Temperature Monitoring of Insulation Oil-Immersed Commercial Distribution Power Transformer. IEEE Sens. J. 2021, 21, 3013–3019. [Google Scholar] [CrossRef]
  15. Wu, Y.; Long, X.; Lu, J.; Zhou, R.; Liu, L.; Wu, Y. Long-Life in-Situ Temperature Field Monitoring Using Fiber Bragg Grating Sensors in Electromagnetic Launch High-Rate Hardcase Lithium-Ion Battery. J. Energy Storage 2023, 57, 106207. [Google Scholar] [CrossRef]
  16. Nascimento, M.; Ferreira, M.S.; Pinto, J.L. Real Time Thermal Monitoring of Lithium Batteries with Fiber Sensors and Thermocouples: A Comparative Study. Measurement 2017, 111, 260–263. [Google Scholar] [CrossRef]
  17. Li, Y.; Wang, W.; Yang, X.-G.; Zuo, F.; Liu, S.; Lin, C. A Smart Li-Ion Battery with Self-Sensing Capabilities for Enhanced Life and Safety. J. Power Sources 2022, 546, 231705. [Google Scholar] [CrossRef]
  18. Riza, M.A.; Go, Y.I.; Harun, S.W.; Maier, R.R.J. FBG Sensors for Environmental and Biochemical Applications—A Review. IEEE Sens. J. 2020, 20, 7614–7627. [Google Scholar] [CrossRef]
  19. Han, G.; Yan, J.; Guo, Z.; Greenwood, D.; Marco, J.; Yu, Y. A Review on Various Optical Fiber Sensing Methods for Batteries. Renew. Sust. Energy Rev. 2021, 150, 111514. [Google Scholar] [CrossRef]
  20. Wahl, M.S.; Spitthoff, L.; Muri, H.I.; Jinasena, A.; Burheim, O.S.; Lamb, J.J. The Importance of Optical Fibers for Internal Temperature Sensing in Lithium-Ion Batteries during Operation. Energies 2021, 14, 3617. [Google Scholar] [CrossRef]
  21. Chen, D.; Zhao, Q.; Zheng, Y.; Xu, Y.; Chen, Y.; Ni, J.; Zhao, Y. Recent Progress in Lithium-Ion Battery Safety Monitoring Based on Fiber Bragg Grating Sensors. Sensors 2023, 23, 5609. [Google Scholar] [CrossRef]
  22. Su, Y.-D.; Preger, Y.; Burroughs, H.; Sun, C.; Ohodnicki, P. Fiber Optic Sensing Technologies for Battery Management Systems and Energy Storage Applications. Sensors 2021, 21, 1397. [Google Scholar] [CrossRef] [PubMed]
  23. Zhang, Y.; Li, Y.; Guo, Z.; Li, J.; Ge, X.; Sun, Q.; Yan, Z.; Li, Z.; Huang, Y. Health Monitoring by Optical Fiber Sensing Technology for Rechargeable Batteries. eScience 2023, 4, 100174. [Google Scholar] [CrossRef]
  24. Fortier, A.; Tsao, M.; Williard, N.; Xing, Y.; Pecht, M. Preliminary Study on Integration of Fiber Optic Bragg Grating Sensors in Li-Ion Batteries and In Situ Strain and Temperature Monitoring of Battery Cells. Energies 2017, 10, 838. [Google Scholar] [CrossRef]
  25. Li, B.; Parekh, M.H.; Adams, R.A.; Adams, T.E.; Love, C.T.; Pol, V.G.; Tomar, V. Lithium-Ion Battery Thermal Safety by Early Internal Detection, Prediction and Prevention. Sci. Rep. 2019, 9, 13255. [Google Scholar] [CrossRef]
  26. Barcellona, S.; Colnago, S.; Dotelli, G.; Latorrata, S.; Piegari, L. Aging Effect on the Variation of Li-Ion Battery Resistance as Function of Temperature and State of Charge. J. Energy Storage 2022, 50, 104658. [Google Scholar] [CrossRef]
  27. Robinson, J.; Shearing, P.; Brett, D. Thermal Imaging of Electrochemical Power Systems: A Review. J. Imaging 2016, 2, 2. [Google Scholar] [CrossRef]
  28. Winton, A.J.; Allen, M.A. Rational Design of a Bifunctional Peptide Exhibiting Lithium Titanate Oxide and Carbon Nanotube Affinities for Lithium-Ion Battery Applications. ACS Appl. Mater. Interfaces 2023, 15, 8579–8589. [Google Scholar] [CrossRef]
  29. Altin, S.; Altundag, E.; Altin, E.; Altundag, S. Improved Battery Performance of Silicon Modified Na0.67Fe0.5Mn0.5O2 and Its Structural and Electrochemical Properties: An Investigation of Infrared Thermal Imaging. J. Energy Storage 2021, 41, 102979. [Google Scholar] [CrossRef]
  30. Liu, Z.; Li, G.; Qin, Q.; Mi, L.; Li, G.; Zheng, G.; Liu, C.; Li, Q.; Liu, X. Electrospun PVDF/PAN Membrane for Pressure Sensor and Sodium-Ion Battery Separator. Adv. Compos. Hybrid Mater. 2021, 4, 1215–1225. [Google Scholar] [CrossRef]
  31. Cannarella, J.; Arnold, C.B. Stress Evolution and Capacity Fade in Constrained Lithium-Ion Pouch Cells. J. Power Sources 2014, 245, 745–751. [Google Scholar] [CrossRef]
  32. Hendricks, C.; Sood, B.; Pecht, M. Lithium-Ion Battery Strain Gauge Monitoring and Depth of Discharge Estimation. J. Electrochem. Energy 2023, 20, 011008. [Google Scholar] [CrossRef]
  33. Al-Tabbakh, A.A.; Karatepe, N.; Al-Zubaidi, A.B.; Benchaabane, A.; Mahmood, N.B. Crystallite Size and Lattice Strain of Lithiated Spinel Material for Rechargeable Battery by X-ray Diffraction Peak-Broadening Analysis. Int. J. Energy Res. 2019, 43, 1903–1911. [Google Scholar] [CrossRef]
  34. Louli, A.J.; Ellis, L.D.; Dahn, J.R. Operando Pressure Measurements Reveal Solid Electrolyte Interphase Growth to Rank Li-Ion Cell Performance. Joule 2019, 3, 745–761. [Google Scholar] [CrossRef]
  35. Wu, Y.; Sun, L.; Zhang, X.; Yang, M.; Tan, D.; Hai, C.; Liu, J.; Wang, J. Deformation Measurement within Lithium-Ion Battery Using Sparse-View Computed Tomography and Digital Image Correlation. Meas. Sci. Technol. 2023, 34, 025402. [Google Scholar] [CrossRef]
  36. Amaral, M.M.; Real, C.G.; Yukuhiro, V.Y.; Doubek, G.; Fernandez, P.S.; Singh, G.; Zanin, H. In Situ and Operando Infrared Spectroscopy of Battery Systems: Progress and Opportunities. J. Energy Chem. 2023, 81, 472–491. [Google Scholar] [CrossRef]
