Recent Advances in Dental Implants and Oral Health

A special issue of Medicina (ISSN 1648-9144). This special issue belongs to the section "Dentistry".

Deadline for manuscript submissions: 20 August 2024 | Viewed by 6499

Special Issue Editor


E-Mail
Guest Editor
Department of Biotechnology, Universidad Católica de Murcia (UCAM), 30107 Murcia, Spain
Interests: bone substitutes; dental implants; implantable materials; biomechanical and histological analyses; biomaterials design and characterization; cellular behavior and interaction with biomaterials; in vitro and in vivo studies

Special Issue Information

Dear Colleagues, 

Scientific advances are very important for the health professions. New technologies in implantology and oral health, for example, can make appointments faster and more comfortable for both dentists and patients, in addition to ensuring better results. This present Special Issue, on recent advances in dental implants and oral health, is an opportunity for researchers of different materials and techniques, their academic staff, and clinicians to present their latest findings. Implantology today shows remarkable potential to develop new materials and techniques, opening interesting perspectives for clinical applications. The large and growing link between materials science and the clinical applicability of state-of-the-art materials allows professionals to implement new treatment modalities to benefit patients, bringing a new and very interesting cost–benefit ratio. It is a pleasure to invite you to submit a manuscript to this Special Issue, such as full articles, reviews, and communications in any area of implantology.

Dr. Sérgio Alexandre Gehrke
Guest Editor

Manuscript Submission Information

Manuscripts should be submitted online at www.mdpi.com by registering and logging in to this website. Once you are registered, click here to go to the submission form. Manuscripts can be submitted until the deadline. All submissions that pass pre-check are peer-reviewed. Accepted papers will be published continuously in the journal (as soon as accepted) and will be listed together on the special issue website. Research articles, review articles as well as short communications are invited. For planned papers, a title and short abstract (about 100 words) can be sent to the Editorial Office for announcement on this website.

Submitted manuscripts should not have been published previously, nor be under consideration for publication elsewhere (except conference proceedings papers). All manuscripts are thoroughly refereed through a single-blind peer-review process. A guide for authors and other relevant information for submission of manuscripts is available on the Instructions for Authors page. Medicina is an international peer-reviewed open access monthly journal published by MDPI.

Please visit the Instructions for Authors page before submitting a manuscript. The Article Processing Charge (APC) for publication in this open access journal is 1800 CHF (Swiss Francs). Submitted papers should be well formatted and use good English. Authors may use MDPI's English editing service prior to publication or during author revisions.

Keywords

  • dental implants
  • oral rehabilitation
  • perimplant tissues
  • osseointegration
  • dental materials
  • biomaterials

Published Papers (5 papers)

Order results
Result details
Select all
Export citation of selected articles as:

Research

Jump to: Other

18 pages, 2877 KiB  
Article
The Impact of the Addition of Vitamins on a Silicone Lining Material to the Oral Mucosa Tissue—Evaluation of the Biocompatibility, Hydrolytic Stability and Histopathological Effect
by Irina Gradinaru, Bianca Iulia Ciubotaru, Maria Butnaru, Florina Daniela Cojocaru, Costică Toader Covașă, Teofana Bibire, Mihaela Dascalu, Alexandra Bargan, Maria Cazacu and Mirela-Fernanda Zaltariov
Medicina 2023, 59(11), 1936; https://doi.org/10.3390/medicina59111936 - 01 Nov 2023
Viewed by 1154
Abstract
Background and Objectives: One’s quality of life depends on overall health, and in particular, oral health, which has been and continues to become a public health issue through frequent manifestations in various forms, from simple oral stomatitis (inflammations of the oral cavity) [...] Read more.
Background and Objectives: One’s quality of life depends on overall health, and in particular, oral health, which has been and continues to become a public health issue through frequent manifestations in various forms, from simple oral stomatitis (inflammations of the oral cavity) to the complicated oral health pathologies requiring medical interventions and treatments (caries, pulp necrosis and periodontitis). The aim of this study focused on the preparation and evaluation of vitamins (vitamin A, B1 and B6) incorporated into several silicone-based lining materials as a new alternative to therapeutically loaded materials designed as oral cavity lining materials in prosthodontics. Materials and Methods: Silicone-based liners containing vitamins were prepared by mixing them in solution and becoming crosslinked, and then they were characterized using Fourier-transform infrared (FT-IR) spectroscopy to confirm the incorporation of the vitamins into the silicone network; scanning electron microscopy (SEM) to evidence the morphology of the liner materials; dynamic vapor sorption (DVS) to evaluate their internal hydrophobicity, swelling in environments similar to biological fluids and mechanical test to demonstrate tensile strength; MTT to confirm their biocompatibility on normal cell cultures (fibroblast) and mucoadhesivity; and histopathological tests on porcine oral mucosa to highlight their potential utility as soft lining materials with improved efficiency. Results: FT-IR analysis confirmed the structural peculiarities of the prepared lining materials and the successful incorporation of vitamins into the silicone matrix. The surface roughness of the materials was lower than 0.2 μm, while in cross-section, the lining materials showed a compact morphology. It was found that the presence of vitamins induced a decrease in the main mechanical parameters (strength and elongation at break, Young’s modulus) and hydrophobicity, which varied from one vitamin to another. A swelling degree higher than 8% was found in PBS 6.8 (artificial saliva) and water. Hydrolytic stability studies in an artificial saliva medium showed the release of low concentrations of silicone and vitamin fragments in the first 24 h, which increased the swelling behavior of the materials, diffusion and solubility of the vitamins. The microscopic images of fibroblast cells incubated with vitamin liners revealed very good biocompatibility. Also, the silicone liners incorporating the vitamins showed good mucoadhesive properties. The appearance of some pathological disorders with autolysis processes was more pronounced in the case of vitamin A liners. Conclusions: The addition of the vitamins was shown to have a beneficial effect that was mainly manifested as increased biocompatibility, hydrolytic stability and mucoadhesiveness with the mucosa of the oral cavity and less of an effect on the mechanical strength. The obtained lining materials showed good resistance in simulated biological media but caused a pronounced autolysis phenomenon, as revealed by histopathological examination, showing that these materials may have broad implications in the treatment of oral diseases. Full article
(This article belongs to the Special Issue Recent Advances in Dental Implants and Oral Health)
Show Figures

Graphical abstract

12 pages, 2513 KiB  
Article
Evaluation of Behavior of Castable versus Machined Solid Abutments for Morse Tapper Implant Connection: A Clinical Retrospective Study
by Sergio Alexandre Gehrke, Antonio Scarano, Guillermo Castro Cortellari, Gustavo Vicentis Oliveira Fernandes, Sidney Eiji Watinaga and Marco Aurélio Bianchini
Medicina 2023, 59(7), 1250; https://doi.org/10.3390/medicina59071250 - 05 Jul 2023
Viewed by 1409
Abstract
Objective: The primary objective of the present retrospective clinical study was to evaluate and compare the clinical performance presented by castable abutments developed for the MT system versus intermediate machined abutments, specifically regarding prosthetic or implant fractures/loss; the secondary objective was to [...] Read more.
Objective: The primary objective of the present retrospective clinical study was to evaluate and compare the clinical performance presented by castable abutments developed for the MT system versus intermediate machined abutments, specifically regarding prosthetic or implant fractures/loss; the secondary objective was to verify the looseness of the abutments and the behavior of the peri-implant soft tissues. Methods: This clinical retrospective study was conducted on patients rehabilitated between 2019 and 2020. Inclusion criteria were patients in good general health, with an implants-supporting single crown; with solid machined abutments (control group) or castable UCLA abutments; with a connection portion (base) machined in cobalt-chrome (test group) over Morse taper DuoCone implants in the posterior mandible area; and at least two years in function. Clinical assessment was carried out by the same professional, considering the following parameters: (A) prosthetic: (i) loosening of the fixation screw, (ii) fracture of the screw and (iii) the number of times the patient had some type of complication after the installation of the prostheses were evaluated; (B) biological: (i) without keratinized mucosa (KM), (ii) 1 mm or less, (iii) between 1 and 2 mm and (iv) greater than 2 mm of KM width; and the presence or absence of mucositis. Furthermore, radiographic evaluation was performed in order to assess the marginal bone loss. These evaluations permitted to compare the groups analyzed and patients enrolled. Data were statistically analyzed, with the level of significance set at α = 0.05. Results: 79 patients with 120 MT implants were evaluated (80 castable UCLA abutments and 40 machined solid abutments). The follow-up was from 2 to 4 years. There was a 100% implant survival rate. Therefore, the control group showed two fractured abutments (5%) and no abutment loosening (95% for prosthetic survival rate), whereas the test group showed no abutment fracture but nine loosening screws (11.3%) (100% for prosthetic survival rate). Keratinized mucosa was considered thin or absent in 19 implants in the control group (47.5%) and 42 in the test group (52.5%). Mucositis was found in 11 implants in the control group (27.5%) and 27 in the test group (33.8%). A positive correlation was observed between the width of keratinized mucosa and mucositis (r = 0.521, p = 0.002). The mean marginal bone loss was 2.3 mm, ranging from 1.1 to 5.8 mm. No correlation was observed when considering marginal bone loss versus the three parameters (implant diameter, implant length and time of the prosthesis in function). Conclusions: The results suggest that UCLA-type abutments are a viable option for rehabilitating implants with Morse taper connections, suggesting lower fracture risk. Further research is necessary to confirm these findings and thoroughly evaluate the clinical performance and long-term outcomes. Full article
(This article belongs to the Special Issue Recent Advances in Dental Implants and Oral Health)
Show Figures

Figure 1

12 pages, 9923 KiB  
Article
Influence of Restorative Material on the Distribution of Loads to the Bone in Hybrid Abutment Crowns—In Vitro Study
by Rafael Garcia Martins, Tayna Silva de Castro, Luciano Lauria Dib, Sergio Alexandre Gehrke and Alfredo Mikail Melo Mesquita
Medicina 2023, 59(7), 1188; https://doi.org/10.3390/medicina59071188 - 22 Jun 2023
Cited by 1 | Viewed by 995
Abstract
Background: The objective of this study was to evaluate the load transmitted to the peri-implant bone by seven different restorative materials in single-unit rehabilitations with morse taper implants using a strain gauge. Materials: In a polyurethane block that simulated type III [...] Read more.
Background: The objective of this study was to evaluate the load transmitted to the peri-implant bone by seven different restorative materials in single-unit rehabilitations with morse taper implants using a strain gauge. Materials: In a polyurethane block that simulated type III bone, a morse taper platform implant was installed (3.5 × 11 mm) in the center and 1 mm below the test base surface, and four strain gauges were installed around the implant, simulating the mesial, distal, buccal and lingual positions. Seven similar hybrid abutment crowns were crafted to simulate a lower premolar using different materials: 1—PMMA; 2—glass ceramic over resin matrix; 3—PEEK + lithium disilicate; 4—metal–ceramic; 5—lithium disilicate; 6—zirconia + feldspathic; 7—monolithic zirconia. All groups underwent axial and oblique loads (45 degrees) of 150 N from a universal testing machine. Five measurements (n = 5) were performed with each material and for each load type; the microdeformation data underwent statistical analysis. The data were obtained in microdeformation (με), and the significance level was set at p ≤ 0.05. Results: There was no statistically significant difference in the evaluation among the materials under either the axial load or the oblique load at 45 degrees. In turn, in the comparison between axial load and oblique load, there was a difference in load for all materials. Conclusion: The restorative material did not influence the load transmitted to the bone. Furthermore, the load transmitted to the bone was greater when it occurred obliquely at 45° regardless of the material used. In conclusion, it appeared that the different elastic modulus of each material did not influence the load transmission to the peri-implant bone. Full article
(This article belongs to the Special Issue Recent Advances in Dental Implants and Oral Health)
Show Figures

Figure 1

14 pages, 4417 KiB  
Article
Assessing the Sealing Performance and Clinical Outcomes of Endodontic Treatment in Patients with Chronic Apical Periodontitis Using Epoxy Resin and Calcium Salicylate Seals
by Razvan Mihai Horhat, Bogdan Andrei Bumbu, Laura Orel, Oana Velea-Barta, Laura Cirligeriu, Gratiana Nicoleta Chicin, Marius Pricop, Mircea Rivis, Stefania Dinu, Delia Ioana Horhat, Felix Bratosin, Roxana Manuela Fericean, Rodica Anamaria Negrean and Luminita Maria Nica
Medicina 2023, 59(6), 1137; https://doi.org/10.3390/medicina59061137 - 13 Jun 2023
Viewed by 1584
Abstract
Background and Objectives: Recognizing the significance of a hermetic apical seal for successful root canal treatment, the present investigation aimed to evaluate two sealing materials through an in vitro analysis, as well as to ascertain the clinical outcomes of patients treated with these [...] Read more.
Background and Objectives: Recognizing the significance of a hermetic apical seal for successful root canal treatment, the present investigation aimed to evaluate two sealing materials through an in vitro analysis, as well as to ascertain the clinical outcomes of patients treated with these two sealers in an in vivo setting. Materials and Methods: For the in vitro part of the study, two control groups of thirty monoradicular teeth were obturated with two sealers. Then, the sealers’ performance was tested based on a predefined protocol. Group A included 30 patients treated with an epoxy oligomer resin-based sealer (Adseal, MetaBiomed), while Group S comprised 30 patients treated with a polymeric calcium salicylate-based sealer (Sealapex, Kerr). Samples were sectioned and evaluated under the microscope to determine the sealer’s tightness by measuring the dye penetration into the root canal filling. For the in vivo part, a prospective study was designed to include 60 patients with chronic apical periodontitis in two endodontic treatment groups, using the same two sealers. Results: The in vitro analysis found that dye penetration in Group A was 0.82 mm (±0.428), while in Group S, the dye penetration was statistically significantly deeper, being 1.23 mm (±0.353). In the in vivo part of the study, the periapical index (PAI) significantly decreased 6 months after endodontic treatment, with 80.0% of patients in Group A having a PAI score of 2 compared to only 56.7% in Group S (p-value = 0.018). Similarly, tooth mobility scores significantly decreased after treatment, but with no difference between groups. The marginal bone loss decreased significantly more in the Adseal group compared to the Sealapex group (23.3% vs. 50.0%, p-value = 0.032). At the same time, 40.0% of patients in Group S had failed tooth healing compared to only 13.3% in Group A (p-value = 0.048). Conclusions: The in vitro study showed that Adseal had a better sealing capacity and a lower degree of dye penetration compared to Sealapex. However, on clinical evaluation in the in vivo study, both patient groups exhibited significant improvements in periapical index, tooth mobility scores, and pain reduction following endodontic treatment. Nevertheless, patients treated with Adseal showed a significantly greater improvement in PAI values, tooth mobility, and teeth healing after treatment. Overall, Adseal, as an endodontic sealer, may provide better sealing capabilities and enhanced clinical outcomes in the treatment of chronic apical periodontitis. Full article
(This article belongs to the Special Issue Recent Advances in Dental Implants and Oral Health)
Show Figures

Figure 1

Other

Jump to: Research

11 pages, 976 KiB  
Systematic Review
The Use of Allograft Bone in the Lateral Approach of Sinus Floor Elevation: A Systematic Review of Clinical Studies
by Alexandra-Camelia Pogacian-Maier, Alexandru Mester, Rares-Luca Morariu, Radu Septimiu Campian and Andrei Tent
Medicina 2024, 60(2), 252; https://doi.org/10.3390/medicina60020252 - 31 Jan 2024
Viewed by 645
Abstract
Background and Objectives: The aim of this systematic review was to assess the efficiency of using allografts for sinus lift. Materials and Methods: This systematic review was written under the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and [...] Read more.
Background and Objectives: The aim of this systematic review was to assess the efficiency of using allografts for sinus lift. Materials and Methods: This systematic review was written under the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and recommendation of the Cochrane Handbook for Systematic Reviews of Interventions. Three electronic databases were screened until October 2023. The risk of bias was assessed according to the Strengthening the Reporting of Observational studies in Epidemiology (STROBE) guidelines. Statistical analysis was performed for median bone volume and implant survival rate. Results: From 321 articles retrieved, 7 articles were included in this review. A comparison between freeze-dried bone allograft (FDBA) and deproteinized bovine bone (DBB) for mean bone volume indicated a weighted mean difference (WMD) of −0.17 [−0.69, 0.36] (95% confidence interval (CI)), p = 0.53. For implant survival rate, a comparison was made between FDBA and autogenous bone indicating a risk ratio (RR) of 1.00 [0.96, 1.05] (95% CI), p = 1.00. Conclusions: The available evidence suggested that allograft bone can be used in sinus lift procedures. The results obtained are insufficient to compare with other types of bone graft, requiring a longer follow-up time. Future clinical trials are needed in order to evaluate the advantages of using allograft bone. Full article
(This article belongs to the Special Issue Recent Advances in Dental Implants and Oral Health)
Show Figures

Figure 1

Back to TopTop