Interdigitated and Wave-Shaped Electrode-Based Capacitance Sensor for Monitoring Antibiotic Effects

1
Department of Health Science and Technology, GAIHST, Gachon University, Incheon 21999, Korea
2
Department of Biomedical Engineering, Gachon University, 191 Hambakmoero, Yeonsu-gu, Incheon 21936, Korea
3
Department of Electronic Engineering, Gachon University, 1342 Seongnamdaero, Seongnam-si, Gyeonggi-do 13120, Korea
*
Authors to whom correspondence should be addressed.
Sensors 2020, 20(18), 5237; https://doi.org/10.3390/s20185237
Submission received: 12 August 2020 / Revised: 11 September 2020 / Accepted: 11 September 2020 / Published: 14 September 2020
(This article belongs to the Special Issue Advanced Biosensors for Bacterial Detection)

Abstract

:
Label-free and real-time monitoring of the bacterial viability is essential for the accurate and sensitive characterization of the antibiotic effects. In the present study, we investigated the feasibility of the interdigitated and wave-shaped electrode (IWE) for monitoring the effect of tetracycline or kanamycin on Staphylococcus aureus (S. aureus) and methicillin-resistant S. aureus (MRSA). The electrical impedance spectra of the IWE immersed in the culture media for bacterial growth were characterized in a frequency range of 10 Hz to 1 kHz. The capacitance index (CI) (capacitance change relevant with the bacterial viability) was used to monitor the antibiotic effects on the S. aureus and MRSA in comparison to the traditional methods (disk diffusion test and optical density (OD) measurement). The experimental results showed that the percentage of change in CI (PCI) for the antibiotic effect on MRSA was increased by 51.58% and 57.83% in kanamycin and control, respectively. In contrast, the PCI value decreased by 0.25% for tetracycline, decreased by 52.63% and 37.66% in the cases of tetracycline and kanamycin-treated S. aureus, and increased 2.79% in the control, respectively. This study demonstrated the feasibility of the IWE-based capacitance sensor for the label-free and real-time monitoring of the antibiotic effects on S. aureus and MRSA.

1. Introduction

Not only new species of multi-drug-resistant bacteria but also super bacteria have been continuously observed due to mutations that confer resistance against the number of antibiotics developed for the prevention and therapy of pathogenic bacterial diseases [1,2]. Staphylococcus aureus (S. aureus) is one of the pathogenic bacteria, which promotes infections by producing virulence factors and causes bacteremia, endocarditis, skin and soft tissue infections, as well as hospital-acquired infections. Under a long-term antibiotic treatment, the bacteria could develop resistance for certain antibiotics [3,4]. The engineered S. aureus such as methicillin-resistant S. aureus (MRSA) are antibiotic-resistant strains and resistive to a diverse spectrum of antibiotics [5,6]. For developing an effective prophylactic vaccine against these pathogenic bacteria, various traditional methods and techniques such as cell viable count, polymerase chain reaction (PCR), and the disk diffusion test were carried out. However, these traditional methods are time consuming and require specific functionalized materials for target detection [7,8,9]. To overcome these disadvantages, high-throughput screening techniques, such as fluorescence-based microplate assay, imaging-based single-cell morphological analysis (SCMA), surface-enhanced Raman spectroscopy (SERS), functionalized PCR, or impedance microbiology has been introduced [10,11,12,13]. These techniques have the advantages of prompt accuracy and sensitive antibiotics analyses in real-time measurements.
For the accurate and sensitive characterization of the effect of antibiotics, electrical impedance microbiology has gained interest in the last few decades due to its real-time and non-destructive monitoring of the bacteria [14,15,16]. The method is performed with two paired electrodes that can be immersed in the culture medium containing the bacteria to detect the electrical conductivity changes in the media based on the bacterial growth or death [17]. The measured electrical parameters such as conductance, capacitance, or interfacial electrode impedance can be analyzed to quantify the bacteria metabolism as well as the effects of the antibiotics [18]. The electrical impedance measurement using miniaturized comb-structured interdigitated microelectrodes (IMEs) has been employed to characterize the electrical properties of microscopic samples [19,20,21].
Using the IME sensor, the sensitivity for the detection of micro-sized specimens was improved when compared with typical macro wires or disk electrodes due to a low ohmic drop, a fast-established steady state, rapid kinetics reactions, and an increased signal-to-noise ratio [22,23,24]. Yang et al. fabricated a capacitance-based IME, consisting of 25 paired electrodes with a width of 15 μm width and spacing for the real-time monitoring of viable Salmonella measurement in a low-frequency range [25]. Jo et al. reported an aptamer-functionalized capacitance sensor array for the real-time detection of bacterial growth and antibiotic susceptibility to gentamycin [26]. Settu et al. developed a gold IME-based impedance sensor to detect Escherichia coli (E. coli) in human urine samples for the diagnosis of urinary tract infection. Additionally, they optimized the measurement frequency to increase the detection sensitivity of the E. coli concentration during growth [27]. However, due to the presence of stronger electric fields at the edge of the rectangular fingers, a typical rectangular-shaped IME has a non-homogenous sensing area over the electrode. To increase the homogeneity of the sensitivity fields resulting in an improved reliability of the electrode sensor, the morphology of the electrode needs to be properly designed to avoid the edge effect of the electric field distribution [28,29]. To this end, we developed the interdigitated and wave-shaped electrode (IWE) that was devoid of any sharp edges, and it was used for the electrical impedance monitoring of the protein or thin-film analysis [30,31].
In this study, we investigated the feasibility of the IWE as a capacitance sensor for label-free and real-time monitoring of the dynamic bacterial growth and the antibiotic effects on bacterial viability. The electrical impedance was measured during the culture of S. aureus or MRSA in the presence of two different types of antibiotics (tetracycline or kanamycin at 30 μg/mL), and the results were compared with the traditional disk diffusion method and OD measurement. Based on the experimental results, we discussed the feasibility of the IWE as a capacitance sensor for the non-destructive and real-time monitoring of the antibiotics effect on the bacteria.

2. Materials and Methods

2.1. Fabrication of IWE Using a Microbial Culture Dish

To detect the electrical impedance of the bacteria, we fabricated the IWE on a glass slide substrate (63 × 16 × 1.1 mm). The substrate was cleaned by ultra-sonication in 70% methanol. Following this, a negative photoresist (DNR L300-30, Dongjin Semichem co., Hwaseong, Korea) was spin-coated onto the substrate and patterned using photolithography to obtain a pattern with a spacing and width of 30 μm on IWE. Subsequently, a conductive layer was deposited on the patterned resist by electron beam evaporation (25 nm Ti and 50 nm Au), and the IWE was fabricated using the lift-off process. The IWE was placed in a modified microbial culture dish (DURAN GLS 80, Schott AG., Mainz, Germany) with an extract, and a sensor port was placed as shown in Figure 1. The terminal pads of the IWE were connected to a portable impedance analyzer (PalmSens4, Palmsens, Houten, The Netherlands).

2.2. Antimicrobial Susceptibility Testing

To check the susceptibility of bacteria to the antimicrobial agents, the Kirby–Bauer disc diffusion method was used according to the Clinical and Laboratory Standard Institute (CLSI) guideline of 2011 [32]. Each bacterial suspension was adjusted based on the McFarland standard value of 0.5 turbidities, swabbed onto Luria–Bertani (LB) broth, and incubated in the presence of antibiotic discs at 37 °C for 18 h. The antibiotics discs used were kanamycin (30 μg/mL) or tetracycline (30 μg/mL) (Liofilchem, Roseto degli Aburzzi, Italy), and the diameters of the inhibition zones were measured to determine the resistance or susceptibility of each isolate to these antibiotics.

2.3. Electrical Capacitance Monitoring

We inoculated 10 mL of MRSA or S. aureus culture of 0.6 optical density (OD) into 1 L of LB media in a cell culture flask along with a magnetic stirrer and incubated under constant stirring (250 rpm) at 37 °C in the thermostat (KRS200D, KARIS inc., Gyeonggi-do, Republic of Korea). During the 24 h incubation period, the capacitance spectra was measured in the frequency range of 10 Hz to 1 kHz for every 2-min time interval. The capacitance index (CI) or impedance magnitude index (ZI) termed for the change in capacitance or impedance was calculated using the following equation:
CI   ( % )   =   | C 0 C mea .   C 0 |   ×   100
ZI   ( % )   =   | | Z | 0 | Z | mea .   | Z | 0 |   ×   100
where Co or |Z|o and Cmea. or |Z|mea. are the capacitance or impedance values measured at the initial time and after the cultivation period, respectively.
To compare the electrical capacitance results obtained using IWE sensor with that of the OD measurement, a sample was obtained using a sterile syringe, and its OD was measured using a spectrophotometer (Optizen POP, NEOGEN inc., Dae-jun, Republic of Korea) for every 2 h during the impedance measurement of 24 h. To check the effects of the antibiotics, 30 μg/mL of tetracycline or kanamycin was added into the culture when the OD of MRSA or S. aureus reached 0.6.

3. Results and Discussion

We evaluated the efficacy of the fabricated IWE for the real-time impedance monitoring of the bacteria by measuring the impedance spectra using different concentrations of NaCl as electrolyte in a frequency range from 10 Hz to 1 kHz, as shown in Figure 2. The electrical impedance characteristic of the electrode was governed by a sinusoidal signal with a frequency lower than 100 kHz applied to the electrodes; the bulk capacitance could be neglected, and the equivalent circuit can be simply designed using only an electrical conductivity of the bulk medium (Rs) and the double-layer capacitance (CPE) in series [33,34].
Table 1 shows the data arrangement of the extrapolated values of the circuit parameters from the fitting results in Figure 2. As the concentration of NaCl was increased from 0 to 1%, the value of Rs decreased, but the increase or decrease in CPE depended on the NaCl concentration. The CPE is represented as T ( j ω ) p , where T and p are the adjusted parameters, and the results indicated the interfacial impedance of electrode, which can be attributed to the capacitive reactance characteristic [35].
Eventually, the designed equivalent circuit was well fitted to the measured impedance spectra of the electrolyte, and a fabricated IWE performance could be utilized for electrical impedance monitoring of the bacteria detection.
For the analysis of the biological effect of antibiotics on MRSA or S. aureus, an antimicrobial susceptibility test was performed using the disc diffusion method based on the CLSI guidelines. The results show that when MRSA or S. aureus were treated with tetracycline and kanamycin at a concentration of 30 μg/mL, the clear zones of inhibition for S. aureus with diameters of 14.66 ± 0.47 mm and 31.46 ± 0.47 mm for kanamycin and tetracycline, respectively were recorded. On the other hand, a clear zone of inhibition for MRSA with a diameter of 10.33 ± 0.47 mm for tetracycline was found, while no effect was seen in case of kanamycin, as shown in Figure 3.
Based on the CLSI interpretative criteria, we confirmed that the MRSA was resistant to tetracycline (CLSI Criteria: Staphylococcus is resistant to tetracycline if the zone of inhibition is <14 mm diameter).
Figure 4 shows the raw data of the capacitance using the normalized capacitance spectrum of MRSA or S. aureus with fitting data using the equivalent circuit model as inserted in Figure 4. We have also shown significant changes in the rate of the normalized capacitance during the bacteria growth observed within the frequency range of 10 Hz to 1 kHz. Significant changes occurred at a frequency of 10 Hz for MRSA and S. aureus. As shown in Figure 4, the effect of the antibiotics on the bacterial growth curve was estimated using the OD at 595 nm and the normalized capacitance depending on the low-frequency range. Impedance-based detection methods have been used in microbiology to measure the conductivity of the medium using a paired interdigitated electrode submerged in the inoculated medium at a fixed frequency range of 10 Hz to 1 kHz [36,37].
Table 2 shows the extrapolated values of the equivalent circuit parameters from the fitting results in Figure 4. After the S. aureus or MRSA grew over a 24-hour incubation period, the value of CPE-T indicates that the capacitance increased, but the increase or decrease in Rs or CPE-p is dependent on the bacterial growth. Finally, the designed equivalent circuit was fitted to the measured impedance and capacitance spectra of the bacteria growth, and it was confirmed that the IWE performance could be utilized for electrical impedance monitoring of the antibiotic effects on the bacteria detection.
From the comparison of the optical density measurement (OD at 595 nm) with the CI at 10 Hz for MRSA and S. aureus as shown in Figure 5a,b, the average of the value (n = 3) and standard error was measured during the culture. We observed a significant change in the CI at a fixed frequency of 10 Hz for MRSA or S. aureus, respectively. The CI at 10 Hz for MRSA was 13.49 ± 1.62 at 8 h of incubation, the corresponding OD value at the same time point was 0.68 ± 0.08, and for S. aureus, the CI at 10 Hz of 12.01 ± 1.12 and the corresponding OD value was 0.69 ± 0.07.
Figure 6 depicts the quantified effect of antibiotics on MRSA and S. aureus using capacitive monitoring vs. OD measurement. The results indicated that when MRSA was treated with 30 μg/mL of tetracycline or kanamycin at 8 h, the CI at 10 Hz was increased from 9.51% to 15.01% and from 10.41% to 15.78% for kanamycin and control, and it was decreased from 11.88% to 11.85% for tetracycline, respectively. The PCI value was increased by 51.58% and 57.83% for kanamycin and control, while it was decreased by 0.25% for tetracycline, respectively. The measured OD value was increased by 63.6%, 70.1%, and 75.3% for tetracycline, kanamycin, and control, respectively. The PCI for the antibiotic effect on bacteria was calculated using the following equation:
PCI   ( % )   =   | C 8 h C 24 h .   C 8 h |   ×   100
where C8h and C24h. are the CI values measured at the antibiotic injection time point and then at the end of the cultivation period, respectively.
The CI at 10 Hz for the tetracycline or kanamycin-treated S. aureus was decreased from 10.43% to 4.94% at 10 Hz for tetracycline, decreased from 10.7% to 6.67% for kanamycin, and increased from 11.81% to 12.14% for the control. The PCI value decreased 52.63% for tetracycline-treated S. aureus, decreased 37.66% for kanamycin, and increased 2.79% for the control. The measured OD value decreased 31.25% for tetracycline, increased 1.12% for kanamycin, and increased 88.4% for the control, respectively.
Therefore, the effect of tetracycline or kanamycin on S. aureus was seen to vary depending on the effect of the antibiotics for a measurement period of 24 h. However, there were minimal changes in the OD or capacitive monitoring values for the MRSA treated with antibiotics for 24 h compared to the control group due to their resistance toward antibiotics. Assuming that the conductivity of medium changes due to the metabolism and growth of the bacteria in the media, the changes occurring in the CI is dependent on the bacterial growth under the effect of the antibiotics.
Based on these results, we demonstrated that the label-free and real-time bacteria impedance-monitoring platform made with the developed IWE placed in the microbial culture dish is feasible for the electrical capacitance-based monitoring of the microbial viability. The efficiency and the sensitivity of the IWE was demonstrated by evaluating the selective growth of either MRSA or S. aureus under the influence of the antibiotics depending on the frequency range. Therefore, when the developed IWE is placed in the microbial culture, it can be utilized as an impedance analyzer and can be potentially applied in pharmaceutical, cosmetics, agriculture, or food industries as a commercial product.