  37. Miele, E.; Dose, W.M.; Manyakin, I.; Frosz, M.H.; Ruff, Z.; De Volder, M.F.L.; Grey, C.P.; Baumberg, J.J.; Euser, T.G. Hollow-Core Optical Fiber Sensors for Operando Raman Spectroscopy Investigation of Li-Ion Battery Liquid Electrolytes. Nat. Commun. 2022, 13, 1651. [Google Scholar] [CrossRef]
  38. Liu, X.; Liang, Z.; Xiang, Y.; Lin, M.; Li, Q.; Liu, Z.; Zhong, G.; Fu, R.; Yang, Y. Solid-State NMR and MRI Spectroscopy for Li/Na Batteries: Materials, Interface, and In Situ Characterization. Adv. Mater. 2021, 33, 2005878. [Google Scholar] [CrossRef]
  39. Zhou, Y.; Su, M.; Yu, X.; Zhang, Y.; Wang, J.-G.; Ren, X.; Cao, R.; Xu, W.; Baer, D.R.; Du, Y.; et al. Real-Time Mass Spectrometric Characterization of the Solid–Electrolyte Interphase of a Lithium-Ion Battery. Nat. Nanotechnol. 2020, 15, 224–230. [Google Scholar] [CrossRef]
  40. Hedman, J.; Nilebo, D.; Larsson Langhammer, E.; Björefors, F. Fiber Optic Sensor for Characterisation of Lithium-Ion Batteries. ChemSusChem 2020, 13, 5731–5739. [Google Scholar] [CrossRef]
  41. Zachman, M.J.; Yang, Z.; Du, Y.; Chi, M. Robust Atomic-Resolution Imaging of Lithium in Battery Materials by Center-of-Mass Scanning Transmission Electron Microscopy. ACS Nano 2022, 16, 1358–1367. [Google Scholar] [CrossRef] [PubMed]
  42. Tran, M.-K.; Mathew, M.; Janhunen, S.; Panchal, S.; Raahemifar, K.; Fraser, R.; Fowler, M. A Comprehensive Equivalent Circuit Model for Lithium-Ion Batteries, Incorporating the Effects of State of Health, State of Charge, and Temperature on Model Parameters. J. Energy Storage 2021, 43, 103252. [Google Scholar] [CrossRef]
  43. Deng, D.R.; Cui, X.Y.; Wu, Q.H.; Zheng, M.S.; Dong, Q.F. In-situ Synthesis TiO2 Nanosheets@rGO for Ultrafast Sodium ion Storage at Both Room and Low Temperatures. J. Alloys Compd. 2020, 835. [Google Scholar] [CrossRef]
  44. Deng, D.R.; Yuan, R.M.; Yu, P.K.; Xue, F.; Fan, X.X.; Lei, J.; Zhang, J.L.; Lin, X.D.; Wu, Q.H.; Fan, J.M.; et al. An Enhanced Electrode via Coupling with a Conducting Molecule to Extend Interfacial Reactions. Adv. Energy Mater. 2021, 11, 2101156. [Google Scholar] [CrossRef]
  45. Deng, D.R.; Cui, X.Y.; Fan, X.X.; Zheng, J.Q.; Fan, X.H.; Wu, Q.H.; Zheng, M.S.; Dong, Q.F. Integration of Adsorption and Catalytic Active Sites in Cobalt Iron Oxide Nanorods for An Excellent Performance Li–S Battery with A Wide Temperature Range. Sustain. Energy Fuels 2021, 5, 4284–4288. [Google Scholar] [CrossRef]
  46. Deng, D.R.; Li, C.; Weng, J.C.; Fan, X.H.; Chen, Z.J.; Yang, G.; Li, Y.; Wu, Q.H.; Zheng, M.S.; Dong, Q.F. Thin Nano Cages with Limited Hollow Space for Ultrahigh Sulfur Loading Lithium–Sulfur Batteries. ACS Appl. Mater. Interfaces 2022, 14, 45414–45422. [Google Scholar] [CrossRef] [PubMed]
  47. Li, G.; Fan, X.; Deng, D.; Wu, Q.H.; Jia, L. Surface Charge Induced Self-assembled Nest-like Ni3S2/PNG Composites for High-performance Supercapacitors. J. Colloid Interf. Sci. 2023, 650, 913–923. [Google Scholar] [CrossRef] [PubMed]
  48. Choi, D.; Shamim, N.; Crawford, A.; Huang, Q.; Vartanian, C.K.; Viswanathan, V.V.; Paiss, M.D.; Alam, M.J.E.; Reed, D.M.; Sprenkle, V.L. Li-Ion Battery Technology for Grid Application. J. Power Sources 2021, 511, 230419. [Google Scholar] [CrossRef]
  49. Chen, Y.; Kang, Y.; Zhao, Y.; Wang, L.; Liu, J.; Li, Y.; Liang, Z.; He, X.; Li, X.; Tavajohi, N.; et al. A Review of Lithium-Ion Battery Safety Concerns: The Issues, Strategies, and Testing Standards. J. Energy Chem. 2021, 59, 83–99. [Google Scholar] [CrossRef]
  50. Kong, D.; Lv, H.; Ping, P.; Wang, G. A Review of Early Warning Methods of Thermal Runaway of Lithium Ion Batteries. J. Energy Storage 2023, 64, 107073. [Google Scholar] [CrossRef]
  51. Chombo, P.V.; Laoonual, Y. A Review of Safety Strategies of a Li-Ion Battery. J. Power Sources 2020, 478, 228649. [Google Scholar] [CrossRef]
  52. Ould Ely, T.; Kamzabek, D.; Chakraborty, D. Batteries Safety: Recent Progress and Current Challenges. Front. Energy Res. 2019, 7, 71. [Google Scholar] [CrossRef]
  53. Ren, D.; Feng, X.; Liu, L.; Hsu, H.; Lu, L.; Wang, L.; He, X.; Ouyang, M. Investigating the Relationship between Internal Short Circuit and Thermal Runaway of Lithium-Ion Batteries under Thermal Abuse Condition. Energy Storage Mater. 2021, 34, 563–573. [Google Scholar] [CrossRef]
  54. Lyu, P.; Liu, X.; Qu, J.; Zhao, J.; Huo, Y.; Qu, Z.; Rao, Z. Recent Advances of Thermal Safety of Lithium Ion Battery for Energy Storage. Energy Storage Mater. 2020, 31, 195–220. [Google Scholar] [CrossRef]
  55. Xiao, Z.; Liu, C.; Zhao, T.; Kuang, Y.; Yin, B.; Yuan, R.; Song, L. Review—Online Monitoring of Internal Temperature in Lithium-Ion Batteries. J. Electrochem. Soc. 2023, 170, 057517. [Google Scholar] [CrossRef]
  56. Meda, U.S.; Lal, L.; M, S.; Garg, P. Solid Electrolyte Interphase (SEI), a Boon or a Bane for Lithium Batteries: A Review on the Recent Advances. J. Energy Storage 2022, 47, 103564. [Google Scholar] [CrossRef]
  57. Rao Rikka, V.; Ranjan Sahu, S.; Chatterjee, A.; Gopalan, R.; Sundararajan, G.; Prakash, R. Composition-Dependent Long-Term Stability of Mosaic Solid-Electrolyte Interface for Long-Life Lithium-Ion Battery. Batter. Supercaps 2021, 4, 1720–1730. [Google Scholar] [CrossRef]
  58. Yan, C.; Xu, R.; Xiao, Y.; Ding, J.; Xu, L.; Li, B.; Huang, J. Toward Critical Electrode/Electrolyte Interfaces in Rechargeable Batteries. Adv. Funct. Mater. 2020, 30, 1909887. [Google Scholar] [CrossRef]
