Next Article in Journal
Analysis of Deep Learning-Based Phase Retrieval Algorithm Performance for Quantitative Phase Imaging Microscopy
Next Article in Special Issue
Broadband Acoustic Sensing with Optical Nanofiber Couplers Working at the Dispersion Turning Point
Previous Article in Journal
Mapping of the Acoustic Environment at an Urban Park in the City Area of Milan, Italy, Using Very Low-Cost Sensors
Previous Article in Special Issue
An Ultra-High-Resolution Bending Temperature Decoupled Measurement Sensor Based on a Novel Core Refractive Index-like Linear Distribution Doped Fiber
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Communication

Theoretical and Experimental Studies of Micro-Surface Crack Detections Based on BOTDA

1
College of Information and Control Engineering, Shenyang Jianzhu University, Shenyang 110168, China
2
Department of Civil and Materials Engineering, University of Illinois at Chicago, 842 W Taylor St., Chicago, IL 60607, USA
*
Author to whom correspondence should be addressed.
Sensors 2022, 22(9), 3529; https://doi.org/10.3390/s22093529
Submission received: 23 March 2022 / Revised: 2 May 2022 / Accepted: 3 May 2022 / Published: 6 May 2022
(This article belongs to the Special Issue Micro-/Nano-Fiber Sensors and Optical Integration Devices)

Abstract

:
Micro-surface crack detection is important for the health monitoring of civil structures. The present literature review shows that micro-surface cracks can be detected by the Brillouin scattering process in optical fibers. However, the existing reports focus on experiment research. The comparison between theory and experiment for Brillouin-scattering-based optical sensors is rarely reported. In this paper, a distributed optical fiber sensor for monitoring micro-surface cracks is presented and demonstrated. In the simulation, by using finite element methods, an assemblage of a three-dimensional beam model for Brillouin optical time domain analysis (BOTDA) was built. The change in Brillouin frequency (distributed strain) as a function of different cracks was numerically investigated. Simulation results indicate that the amplitudes of the Brillouin peak increase from 27 με to 140 με when the crack opening displacement (COD) is enlarged from 0.002 mm to 0.009 mm. The experiment program was designed to evaluate the cracks in a beam with the length of 15 m. Experimental results indicate that it is possible to detect the COD in the length of 0.002~0.009 mm, which is consistent with the simulation data. The limitations of the proposed sensing method are discussed, and the future research direction is prospected.

1. Introduction

Optical fiber sensors have been widely used in structural health monitoring for judging the growth process of cracks in buildings, bridges and other forms of civil infrastructure [1,2,3,4,5,6]. Compared with a traditional electrical sensor, the optical fiber sensor has a lot of advantages, such as anti-corrosion resistance, anti-electromagnetic interference, and high sensitivity. Based on these advantages, optical fiber sensors have been attaining a lot of interest from researchers and engineers in the past few years [7,8,9,10,11].
At present, there are three main optical fiber sensors for structural health monitoring: the local optical fiber sensor, the quasi-distributed optical fiber sensor, and the distributed optical fiber sensor [12,13,14,15,16]. In the aspect of the local optical fiber sensor, Chen H presented an extrinsic Fabry–Perot interferometric (EFPI) with dual cavities to measure the pressure (0.1–3 MPa) and temperature (20–350 °C) [17]. Ghildiyal, S designed an FPI pressure sensor with a copper–beryllium alloy (CBA) diaphragm [18]. A sensitivity of more than 1 µm/bar was obtained. In the aspect of the quasi-distributed optical fiber sensor, Liu, M prepared a fiber Bragg grating (FBG) pressure sensor and encapsulated it in polymer. A sensitivity of 51.296 pm/MPa was experimentally demonstrated in the range of 0~15.5 MPa [19]. Guo, G proposed a multiplexed FBG to detect the strain at discrete locations in the fabric. The average lower error rate of 5.9% can be achieved [20]. In the aspect of the distributed optical fiber sensor, Scarella, A presented an optical fiber sensor based on stimulated Brillouin scattering to measure the strain in the bridge model, where the strain increased monotonously with the crack length [21]. Oskoui, E detected five locations of cracks by using Brillouin scattering [22]. Generally speaking, local optical fiber sensors have been limited to a short distance. Quasi-distributed sensors rely on the prior knowledge of crack location. Distributed optical fiber sensors have the advantages of low cost, long distance and, independence from the prior knowledge of crack position. Among them, the use of the distributed optical fiber sensor is a common method for detecting strain caused by crack-growth damages. The method is based on Brillouin scattering, which provides the local strain information in each spatial resolution along the optical fiber. The interaction between light and phones results in Brillouin frequency, which is linearly dependent on strain. This strain will increase as the crack grows. By measuring the Brillouin frequency shift in the optical fiber, the strain data can be acquired, and the crack growth can be identified. In recent years, some significant progress has been made with the development of measurement technology of Brillouin frequency. Yang, D studied a plastic optical fiber sensing technology combining a signal processing method to detect cracks [23]. The results show that the remarkable resemblance in terms of cracks can be identified. Cheng, L designed a high-precision fiber macro-bending loss crack sensor [24]. The macro-bend loss is linearly related to the crack length. Song, Q analyzed a deep learning method and used it for micro-crack detection [25]. The result shows that the crack width of nearly 23 μm can be accurately monitored. Bassil, A presented a multilayer optical fiber to monitor the opening crack in concrete structures [26], with which a relative error as low as 2% can be obtained. This research contributes some novel methods to structural health monitoring. However, most reports are only based on experimental analysis. Less reports focus on the comparison of theory and experiment. Even in the existing theory of crack detection, only the strain exponential model is discussed [26], and it cannot accurately describe the relationship between strain and crack growth. The finite element method of optical fiber can improve the accuracy of analysis, but the analyses of crack detection by use of three-dimensional optical fiber models are fewer. In addition, the tolerance of optical fiber is worth studying.
In this paper, a three-dimensional beam finite element analysis model is proposed, and the strain as a function of crack opening displacement (COD) is analyzed. An experiment program with two CODs, including Brillouin optical time domain analysis (BOTDA) for distributed detection of strain and cracks, is established to evaluate the feasibility. The COD detection range is studied by analyzing the non-linearity of optical fiber.

2. Model Analysis

Accordingly, the present study proposed an optical fiber sensor adhered on a crack substrate (steel beam). Figure 1 shows the distribution optical fiber sensor with two cracks. The theoretical model contains two cracks (COD = 2δ1 and COD = 2δ2) along the optical fiber at Z = Z1 = 4.4 m and Z = Z2 = 10.6 m. The fiber core diameter is 9 μm, the fiber cladding is 125 μm, and the fiber coating is 250 μm.
The system based on Brillouin scattering is achieved by scanning the frequency shift in the optical fiber. External strain applied to the optical fiber can lead to Brillouin frequency shift, and the Brillouin frequency shift ΩB(Z) as a function of strain is expressed by [27]
ΩB(Z) = Δε(Z) + CTΔT(Z)
where Δε(Z) and ΔT(Z) refer to the change in strain and temperature, and = 0.05 MHz/με and CT = 1 MHz/°C are Brillouin factors for strain and temperature, respectively.
The strain with the crack in the distributed optical fiber is expressed by [28]
ε ( z ) = { δ 1 β exp [ β ( Z Z 1 ) ] + δ 2 β exp [ β ( Z Z 2 ) ] Z < Z 1 < Z 2 δ 1 β exp [ β ( Z Z 1 ) ] + δ 2 β exp [ β ( Z Z 2 ) ] Z 1 < Z < Z 2 δ 1 β exp [ β ( Z Z 1 ) ] + δ 2 β exp [ β ( Z Z 2 ) ] Z 1 < Z 2 < Z
where β is the shear lag factor, which was 25/m consulted in the reference [29]. Figure 2 shows the finite element model in which the SMF28 optical fiber was used. The region may have to be divided into 23,546 mesh elements. The steel beam is a rigid body, so it was not used in the model. The cracks were applied to the bottom surface of the glue layer. Since the crack is axisymmetric, the middle section was built in the COMSOL software. The size parameter is Hg = 6 mm, Wg = 10 mm, and Lg = 106 mm. The mechanical properties of the materials can be consulted in the reference [28].
In order to evaluate the feasibility of the presented BOTDA sensor in the long beam with cracks, an experimental program was designed. Figure 3 shows a test bed, which was fabricated to apply the bending test in a 15 m length of beam. The beam was comprised of three sections at the length of 4.4 m, 6.2 m, and 4.4 m, and had two spliced points. The three sections of the beam were connected by bolts and plates. The beam was supported at two points with the span, and the force was applied at the ends. The damage could be fabricated in each splice joint through tightening or loosening the bolts at the plates. In order to monitor the crack opening displacements caused by loosening the bolts, an arch FBG displacement sensor was used. The detailed fabrication method can be consulted in the reference [30]. A single-mode optical fiber (SMF-28) was used as the sensing optical fiber over the beam. In order to maintain stability, the optical fiber was adhered by glue (epoxy resin) onto the top surface of the beam. An available BOTDA measuring system (Neubrex NBX-6055) was used for measuring the strain of the optical fiber. The BOTDA measuring system employs two light sources, including a pump light and a probe light. They transmit in two opposite directions via the separated optical fiber. The sampling interval and spatial resolution were set as SI = 5 cm and SR = 10 cm. The dynamic measurement was conducted at 26 Hz speed (26 measurements/s).
Table 1 shows the material parameters of the single-mode optical fiber (single-mode transmission) which is considered a distributed sensor.

3. Results and Discussion

The theoretical and experimental results were studied and compared. For the simulation model, the strain distribution in the optical fiber with two cracks was studied. The distributed optical fiber sensor were assumed to undergo 49 N, 98 N, 196 N, and 392 N, and the crack opening displacements (CODs) were set as 0.002 mm, 0.006 mm, 0.009 mm, and 0.011 mm. Figure 4a shows the Brillouin frequency shift by numerical integration. It can be seen that when the applied force was increased from 49 N to 392 N, the strain in the middle section increased from 10.3 με to 60 με. Two distinct peaks appeared in the Brillouin frequency spectrum due to the two cracks. The amplitudes of the Brillouin peaks increased from 27 με to 140 με when the CODs at the crack’s location rose from 0.002 mm to 0.011 mm. In order to verify the theoretical analysis, distributions of strain were measured for the four CODs ranging from 0.002 mm to 0.011 mm. Figure 4b shows the distributions of strain along the length of the optical fiber from the experiments after filtering out the noise.
It seems that the theoretical results from Figure 4a and the experimental results from Figure 4b are in line with the location of the crack. However, the difference between amplitudes of strain in no-crack and crack regions can be observed when the simulation results are compared with the experimental results. Compared with the actual measurement value, the theoretical simulations underestimate the amplitudes of strain. Figure 5a,b show the difference, respectively. One of the reasons for this difference can be attributed to the crack displacement of the optical fiber. When the crack occurs, the displacement was detected by FBG. However, the actual displacement of the optical fiber was larger than that detected by FBG. Because the optical fiber was not completely attached to the beam surface, there was still a gap above the beam surface. Therefore, the strain was larger than that in the experiment due to the longer crack opening displacement. The other reason is attributed to the fluctuation of the Brillouin scattering gain spectrum. Sometimes, the inconsistencies associated with the probe light and pump light may occur due to the noise level in many measurements.
In order to ensure that the optical fiber can be re-used, the experiment was conducted for a second time. Figure 6 shows the comparison of the peaks in the crack strain region for the first time and second time. It was seen that the strain decreases at first and then increases along the crack region. This is attributed to the non-linearity of Young’s modulus of the optical fiber [31]. The strain response of optical fiber under continuous loading can be divided into two phases. In the first phase, the optical fiber can exhibit full strain recovery. In the second phase, residual strain occurs in the optical fiber and increases when the strain exceeds a certain threshold value. Figure 7 shows the relation between stress σ and strain ε for distributed optical fiber adhered to the beam surface. When the optical fiber performs in the red region (OA line), the stress and strain exhibits a linear trend. When the strain is larger than the yield stress, the optical fiber performs under a non-linear condition (AB line). In the two ranges of OA and AB, the optical fiber can return to its original memory shape once the stress is released. When the stress exerted upon the optical fiber reaches up to the value of spot B, the optical fiber is physically damaged and cannot return to its original shape, even in the no-stress condition. There will be plastic strain (OC line). In the experiment, due to the excess deformation of the optical fiber, the optical fiber was stretched again, and the stress in the central position decreased. Therefore, the crack below 0.009 mm can be used for the distributed optical fiber through testing the optical fiber characteristic.

4. Conclusions

This paper reports a method for COD determination based on calculating the Brillouin frequency peak. The work involved a theoretical simulation as well as an experimental investigation. In the theoretical perspective, FEM was used for determining the distributed strain along the optical fiber. The simulation results indicate that the Brillouin peak frequency increases from 27 με to 140 με with an increase in COD from 0.002 mm to 0.009 mm. In the experimental perspective, a 15 m length of steel beam was designed to realize the distributed strain measurement and simulate crack detection. The experimental results are very consistent with the simulation data. In addition, the nonlinear tolerance of the proposed optical fiber was analyzed.
In summary, the proposed Brillouin distributed optical fiber sensor is applicable for detection and monitoring of crack damage in steel beams, with the advantages of long-distance monitoring, low cost, and simple structure. However, this work is in its initial stage, and studies some basic problems in theoretical and experimental aspects. In the future, some research directions require more attention. For example, firstly, optimizing characteristics and practical application. Secondly, the stress–strain non-linearity of the optical fiber core needs to be studied deeply. Thirdly, the influence of the protective coating and glue on strain transferring to the core is a factor worth considering. Fourthly, the range extension of crack detection needs to be further investigated. Finally, it is necessary to consider the error of the optical fiber due to environmental disturbances.

Author Contributions

Conceptualization, B.Y.; methodology, software, hardware, validation, and data curation, M.M.; formal analysis, investigation, and resources, Y.Y.; writing—original draft preparation, B.Y.; writing—review and editing, F.A. and M.M.; supervision and project administration, Y.Y. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by China Scholarship Council (CSC), grant number (201908210075).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

The authors acknowledge the partial financial support from the China Scholarship Council (CSC), project 201908210075.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Joe, H.E.; Yun, H.; Jo, S.H.; Jun, M.; Min, B.K. A review on optical fiber sensors for environmental monitoring. Int. J. Precis. Eng. Manuf.-Green Technol. 2018, 5, 173–191. [Google Scholar] [CrossRef]
  2. Li, J.; Yan, H.; Dang, H.; Meng, F. Structure design and application of hollow core microstructured optical fiber gas sensor: A review. Opt. Laser Technol. 2021, 135, 106658. [Google Scholar] [CrossRef]
  3. Li, J.; Chen, G.; Meng, F. A fiber-optic formic acid gas sensor based on molybdenum disulfide nanosheets and chitosan works at room temperature. Opt. Laser Technol. 2022, 150, 107975. [Google Scholar] [CrossRef]
  4. Wang, X.; Ansari, F.; Meng, D.; Bao, T. Acousto-opto-mechanical theory for polarization maintaining optical fibers in Brillouin based sensing. Opt. Fiber Technol. 2015, 21, 170–175. [Google Scholar] [CrossRef]
  5. Motamedi, M.H.; Feng, X.; Zhang, X.; Sun, C.; Ansari, F. Quantitative investigation in distributed sensing of structural defects with Brillouin optical time domain reflectometry. J. Intell. Mater. Syst. Struct. 2013, 24, 1187–1196. [Google Scholar] [CrossRef]
  6. Meng, D.; Ansari, F. Damped fiber optic low-frequency tiltmeter for real-time monitoring of structural displacements. Meas. Sci. Technol. 2013, 24, 125106. [Google Scholar] [CrossRef]
  7. Pevec, S.; Donlagic, D. Multiparameter fiber-optic sensors: A review. Opt. Eng. 2019, 58, 072009.1–072009.26. [Google Scholar] [CrossRef] [Green Version]
  8. Zhao, Y.; Zhao, J.; Zhao, Q. Review of no-core optical fiber sensor and applications. Sens. Actuators A Phys. 2020, 313, 112160. [Google Scholar] [CrossRef]
  9. Yap, S.H.K.; Chan, K.K.; Zhang, G.; Tjin, S.C.; Yong, K. Carbon dot-functionalized interferometric optical fiber sensor for detection of ferric ions in biological samples. ACS Appl. Mater. Interfaces 2019, 11, 28546–28553. [Google Scholar] [CrossRef]
  10. Wu, P.; Han, L.; Zeng, N.; Li, F. FMD-Yolo: An efficient face mask detection method for COVID-19 prevention and control in public. Image Vis. Comput. 2022, 117, 104341. [Google Scholar] [CrossRef]
  11. Zeng, N.; Wu, P.; Wang, Z.; Han, L.; Liu, W.; Liu, X. A small-sized object detection oriented multi-scale feature fusion approach with application to defect detection. IEEE Trans. Instrum. Meas. 2022, 71, 1–14. [Google Scholar] [CrossRef]
  12. Qi, X.; Wang, S.; Jiang, J.; Liu, K.; Wang, X.; Yang, Y.; Liu, T. Fiber optic Fabry-Perot pressure sensor with embedded MEMS micro-cavity for ultra-high pressure detection. J. Lightwave Technol. 2018, 37, 2719–2725. [Google Scholar] [CrossRef]
  13. Hong, C.; Yuan, Y.; Yang, Y.; Zhang, Y.; Abro, Z.A. A simple FBG pressure sensor fabricated using fused deposition modelling process. Sens. Actuators A Phys. 2019, 285, 269–274. [Google Scholar] [CrossRef]
  14. Campanella, C.; Cuccovillo, A.; Campanella, C.; Yurt, A. Fibre Bragg grating based strain sensors: Review of technology and applications. Sensors 2018, 18, 3115. [Google Scholar] [CrossRef] [Green Version]
  15. Su, H.; Wen, Z.; Li, P. Experimental study on PPP-BOTDA-based monitoring approach of concrete structure crack. Opt. Fiber Technol. 2021, 65, 102590. [Google Scholar] [CrossRef]
  16. Ye, H.; Liu, J.; Zhou, Y.; Huang, R.; Liu, C. Monitoring of Crack Opening Displacement of Steel Structure by PPP-BOTDA-Distributed Fiber Optical Sensors: Theory and Experiment. Eng. Fract. Mech. 2022, 262, 108275. [Google Scholar] [CrossRef]
  17. Chen, H.; Chen, Q.; Wang, W.; Zhang, X.; Ma, Z.; Li, Y.; Jing, X.; Yuan, S. Fiber-optic, extrinsic Fabry-Perot interferometric dual-cavity sensor interrogated by a dual-segment, low-coherence Fizeau interferometer for simultaneous measurements of pressure and temperature. Opt. Express 2019, 27, 38744–38758. [Google Scholar] [CrossRef]
  18. Ghildiyal, S.; Balasubramaniam, R.; John, J. Diamond turned micro machined metal diaphragm based Fabry Perot pressure sensor. Opt. Laser Technol. 2020, 128, 106243. [Google Scholar] [CrossRef]
  19. Liu, M.; Wu, Y.; Du, C.; Wang, Z. FBG-Based Liquid Pressure Sensor for Distributed Measurement with a Single Channel in Liquid Environment. IEEE Sens. J. 2020, 20, 9155–9161. [Google Scholar] [CrossRef]
  20. Guo, G.; Hackney, D.; Pankow, M.; Peters, K. Shape reconstruction of woven fabrics using fiber bragg grating strain sensors. Smart Mater. Struct. 2019, 28, 125081. [Google Scholar] [CrossRef]
  21. Scarella, A.; Salamone, G.; Babanajad, S.K.; De, S.A.; Ansari, F. Dynamic Brillouin Scattering–Based Condition Assessment of Cables in Cable-Stayed Bridges. J. Bridge Eng. 2017, 22, 04016130. [Google Scholar] [CrossRef]
  22. Oskoui, E.A.; Taylor, T.; Ansari, F. Method and monitoring approach for distributed detection of damage in multi-span continuous bridges. Eng. Struct. 2019, 189, 385–395. [Google Scholar] [CrossRef]
  23. Yang, D.; Li, D.; Kuang, K.S.C. Fatigue crack monitoring in train track steel structures using plastic optical fiber sensor. Meas. Sci. Technol. 2017, 28, 105103. [Google Scholar] [CrossRef] [Green Version]
  24. Cheng, L.; Li, Y.; Ma, Y.; Tong, F. The sensing principle of a new type of crack sensor based on linear macro-bending loss of an optical fiber and its experimental investigation. Sens. Actuators A Phys. 2018, 272, 53–61. [Google Scholar] [CrossRef]
  25. Song, Q.; Zhang, C.; Tang, G.; Ansari, F. Deep learning method for detection of structural microcracks by Brillouin scattering based distributed optical fiber sensors. Smart Mater. Struct. 2020, 29, 075008. [Google Scholar] [CrossRef]
  26. Bassil, A.; Chapeleau, X.; Leduc, D.; Abraham, O. Concrete Crack Monitoring Using a Novel Strain Transfer Model for Distributed Fiber Optics Sensors. Sensors 2020, 20, 2220. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  27. Nazarian, E.; Ansari, F.; Zhang, X.; Taylor, T. Detection of Tension Loss in Cables of Cable-Stayed Bridges by Distributed Monitoring of Bridge Deck Strains. J. Struct. Eng. 2016, 142, 04016018. [Google Scholar] [CrossRef]
  28. Meng, D.; Ansari, F. Interference and differentiation of the neighboring surface microcracks in distributed sensing with PPP-BOTDA. Appl. Opt. 2016, 55, 9782–9790. [Google Scholar] [CrossRef]
  29. Meng, D.; Farhad, A.; Xin, F. Detection and monitoring of surface micro-cracks by PPP-BOTDA. Appl. Opt. 2015, 54, 4972–4978. [Google Scholar] [CrossRef]
  30. Bassam, A.; Iranmanesh, A.; Ansari, F. A simple quantitative approach for post earthquake damage assessment of flexure dominant reinforced concrete bridges. Eng. Struct. 2011, 33, 3218–3225. [Google Scholar] [CrossRef]
  31. Daghash, S.M.; Ozbulut, O.E. Characterization of superelastic shape memory alloy fiber-reinforced polymer composites under tensile cyclic loading. Mater. Des. 2016, 111, 504–512. [Google Scholar] [CrossRef]
Figure 1. Distribution optical fiber sensor with two cracks.
Figure 1. Distribution optical fiber sensor with two cracks.
Sensors 22 03529 g001
Figure 2. FEM model and mesh dividing of optical fiber coated by glue.
Figure 2. FEM model and mesh dividing of optical fiber coated by glue.
Sensors 22 03529 g002
Figure 3. Schematic of experiment setup for detecting cracks with long distributed optical fiber sensors.
Figure 3. Schematic of experiment setup for detecting cracks with long distributed optical fiber sensors.
Sensors 22 03529 g003
Figure 4. Strain curves with (a) theoretical and (b) experimental results for COD = 0.002 mm, 0.006 mm, 0.009 mm, and 0.011 mm.
Figure 4. Strain curves with (a) theoretical and (b) experimental results for COD = 0.002 mm, 0.006 mm, 0.009 mm, and 0.011 mm.
Sensors 22 03529 g004
Figure 5. (a) Comparison of strain between theoretical and experimental results for F = 49 N, 98 N, 196 N, and 392 N. (b) Comparison of strain between theoretical and experimental results for COD = 0.002 mm, 0.006 mm, 0.009 mm, and 0.011 mm.
Figure 5. (a) Comparison of strain between theoretical and experimental results for F = 49 N, 98 N, 196 N, and 392 N. (b) Comparison of strain between theoretical and experimental results for COD = 0.002 mm, 0.006 mm, 0.009 mm, and 0.011 mm.
Sensors 22 03529 g005
Figure 6. Comparison of first-time and second-time measurement strains in crack region.
Figure 6. Comparison of first-time and second-time measurement strains in crack region.
Sensors 22 03529 g006
Figure 7. Non-linearity of distributed optical fiber.
Figure 7. Non-linearity of distributed optical fiber.
Sensors 22 03529 g007
Table 1. Mechanical parameters of distributed optical fiber.
Table 1. Mechanical parameters of distributed optical fiber.
MaterialYoung’s Modulus (MPa)Poisson’s Ratio
Fiber core and cladding (silicon dioxide)72,0000.2
Fiber coating (acrylate)4.170.48
Glue (epoxy resin)40000.34
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Yuan, B.; Ying, Y.; Morgese, M.; Ansari, F. Theoretical and Experimental Studies of Micro-Surface Crack Detections Based on BOTDA. Sensors 2022, 22, 3529. https://doi.org/10.3390/s22093529

AMA Style

Yuan B, Ying Y, Morgese M, Ansari F. Theoretical and Experimental Studies of Micro-Surface Crack Detections Based on BOTDA. Sensors. 2022; 22(9):3529. https://doi.org/10.3390/s22093529

Chicago/Turabian Style

Yuan, Baolong, Yu Ying, Maurizio Morgese, and Farhad Ansari. 2022. "Theoretical and Experimental Studies of Micro-Surface Crack Detections Based on BOTDA" Sensors 22, no. 9: 3529. https://doi.org/10.3390/s22093529

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop