Next Article in Journal
An Innovative Structural Rearrangement in Imine Palladacycle Metaloligand Chemistry: From Single-Nuclear to Double-Nuclear Pseudo-Pentacoordinated Complexes
Previous Article in Journal
An Effective Synthesis of Previously Unknown 7-Aryl Substituted Paullones
Previous Article in Special Issue
Hyperpolarizing DNA Nucleobases via NMR Signal Amplification by Reversible Exchange
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Reconversion of Parahydrogen Gas in Surfactant-Coated Glass NMR Tubes

1
Department of Physics & Astronomy, Rowan University, Glassboro, NJ 08028, USA
2
Advanced Materials & Manufacturing Institute, Rowan University, Glassboro, NJ 08028, USA
3
Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028, USA
4
Department of Biological & Biomedical Sciences, Rowan University, Glassboro, NJ 08028, USA
*
Author to whom correspondence should be addressed.
Undergraduate researcher.
Molecules 2023, 28(5), 2329; https://doi.org/10.3390/molecules28052329
Submission received: 1 February 2023 / Revised: 23 February 2023 / Accepted: 27 February 2023 / Published: 2 March 2023

Abstract

:
The application of parahydrogen gas to enhance the magnetic resonance signals of a diversity of chemical species has increased substantially in the last decade. Parahydrogen is prepared by lowering the temperature of hydrogen gas in the presence of a catalyst; this enriches the para spin isomer beyond its normal abundance of 25% at thermal equilibrium. Indeed, parahydrogen fractions that approach unity can be attained at sufficiently low temperatures. Once enriched, the gas will revert to its normal isomeric ratio over the course of hours or days, depending on the surface chemistry of the storage container. Although parahydrogen enjoys long lifetimes when stored in aluminum cylinders, the reconversion rate is significantly faster in glass containers due to the prevalence of paramagnetic impurities that are present within the glass. This accelerated reconversion is especially relevant for nuclear magnetic resonance (NMR) applications due to the use of glass sample tubes. The work presented here investigates how the parahydrogen reconversion rate is affected by surfactant coatings on the inside surface of valved borosilicate glass NMR sample tubes. Raman spectroscopy was used to monitor changes to the ratio of the (J: 0 → 2) vs. (J: 1 → 3) transitions that are indicative of the para and ortho spin isomers, respectively. Nine different silane and siloxane-based surfactants of varying size and branching structures were examined, and most increased the parahydrogen reconversion time by 1.5×–2× compared with equivalent sample tubes that were not treated with surfactant. This includes expanding the pH2 reconversion time from 280 min in a control sample to 625 min when the same tube is coated with (3-Glycidoxypropyl)trimethoxysilane.

