Next Issue
Volume 4, December
Previous Issue
Volume 4, June
 
 

Biosensors, Volume 4, Issue 3 (September 2014) – 8 articles , Pages 189-328

  • Issues are regarded as officially published after their release is announced to the table of contents alert mailing list.
  • You may sign up for e-mail alerts to receive table of contents of newly released issues.
  • PDF is the official format for papers published in both, html and pdf forms. To view the papers in pdf format, click on the "PDF Full-text" link, and use the free Adobe Reader to open them.
Order results
Result details
Section
Select all
Export citation of selected articles as:
346 KiB  
Communication
Microelectrode Arrays and the Use of PEG-Functionalized Diblock Copolymer Coatings
by Sakshi Uppal, Matthew D. Graaf and Kevin D. Moeller
Biosensors 2014, 4(3), 318-328; https://doi.org/10.3390/bios4030318 - 11 Sep 2014
Cited by 10 | Viewed by 6120
Abstract
PEG-modified diblock copolymer surfaces have been examined for their compatibility with microelectrode array based analytical methods. The use of PEG-modified polymer surfaces on the arrays was initially problematic because the redox couples used in the experiments were adsorbed by the polymer. This led [...] Read more.
PEG-modified diblock copolymer surfaces have been examined for their compatibility with microelectrode array based analytical methods. The use of PEG-modified polymer surfaces on the arrays was initially problematic because the redox couples used in the experiments were adsorbed by the polymer. This led the current measured by cyclic voltammetry for the redox couple to be unstable and increase with time. However, two key findings allow the experiments to be successful. First, after multiple cyclic voltammograms the current associated with the redox couple does stabilize so that a good baseline current can be established. Second, the rate at which the current stabilizes is consistent every time a particular coated array is used. Hence, multiple analytical experiments can be conducted on an array coated with a PEG-modified diblock copolymer and the data obtained is comparable as long as the data for each experiment is collected at a consistent time point. Full article
Show Figures

Graphical abstract

454 KiB  
Review
Piezoelectric Biosensors for Organophosphate and Carbamate Pesticides: A Review
by Giovanna Marrazza
Biosensors 2014, 4(3), 301-317; https://doi.org/10.3390/bios4030301 - 09 Sep 2014
Cited by 98 | Viewed by 15057
Abstract
Due to the great amount of pesticides currently being used, there is an increased interest for developing biosensors for their detection. Among all the physical transducers, piezoelectric systems have emerged as the most attractive due to their simplicity, low instrumentation costs, possibility for [...] Read more.
Due to the great amount of pesticides currently being used, there is an increased interest for developing biosensors for their detection. Among all the physical transducers, piezoelectric systems have emerged as the most attractive due to their simplicity, low instrumentation costs, possibility for real-time and label-free detection and generally high sensitivity. This paper presents an overview of biosensors based on the quartz crystal microbalance, which have been reported in the literature for organophosphate and carbamate pesticide analysis. Full article
(This article belongs to the Special Issue Piezoelectric Biosensors)
Show Figures

Graphical abstract

1297 KiB  
Review
Biosensors with Built-In Biomolecular Logic Gates for Practical Applications
by Yu-Hsuan Lai, Sin-Cih Sun and Min-Chieh Chuang
Biosensors 2014, 4(3), 273-300; https://doi.org/10.3390/bios4030273 - 27 Aug 2014
Cited by 36 | Viewed by 10165
Abstract
Molecular logic gates, designs constructed with biological and chemical molecules, have emerged as an alternative computing approach to silicon-based logic operations. These molecular computers are capable of receiving and integrating multiple stimuli of biochemical significance to generate a definitive output, opening a new [...] Read more.
Molecular logic gates, designs constructed with biological and chemical molecules, have emerged as an alternative computing approach to silicon-based logic operations. These molecular computers are capable of receiving and integrating multiple stimuli of biochemical significance to generate a definitive output, opening a new research avenue to advanced diagnostics and therapeutics which demand handling of complex factors and precise control. In molecularly gated devices, Boolean logic computations can be activated by specific inputs and accurately processed via bio-recognition, bio-catalysis, and selective chemical reactions. In this review, we survey recent advances of the molecular logic approaches to practical applications of biosensors, including designs constructed with proteins, enzymes, nucleic acids, nanomaterials, and organic compounds, as well as the research avenues for future development of digitally operating “sense and act” schemes that logically process biochemical signals through networked circuits to implement intelligent control systems. Full article
(This article belongs to the Special Issue Electrochemical and Biomedical Sensors)
Show Figures

Figure 1

1487 KiB  
Article
Study of Paclitaxel-Treated HeLa Cells by Differential Electrical Impedance Flow Cytometry
by Julie Kirkegaard, Casper Hyttel Clausen, Romen Rodriguez-Trujillo and Winnie Edith Svendsen
Biosensors 2014, 4(3), 257-272; https://doi.org/10.3390/bios4030257 - 13 Aug 2014
Cited by 24 | Viewed by 8896
Abstract
This work describes the electrical investigation of paclitaxel-treated HeLa cells using a custom-made microfluidic biosensor for whole cell analysis in continuous flow. We apply the method of differential electrical impedance spectroscopy to treated HeLa cells in order to elucidate the changes in electrical [...] Read more.
This work describes the electrical investigation of paclitaxel-treated HeLa cells using a custom-made microfluidic biosensor for whole cell analysis in continuous flow. We apply the method of differential electrical impedance spectroscopy to treated HeLa cells in order to elucidate the changes in electrical properties compared with non-treated cells. We found that our microfluidic system was able to distinguish between treated and non-treated cells. Furthermore, we utilize a model for electrical impedance spectroscopy in order to perform a theoretical study to clarify our results. This study focuses on investigating the changes in the electrical properties of the cell membrane caused by the effect of paclitaxel. We observe good agreement between the model and the obtained results. This establishes the proof-of-concept for the application in cell drug therapy. Full article
(This article belongs to the Special Issue Label-Free Biosensors: Exploring the Field)
Show Figures

Figure 1

645 KiB  
Review
Electrochemical Biosensors Based on Ferroceneboronic Acid and Its Derivatives: A Review
by Baozhen Wang, Shigehiro Takahashi, Xiaoyan Du and Jun-ichi Anzai
Biosensors 2014, 4(3), 243-256; https://doi.org/10.3390/bios4030243 - 30 Jul 2014
Cited by 37 | Viewed by 8808
Abstract
We review recent progress in the development of electrochemical biosensors based on ferroceneboronic acid (FcBA) and ferrocene (Fc)-modified boronic acids. These compounds can be used to construct electrochemical biosensors because they consist of a binding site (i.e., a boronic acid moiety) [...] Read more.
We review recent progress in the development of electrochemical biosensors based on ferroceneboronic acid (FcBA) and ferrocene (Fc)-modified boronic acids. These compounds can be used to construct electrochemical biosensors because they consist of a binding site (i.e., a boronic acid moiety) and an electrochemically active part (i.e., an Fc residue). By taking advantage of the unique properties of FcBA and its derivatives, electrochemical sensors sensitive to sugars, glycated hemoglobin (HbA1c), fluoride (F) ions, and so forth have been widely studied. FcBA-based sugar sensors rely on the selective binding of FcBA to 1,2- or 1,3-diol residues of sugars through the formation of cyclic boronate ester bonds. The redox properties of FcBA-sugar adduct differ from those of free FcBA, which forms the basis of the electrochemical determination of sugars. Thus, non-enzymatic glucose sensors are now being actively studied using FcBA and Fc-modified boronic acids as redox markers. Using a similar principle, HbA1c can be detected by FcBA-based electrochemical systems because it contains hydrocarbon chains on the polypeptide chain. HbA1c sensors are useful for monitoring blood glucose levels over the preceding 8–12 weeks. In addition, FcBA and Fc-modified boronic acids have been used for the detection of F ions due to the selective binding of boronic acid to F ions. F-ion sensors may be useful alternatives to conventional ion-selective electrodes sensitive to F ion. Furthermore, FcBA derivatives have been studied to construct lectin; steroids; nucleotides; salicylic acid; and bacteria sensors. One of the limitations of FcBA-based sensors comes from the fact that FcBA derivatives are added in sample solutions as reagents. FcBA derivatives should be immobilized on the surface of electrodes for developing reagentless sensors. Full article
(This article belongs to the Special Issue Electrochemical and Biomedical Sensors)
Show Figures

Figure 1

824 KiB  
Review
Sensing Magnetic Directions in Birds: Radical Pair Processes Involving Cryptochrome
by Roswitha Wiltschko and Wolfgang Wiltschko
Biosensors 2014, 4(3), 221-242; https://doi.org/10.3390/bios4030221 - 24 Jul 2014
Cited by 66 | Viewed by 16014
Abstract
Birds can use the geomagnetic field for compass orientation. Behavioral experiments, mostly with migrating passerines, revealed three characteristics of the avian magnetic compass: (1) it works spontaneously only in a narrow functional window around the intensity of the ambient magnetic field, but can [...] Read more.
Birds can use the geomagnetic field for compass orientation. Behavioral experiments, mostly with migrating passerines, revealed three characteristics of the avian magnetic compass: (1) it works spontaneously only in a narrow functional window around the intensity of the ambient magnetic field, but can adapt to other intensities, (2) it is an “inclination compass”, not based on the polarity of the magnetic field, but the axial course of the field lines, and (3) it requires short-wavelength light from UV to 565 nm Green. The Radical Pair-Model of magnetoreception can explain these properties by proposing spin-chemical processes in photopigments as underlying mechanism. Applying radio frequency fields, a diagnostic tool for radical pair processes, supports an involvement of a radical pair mechanism in avian magnetoreception: added to the geomagnetic field, they disrupted orientation, presumably by interfering with the receptive processes. Cryptochromes have been suggested as receptor molecules. Cry1a is found in the eyes of birds, where it is located at the membranes of the disks in the outer segments of the UV-cones in chickens and robins. Immuno-histochemical studies show that it is activated by the wavelengths of light that allow magnetic compass orientation in birds. Full article
(This article belongs to the Special Issue Magnetic Biosensors)
Show Figures

Graphical abstract

635 KiB  
Article
An Inexpensive, Fast and Sensitive Quantitative Lateral Flow Magneto-Immunoassay for Total Prostate Specific Antigen
by Jacqueline M. Barnett, Patrick Wraith, Janice Kiely, Raj Persad, Katrina Hurley, Peter Hawkins and Richard Luxton
Biosensors 2014, 4(3), 204-220; https://doi.org/10.3390/bios4030204 - 08 Jul 2014
Cited by 47 | Viewed by 9695
Abstract
We describe the detection characteristics of a device the Resonant Coil Magnetometer (RCM) to quantify paramagnetic particles (PMPs) in immunochromatographic (lateral flow) assays. Lateral flow assays were developed using PMPs for the measurement of total prostate specific antigen (PSA) in serum samples. A [...] Read more.
We describe the detection characteristics of a device the Resonant Coil Magnetometer (RCM) to quantify paramagnetic particles (PMPs) in immunochromatographic (lateral flow) assays. Lateral flow assays were developed using PMPs for the measurement of total prostate specific antigen (PSA) in serum samples. A detection limit of 0.8 ng/mL was achieved for total PSA using the RCM and is at clinically significant concentrations. Comparison of data obtained in a pilot study from the analysis of serum samples with commercially available immunoassays shows good agreement. The development of a quantitative magneto-immunoassay in lateral flow format for total PSA suggests the potential of the RCM to operate with many immunoassay formats. The RCM has the potential to be modified to quantify multiple analytes in this format. This research shows promise for the development of an inexpensive device capable of quantifying multiple analytes at the point-of-care using a magneto-immunoassay in lateral flow format. Full article
(This article belongs to the Special Issue Magnetic Biosensors)
Show Figures

Figure 1

1471 KiB  
Article
Magnetic Properties of FeNi-Based Thin Film Materials with Different Additives
by Cai Liang, Chinthaka P. Gooneratne, Qing Xiao Wang, Yang Liu, Yogesh Gianchandani and Jurgen Kosel
Biosensors 2014, 4(3), 189-203; https://doi.org/10.3390/bios4030189 - 04 Jul 2014
Cited by 17 | Viewed by 7440
Abstract
This paper presents a study of FeNi-based thin film materials deposited with Mo, Al and B using a co-sputtering process. The existence of soft magnetic properties in combination with strong magneto-mechanical coupling makes these materials attractive for sensor applications. Our findings show that [...] Read more.
This paper presents a study of FeNi-based thin film materials deposited with Mo, Al and B using a co-sputtering process. The existence of soft magnetic properties in combination with strong magneto-mechanical coupling makes these materials attractive for sensor applications. Our findings show that FeNi deposited with Mo or Al yields magnetically soft materials and that depositing with B further increases the softness. The out-of-plane magnetic anisotropy of FeNi thin films is reduced by depositing with Al and completely removed by depositing with B. The effect of depositing with Mo is dependent on the Mo concentration. The coercivity of FeNiMo and FeNiAl is reduced to less than a half of that of FeNi, and a value as low as 40 A/m is obtained for FeNiB. The surfaces of the obtained FeNiMo, FeNiAl and FeNiB thin films reveal very different morphologies. The surface of FeNiMo shows nano-cracks, while the FeNiAl films show large clusters and fewer nano-cracks. When FeNi is deposited with B, a very smooth morphology is obtained. The crystal structure of FeNiMo strongly depends on the depositant concentration and changes into an amorphous structure at a higher Mo level. FeNiAl thin films remain polycrystalline, even at a very high concentration of Al, and FeNiB films are amorphous, even at a very low concentration of B. Full article
(This article belongs to the Special Issue Magnetic Biosensors)
Show Figures

Graphical abstract

Previous Issue
Next Issue
Back to TopTop