4. Conclusions

In this study, we investigated the feasibility of the IWE-based capacitance sensor for the label-free and real-time monitoring of the antibiotic effects on the bacterial viability. The electrical characteristics of the fabricated IWE were explained by fitting the designed equivalent circuit model to the measured impedance spectra of the sensor. The CI (change in capacitance value) of the IWE was derived for monitoring the bacteria growth and the antibiotic effects on the bacterial viability. The monitoring of CI using the IWE sensor was comparable with the experimental results of the typical disk diffusion test and the OD measurement. Thus, it was concluded that the IWE-based capacitance sensor is feasible for label-free and real-time monitoring of not only the bacterial growth but also the antibiotic effects on the bacterial viability.

Author Contributions

J.P. performed the experiments for the electrical engineering part and wrote the manuscript. Y.L. performed the biological experiments. Y.H. conceptualized the experiments. S.C. provided support to procure all the experimental materials and supervised the work. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the National Research Foundation of Korea, Republic of Korea (Grant No. NRF 2018M3A9F1023690, 2019R1A2C1088680), and by the GRRC program of Gyeonggi province [GRRC-Gachon2020(B01), AI-based Medical Image Analysis].

Conflicts of Interest

The authors declare that they have no competing interest.

References

  1. Upadhyay, R.K. Emergence of drug resistance in microbes, its dissemination and target modification of antibiotics: A life threatening problem to human society. Int. J. Pharm. Biol. Res. 2011, 2, 110–216. [Google Scholar]
  2. Mai, B.; Wang, X.; Liu, Q.; Leung, A.W.; Wang, X.; Xu, C.; Wang, P. The Antibacterial Effect of Sinoporphyrin Sodium Photodynamic Therapy on Staphylococcus aureus Planktonic and Biofilm Cultures. Lasers Surg. Med. 2010, 9, 1579–1590. [Google Scholar]
  3. Hempel, K.; Pané-Farré, J.; Otto, A.; Sievers, S.; Hecker, M.; Becher, D. Quantitative Cell Surface Proteome Profiling for SigB-Dependent Protein Expression in the Human Pahogen Staphylococcus aureus via Biotinylation Approach. J. Proteome Res. 2010, 9, 1579–1590. [Google Scholar] [CrossRef] [PubMed]
  4. Abeyrathne, C.D.; Huynh, D.H.; Mcintire, T.W.; Nguyen, T.C.; Nasr, B.; Zantomio, D.; Chana, G.; Abbott, I.; Choong, P.; Catton, M.; et al. Lab on a chip sensor for rapid detection and antibiotic resistance determination of Staphylococcus aureus. Analyst 2016, 141, 1922–1929. [Google Scholar] [CrossRef] [PubMed]
  5. Harada, D.; Nakaminami, H.; Miyajima, E.; Sugiyama, T.; Sasai, N.; Kitamura, Y.; Tamura, T.; Kawakubo, T.; Noguchi, N. Change in genotype of methicillin-resistant Staphylococcus aureus (MRSA) affects the antibiogram of hospital-acquired MRSA. J. Infect. Chemother. 2018, 24, 563–569. [Google Scholar] [CrossRef]
  6. Gill, S.R.; Fouts, D.E.; Archer, G.L.; Mongodin, E.F.; Devoy, R.T.; Ravel, J.; Paulsen, I.T.; Kolonay, J.F.; Brinkac, L.; Beanan, M.; et al. Insights on Evolution of Virulence and Resistance from the Complete Genome Analysis of an Early Methicillin-Resistant Staphylococcus aureus Strain and a Biofilm-Producing Methicillin-Resistant Staphylococcus epidermidis Strain. J. Bacteriol. 2005, 187, 2426–2438. [Google Scholar] [CrossRef] [Green Version]
  7. Kubo, I.; Kajiya, M.; Aramaki, N.; Furutani, S. Detection of Salmonella Enterica in Egg Yolk by PCR on a Microfluidic Disc Device Using Immunomagnetic Beads. Sensors 2020, 20, 1060. [Google Scholar] [CrossRef] [Green Version]
  8. Nabti, L.Z.; Sahli, F.; Ngaiganam, E.P.; Radji, N.; Mezaghcha, W.; Lupande-Mwenebitu, D.; Baron, S.A.; Rolain, J.; Diene, S.M. Development of real-time PCR assay allowed describing the first clinical Klebsiella pneumonia isolate harboring plasmid-mediated colistin resistance mcr-8 gene in Algeria. J. Glob. Antimicrob. Resist. 2020, 20, 266–271. [Google Scholar] [CrossRef]
  9. Boix-Lemonche, G.; Lekka, M.; Skerlavaj, B. A Rapid Fluorescence-Based Microplate Assay to Investigate the Interaction of Membrane Active Antimicrobial Peptides with Whole Gram-Positive Bacteria. Antibiotics 2020, 9, 92. [Google Scholar] [CrossRef] [Green Version]
  10. Iriya, R.; Syal, K.; Jing, W.; Mo, M.; Yu, H.; Haydel, S.E.; Wang, S.; Tao, N. Real-time detection of antibiotic activity by measuring nanometer-scale bacterial deformation. J. Biomed. Opt. 2017, 22, 126002. [Google Scholar]
  11. Camerlingo, C.; Meo, G.D.; Lepore, M.; Lisitskiy, M.; Poli, A.; Portaccio, M.; Romano, I.; Donato, P.D. Graphene-Based and Surface-Enhanced Raman Spectroscopy for Monitoring the Physio-Chemical Response of Thermophilic Bacterial Spores to Low Temperatures Exposure. Sensors 2020, 20, 4150. [Google Scholar] [CrossRef] [PubMed]
  12. Clausen, C.H.; Dimaki, M.; Bertelsen, C.V.; Skands, G.E.; Rodriguez-Trujillo, R.; Thomsen, J.D.; Svendsen, W.E. Bacteria Detection and Differentiation Using Impedance Flow Cytometry. Sensors 2018, 18, 3496. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  13. Spina, R.L.; António, D.C.; Desmet, C.; Valsesia, A.; Bombera, R.; Norlén, H.; Lettieri, T.; Colpo, P. Dark Field Microscopy-Based Biosensors for the Detection of E. coli in Environmental Water Samples. Sensors 2019, 19, 4652. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  14. Cady, P.; Dufour, S.W.; Shaw, J.; Kraeger, S.J. Electrical Impedance Measurements: Rapid Method for Detecting and Monitoring Microorganisms. J. Clin. Microbiol. 1978, 7, 265–272. [Google Scholar]
  15. Ur, A.; Brown, D.F.J. Impedance Monitoring of Bacterial Activity. J. Med. Microbiol. 1973, 8, 19–28. [Google Scholar] [CrossRef] [Green Version]
  16. Nahid, M.A.; Campbell, C.E.; Fong, K.S.K.; Barnhill, J.C. An evaluation of the impact of clinical bacterial isolates on epithelial cell monolayer integrity by the electric Cell-Substrate Impedance Sensing (ECIS) method. J. Microbiol. Methods 2020, 169, 105833. [Google Scholar] [CrossRef]
  17. Bancalari, E.; D’Incecco, P.; Sardaro, M.L.S.; Neviani, E.; Pellegrino, L.; Gatti, M. Impedance microbiology to speed up the screening of lactic acid bacteria exopolysaccharide production. Int. J. Food Microbiol. 2019, 306, 108268. [Google Scholar] [CrossRef]
  18. Liu, J.; Jasim, I.; Abdullah, A.; Shen, Z.; Zhao, L.; Dweik, M.; Zhang, S.; Almasri, M. An integrated impedance biosensor platform for detection of pathogens in poultry products. Sci. Rep. 2018, 8, 16109. [Google Scholar] [CrossRef] [Green Version]
  19. Jeong, S.; Lim, J.; Kim, J.; Kim, M.; Lee, J. Label-free electrochemical impedance spectroscopy using a micro interdigitated electrode inside a PCR chip for real-time monitoring. Microsyst. Technol. 2019, 25, 3503–3510. [Google Scholar] [CrossRef]
  20. An, Y.; Jun, T.; Zhang, F.; He, P. Electric cell-substrate impedance sensing (ECIS) for profiling cytotoxicity of cigarette smoke. J. Electroanal. Chem. 2019, 834, 180–186. [Google Scholar] [CrossRef]
  21. Singh, S.; Moudgil, A.; Mishra, N.; Das, S.; Mishra, P. Vancomycin functionalized WO3 thin film-based impedance sensor for efficient capture and highly selective detection of Gram-positive bacteria. Biosen. Bioelectron. 2019, 136, 23–30. [Google Scholar] [CrossRef] [PubMed]
  22. Koklu, A.; Giuliani, J.; Monton, C.; Beskok, A. Rapid and Sensitive Detection of Nanomolecules by an AC Electrothermal Flow Facilitated Impedance Immunosensor. Anal. Chem. 2020, 92, 7762–7769. [Google Scholar] [CrossRef] [PubMed]
  23. Wang, L.; Xue, L.; Guo, R.; Zheng, L.; Wnag, S.; Yao, L.; Huo, X.; Liu, N.; Liao, M.; Li, Y.; et al. Combining impedance biosensor with immunomagnetic separation for rapid screening of Salmonella in poultry supply chains. Poult. Sci. 2020, 99, 1606–1614. [Google Scholar] [CrossRef]
  24. Cheng, Y.; Moura, P.A.R.; Zhenglong, L.; Feng, L.; Arokiam, S.; Yang, J.; Hariharan, M.; Basuray, S. Effect of electrode configuration on the sensitivity of nucleic acid detection in a non-planar, flow-through, porous interdigitated electrode. Biomicrofluidics 2019, 13, 064118. [Google Scholar] [CrossRef] [PubMed]
  25. Yang, L.; Li, Y. Detection of viable Salmonella using microelectrode-based capacitance measurement coupled with immunomagnetic sepration. Microbiol. Methods 2006, 64, 9–16. [Google Scholar] [CrossRef]
  26. Jo, N.; Kim, B.; Lee, S.M.; Oh, J.; Park, I.H.; Lim, K.J.; Shin, J.S.; Yoo, K.H. Aptamer-functionalized capacitance sensors for real-time monitoring of bacterial growth and antibiotic susceptibility. Biosen. Bioelectron. 2018, 102, 164–170. [Google Scholar] [CrossRef]
  27. Settu, K.; Chen, C.; Liu, J.; Chen, C.L. Impedimetric method for measuring ultra-low E. coli concentrations in human urine. Biosen. Bioelectron. 2015, 66, 244–250. [Google Scholar] [CrossRef]
  28. Kuo, Y.C.; Lee, C.K.; Lin, C.T. Improving sensitivity of a miniaturized label-free electrochemical biosensor using zigzag electrodes. Biosen. Bioelectron. 2018, 103, 130–137. [Google Scholar] [CrossRef]
  29. Park, J.; Cho, S. Development of Interdigitated and Chain-Shaped Electrode Array for Electric Cell-Substrate Impedance Sensing. J. Nanosci. Nanotechnol. 2016, 16, 11911–11915. [Google Scholar] [CrossRef]
  30. Park, J.; Kim, J.; Kim, M.H.; Jang, Y.S.; Cho, S. New Parylene Coating System with Real-Time and Non-Destructive Electrical Impedance Monitoring of Parylene Layer. J. Nanosci. Nanotechnol. 2019, 19, 1–5. [Google Scholar] [CrossRef]
  31. Chinnadayyala, S.R.; Park, J.; Kim, Y.H.; Choi, S.H.; Lee, S.-M.; Cho, W.W.; Lee, G.-Y.; Pyun, J.-C.; Cho, S. Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode. Sensors 2019, 19, 5560. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  32. Wayne, P.A.; Clinical and Laboratory Standards Institute. Performance standards for antimicrobial susceptibility testing. Inform. Suppl. 2011, 31, 100–121. [Google Scholar]
  33. Rosati, G.; Cunego, A.; Fracchetti, F.; Casale, A.D.; Scaramuzza, M.; Toni, A.D.; Torriani, S.; Paccagnella, A. Inkjet Printed Interdigitated Biosensor for Easy and Rapid Detection of Bacteriophage Contamination: A Preliminary Study for Milk Processing Control Applications. Chemosensors 2019, 7, 8. [Google Scholar] [CrossRef] [Green Version]
  34. Xu, Y.; Li, C.; Mei, W.; Guo, M.; Yang, Y. Equivalent circuit models for a biomembrane impedance sensor and analysis of electrochemical impedance spectra based on support vector regression. Med. Biol. Eng. Comput. 2019, 57, 1515–1524. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  35. Yagati, A.K.; Park, J.; Cho, S. Reduced Graphene Oxide Modified the Interdigitated Chain Electrode for an Insulin Sensor. Sensors 2016, 16, 109. [Google Scholar] [CrossRef]
  36. Paredes, J.; Becerro, S.; Arizti, F.; Aguinaga, A.; Pozo, J.L.D.; Arana, S. Interdigitated microelectrode biosensor for bacterial biofilm growth monitoring by impedance spectroscopy technique in 96-well microtiter plates. Sens. Actuators B Chem. 2013, 178, 663–670. [Google Scholar] [CrossRef]
  37. Ward, A.C.; Hannah, A.J.; Kendrick, S.L.; Tucker, N.P.; MacGregor, G.; Connolly, P. Identification and characterization of Staphylococcus aureus on low cost screen printed carbon electrodes using impedance spectroscopy. Biosen. Bioelecron. 2018, 110, 65–70. [Google Scholar] [CrossRef]
Figure 1. Schematic representation of the capacitance monitoring system for bacteria using the developed interdigitated and wave-shaped electrode (IWE) with microbial culture platform.
Figure 1. Schematic representation of the capacitance monitoring system for bacteria using the developed interdigitated and wave-shaped electrode (IWE) with microbial culture platform.
Sensors 20 05237 g001
Figure 2. Electrical impedance spectra (a,b) of the IWE measured in different concentrations of NaCl electrolyte. The data points represent the measured (mea.) impedance spectra. The dotted lines represent the impedance spectra fitted (Fit.) using an equivalent circuit model, consisting of the solution resistance (Rs), and a double-layer capacitance (CPE).
Figure 2. Electrical impedance spectra (a,b) of the IWE measured in different concentrations of NaCl electrolyte. The data points represent the measured (mea.) impedance spectra. The dotted lines represent the impedance spectra fitted (Fit.) using an equivalent circuit model, consisting of the solution resistance (Rs), and a double-layer capacitance (CPE).
Sensors 20 05237 g002
Figure 3. Antibiotic susceptibility test of (a) S. aureus or (b) MRSA was performed using discs containing the antibiotics, tetracycline 30 μg/mL (TE30), and kanamycin 30 μg/mL (K30), and by measuring the clear zone (S: susceptible, R: resistive).
Figure 3. Antibiotic susceptibility test of (a) S. aureus or (b) MRSA was performed using discs containing the antibiotics, tetracycline 30 μg/mL (TE30), and kanamycin 30 μg/mL (K30), and by measuring the clear zone (S: susceptible, R: resistive).
Sensors 20 05237 g003
Figure 4. Impedance spectra and capacitance spectra for S. aureus (a,b) and methicillin-resistant S. aureus (MRSA) (c,d) during bacterial growth in Luria–Bertani (LB) medium. The data points represent the measured (mea.) impedance spectra. The dotted lines represent the fitting spectra (Fit.) using an equivalent circuit model, consisting of the solution resistance (Rs) and a double-layer capacitance (CPE).
Figure 4. Impedance spectra and capacitance spectra for S. aureus (a,b) and methicillin-resistant S. aureus (MRSA) (c,d) during bacterial growth in Luria–Bertani (LB) medium. The data points represent the measured (mea.) impedance spectra. The dotted lines represent the fitting spectra (Fit.) using an equivalent circuit model, consisting of the solution resistance (Rs) and a double-layer capacitance (CPE).
Sensors 20 05237 g004
Figure 5. Typical bacterial growth curve measured over a period of 24 h at 595 nm (optical density (OD) = λ595nm) (a), and capacitance index (CI) and impedance magnitude index (ZI) for MRSA and S. aureus at 10 Hz (b,c) (standard error, n = 3).
Figure 5. Typical bacterial growth curve measured over a period of 24 h at 595 nm (optical density (OD) = λ595nm) (a), and capacitance index (CI) and impedance magnitude index (ZI) for MRSA and S. aureus at 10 Hz (b,c) (standard error, n = 3).
Sensors 20 05237 g005
Figure 6. Effect of antibiotics (tetracycline or kanamycin, each of 30 μg/mL) on (a,b) S. aureus or (c,d) MRSA shown by the change in OD at 595 nm or CI at 10 Hz (arrow: antibiotics injection time).
Figure 6. Effect of antibiotics (tetracycline or kanamycin, each of 30 μg/mL) on (a,b) S. aureus or (c,d) MRSA shown by the change in OD at 595 nm or CI at 10 Hz (arrow: antibiotics injection time).
Sensors 20 05237 g006
Table 1. Extrapolated values of the designed equivalent circuit parameters from the fitting results in Figure 2.
Table 1. Extrapolated values of the designed equivalent circuit parameters from the fitting results in Figure 2.
Conc. NaClRsCPE
% T   [ × 10 6   Ω 1   s p ] p
04968.6 ± 107.70.747 ± 0.0260.8639 ± 0.0012
0.00014128.3 ± 5.50.662 ± 0.0010.8714 ± 0.0016
0.0012101.3 ± 8.60.584 ± 0.0030.9044 ± 0.0012
0.011465.1 ± 9.20.632 ± 0.0080.9158 ± 0.0009
0.11401.0 ± 1.60.845 ± 0.0060.9001 ± 0.0001
11363.2 ± 35.31.017 ± 0.0050.8971 ± 0.0021
Table 2. Extrapolated values of the designed equivalent circuit parameters from the fitting results for S. aureus and MRSA in Figure 4.
Table 2. Extrapolated values of the designed equivalent circuit parameters from the fitting results for S. aureus and MRSA in Figure 4.
Time (h)Rs (Ω)CPE
T   [ × 10 6   Ω 1   s p ] p
S. aureus01327 ± 5.41.267 ± 0.0210.861 ± 0.0005
21330 ± 3.51.317 ± 0.0220.860 ± 0.0012
41338 ± 3.81.309 ± 0.0450.865 ± 0.0024
61340 ± 4.21.366 ± 0.0320.863 ± 0.0018
81335 ± 8.51.454 ± 0.0180.858 ± 0.0032
101336 ± 2.41.442 ± 0.0220.860 ± 0.0011
121340 ± 3.51.453 ± 0.0150.859 ± 0.0008
141330 ± 2.61.466 ± 0.0110.858 ± 0.0004
161346 ± 1.41.448 ± 0.0190.859 ± 0.0015
181335 ± 2.31.443 ± 0.0220.859 ± 0.0021
201348 ± 1.61.431 ± 0.0320.861 ± 0.0032
221341 ± 1.91.438 ± 0.0210.861 ± 0.0024
241341 ± 2.21.432 ± 0.0180.861 ± 0.0018
MRSA01343 ± 7.70.997 ± 0.0260.907 ± 0.0012
21323 ± 5.51.089 ± 0.0140.891 ± 0.0021
41341 ± 8.61.170 ± 0.0350.885 ± 0.0015
61330 ± 9.21.208 ± 0.0220.885 ± 0.0005
81335 ± 1.61.276 ± 0.0150.877 ± 0.0007
101326 ± 5.31.359 ± 0.0640.870 ± 0.0011
121312 ± 3.51.376 ± 0.0320.870 ± 0.0010
141318 ± 1.21.353 ± 0.0150.873 ± 0.0021
161313 ± 0.81.374 ± 0.0540.871 ± 0.0014
181314 ± 1.11.377 ± 0.0230.870 ± 0.0011
201310 ± 1.31.345 ± 0.0110.874 ± 0.0015
221311 ± 1.51.367 ± 0.0250.872 ± 0.0019
241314 ± 0.71.376 ± 0.0320.871 ± 0.0013

Share and Cite

MDPI and ACS Style

Park, J.; Lee, Y.; Hwang, Y.; Cho, S. Interdigitated and Wave-Shaped Electrode-Based Capacitance Sensor for Monitoring Antibiotic Effects. Sensors 2020, 20, 5237. https://doi.org/10.3390/s20185237

AMA Style

Park J, Lee Y, Hwang Y, Cho S. Interdigitated and Wave-Shaped Electrode-Based Capacitance Sensor for Monitoring Antibiotic Effects. Sensors. 2020; 20(18):5237. https://doi.org/10.3390/s20185237

Chicago/Turabian Style

Park, Jinsoo, Yonghyun Lee, Youjin Hwang, and Sungbo Cho. 2020. "Interdigitated and Wave-Shaped Electrode-Based Capacitance Sensor for Monitoring Antibiotic Effects" Sensors 20, no. 18: 5237. https://doi.org/10.3390/s20185237