  59. Wu, H.; Jia, H.; Wang, C.; Zhang, J.; Xu, W. Recent Progress in Understanding Solid Electrolyte Interphase on Lithium Metal Anodes. Adv. Energy Mater. 2021, 11, 2003092. [Google Scholar] [CrossRef]
  60. Xu, H.; Han, C.; Li, W.; Li, H.; Qiu, X. Quantification of Lithium Dendrite and Solid Electrolyte Interphase (SEI) in Lithium-Ion Batteries. J. Power Sources 2022, 529, 231219. [Google Scholar] [CrossRef]
  61. Yoo, D.-J.; Liu, Q.; Cohen, O.; Kim, M.; Persson, K.A.; Zhang, Z. Understanding the Role of SEI Layer in Low-Temperature Performance of Lithium-Ion Batteries. ACS Appl. Mater. Interfaces 2022, 14, 11910–11918. [Google Scholar] [CrossRef] [PubMed]
  62. Hu, D.; Zhang, Q.; Tian, J.; Chen, L.; Li, N.; Su, Y.; Bao, L.; Lu, Y.; Cao, D.; Yan, K.; et al. High-Temperature Storage Deterioration Mechanism of Cylindrical 21700-Type Batteries Using Ni-Rich Cathodes under Different SOCs. ACS Appl. Mater. Interfaces 2021, 13, 6286–6297. [Google Scholar] [CrossRef] [PubMed]
  63. Feng, X.; He, X.; Ouyang, M.; Wang, L.; Lu, L.; Ren, D.; Santhanagopalan, S. A Coupled Electrochemical-Thermal Failure Model for Predicting the Thermal Runaway Behavior of Lithium-Ion Batteries. J. Electrochem. Soc. 2018, 165, A3748–A3765. [Google Scholar] [CrossRef]
  64. Li, Y.; Zhang, Y.; Li, Z.; Yan, Z.; Xiao, X.; Liu, X.; Chen, J.; Shen, Y.; Sun, Q.; Huang, Y. Operando Decoding of Surface Strain in Anode-Free Lithium Metal Batteries via Optical Fiber Sensor. Adv. Sci. 2022, 9, 2203247. [Google Scholar] [CrossRef] [PubMed]
  65. Li, Z.; Liu, J.; Qin, Y.; Gao, T. Enhancing the Charging Performance of Lithium-Ion Batteries by Reducing SEI and Charge Transfer Resistances. ACS Appl. Mater. Interfaces 2022, 14, 33004–33012. [Google Scholar] [CrossRef] [PubMed]
  66. Huang, D.; Engtrakul, C.; Nanayakkara, S.; Mulder, D.W.; Han, S.-D.; Zhou, M.; Luo, H.; Tenent, R.C. Understanding Degradation at the Lithium-Ion Battery Cathode/Electrolyte Interface: Connecting Transition-Metal Dissolution Mechanisms to Electrolyte Composition. ACS Appl. Mater. Interfaces 2021, 13, 11930–11939. [Google Scholar] [CrossRef]
  67. Guo, J.; Li, Y.; Pedersen, K.; Stroe, D.-I. Lithium-Ion Battery Operation, Degradation, and Aging Mechanism in Electric Vehicles: An Overview. Energies 2021, 14, 5220. [Google Scholar] [CrossRef]
  68. Han, X.; Lu, L.; Zheng, Y.; Feng, X.; Li, Z.; Li, J.; Ouyang, M. A Review on the Key Issues of the Lithium Ion Battery Degradation among the Whole Life Cycle. eTransportation 2019, 1, 100005. [Google Scholar] [CrossRef]
  69. Woody, M.; Arbabzadeh, M.; Lewis, G.M.; Keoleian, G.A.; Stefanopoulou, A. Strategies to Limit Degradation and Maximize Li-Ion Battery Service Lifetime - Critical Review and Guidance for Stakeholders. J. Energy Storage 2020, 28, 101231. [Google Scholar] [CrossRef]
  70. Miao, Z.; Li, Y.; Xiao, X.; Sun, Q.; He, B.; Chen, X.; Liao, Y.; Zhang, Y.; Yuan, L.; Yan, Z.; et al. Direct Optical Fiber Monitor on Stress Evolution of the Sulfur-Based Cathodes for Lithium–Sulfur Batteries. Energy Environ. Sci. 2022, 15, 2029–2038. [Google Scholar] [CrossRef]
  71. Palacín, M.R. Understanding Ageing in Li-Ion Batteries: A Chemical Issue. Chem. Soc. Rev. 2018, 47, 4924–4933. [Google Scholar] [CrossRef]
  72. Lo Presti, D.; Massaroni, C.; Jorge Leitao, C.S.; De Fatima Domingues, M.; Sypabekova, M.; Barrera, D.; Floris, I.; Massari, L.; Oddo, C.M.; Sales, S.; et al. Fiber Bragg Gratings for Medical Applications and Future Challenges: A Review. IEEE Access 2020, 8, 156863–156888. [Google Scholar] [CrossRef]
  73. Li, C.; Tang, J.; Cheng, C.; Cai, L.; Yang, M. FBG Arrays for Quasi-Distributed Sensing: A Review. Photonic Sens. 2021, 11, 91–108. [Google Scholar] [CrossRef]
  74. Bachar, L.; Klein, R.; Tur, M.; Bortman, J. Fault Diagnosis of Gear Transmissions via Optic Fiber Bragg Grating Strain Sensors. Mech. Syst. Signal Process. 2022, 169, 108629. [Google Scholar] [CrossRef]
  75. Rohan, R.; Venkadeshwaran, K.; Ranjan, P. Recent Advancements of Fiber Bragg Grating Sensors in Biomedical Application: A Review. J. Opt. 2023. [Google Scholar] [CrossRef]
  76. Vikas; Mishra, S.; Mishra, A.; Saccomandi, P.; Verma, R. Recent Advances in Lossy Mode Resonance-Based Fiber Optic Sensors: A Review. Micromachines 2022, 13, 1921. [Google Scholar] [CrossRef]
  77. Meitei, S.N.; Borah, K.; Chatterjee, S. Partial Discharge Detection in an Oil-Filled Power Transformer Using Fiber Bragg Grating Sensors: A Review. IEEE Sens. J. 2021, 21, 10304–10316. [Google Scholar] [CrossRef]
  78. Luo, Y.; Zhang, Q.; Zhang, J.; Feng, D.; Wu, P.; Zhang, Y.; Lv, H.; Yang, N.; Wang, D.; Zhan, H.; et al. Research on Spacecraft Strain Measurement System and Impact Sensing Technology Based on Fiber Grating Sensors and All Fiber Optic Sensing. J. Phys. Conf. Ser. 2021, 1846, 012094. [Google Scholar] [CrossRef]
  79. Bonopera, M. Fiber-Bragg-Grating-Based Displacement Sensors: Review of Recent Advances. Materials 2022, 15, 5561. [Google Scholar] [CrossRef]
  80. Li, T.; Guo, J.; Tan, Y.; Zhou, Z. Recent Advances and Tendency in Fiber Bragg Grating-Based Vibration Sensor: A Review. IEEE Sens. J. 2020, 20, 12074–12087. [Google Scholar] [CrossRef]
  81. Shadab, A.; Raghuwanshi, S.K.; Kumar, S. Advances in Micro-Fabricated Fiber Bragg Grating for Detection of Physical, Chemical, and Biological Parameters—A Review. IEEE Sens. J. 2022, 22, 15650–15660. [Google Scholar] [CrossRef]
  82. Massaroni, C.; Zaltieri, M.; Lo Presti, D.; Nicolo, A.; Tosi, D.; Schena, E. Fiber Bragg Grating Sensors for Cardiorespiratory Monitoring: A Review. IEEE Sens. J. 2021, 21, 14069–14080. [Google Scholar] [CrossRef]
  83. Caucheteur, C.; Guo, T.; Liu, F.; Guan, B.-O.; Albert, J. Ultrasensitive Plasmonic Sensing in Air Using Optical Fiber Spectral Combs. Nat. Commun. 2016, 7, 13371. [Google Scholar] [CrossRef]
  84. Li, Z.; Xiao, Y.; Liu, F.; Yan, X.; You, D.; Li, K.; Zeng, L.; Zhu, M.; Xiao, G.; Albert, J.; et al. Operando Optical Fiber Monitoring of Nanoscale and Fast Temperature Changes during Photo-Electrocatalytic Reactions. Light Sci. Appl. 2022, 11, 220. [Google Scholar] [CrossRef]
  85. Liu, L.; Zhang, X.; Zhu, Q.; Li, K.; Lu, Y.; Zhou, X.; Guo, T. Ultrasensitive Detection of Endocrine Disruptors via Superfine Plasmonic Spectral Combs. Light Sci. Appl. 2021, 10, 181. [Google Scholar] [CrossRef]
  86. Zhu, C.; Wang, L.; Li, H. Phase-Inserted Fiber Gratings and Their Applications to Optical Filtering, Optical Signal Processing, and Optical Sensing: Review. Photonics 2022, 9, 271. [Google Scholar] [CrossRef]
  87. Gao, S.; Wang, H.; Chen, Y.; Wei, H.; Woyessa, G.; Bang, O.; Min, R.; Qu, H.; Caucheteur, C.; Hu, X. Point-by-Point Induced High Birefringence Polymer Optical Fiber Bragg Grating for Strain Measurement. Photonics 2023, 10, 91. [Google Scholar] [CrossRef]
  88. Matveenko, V.; Serovaev, G. Distributed Strain Measurements Based on Rayleigh Scattering in the Presence of Fiber Bragg Gratings in an Optical Fiber. Photonics 2023, 10, 868. [Google Scholar] [CrossRef]
  89. Cheng, X.; Pecht, M. In Situ Stress Measurement Techniques on Li-Ion Battery Electrodes: A Review. Energies 2017, 10, 591. [Google Scholar] [CrossRef]
  90. Huang, J.; Han, X.; Liu, F.; Gervillié, C.; Blanquer, L.A.; Guo, T.; Tarascon, J.-M. Monitoring Battery Electrolyte Chemistry via in-Operando Tilted Fiber Bragg Grating Sensors. Energy Environ. Sci. 2021, 14, 6464–6475. [Google Scholar] [CrossRef]
  91. Singh, Y.; Raghuwanshi, S.K.; Prakash, O.; Saini, P.K. Design and Development of Tilted Fiber Bragg Grating (TFBG) Chemical Sensor with Regression Analysis of Grating Parameters for Sensitivity Optimization. Opt. Quant Electron. 2021, 53, 664. [Google Scholar] [CrossRef]
  92. Xue, X.; Han, X.; Li, L.; Min, L.; You, D.; Guo, T. Real-Time Monitoring of Human Breathing Using Wearable Tilted Fiber Grating Curvature Sensors. J. Lightwave Technol. 2023, 41, 4531–4539. [Google Scholar] [CrossRef]
  93. Sypabekova, M.; Amantayeva, A.; Vangelista, L.; González-Vila, Á.; Caucheteur, C.; Tosi, D. Ultralow Limit Detection of Soluble HER2 Biomarker in Serum with a Fiber-Optic Ball-Tip Resonator Assisted by a Tilted FBG. ACS Meas. Sci. Au 2022, 2, 309–316. [Google Scholar] [CrossRef]
  94. Yang, G.; Leitão, C.; Li, Y.; Pinto, J.; Jiang, X. Real-Time Temperature Measurement with Fiber Bragg Sensors in Lithium Batteries for Safety Usage. Measurement 2013, 46, 3166–3172. [Google Scholar] [CrossRef]
  95. Nascimento, M.; Paixão, T.; Ferreira, M.; Pinto, J. Thermal Mapping of a Lithium Polymer Batteries Pack with FBGs Network. Batteries 2018, 4, 67. [Google Scholar] [CrossRef]
  96. Nascimento, M.; Ferreira, M.S.; Pinto, J.L. Temperature Fiber Sensing of Li-Ion Batteries under Different Environmental and Operating Conditions. Appl. Therm. Eng. 2019, 149, 1236–1243. [Google Scholar] [CrossRef]
  97. Matuck, L.; Pinto, J.L.; Marques, C.; Nascimento, M. Evaluation of the Orientation Impact on Thermal Behavior of Cylindrical Li-Ion Batteries in Different Cycling Conditions Using Fiber Bragg Grating Sensors. J. Phys. Conf. Ser. 2022, 2407, 012050. [Google Scholar] [CrossRef]
  98. Sommer, L.W.; Kiesel, P.; Ganguli, A.; Lochbaum, A.; Saha, B.; Schwartz, J.; Bae, C.-J.; Alamgir, M.; Raghavan, A. Fast and Slow Ion Diffusion Processes in Lithium Ion Pouch Cells during Cycling Observed with Fiber Optic Strain Sensors. J. Power Sources 2015, 296, 46–52. [Google Scholar] [CrossRef]
  99. Pereira, G.; McGugan, M.; Mikkelsen, L.P. Method for Independent Strain and Temperature Measurement in Polymeric Tensile Test Specimen Using Embedded FBG Sensors. Polymer Test. 2016, 50, 125–134. [Google Scholar] [CrossRef]
  100. Nascimento, M.; Ferreira, M.; Pinto, J. Simultaneous Sensing of Temperature and Bi-Directional Strain in a Prismatic Li-Ion Battery. Batteries 2018, 4, 23. [Google Scholar] [CrossRef]
  101. Matuck, L.; Pinto, J.L.; Marques, C.; Nascimento, M. Simultaneous Strain and Temperature Discrimination in 18650 Li-Ion Batteries Using Polarization-Maintaining Fiber Bragg Gratings. Batteries 2022, 8, 233. [Google Scholar] [CrossRef]
  102. Sommer, L.W.; Raghavan, A.; Kiesel, P.; Saha, B.; Schwartz, J.; Lochbaum, A.; Ganguli, A.; Bae, C.-J.; Alamgir, M. Monitoring of Intercalation Stages in Lithium-Ion Cells over Charge-Discharge Cycles with Fiber Optic Sensors. J. Electrochem. Soc. 2015, 162, A2664–A2669. [Google Scholar] [CrossRef]
  103. Chen, C.-Y.; Sawamura, A.; Tsuda, T.; Uchida, S.; Ishikawa, M.; Kuwabata, S. Visualization of Si Anode Reactions in Coin-Type Cells via Operando Scanning Electron Microscopy. ACS Appl. Mater. Interfaces 2017, 9, 35511–35515. [Google Scholar] [CrossRef]