1. Introduction

Hydrogen gas possesses two distinct spin isomers—para (pH2) and ortho (oH2) [1]. Parahydrogen occupies the nuclear singlet state:
S 0 = α β β α 2
with the two hydrogen nuclear spin states (α, β) configured as anti-aligned [2]. Although the wavefunction of molecular H2 consists of electronic, vibrational, rotational, translational, and nuclear spin components, only the rotational and nuclear spin contributions are affected by the exchange of nuclei [3,4]. Furthermore, because the total wavefunction of a homonuclear diatom consisting of two fermions (I = ½ for hydrogen) must be antisymmetric with respect to exchange (to satisfy the Pauli exclusion principle) [5], the two spin isomers of H2 will have either a symmetric rotational wavefunction coupled with an antisymmetric nuclear spin wavefunction, or vice versa [5,6]. For parahydrogen, this means that the anti-aligned nuclear spins experience symmetrical rotational states (e.g., J: 0, 2, 4…), whereas the molecule possesses no net nuclear spin (i.e., silent to magnetic resonance detection). Conversely, orthohydrogen occupies the nuclear triplet spin state:
T + = α α
T 0 = α β + β α 2
T = β β
with three degenerate spin states (net nuclear spin: I = 1) that are symmetric under permutation and antisymmetric rotational quantum numbers (e.g., J: 1, 3, 5…) [2]. As evident by the rotational states, pH2 occupies the lower energy level and is the isomer of preferred abundance at low temperatures. Indeed, the difference in energy between the ground states of the para (J = 0) and ortho (J = 1) spin isomers has been reported to range between 169.7 K and 175.2 K [5,7,8], depending on the determination of the rotational constant.
The relative abundance of each spin isomer of H2 is dependent on the temperature of the gas and can be calculated using Boltzmann statistics [9]. When thermally equilibrated with room temperature (~295 K), the normal isomeric ratio of hydrogen gas (‘normal hydrogen’ or nH2) reflects the 1:3 distribution of the four total spin states for the two isomers: 25% pH2 vs. 75% oH2. Simply lowering the temperature of the gas increases the relative abundance of pH2; common pH2 fractions that are used for magnetic resonance applications range from ~50% pH2 at 77 K [10,11,12] to ~100% pH2 at 20 K [13,14,15], along with varying isomeric fractions at temperatures in between [16,17]. Because the interconversion between triplet and singlet states is quantum mechanically forbidden, converting between spin states proceeds slowly and is typically accelerated by exposing the gas to a paramagnetic catalysts (e.g., HFeO2) at the low temperature [18]. Parahydrogen generators can be lab constructed [12] or commercially procured and provide a constant flow of pH2-enriched gas to be used immediately for enhanced magnetic resonance (MR) experiments or stored for future use [19,20].
Although parahydrogen gas does not provide any magnetic resonance signal itself (each anti-aligned spin-½ hydrogen nuclei cancels the other, leaving the net nuclear spin as I = 0 for the diatom), it possesses near-unity spin order that can be transferred to nuclei in other chemical species, thus enhancing their MR signals by several orders of magnitude. The two common pathways for achieving this are termed parahydrogen induced polarization (PHIP)—a hydrogenative process that results in a new chemical species [21]—and signal amplification by reversible exchange (SABRE)—a non-hydrogenative pathway that does not chemically modify the substrate [22,23]. Importantly, PHIP and SABRE allow the high nuclear spin order of pH2 to be transferred to nuclei with low gyromagnetic ratios or isotopic abundances (e.g., 13C, 15N, etc.) in other molecules of interest [24,25,26,27] to allow their facile detection, including in dilute concentrations and at low magnetic fields. Using these methods, the MR signals for a range of biologically relevant small molecules have been enhanced, including in in vitro [28] and in vivo [29] scenarios. Furthermore, parahydrogen-based techniques benefit from low cost, ease-of-use, and fast cycle times compared with other MR signal enhancement approaches, such as spin-exchange optical pumping [30] and dynamic nuclear polarization [31].
After the pH2-enriched gas is generated, it retains its para spin abundance even after warming to room temperature. Over time, the gas slowly reverts to its normal isomeric fraction of 25% pH2 [32]. The rate of this reconversion (Tρ) is variable and can range from minutes (in the presence of isotropic paramagnetic impurities, such as gaseous O2) to hours (e.g., inside glass containers) to even weeks (e.g., in pressurized aluminum cylinders [33]). This long reconversion time is attributed to the forbidden singlet → triplet transition, and the absence of any paramagnetic species mitigates the speed of the conversion [34]. The reported use of pH2 to enhance nuclear magnetic resonance (NMR) signals has increased significantly since the introduction of SABRE in 2009 [22]. NMR studies typically use borosilicate glass tubes to complete liquid and gas-phase experiments. Borosilicate glass often contains a heterogeneous distribution of paramagnetic impurities in the form of Fe2+, Fe3+, Co, and Cr, etc. [35,36]. NMR sample tubes constructed of quartz or sapphire are also available and contain fewer impurities, albeit at a higher price that may not be conducive to widespread adoption. Indeed, the presence of paramagnetic impurities in glass also affects other hyperpolarized MR techniques, such as spin-exchange optical pumping of 3He [37] or 129Xe [38]. Although pH2 may not directly contact these paramagnetic centers in borosilicate glass, their proximity to the glass surface is sufficient to catalyze the reversion of pH2 to nH2 (via dipolar effects) at a higher rate than when stored in containers of differing surface composition (e.g., aluminum). Typical Tρ values for pH2 in glass NMR tubes have been measured at ~850 min [14,33]; however, larger and smaller Tρ values have also been reported [11,39,40] under different experimental conditions. Not only does pH2 revert faster in glass NMR tubes (compared with aluminum bottles) but the variability of this reconversion depends on the individual tube; for example, Parrot et al. reported a ~5-fold difference in Tρ for two off-the shelf NMR tubes from the same manufacturer [40]. The reversion of pH2 to nH2 is further confounded by the potential presence of O2 gas [41] within the NMR tube due to incomplete evacuation or a leaking valve [39].
Although the recent interest in pH2 has focused on its ability to enhance the NMR signals of other molecules of interest [42], the different rotational levels occupied by the para and ortho spin isomers provide a convenient method of observing the pH2 enrichment level using Raman spectroscopy (H2 rotational constant is reported to be between 84.8 K and 87.6 K [7]). The integrals of the first-order transitions of the lower-energy pH2 Raman peak (e.g., 355 cm−1) and higher-energy oH2 peak (e.g., 586 cm−1) can be compared in real time to determine the relative abundances of the two spin isomers. This internal comparison mitigates the need for a reference standard to determine the enrichment of pH2 in the gas sample, and Raman spectroscopy is significantly faster than NMR detection of the gas (remembering that the pH2 fraction does not provide an MR signal and must be deduced from changes to the oH2 MR signal over time) [19]. Furthermore, Raman spectroscopy can probe the gas in situ while stored within a glass NMR tube, with minimal interference from the glass container. Raman spectroscopy has been used previously to interrogate parahydrogen systems [43] across a range of analysis conditions, including the use of Raman microscopes [34,44], specialized gas cells with relatively high pressures (e.g., 345 bar) [45,46], or long integration times (e.g., 20 min per scan) [47]. Parrott et al. recently reported in situ measurements of pH2 enrichments from a parahydrogen generator using an in-line flow tube and non-contact backscattered Raman collection at lower pressures (e.g., 4 bar) and short integration times (e.g., 30 s) [40]; their study focused on characterizing and optimizing the production of a newly constructed pH2 generator for MR applications.
In this work, Raman spectroscopy was used to probe the reconversion of pH2 to nH2 in parahydrogen-enriched gas samples that were stored in a valved glass NMR tube. Nine different common surfactants were used to coat the inside surface of the tube to serve as a barrier to physically distance the pH2-enriched gas from the paramagnetic impurities within the glass (Figure 1). These surfactants varied in chemical composition, molecular length, and branching structure. Rotational Raman spectroscopy was performed on the gas samples directly through the NMR tubes, and changes to the ratio of the 586 cm−1 (oH2) vs. 355 cm−1 (pH2) peaks were plotted over time to measure the para-to-ortho conversion rate for H2 gas while in the presence of each surfactant. It was found that the addition of surfactants extended the pH2 reconversion time by a factor of 1.5–2× compared with untreated NMR tubes. This research is of particular importance to scientists who wish to maximize the lifetime of pH2 gas for storage in glass containers (including NMR applications).

2. Experimental

2.1. Parahydrogen Generator

This study utilized a laboratory-constructed pH2 generator that consistently produced parahydrogen enrichments of ~50%; Figure 2 provides a general overview of the device. The generator used high-purity H2 gas (99.999%) that was pressure-regulated at ~3.45 bar; this gas was directed to a conversion coil that was submerged in liquid nitrogen. The conversion coil was a ¼″ outer diameter copper tube (3 m length) that was bent into a multicoil. Inside of the bottom loops of the conversion coil, ~34 g of HFeO2 catalyst (Aldrich, St. Louis, MO, USA; 371254-250G; 30–50 mesh) was placed in the flow path of the H2 gas. The catalyst, which facilitated the conversion from oH2 to pH2, was retained in the coil using cotton wads. A calibrated flow controller (Sierra Instruments, Monterey, CA, USA) maintained the H2 flow rate at 30 standard cubic centimeters per minute (sccm) during experiments, and ¼″ PTFE tubing was used to move the gas between the H2 cylinder, conversion coil, flow controller, and manifold. When beginning an experiment, H2 gas was purged through the conversion coil (60 sccm) at room temperature for 30 min to remove residual atmosphere from the coil. Afterwards, the coil was submerged into the 10 L liquid nitrogen Dewar (MVE Lab10) and the H2 flow rate was decreased to 30 sccm. Gas sample collection would begin one hour after submersion of the conversion coil into the liquid nitrogen Dewar. Parahydrogen-enriched gas samples were collected in pre-evacuated (13.3 Pa) valved NMR tubes (Wilmad Labglass, Vineland, NJ, USA; 524-QPV-7), with a total of ~3.04 bar of gas loaded into each tube (~2.07 bar above atmosphere). Any uncollected H2 gas was exhausted to the laboratory fume hood.

2.2. Surfactants

Nine different commercially sourced surfactants were used to coat the inside surface of a valved NMR tube for the Raman studies in this work. These surfactants were mostly silane based, along with those possessing siloxane, laurate, and proprietary formulas. The surfactants were generically categorized by the size and shape of their chemical linkages: short (<5 links), medium (~10 links), long (~20+ links), or branched. Table 1 highlights the chemical information for the surfactants. Starting with a clean and dry NMR tube, a solution of 20% surfactant (by volume) in heptane was added to the tube and allowed to rest for 20 min. The solution was then decanted and the tube was rinsed in heptane (3×) and allowed to dry at room temperature overnight. Two of the surfactants received modifications to this protocol: Sigmacote (a proprietary solution of chlorinated organopolysiloxane in heptane; Sigma Aldrich, Burlington, MA, USA) was used as received without further dilution. Tween-80 (polyoxyethylene sorbitan monolaureate; MP Biomedicals, Santa Ana, CA, USA) was diluted and rinsed in ethanol (20% v/v) instead of heptane. Prior to loading the pH2, the tube was evacuated to ~13.3 Pa and attached to the gas loading manifold (Figure 2). Following gas loading and Raman spectroscopy, the tube was stripped of surfactant by filling with a base solution (supersaturated solution of NaOH in methanol) overnight. Afterwards, the base solution was decanted, the NMR tube was rinsed with methanol (3×), filled with methanol, and suspended in a heated ultrasonic bath for 40 min at 50 °C, followed by a methanol rinse. The tube received a final rinse with heptane and was allowed to dry overnight (at room temperature) before repeating the procedure to add a new surfactant. A single NMR tube was used to control for variability in paramagnetic impurities in the glassware, integrity of the valve, and background Raman signal. The order of surfactant choice was random, and no hysteresis was noticed in the Tρ data. A water bead test established adequate removal of old surfactant between experiments; this was also confirmed in select cases using Raman measurements (Supplemental Materials Figure S5).

2.3. Raman Spectroscopy

All Raman spectra were collected using a volume Bragg grating stabilized 785 nm diode laser (Innovative Photonic Solutions, Plainsboro, NJ, USA), which was internally coupled to a multi-mode fiber-optic with FC/PC termination. The laser was joined to the excitation leg of a bifurcated fiber-optic Raman probe (Innovative Photonic Solutions) and aligned to the center of the NMR tube using a homebuilt XYZ micro-positioning stage. The probe delivered ~290 mW of laser power to the sample in a ~100 μm diameter spot directed to the midsection of the NMR tube. The collection leg of the probe was coupled to a high-throughput transmission (f/1.6) spectrograph (Ibsen Photonics, Farum, Denmark). Raman signals were collected using a deep depleted back-illuminated CCD camera (Andor Instruments, Belfast, UK) that was thermoelectrically cooled to −60 °C. A schematic of the Raman collection setup is found in Figure 3. Integration times of 30 s were used for data collection, and spectra were collected continuously during the course of the experiment (e.g., 50 h). The spectral data were analyzed using in-house MATLAB code, which included an open-source adaptive iteratively reweighted penalized least squares (airPLS) algorithm for baseline correction.

3. Results and Discussion

3.1. Measuring Tρ

Immediately after loading pH2-enriched gas (~3.04 bar) into the evacuated NMR tube, Raman spectra were collected continuously (30 s integration time per acquisition) over the course of several hours. Figure 4 provides an example of spectra obtained on the J: 0 → 2 transition at 355 cm−1 for the para spin isomer and J: 1 → 3 transition at 586 cm−1 for the ortho spin isomer, both immediately following pH2-enriched gas loading and after 65 h had elapsed. At the beginning of the experiment, the para and ortho spin isomers are nearly equal in population (e.g., ~50% pH2), leading to similarly sized Raman peaks. At the end of the experiment, the characteristic 3:1 ratio of ortho-to-para spins is evident by the relative integrals of the Raman peaks at thermal equilibrium. Spectra were also observed for the higher energy J: 2 → 4 (para; 812 cm−1) and J: 3 → 5 (ortho; 1032 cm−1) transitions (Supplemental Figure S1). These higher-energy peaks were significantly weaker than the peaks at 355 cm−1 and 586 cm−1, and no other peaks were observed at transitions above 1032 cm−1 (e.g., vibrational levels).
In order to determine the para-to-ortho reconversion rate, the ratios of the 586 cm−1 vs. 355 cm−1 peak integrals were plotted over an extended timeline (Figure 5). At the start time, the ratio of the peaks was approximately 1-to-1, indicating a pH2 enrichment of ~50%. Over time, as pH2 converted to oH2, the ratio grew to approximately [40] 3-to-1; this is expected at thermal equilibrium and reflects the anticipated 75/25 fraction of ortho-para H2 at room temperature. This plot was repeated for all NMR tube surface conditions (Supplemental Figure S3), and the data was fitted to a monoexponential function to allow determination of Tρ. Given the significantly reduced intensity of the higher-order transitions (e.g., 812 cm−1 and 1032 cm−1) compared with the first-order peaks as well as the similarity of their observed populations, the J: 2 → 4 and J: 3 → 5 peaks were not factored into the ortho vs. para ratios described in this paper.

3.2. Comparing Tρ across Surfactants

The Tρ values calculated for each surface chemistry are compared in Figure 6. The control case was a bare, untreated NMR tube; this tube exhibited a Tρ value of 280.2 min. The addition of surfactants resulted in variable increases to the Tρ values; this ranged from a 31% increase for Sigmacote to a 123% increase for GOTTS. Despite testing surfactants of varying length and branching, there was no overarching dependence of Tρ on the classification of surfactant. In general, the ‘medium length’ surfactants (~10 carbon atoms) exhibited the longest Tρ values, with 625.0 min for GOTTS and 608.1 min for MAPTMS. However, the next several surfactants that provided the longest pH2 Tρ values were of varying classification: Tween-20 (long, non-silane; 593.5 min), DOTTS (medium, branched; 559.4 min), and LTS (long; 548.4 min). The four surfactants with the least effect on Tρ were DCS (short; 489.6 min), OTS (long; 450.8 min), APTES (short; 429.4 min), and Sigmacote (proprietary; 367.3 min). Although these four surfactant choices were deemed as the least effective for maximizing Tρ, it should be noted that they still increased the pH2 lifetime by 31–75% compared with the uncoated NMR tube.

3.3. Utilizing Surfactants for Hyperpolarized Media

The presence of paramagnetic impurities within glass has been a nuisance to various sectors of the hyperpolarized MR community over the last several decades. Spin-exchange optical pumping cells for enhancing the MR signals of noble gases (e.g., 129Xe) are often coated in a silanizing agent prior to loading with alkali metals in order to extend the polarized lifetime of the gases [48]. Indeed, 3He hyperpolarization for MRI applications and as neutron spin filters often utilizes a special alumina silicate glass (GE180) to minimize 3He permeability and spin relaxation during optical pumping and gas storage [49]. The ability to significantly extend the lifetime of pH2 gas when stored in glass vessels is of particular interest to the hyperpolarized MR community. The use of glass surfactants in valved NMR tubes can be particularly beneficial to pH2 experiments utilizing the “shake” method of introducing the gas to a liquid sample within the tube [22,42]. In this instance, pH2-enriched gas (e.g., 1–9 bar) is loaded into an evacuated valved NMR tube that already contains the degassed sample that is to be hyperpolarized. The sample tube is then physically agitated to introduce the pH2-enriched gas into the sample solution to participate in PHIP reactions or SABRE interactions, which results in enhanced MR signals of the substrate molecules. This method can be employed multiple times with a single pH2 gas loading, and the use of surfactants may extend the lifetime of the pH2 in the gas phase above the liquid sample (albeit with unknown potential contributions from vaporized solvents). Furthermore, recent work on hyperpolarizing gas-phase molecules (e.g., propane) [50] using parahydrogen may also benefit from the use of surfactants, with the added possibility of prolonging the hyperpolarized lifetime of the gas-phase substrate molecule (via minimizing wall-induced relaxation) in addition to the pH2 isomer. An additional potential benefit of incorporating surfactants is the ability for researchers to produce single aliquots of long-lasting pH2 pre-loaded into valved NMR tubes (also containing the hyperpolarizable sample) for NMR experiments at a different location (e.g., collaborator’s lab). This is in contrast to the common practice of researchers providing a pressurized aluminum cylinder of pH2-enriched gas that the collaborators must then introduce to the sample themselves (requiring additional skills and equipment).

3.4. Raman Measurements of Hydrogen Spin Isomers

Despite the regularity of using NMR measurements to quantify the pH2 fraction in valved NMR tubes, there are several distinct advantages of applying Raman spectroscopy instead. Because pH2 does not provide any NMR signal, a sample tube containing a mixture of pH2 and oH2 only provides a single 1H NMR peak (ascribed to the oH2). The signal acquisition then needs to be repeated over time to monitor the increasing intensity of that single peak (as pH2 converts to oH2) until the signal reaches equilibrium. Only after the sample has reverted to its normal isomeric ratio can the fraction of pH2 be indirectly measured from the corresponding increase in NMR signal intensity and knowledge of the Boltzmann distribution of spin states. Because the complete equilibration of spins may take days to conclude (e.g., 5 × Tρ), NMR is an inherently time-consuming approach to measure pH2 fractions in the gas phase. Conversely, Raman measurements can be advantageous because pH2 and oH2 each provide distinct rotational peaks, allowing the relative fractions of the two spin isomers can be determined within seconds from a single Raman spectrum. This functionality can also provide in-line quality assurance for pH2 generators [40]. Although the surfactant molecules used in this study are known to absorb mid-IR and far-IR light [51], this project did not observe absorption at the 785 nm laser line or nearby first-order Raman shifts.

3.5. Comparison with Previous Tρ Measurements

Although this study has shown how glass surfactants can extend the Tρ values of gas-phase parahydrogen, the actual values are less than other reported cases for parahydrogen reconversion in bare NMR tubes. For example, Feng et al. [33] used NMR to measure Tρ in an uncoated low-pressure borosilicate NMR tube as ~850 min, which is ~3× longer than the Tρ value measured in our control study. The most likely cause for this discrepancy is differences in the initial evacuation of the NMR tubes prior to gas loading. Whereas Feng et al. were able to evacuate their NMR tubes to less than 1.3 Pa, our system only allowed evacuation to ~13.3 Pa. This 10-fold difference in vacuum level allowed more gaseous oxygen to remain in our sample tubes with the parahydrogen; O2 has been previously shown [41] to hasten the reconversion of pH2 to nH2. Although the absolute numbers of Tρ are lower in our study, the trend of improving Tρ with the use of surfactant should provide even longer reconversion times in NMR tubes that are more extensively evacuated prior to gas loading. Indeed, if the same relative extension of pH2 lifetime is experienced in better-evacuated NMR tubes (such as [33]), then Tρ values exceeding 30 h should be accessible in glass vessels. Additional future studies may monitor pH2 Tρ in non-borosilicate NMR tubes, such as those constructed from quartz, zirconia, or sapphire, as well as monitor the effects of surfactant molecule polarity on the pH2 reconversion rate.

4. Conclusions

Extending the lifetime of pH2 in the gas phase is of particular importance to the hyperpolarized magnetic resonance community, as it expands the available timeline for enhancing the MR signals of various molecules of interest. This work demonstrates that the addition of silane-, siloxane-, and laureate-based surfactants to the inner glass surface of borosilicate NMR tubes increased the reconversion time of gaseous parahydrogen by factors ranging from 1.5–2× compared with an uncoated tube. This approach may be of particular interest for systems where pH2 gas is in contact with glass surfaces, such as for the “shake” method of PHIP and SABRE and hyperpolarizing gas-phase molecules using pH2. Furthermore, Raman spectroscopy provided a fast and simple in situ method to monitor the conversion of pH2-enriched gas to its normal isomeric abundance.

Supplementary Materials

Supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/molecules28052329/s1. Figure S1: Example extended Raman spectra of nH2 gas showing the first four rotational transitions: lower- energy J: 0 → 2 (para; 355 cm−1) and J: 1 → 3 (ortho; 586 cm−1) peaks, as well as higher-energy peaks at the J: 2 → 4 (para; 812 cm−1) and J: 3 → 5 (ortho; 1032 cm−1) transitions. Spectra collected using NMR tube coated with OTS surfactant at the time point of t = 3988 min after filling with pH2-enriched gas; Figure S2: Example Raman spectra of the J: 0 → 2 ‘para’ spin peak (355 cm−1) and J: 1 → 3 ‘ortho’ spin peak (586 cm−1), taken both immediately after loading the pH2- enriched gas into the valved NMR tube (blue solid line) and after 65 h had elapsed (red dashed line). This figure plots the same spectra that is available in Figure 4, and demonstrates consistent Raman shifts and linewidths for the peaks; Figure S3: Example Tρ curves for the different experimental conditions. Ratio of the 586 cm−1 vs. 355 cm−1 peak integrals for each glass surface condition: (a) Control, (b) DCS, (c) GOTTS, (d) MAPTMS, (e) OTS, (f) LTS, (g) DOTTS, (h) APTES, (i) Sigmacote, and (j) Tween. Chemical information for each surfactant is available in Table 1 of the main document and Supplemental Table S1. Each dataset is fit to a single exponential decay function (red line) to extract the value of Tρ, along with the listed fit error. Please note the different x-axis scale for part (a); Figure S4: pH2 reconversion rate (Tρ) data from Figure 6 plotted with the surfactant types grouped. The x-axis denotes the surfactant type: control (C), short (S), medium (M), long (L), and branched (B); Figure S5: Comparison of the I586 cm−1 / I355 cm−1 time course measurements under three conditions: an NMR tube with no surfactant (Control 1; Tρ: 280 min; blue) followed by the same NMR tube coated with DOTTS surfactant (DOTTS; Tρ: 586 min; purple). The tube was then stripped of surfactant (following the protocol in Section 2.2 of the manuscript), and another time course measurement was completed (Control 2; Tρ: 271 min; red). This demonstrates that adequate surfactant removal between experiments was achieved; Table S1: Chemical and vendor information for surfactants used in this study, along with Tρ tabulation (error indicative of equation fitting).

Author Contributions

Conceptualization, R.V.C. and N.W.; methodology, R.V.C. and N.W.; software, R.V.C. and N.W.; validation, R.V.C., J.D., J.S., J.N. and N.W.; formal analysis, R.V.C. and N.W.; investigation, R.V.C., J.D., J.S., J.N. and N.W.; resources, R.V.C. and N.W.; data curation, R.V.C., J.D., J.S. and N.W.; writing—original draft preparation, R.V.C. and N.W.; writing—review and editing, R.V.C., J.D., J.S., J.N. and N.W.; visualization, R.V.C. and N.W.; supervision, N.W.; project administration, N.W.; funding acquisition, N.W. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the American Chemical Society Petroleum Research Fund, grant number 65275-UNI6; the Eppley Foundation for Research, grant number 1023; and Rowan University Seed Funds. The APC was funded by Rowan University Libraries.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data is available upon request to the corresponding author.

Acknowledgments

We would like to thank L. Viola and D. Caruso (Rowan) for helpful conversations regarding this project.

Conflicts of Interest

The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

References

  1. Farkas, A. Orthohydrogen, Parahydrogen and Heavy Hydrogen; Cambridge University Press: London, UK, 1935. [Google Scholar]
  2. Pravdivtsev, A.; Barskiy, D.A.; Hovener, J.-B.; Koptyug, I.V. Symmetry Constraints on Spin Order Transfer in Parahydrogen-Induced Polarization (PHIP). Symmetry 2022, 14, 530. [Google Scholar] [CrossRef]
  3. Leachman, J.; Jacobsen, R.; Penoncello, S.; Lemmon, E. Fundamental Equations of State for Parahydrogen, Normal Hydrogen, and Orthohydrogen. J. Phys. Chem. 2009, 38, 721–748. [Google Scholar] [CrossRef]
  4. Buljubasich, L.; Franzoni, M.; Munnemann, K. paraHydrogen Induced Polarization by Homogenous Catalysis: Theory and Applications. Top Curr. Chem. 2013, 338, 33–74. [Google Scholar]
  5. Green, R.; Adams, R.W.; Duckett, S.B.; Mewis, R.E.; Williamson, D.C.; Green, G.G. The Theory and Practice of Hyperpolarization in Magnetic Resonance using Parahydrogen. Prog. Nucl. Magn. Reson. Spectrosc. 2012, 67, 1–48. [Google Scholar] [CrossRef]
  6. Buntkowsky, G.; Theiss, F.; Lins, J.; Miloslavina, Y.; Wienands, L.; Kiryutin, A.; Yurkovskaya, A. Recent Advances in the Application of Parahydrogen in Catalysis and Biochemistry. Rsc Adv. 2022, 12, 12477–12506. [Google Scholar] [CrossRef]
  7. Goldman, M.; Johannesson, H.; Axelsson, O.; Karlsson, M. Design and Implementation of 13C Hyperpolarization from Para-Hydrogen, for New MRI Contrast Agents. Comptes Rendus Chim. 2006, 9, 357–363. [Google Scholar] [CrossRef]
  8. Barskiy, D.A.; Knecht, S.; Yurkovskaya, A.; Ivanov, A.V. SABRE: Chemical Kinetics and Spin Dynamics of the Formation of Hyperpolarization. Prog. Nucl. Magn. Reson. Spectrosc. 2018, 114, 33–70. [Google Scholar] [CrossRef]
  9. Essler, J.; Haberstroh, C. Performance of an Ortho-Para Concentration Measurement Cryostat for Hydrogen. In AIP Conference Proceedings; American Institute of Physics: College Park, MD, USA, 2012; pp. 1865–1872. [Google Scholar]
  10. Ellermann, F.; Pravdivtsev, A.; Hovener, J.-B. Open-Source, Partially 3D-Printed, High-Pressure (50-bar) Liquid-Nitrogen-Cooled Parahydrogen Generator. Magn. Reson. 2020, 2, 49–62. [Google Scholar] [CrossRef]
  11. Gamliel, A.; Allouche-Arnon, H.; Nalbandian, R.; Barzilay, C.; Gomori, J.; Katz-Brull, R. An Apparatus for Production of Isotopically and Spin-Enriched Hydrogen for Induced Polarization Studies. Appl. Magn. Reson. 2010, 39, 329–345. [Google Scholar] [CrossRef]
  12. Chapman, B.; Joalland, B.; Meersman, C.; Ettedgui, J.; Swenson, R.; Krishna, M.; Nikolaou, P.; Kovtunov, K.V.; Salnikov, O.G.; Koptyug, I.V.; et al. Low-Cost High-Pressure Clinical-Scale 50% Parahydrogen Generator Using Liquid Nitrogen at 77 K. Anal. Chem. 2021, 93, 8476–8483. [Google Scholar] [CrossRef]
  13. Hovener, J.-B.; Chekmenev, E.Y.; Harris, K.; Perman, W.; Robertson, L.; Ross, B.D.; Bhattacharya, P.K. PASADENA Hyperpolarization of 13C Biomolecules: Equipment Design and Installation. Magn. Reson. Mater. Phys. Biol. Med. 2009, 22, 111–121. [Google Scholar] [CrossRef] [Green Version]
  14. Hovener, J.-B.; Bar, S.; Leupold, J.; Jenne, K.; Leibfritz, D.; Hennig, J.; Duckett, S.B.; von Elverfeldt, D. A Continuous-Flow, High-Throughput, High-Pressure Parahydrogen Converter for Hyperpolarization in a Clinical Setting. Nmr Biomed. 2013, 26, 124–131. [Google Scholar] [CrossRef]
  15. Nantogma, S.; Joalland, B.; Wilkens, K.; Chekmenev, E.Y. Clinical-Scale Production of Nearly Pure (>98.5%) Parahydrogen and Quantification by Benchtop NMR Spectroscopy. Anal. Chem. 2021, 93, 3594–3601. [Google Scholar] [CrossRef]
  16. Mhaske, Y.; Sutter, E.; Daley, J.; Mahoney, C.; Whiting, N. 65% Parahydrogen from a Liquid Nitrogen Cooled Generator. J. Magn. Reson. 2022, 341, 107249. [Google Scholar] [CrossRef]
  17. Birchall, J.; Coffey, A.M.; Goodson, B.M.; Chekmenev, E.Y. High-Pressure Clinical-Scale 87% Parahydrogen Generator. Anal. Chem. 2020, 92, 15280–15284. [Google Scholar] [CrossRef]
  18. Ilisca, E. Ortho-Para Conversion of Hydrogen Molecules Physisorbed on Surfaces. Prog. Surf. Sci. 1992, 41, 217–335. [Google Scholar] [CrossRef]
  19. Schmidt, A.; Bowers, C.R.; Buckenmaier, K.; Chekmenev, E.Y.; de Maissin, H.; Eills, J.; Ellermann, F.; Gloggler, S.; Gordon, J.; Knecht, S.; et al. Instrumentation for Hydrogenative Parahydrogen-Based Hyperpolarization Techniques. Anal. Chem. 2022, 94, 479–502. [Google Scholar] [CrossRef]
  20. Coffey, A.M.; Shchepin, R.; Truong, M.L.; Wilkens, K.; Pham, W.; Chekmenev, E.Y. Open-Source Automated Parahydrogen Hyperpolarizer for Molecular Imaging Using 13C Metabolic Contrast Agents. Anal. Chem. 2016, 88, 8279–8288. [Google Scholar] [CrossRef]
  21. Bowers, C.R.; Weitekamp, D.P. Parahydrogen and Synthesis Allow Dramatically Enhanced Nuclear Alignment. J. Am. Chem. Soc. 1987, 109, 5541–5542. [Google Scholar] [CrossRef] [Green Version]
  22. Adams, R.W.; Aguilar, J.A.; Atkinson, K.D.; Cowley, M.J.; Elliott, P.I.P.; Duckett, S.B.; Green, G.G.; Khazal, I.G.; Lopez-Serrano, J.; Williamson, D.C. Reversible Interactions with para-Hydrogen Enhance NMR Sensitivity by Polarization Transfer. Science 2009, 323, 1708–1711. [Google Scholar] [CrossRef] [Green Version]
  23. Cowley, M.J.; Adams, R.W.; Atkinson, K.D.; Cockett, M.C.R.; Duckett, S.B.; Green, G.G.; Lohman, J.A.B.; Kerssebaum, R.; Kilgour, D.; Mewis, R.E. Iridium N-Heterocyclic Carbene Complexes as Efficient Catalysts for Magnetization Transfer from Para-Hydrogen. J. Am. Chem. Soc. 2011, 133, 6134–6137. [Google Scholar] [CrossRef] [Green Version]
  24. Duckett, S.B.; Newell, C.L.; Eisenberg, R. More than INEPT: Parahydrogen and INEPT+ Give Unprecedented Resonance Enhancement to Carbon-13 by Direct Proton Polarization Transfer. J. Am. Chem. Soc. 1993, 115, 1156–1157. [Google Scholar] [CrossRef]
  25. Truong, M.L.; Theis, T.; Coffey, A.M.; Shchepin, R.; Waddell, K.W.; Shi, F.; Goodson, B.M.; Warren, W.S.; Chekmenev, E.Y. 15N Hyperpolarization by Reversible Exchange Using SABRE-SHEATH. J. Phys. Chem. C 2015, 119, 8786–8797. [Google Scholar] [CrossRef] [Green Version]
  26. Kuhn, L.; Bommerich, U.; Bargon, J. Transfer of Parahydrogen-Induced Hyperpolarization to 19F. J. Phys. Chem. A 2006, 110, 3521–3526. [Google Scholar] [CrossRef]
  27. Ellena, S.; Viale, A.; Gobetto, R.; Aime, S. Para-Hydrogen Induced Polarization of Si-29 NMR Resonances as a Potentially Useful Tool for Anayltical Applications. Magn. Reson. Chem. 2012, 50, 529–533. [Google Scholar] [CrossRef]
  28. Cavallari, E.; Carrera, C.; Aime, S.; Reineri, F. 13C MR Hyperpolarization of Lactate by Using ParaHydrogen and Metabolic Transformation In Vitro. Chem. A Eur. J. 2017, 23, 1200–1204. [Google Scholar] [CrossRef] [Green Version]
  29. Golman, K.; Axelsson, O.; Johannesson, H.; Mansson, S.; Olofsson, C.; Petersson, J.S. Parahydrogen-Induced Polarization in Imaging: Subsecond 13C Angiography. Magn. Reson. Med. 2001, 46, 1–5. [Google Scholar] [CrossRef]
  30. Goodson, B.M. Nuclear Magnetic Resonance of Laser-Polarized Noble Gases in Molecules, Materials, and Organisms. J. Magn. Reson. 2002, 155, 157–216. [Google Scholar] [CrossRef] [Green Version]
  31. Golman, K.; Zandt, R.; Thaning, M. Real-Time Metabolic Imaging. Proc. Natl. Acad. Sci. USA 2006, 103, 11270–11275. [Google Scholar] [CrossRef] [Green Version]
  32. Buntkowsky, G.; Walaszek, B.; Adamczyk, A.; Xu, Y.; Limbach, H.-H.; Chaudret, B. Mechanism of Nuclear Spin Initiated Para-H2 to Ortho-H2 Conversion. Phys. Chem. Chem. Phys. 2006, 8, 1929–1935. [Google Scholar] [CrossRef]
  33. Feng, B.; Coffey, A.M.; Colon, R.; Chekmenev, E.Y.; Waddell, K.W. A Pulsed Injection Parahydrogen Generator and Techniques for Quantifying Enrichment. J. Magn. Reson. 2012, 214, 258–262. [Google Scholar] [CrossRef] [Green Version]
  34. Teshigawara, M.; Harada, M.; Tatsumoto, H.; Aso, T.; Ohtsu, K.; Takada, H.; Futakawa, M.; Ikeda, Y. Experimental Verification of Equilibrium Para-Hydrogen Levels in Hydrogen Moderators Irradiated by Spallation Neutron at J-PARC. Nucl. Instrum. Methods Phys. Res. B 2016, 368, 66–70. [Google Scholar] [CrossRef]
  35. Bonfanti, S.; Jug, G. On the Paramagnetic Impurity Concentration of Silicate Glasses from Low-Temperature Physics. J. Low Temp. Phys. 2015, 180, 214–237. [Google Scholar] [CrossRef] [Green Version]
  36. Miyoshi, H.; Chen, D.; Akai, T. Distribution of Paramagnetic Co and Cr Ions in Phase Separated Alkali Borosilicate Glass Observed by Leaching Behavior and 29Si NMR Relaxation. Phys. Chem. Glasses 2005, 46, 157–160. [Google Scholar]
  37. Fitzsimmons, W.; Tankersley, L.; Walters, G. Nature of Surface-Induced Nuclear Spin Relaxation of Gaseous He3. Phys. Rev. 1969, 179, 156–165. [Google Scholar] [CrossRef]
  38. Driehuys, B.; Cates, G.; Happer, W. Surface Relaxation Mechanisms of Laser-Polarized 129Xe. Phys. Rev. Lett. 1995, 74, 4943–4946. [Google Scholar] [CrossRef]
  39. Tom, B.; Bhasker, S.; Miyamoto, Y.; Momose, T.; McCall, B. Producing and Quantifying Enriched Para-H2. Rev. Sci. Instrum. 2009, 80, 016108. [Google Scholar] [CrossRef] [Green Version]
  40. Parrott, A.; Dallin, P.; Andrews, J.; Richardson, P.M.; Semenova, O.; Halse, M.; Duckett, S.B.; Nordon, A. Quantitative In Situ Monitoring of Parahydrogen Fraction Using Raman Spectroscopy. Appl. Spectrosc. 2019, 73, 88–97. [Google Scholar] [CrossRef] [Green Version]
  41. Wagner, S. Conversion Rate of Para-Hydrogen to Ortho-Hydrogen by Oxygen: Implications for PHIP Gas Storage and Utilization. Magn. Reson. Mater. Phys. Biol. Med. 2014, 27, 195–199. [Google Scholar] [CrossRef]
  42. Hovener, J.-B.; Pravdivtsev, A.; Kidd, B.; Bowers, C.R.; Gloggler, S.; Kovtunov, K.V.; Plaumann, M.; Katz-Brull, R.; Buckenmaier, K.; Jerschow, A.; et al. Parahydrogen-Based Hyperpolarization for Biomedicine. Agnewandte Chem. 2018, 57, 11140–11162. [Google Scholar] [CrossRef]
  43. Fleury, P.; McTague, J. Molecular Interactions in the Condensed Phases of Ortho-Para Hydrogen Mixtures. Phys. Rev. A 1975, 12, 317–326. [Google Scholar] [CrossRef]
  44. Sundararajan, K.; Sankaran, K.; Ramanathan, N.; Gopi, R. Production and Characterization of Para-Hydrogen Gas for Matrix Isolation Infrared Spectroscopy. J. Mol. Struct. 2016, 1117, 181–191. [Google Scholar] [CrossRef]
  45. Petitpas, G.; Aceves, S.; Matthews, M.; Smith, J. Para-H2 to Ortho-H2 Conversion in a Full-Scale Automotive Cryogenic Pressurized Hydrogen Storage up to 345 Bar. Int. J. Hydrog. Energy 2014, 39, 6533–6547. [Google Scholar] [CrossRef]
  46. Matthews, M.; Petitpas, G.; Aceves, S. A Study of Spin Isomer Conversion Kinetics in Supercritical Fluid Hydrogen for Cryogenic Fuel Storage Technologies. Appl. Phys. Lett. 2011, 99, 081906. [Google Scholar] [CrossRef]
  47. Sutherland, L.-M.; Knudson, J.; Mocko, M.; Renneke, R. Practical In Situ Determination of Ortho-Para Hydrogen Ratios Via Fiber-Optic Based Raman Spectroscopy. Nucl. Instrum. Methods Phys. Res. A 2016, 810, 182–185. [Google Scholar] [CrossRef] [Green Version]
  48. Breeze, S.; Lang, S.; Moudrakovski, I.; Ratcliffe, C.; Ripmeester, J.; Sanytr, G.; Simard, B.; Zuger, I. Coatings for Optical Pumping Cells and Short-Term Storage of Hyperpolarized Xenon. J. Appl. Phys. 2000, 87, 8013–8017. [Google Scholar] [CrossRef]
  49. Salhi, Z.; Babcock, E.; Pistel, P.; Ioffe, A. 3He Neutron Spin Filter Cell Development Program at JCNS. J. Phys. Conf. Ser. 2014, 528, 012015. [Google Scholar] [CrossRef] [Green Version]
  50. Kovtunov, K.V.; Koptyug, I.V.; Fekete, M.; Duckett, S.B.; Theis, T.; Joalland, B.; Chekmenev, E.Y. Parahydrogen-Induced Hyperpolarization of Gases. Angew. Chem. 2020, 59, 17788–17797. [Google Scholar] [CrossRef]
  51. National Institute of Standards and Technology. NIST Chemistry WebBook, SRD 69; U.S. Department of Commerce: Washington, DC, USA, 2022. [Google Scholar]
Figure 1. Schematic of different surfactant coatings on the inside glass surface of a valved NMR tube. Red ‘x’ denotes paramagnetic impurity within glass surface. Blue dots represent pH2 molecules in the gas phase. Black chemical structures are different surfactants: (a) bare glass, (b) DCS, (c) GOTTS, (d) OTS, and (e) DOTTS. See Table 1 for full names and chemical formulas.
Figure 1. Schematic of different surfactant coatings on the inside glass surface of a valved NMR tube. Red ‘x’ denotes paramagnetic impurity within glass surface. Blue dots represent pH2 molecules in the gas phase. Black chemical structures are different surfactants: (a) bare glass, (b) DCS, (c) GOTTS, (d) OTS, and (e) DOTTS. See Table 1 for full names and chemical formulas.
Molecules 28 02329 g001
Figure 2. Parahydrogen generator schematic. H2 gas (1) is directed into the conversion coil (2) submerged in a 10 L liquid nitrogen Dewar (3). The flow is regulated by an in-line controller (4), and a sample-side pressure gauge (5) is used for loading. Valves (6–8) are used to either direct the pH2-enriched gas to a pre-evacuated, valved NMR tube (9) or exhaust the gas to the fume hood (10).
Figure 2. Parahydrogen generator schematic. H2 gas (1) is directed into the conversion coil (2) submerged in a 10 L liquid nitrogen Dewar (3). The flow is regulated by an in-line controller (4), and a sample-side pressure gauge (5) is used for loading. Valves (6–8) are used to either direct the pH2-enriched gas to a pre-evacuated, valved NMR tube (9) or exhaust the gas to the fume hood (10).
Molecules 28 02329 g002
Figure 3. Raman collection setup. Bifurcated fiber-optic-coupled Raman probe on XYZ translational stage is directed to the center volume of a valved NMR tube, allowing for the collection of rotational Raman spectroscopy of the isomerically evolving H2 gas.
Figure 3. Raman collection setup. Bifurcated fiber-optic-coupled Raman probe on XYZ translational stage is directed to the center volume of a valved NMR tube, allowing for the collection of rotational Raman spectroscopy of the isomerically evolving H2 gas.
Molecules 28 02329 g003
Figure 4. Example Raman spectra of the J: 0 → 2 ‘para’ spin peak (355 cm−1) and J: 1 → 3 ‘ortho’ spin peak (586 cm−1), taken both (a) immediately after loading the pH2-enriched gas into the valved NMR tube and (b) after 65 h had elapsed. The relative abundances of the two spin isomers can be determined from their relative peaks (e.g., the pH2 fraction is nearly 50% at t = 0 and reverts to the thermal equilibrium value of 25% within 65 h). See Supplemental Figure S2 for a version of this plot with the peaks overlaid, demonstrating consistent shift and linewidth between time points.
Figure 4. Example Raman spectra of the J: 0 → 2 ‘para’ spin peak (355 cm−1) and J: 1 → 3 ‘ortho’ spin peak (586 cm−1), taken both (a) immediately after loading the pH2-enriched gas into the valved NMR tube and (b) after 65 h had elapsed. The relative abundances of the two spin isomers can be determined from their relative peaks (e.g., the pH2 fraction is nearly 50% at t = 0 and reverts to the thermal equilibrium value of 25% within 65 h). See Supplemental Figure S2 for a version of this plot with the peaks overlaid, demonstrating consistent shift and linewidth between time points.
Molecules 28 02329 g004
Figure 5. Plot comparing the ratio of integrals for the 586 cm−1 peak (ortho) vs. the 355 cm−1 peak (para) over time in a valved NMR tube coated with APTES. The initial 1-to-1 ratio denotes a 50/50 mixture of para and ortho spins, which slowly equilibrates to a 1-to-3 ratio of para vs. ortho upon reconversion.
Figure 5. Plot comparing the ratio of integrals for the 586 cm−1 peak (ortho) vs. the 355 cm−1 peak (para) over time in a valved NMR tube coated with APTES. The initial 1-to-1 ratio denotes a 50/50 mixture of para and ortho spins, which slowly equilibrates to a 1-to-3 ratio of para vs. ortho upon reconversion.
Molecules 28 02329 g005
Figure 6. Plot comparing the pH2 Tρ values for a valved NMR tube coated with different surfactants. All surfactants provided longer Tρ values than the control (uncoated glass), with some doubling the control’s Tρ value. Vertical black dashed line marks the Tρ value of the control; vertical orange dashed line marks the longest Tρ value observed. Supplemental Figure S4 plots this data grouped by surfactant category (e.g., small, medium, long, branched).
Figure 6. Plot comparing the pH2 Tρ values for a valved NMR tube coated with different surfactants. All surfactants provided longer Tρ values than the control (uncoated glass), with some doubling the control’s Tρ value. Vertical black dashed line marks the Tρ value of the control; vertical orange dashed line marks the longest Tρ value observed. Supplemental Figure S4 plots this data grouped by surfactant category (e.g., small, medium, long, branched).
Molecules 28 02329 g006
Table 1. Chemical information regarding the surfactant molecules used in this study. Vendor information available in the Supplemental Materials Table S1.
Table 1. Chemical information regarding the surfactant molecules used in this study. Vendor information available in the Supplemental Materials Table S1.
AcronymChemical NameChemical FormulaClassification
Control------------------------Control
DCSDichloromethylsilaneCH3SiHCl2Short
GOTTS(3-Glycidoxypropyl)trimethoxysilaneC9H20O5SiMedium
MAPTMS3-(Methacryloyloxy)propyltrimethoxysilaneC10H20O5SiMedium
OTSn-OctadecyltrichlorosilaneC18H37Cl3SiLong
LTSLauryl triethoxysilaneC18H40O3SiLong
DOTTS1,7-Dichloro-octamethyltetrasiloxaneCl[Si(CH3)2O]3Si(CH3)2ClBranched
APTES(3-Aminopropyl)-triethoxysilaneH2N(CH2)3Si(OC2H5)3Branched
SigmacoteSigmacoteProprietaryCommercial
Tween-80Polyoxyethylene sorbitan monolaurateC64H124O26Long, non-silane
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Chimenti, R.V.; Daley, J.; Sack, J.; Necsutu, J.; Whiting, N. Reconversion of Parahydrogen Gas in Surfactant-Coated Glass NMR Tubes. Molecules 2023, 28, 2329. https://doi.org/10.3390/molecules28052329

AMA Style

Chimenti RV, Daley J, Sack J, Necsutu J, Whiting N. Reconversion of Parahydrogen Gas in Surfactant-Coated Glass NMR Tubes. Molecules. 2023; 28(5):2329. https://doi.org/10.3390/molecules28052329

Chicago/Turabian Style

Chimenti, Robert V., James Daley, James Sack, Jennifer Necsutu, and Nicholas Whiting. 2023. "Reconversion of Parahydrogen Gas in Surfactant-Coated Glass NMR Tubes" Molecules 28, no. 5: 2329. https://doi.org/10.3390/molecules28052329

Article Metrics

Back to TopTop