  104. Duan, X.; Wang, H.; Jia, Y.; Wang, L.; Liu, B.; Xu, J. A Multiphysics Understanding of Internal Short Circuit Mechanisms in Lithium-Ion Batteries upon Mechanical Stress Abuse. Energy Storage Mater. 2022, 45, 667–679. [Google Scholar] [CrossRef]
  105. Zhang, K.; Yin, J.; He, Y. Acoustic Emission Detection and Analysis Method for Health Status of Lithium Ion Batteries. Sensors 2021, 21, 712. [Google Scholar] [CrossRef]
  106. Chien, Y.-C.; Menon, A.S.; Brant, W.R.; Lacey, M.J.; Brandell, D. Understanding the Impact of Precipitation Kinetics on the Electrochemical Performance of Lithium–Sulfur Batteries by Operando X-ray Diffraction. J. Phys. Chem. C 2022, 126, 2971–2979. [Google Scholar] [CrossRef]
  107. Choi, W.; Shin, H.-C.; Kim, J.M.; Choi, J.-Y.; Yoon, W.-S. Modeling and Applications of Electrochemical Impedance Spectroscopy (EIS) for Lithium-Ion Batteries. J. Electrochem. Sci. Technol. 2020, 11, 1–13. [Google Scholar] [CrossRef]
  108. Ghannoum, A.; Nieva, P. Graphite Lithiation and Capacity Fade Monitoring of Lithium Ion Batteries Using Optical Fibers. J. Energy Storage 2020, 28, 101233. [Google Scholar] [CrossRef]
  109. Gervillié-Mouravieff, C.; Boussard-Plédel, C.; Huang, J.; Leau, C.; Blanquer, L.A.; Yahia, M.B.; Doublet, M.-L.; Boles, S.T.; Zhang, X.H.; Adam, J.L.; et al. Unlocking Cell Chemistry Evolution with Operando Fiber Optic Infrared Spectroscopy in Commercial Na(Li)-Ion Batteries. Nat. Energy 2022, 7, 1157–1169. [Google Scholar] [CrossRef]
  110. Wang, R.; Zhang, H.; Liu, Q.; Liu, F.; Han, X.; Liu, X.; Li, K.; Xiao, G.; Albert, J.; Lu, X.; et al. Operando Monitoring of Ion Activities in Aqueous Batteries with Plasmonic Fiber-Optic Sensors. Nat. Commun. 2022, 13, 547. [Google Scholar] [CrossRef]
  111. Han, X.; Zhong, H.; Li, K.; Xue, X.; Wu, W.; Hu, N.; Lu, X.; Huang, J.; Xiao, G.; Mai, Y.; et al. Operando Monitoring of Dendrite Formation in Lithium Metal Batteries via Ultrasensitive Tilted Fiber Bragg Grating Sensors. Light Sci. Appl. 2024, 13, 24. [Google Scholar] [CrossRef]
  112. Xi, J.; Li, J.; Sun, H.; Ma, T.; Deng, L.; Liu, N.; Huang, X.; Zhang, J. In-Situ Monitoring of Internal Temperature and Strain of Solid-State Battery Based on Optical Fiber Sensors. Sens. Actuat. A-Phys. 2022, 347, 113888. [Google Scholar] [CrossRef]
  113. Yang, L.; Li, N.; Hu, L.; Wang, S.; Wang, L.; Zhou, J.; Song, W.-L.; Sun, L.; Pan, T.-S.; Chen, H.-S.; et al. Internal Field Study of 21700 Battery Based on Long-Life Embedded Wireless Temperature Sensor. Acta Mech. Sin. 2021, 37, 895–901. [Google Scholar] [CrossRef]
  114. Parhizi, M.; Ahmed, M.B.; Jain, A. Determination of the Core Temperature of a Li-Ion Cell during Thermal Runaway. J. Power Sources 2017, 370, 27–35. [Google Scholar] [CrossRef]
  115. Amietszajew, T.; McTurk, E.; Fleming, J.; Bhagat, R. Understanding the Limits of Rapid Charging Using Instrumented Commercial 18650 High-Energy Li-Ion Cells. Electrochim. Acta 2018, 263, 346–352. [Google Scholar] [CrossRef]
  116. Fleming, J.; Amietszajew, T.; McTurk, E.; Towers, D.P.; Greenwood, D.; Bhagat, R. Development and Evaluation of In-Situ Instrumentation for Cylindrical Li-Ion Cells Using Fiber Optic Sensors. HardwareX 2018, 3, 100–109. [Google Scholar] [CrossRef]
  117. Liu, Y.; Liu, Z.; Mei, W.; Han, X.; Liu, P.; Wang, C.; Xia, X.; Li, K.; Wang, S.; Wang, Q.; et al. Operando Monitoring Lithium-Ion Battery Temperature via Implanting Femtosecond-Laser-Inscribed Optical Fiber Sensors. Measurement 2022, 203, 111961. [Google Scholar] [CrossRef]
  118. Bae, C.; Manandhar, A.; Kiesel, P.; Raghavan, A. Monitoring the Strain Evolution of Lithium-Ion Battery Electrodes Using an Optical Fiber Bragg Grating Sensor. Energy Technol. 2016, 4, 851–855. [Google Scholar] [CrossRef]
  119. Ganguli, A.; Saha, B.; Raghavan, A.; Kiesel, P.; Arakaki, K.; Schuh, A.; Schwartz, J.; Hegyi, A.; Sommer, L.W.; Lochbaum, A.; et al. Embedded Fiber-Optic Sensing for Accurate Internal Monitoring of Cell State in Advanced Battery Management Systems Part 2: Internal Cell Signals and Utility for State Estimation. J. Power Sources 2017, 341, 474–482. [Google Scholar] [CrossRef]
  120. Albero Blanquer, L.; Marchini, F.; Seitz, J.R.; Daher, N.; Bétermier, F.; Huang, J.; Gervillié, C.; Tarascon, J.-M. Optical Sensors for Operando Stress Monitoring in Lithium-Based Batteries Containing Solid-State or Liquid Electrolytes. Nat. Commun. 2022, 13, 1153. [Google Scholar] [CrossRef]
  121. Unterkofler, J.; Glanz, G.; Koller, M.; Klambauer, R.; Bergmann, A. Strain Compensation Methods for Fiber Bragg Grating Temperature Sensors Suitable for Integration into Lithium-Ion Battery Electrolyte. Batteries 2023, 9, 34. [Google Scholar] [CrossRef]
  122. Nascimento, M.; Novais, S.; Ding, M.S.; Ferreira, M.S.; Koch, S.; Passerini, S.; Pinto, J.L. Internal Strain and Temperature Discrimination with Optical Fiber Hybrid Sensors in Li-Ion Batteries. J. Power Sources 2019, 410–411, 1–9. [Google Scholar] [CrossRef]
  123. Lao, J.; Sun, P.; Liu, F.; Zhang, X.; Zhao, C.; Mai, W.; Guo, T.; Xiao, G.; Albert, J. In Situ Plasmonic Optical Fiber Detection of the State of Charge of Supercapacitors for Renewable Energy Storage. Light Sci. Appl. 2018, 7, 34. [Google Scholar] [CrossRef]
  124. Huang, J.; Albero Blanquer, L.; Bonefacino, J.; Logan, E.R.; Alves Dalla Corte, D.; Delacourt, C.; Gallant, B.M.; Boles, S.T.; Dahn, J.R.; Tam, H.-Y.; et al. Operando Decoding of Chemical and Thermal Events in Commercial Na(Li)-Ion Cells via Optical Sensors. Nat. Energy 2020, 5, 674–683. [Google Scholar] [CrossRef]
  125. Desai, P.; Huang, J.; Hijazi, H.; Zhang, L.; Mariyappan, S.; Tarascon, J. Deciphering Interfacial Reactions via Optical Sensing to Tune the Interphase Chemistry for Optimized Na-Ion Electrolyte Formulation. Adv. Energy Mater. 2021, 11, 2101490. [Google Scholar] [CrossRef]
  126. Mei, W.; Liu, Z.; Wang, C.; Wu, C.; Liu, Y.; Liu, P.; Xia, X.; Xue, X.; Han, X.; Sun, J.; et al. Operando Monitoring of Thermal Runaway in Commercial Lithium-Ion Cells via Advanced Lab-on-Fiber Technologies. Nat. Commun. 2023, 14, 5251. [Google Scholar] [CrossRef]
  127. Nedjalkov, A.; Meyer, J.; Gräfenstein, A.; Schramm, B.; Angelmahr, M.; Schwenzel, J.; Schade, W. Refractive Index Measurement of Lithium Ion Battery Electrolyte with Etched Surface Cladding Waveguide Bragg Gratings and Cell Electrode State Monitoring by Optical Strain Sensors. Batteries 2019, 5, 30. [Google Scholar] [CrossRef]
  128. Liu, Z.; Zhang, Z.; Tam, H.-Y.; Tao, X. Multifunctional Smart Optical Fibers: Materials, Fabrication, and Sensing Applications. Photonics 2019, 6, 48. [Google Scholar] [CrossRef]
  129. Liu, W.; Liu, Z.; Zhang, Y.; Li, S.; Zhang, Y.; Yang, X.; Zhang, J.; Yuan, L. Specialty Optical Fibers and 2D Materials for Sensitivity Enhancement of Fiber Optic SPR Sensors: A Review. Opt. Laser Technol. 2022, 152, 108167. [Google Scholar] [CrossRef]
  130. Alcock, K.M.; Grammel, M.; González-Vila, Á.; Binetti, L.; Goh, K.; Alwis, L.S.M. An Accessible Method of Embedding Fiber Optic Sensors on Lithium-Ion Battery Surface for in-Situ Thermal Monitoring. Sens. Actuat. A-Phys. 2021, 332, 113061. [Google Scholar] [CrossRef]
  131. Chen, W.; Hao, J.; Tang, M. Improved Estimate and Accurate Measurement of Thermal Stresses in FRP Tendon. Constr. Build. Mater. 2018, 164, 620–624. [Google Scholar] [CrossRef]
  132. Chen, W.; Hao, J.; Tang, M. Analytical Analysis of Dynamic Stress Distribution of Fiber Reinforced Polymer Rod Based on Realistic Boundary Shear Stress. Compos. Part B Eng. 2017, 131, 209–220. [Google Scholar] [CrossRef]
  133. Lai, W.; Cao, L.; Tan, R.X.; Phan, P.T.; Hao, J.; Tjin S., C.; Phee S., J. Force Sensing With 1 mm Fiber Bragg Gratings for Flexible Endoscopic Surgical Robots. IEEE-ASME Trans. Mechatron. 2020, 25, 371–382. [Google Scholar] [CrossRef]
  134. Chen, W.; Dong, X.; Hao, J.; Yang, F.; Hu, X. Analysis of the Stress Distribution of Crimped Pultruded Composite Rods Subjected to Traction. Compos. Part B Eng. 2013, 50, 362–370. [Google Scholar] [CrossRef]
  135. Madan, A.; Liu, O.; Jiang, W.; Wang, Y.; Shum, P.P.; Hao, J. Carbon-Steel Tube Surface Mounted FBG Sensors under High-Temperature Environment, Part I: Polyimide Coated and Femtosecond Laser Written. In Proceedings of the 2020 IEEE 5th Optoelectronics Global Conference (OGC), Shenzhen, China, 7 September 2020; pp. 125–129. [Google Scholar]
  136. Madan, A.; Yap, S.H.K.; Paulose, V.; Chang, W.; Shum, P.P.; Hao, J. Investigation of a Bragg Grating-Based Fabry–Perot Structure Inscribed Using Femtosecond Laser Micromachining in an Adiabatic Fiber Taper. Appl. Sci. 2020, 10, 1069. [Google Scholar] [CrossRef]
  137. Chen, W.; Hao, J.; Zhang, H. Analytical Solution of Mechanical Behavior of FRP Joint with Arbitrary Bond Length for Optimal Design. Constr. Build. Mater. 2020, 253, 119125. [Google Scholar] [CrossRef]
  138. Liu, K.; Li, K.; Peng, Q.; Zhang, C. A Brief Review on Key Technologies in the Battery Management System of Electric Vehicles. Front. Mech. Eng. 2019, 14, 47–64. [Google Scholar] [CrossRef]
  139. Xiong, R.; Yu, Q.; Shen, W.; Lin, C.; Sun, F. A Sensor Fault Diagnosis Method for a Lithium-Ion Battery Pack in Electric Vehicles. IEEE Trans. Power Electron. 2019, 34, 9709–9718. [Google Scholar] [CrossRef]
  140. Cheng, Y.; D’Arpino, M.; Rizzoni, G. Optimal Sensor Placement for Multifault Detection and Isolation in Lithium-Ion Battery Pack. IEEE Trans. Transp. Electrif. 2022, 8, 4687–4707. [Google Scholar] [CrossRef]
  141. Yu, Y.; Vergori, E.; Maddar, F.; Guo, Y.; Greenwood, D.; Marco, J. Real-Time Monitoring of Internal Structural Deformation and Thermal Events in Lithium-Ion Cell via Embedded Distributed Optical Fiber. J. Power Sources 2022, 521, 230957. [Google Scholar] [CrossRef]
  142. Anfinogentov, V.; Karimov, K.; Kuznetsov, A.; Morozov, O.G.; Nureev, I.; Sakhabutdinov, A.; Lipatnikov, K.; Hussein, S.M.R.H.; Ali, M.H. Algorithm of FBG Spectrum Distortion Correction for Optical Spectra Analyzers with CCD Elements. Sensors 2021, 21, 2817. [Google Scholar] [CrossRef]
  143. Turov, A.T.; Barkov, F.L.; Konstantinov, Y.A.; Korobko, D.A.; Lopez-Mercado, C.A.; Fotiadi, A.A. Activation Function Dynamic Averaging as a Technique for Nonlinear 2D Data Denoising in Distributed Acoustic Sensors. Algorithms 2023, 16, 440. [Google Scholar] [CrossRef]
  144. Fernández-Ruiz, M.R.; Carballar, A. Fiber Bragg Grating-Based Optical Signal Processing: Review and Survey. Appl. Sci. 2021, 11, 8189. [Google Scholar] [CrossRef]
  145. Al-Gabalawy, M.; Hosny, N.S.; Dawson, J.A.; Omar, A.I. State of Charge Estimation of a Li-ion Battery Based on Extended Kalman Filtering and Sensor Bias. Int. J. Energy Res. 2021, 45, 6708–6726. [Google Scholar] [CrossRef]
  146. Hu, J.; Bian, X.; Wei, Z.; Li, J.; He, H. Residual Statistics-Based Current Sensor Fault Diagnosis for Smart Battery Management. IEEE J. Emerg. Sel. Top. Power 2022, 10, 2435–2444. [Google Scholar] [CrossRef]
  147. Hou, J.; Yang, Y.; Gao, T. A Normal-gamma-based Adaptive Dual Unscented Kalman Filter for Battery Parameters and State-of-charge Estimation with Heavy-tailed Measurement Noise. Int. J. Energy Res. 2020, 44, 3510–3525. [Google Scholar] [CrossRef]
  148. Cui, Z.; Cui, N.; Wang, C.; Li, C.; Zhang, C. A Robust Online Parameter Identification Method for Lithium-Ion Battery Model Under Asynchronous Sampling and Noise Interference. IEEE Trans. Ind. Electron. 2021, 68, 9550–9560. [Google Scholar] [CrossRef]
  149. Shen, M.; Gao, Q. A Review on Battery Management System from the Modeling Efforts to Its Multiapplication and Integration. Int. J. Energy Res. 2019, 43, 5042–5075. [Google Scholar] [CrossRef]
  150. Li, Y.; Li, K.; Liu, X.; Li, X.; Zhang, L.; Rente, B.; Sun, T.; Grattan, K.T.V. A Hybrid Machine Learning Framework for Joint SOC and SOH Estimation of Lithium-Ion Batteries Assisted with Fiber Sensor Measurements. Appl. Energy 2022, 325, 119787. [Google Scholar] [CrossRef]
  151. Hossain Lipu, M.; Karim, T.; Ansari, S.; Miah, M.; Rahman, M.; Meraj, S.; Elavarasan, R.; Vijayaraghavan, R. Intelligent SOX Estimation for Automotive Battery Management Systems: State-of-the-Art Deep Learning Approaches, Open Issues, and Future Research Opportunities. Energies 2022, 16, 23. [Google Scholar] [CrossRef]
  152. Alcock, K.M.; González-Vila, Á.; Beg, M.; Vedreño-Santos, F.; Cai, Z.; Alwis, L.S.M.; Goh, K. Individual Cell-Level Temperature Monitoring of a Lithium-Ion Battery Pack. Sensors 2023, 23, 4306. [Google Scholar] [CrossRef]
  153. Zhang, L.; Liu, X.; Li, K.; Du, D.; Zheng, M.; Niu, Q.; Yang, Y.; Zhou, Q.; Sun, T.; Grattan, K.T.V. Real-Time Battery Temperature Monitoring Using FBG Sensors: A Data-Driven Calibration Method. IEEE Sens. J. 2022, 22, 18639–18648. [Google Scholar] [CrossRef]
  154. Wei, Z.; Hu, J.; He, H.; Yu, Y.; Marco, J. Embedded Distributed Temperature Sensing Enabled Multistate Joint Observation of Smart Lithium-Ion Battery. IEEE Trans. Ind. Electron. 2023, 70, 555–565. [Google Scholar] [CrossRef]
  155. Wu, M.; Chen, Y.; Zhu, P.; Chen, W. NLM Parameter Optimization for φ-OTDR Signal. J. Lightwave Technol. 2022, 40, 6045–6051. [Google Scholar] [CrossRef]
  156. Chen, Y.; Zhu, P.; Yin, Y.; Wu, M.; Yu, K.; Feng, L.; Chen, W. Objective Assessment of IPM Denoising Quality of φ-OTDR Signal. Measurement 2023, 214, 112775. [Google Scholar] [CrossRef]
  157. Chen, Y.; Zhu, S.; Yu, K.; Wu, M.; Feng, L.; Zhu, P.; Chen, W. Quantitative Analysis of φ-OTDR Spatial Resolution Influenced by NLM Parameters. Photonics 2023, 10, 529. [Google Scholar] [CrossRef]
  158. Yu, K.; Feng, L.; Chen, Y.; Wu, M.; Zhang, Y.; Zhu, P.; Chen, W.; Wu, Q.; Hao, J. Accurate Wavelet Thresholding Method for ECG Signals. Comput. Biol. Med. 2024, 169, 107835. [Google Scholar] [CrossRef]
  159. Chen, Y.; Yu, K.; Wu, M.; Feng, L.; Zhang, Y.; Zhu, P.; Chen, W.; Hao, J. Wavelet Decomposition Layer Selection for the φ-OTDR Signal. Photonics 2024, 11, 137. [Google Scholar] [CrossRef]
  160. Astafev, E.A. Measurements and Analysis of Electrochemical Noise of Li-Ion Battery. Russ. J. Electrochem. 2019, 55, 488–495. [Google Scholar] [CrossRef]
  161. Hua, X.; Thomas, A.; Shultis, K. Recent Progress in Battery Electric Vehicle Noise, Vibration, and Harshness. Sci. Prog. 2021, 104, 003685042110052. [Google Scholar] [CrossRef]
  162. Raghavan, A.; Kiesel, P.; Sommer, L.W.; Schwartz, J.; Lochbaum, A.; Hegyi, A.; Schuh, A.; Arakaki, K.; Saha, B.; Ganguli, A.; et al. Embedded Fiber-Optic Sensing for Accurate Internal Monitoring of Cell State in Advanced Battery Management Systems Part 1: Cell Embedding Method and Performance. J. Power Sources 2017, 341, 466–473. [Google Scholar] [CrossRef]
  163. Edström, K.; Dominko, R.; Fichtner, M.; Perraud, S. Battery 2030+ Roadmap; Uppsala University: Uppsala, Sweden, 2020; pp. 45–46. [Google Scholar]
  164. Fichtner, M.; Edström, K.; Ayerbe, E.; Berecibar, M.; Bhowmik, A.; Castelli, I.E.; Clark, S.; Dominko, R.; Erakca, M.; Franco, A.A.; et al. Rechargeable Batteries of the Future—The State of the Art from a BATTERY 2030+ Perspective. Adv. Energy Mater. 2022, 12, 2102904. [Google Scholar] [CrossRef]
  165. Xu, J.; Ma, J.; Zhao, X.; Chen, H.; Xu, B.; Wu, X. Detection Technology for Battery Safety in Electric Vehicles: A Review. Energies 2020, 13, 4636. [Google Scholar] [CrossRef]
Figure 1. Typical scheme of FBG sensors.
Figure 1. Typical scheme of FBG sensors.
Sensors 24 02057 g001
Figure 2. Description of the interrogation system.
Figure 2. Description of the interrogation system.
Sensors 24 02057 g002
Figure 3. Typical scheme of TFBG sensors.
Figure 3. Typical scheme of TFBG sensors.
Sensors 24 02057 g003
Figure 4. TFBG-based SPR optical fiber sensor [110]: (a) ionic concentration; (b) sketch of the configuration of a plasmonic fiber optic sensor; and (c) experimental setup for RI monitoring.
Figure 4. TFBG-based SPR optical fiber sensor [110]: (a) ionic concentration; (b) sketch of the configuration of a plasmonic fiber optic sensor; and (c) experimental setup for RI monitoring.
Sensors 24 02057 g004
Figure 5. Monitoring temperature changes in pouch Li-ion battery using thermocouple sensors and FBG sensors [13].
Figure 5. Monitoring temperature changes in pouch Li-ion battery using thermocouple sensors and FBG sensors [13].
Sensors 24 02057 g005
Figure 6. FBG-based temperature measurement for cylindrical Li-ion battery: (a) single FBG sensing element schematic [115]; (b) four FBG sensing elements uniformly distributed schematic [116].
Figure 6. FBG-based temperature measurement for cylindrical Li-ion battery: (a) single FBG sensing element schematic [115]; (b) four FBG sensing elements uniformly distributed schematic [116].
Sensors 24 02057 g006
Figure 7. Schematic of integrating FBG sensors into the central void of cylindrical jelly-roll Li-ion battery [117].
Figure 7. Schematic of integrating FBG sensors into the central void of cylindrical jelly-roll Li-ion battery [117].
Sensors 24 02057 g007
Figure 8. Schematic diagram of FBG array thin film temperature measurement device [15].
Figure 8. Schematic diagram of FBG array thin film temperature measurement device [15].
Sensors 24 02057 g008
Figure 9. Two different approaches [118]: (a) internally attached FBG strain sensor on graphite anode; (b) internally implanted FBC strain sensor within graphite anode.
Figure 9. Two different approaches [118]: (a) internally attached FBG strain sensor on graphite anode; (b) internally implanted FBC strain sensor within graphite anode.
Sensors 24 02057 g009
Figure 10. FBG sensor integrated into a Li-ion coin cell [24]: (a) case of the coin cell; (b) all components of the coin cell; (c) SEM image of the damaged cathode at 500 micron magnification; and (d) SEM image of the damaged cathode at 300 micron magnification.
Figure 10. FBG sensor integrated into a Li-ion coin cell [24]: (a) case of the coin cell; (b) all components of the coin cell; (c) SEM image of the damaged cathode at 500 micron magnification; and (d) SEM image of the damaged cathode at 300 micron magnification.
Sensors 24 02057 g010
Figure 11. Simultaneous monitoring of temperature and strain scheme [122]: (a) FBG combined with FP; (b) diagram of the experimental setup of a sensor network for temperature and strain monitoring of Li-ion pouch battery.
Figure 11. Simultaneous monitoring of temperature and strain scheme [122]: (a) FBG combined with FP; (b) diagram of the experimental setup of a sensor network for temperature and strain monitoring of Li-ion pouch battery.
Sensors 24 02057 g011
Figure 12. Schematic diagram of the location of the FBG sensors [112].
Figure 12. Schematic diagram of the location of the FBG sensors [112].
Sensors 24 02057 g012
Figure 13. Monitor internal battery temperature and pressure: (a) cross-section of SMF and MOF; (b) SMF-FBG and MOF-FBG implanted into Li-ion battery.
Figure 13. Monitor internal battery temperature and pressure: (a) cross-section of SMF and MOF; (b) SMF-FBG and MOF-FBG implanted into Li-ion battery.
Sensors 24 02057 g013
Figure 14. Schematic of typical and enhanced sensitivity optical waveguide structures [127]: (a) the original design, where the grating is inscribed in the fiber core; (b) the self-compensating design, where an additional waveguide is inscribed in the cladding to increase the refractive-index sensitivity and to direct some of the propagating light to this waveguide.
Figure 14. Schematic of typical and enhanced sensitivity optical waveguide structures [127]: (a) the original design, where the grating is inscribed in the fiber core; (b) the self-compensating design, where an additional waveguide is inscribed in the cladding to increase the refractive-index sensitivity and to direct some of the propagating light to this waveguide.
Sensors 24 02057 g014
Table 2. Summary of FBG Sensor Monitoring Battery Performance.
Table 2. Summary of FBG Sensor Monitoring Battery Performance.
YearBattery TypeMeasured ParameterAccuracySensitivityRef.
2016Li-ion Pouch BatteryExternal and internal temperatures0.1 °C10.27 pm/°C [13]
2018Li-ion Cylindrical BatteryInternal temperatures-- [115]
2018Li-ion Cylindrical BatteryInternal temperatures1 °C11 pm/°C [116]
2022Li-ion Cylindrical BatteryInternal temperatures0.5 °C9.89 pm/°C [117]
2023Hardcase Li-ion BatteriesExternal and internal temperatures0.5 °C9.8 ± 0.2 pm/°C [15]
2016Li-ion Pouch BatteryInternal strain-- [118]
2022Swagelok BatteryInternal strain-- [120]
2022Li–S Pouch BatteryInternal strain-0.847 pm/ μ ε  [70]
2022Li-ion BatteryInternal temperatures-11 ± 0.3 pm/°C [121]
2017Li-ion Coin BatteryInternal temperature and strain-- [24]
2019Li-ion Pouch BatteryInternal temperature and strain0.1 °C, 0.1 μ ε 40 pm/°C, 2.2 pm/ μ ε  [122]
2022Li-ion Coin BatteryInternal temperature and strain-11.7 pm/°C, 11.3 pm/°C, 1.04 pm/ μ ε  [112]
2023Li-ion Pouch BatteryInternal temperature and strain 10.3 pm/°C [126]
2020Li-ion Cylindrical BatteryInternal temperature and pressure0.1 °C, 0.14 bar−2.7 pm/bar (MOF), −0.3 pm/bar (SMF), 10 pm/°C (SMF), 10 pm/°C (MOF) [124]
2021Sodium-ion Cylindrical BatteryInternal temperatures and pressure0.1 °C−2.7 pm/bar (MOF), −0.3 pm/bar (SMF) [125]
2019Li-ion Pouch BatteryElectrolyte RI-- [127]
2022Aqueous Zn-ion BatteriesElectrolyte RI-- [110]
2024Lithium Metal BatteryElectrolyte RI-- [111]
2021Li-ion Cylindrical BatteryInternal temperature and electrolyte RI6 × 10−5 RIU−18 nm/RIU, 10.1 pm/°C [90]
2016Li-ion Pouch BatterySOC-- [119]
2018SupercapacitorsSOC-- [123]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Yu, K.; Chen, W.; Deng, D.; Wu, Q.; Hao, J. Advancements in Battery Monitoring: Harnessing Fiber Grating Sensors for Enhanced Performance and Reliability. Sensors 2024, 24, 2057. https://doi.org/10.3390/s24072057

AMA Style

Yu K, Chen W, Deng D, Wu Q, Hao J. Advancements in Battery Monitoring: Harnessing Fiber Grating Sensors for Enhanced Performance and Reliability. Sensors. 2024; 24(7):2057. https://doi.org/10.3390/s24072057

Chicago/Turabian Style

Yu, Kaimin, Wen Chen, Dingrong Deng, Qihui Wu, and Jianzhong Hao. 2024. "Advancements in Battery Monitoring: Harnessing Fiber Grating Sensors for Enhanced Performance and Reliability" Sensors 24, no. 7: 2057. https://doi.org/10.3390/s24072057

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop