Next Article in Journal
Organic Semiconducting Nanoparticles for Biosensor: A Review
Next Article in Special Issue
Plasmonic Nanoparticle-Enhanced Optical Techniques for Cancer Biomarker Sensing
Previous Article in Journal
Enzymatic Electrochemical/Fluorescent Nanobiosensor for Detection of Small Chemicals
Previous Article in Special Issue
Recent Progress of Surface-Enhanced Raman Spectroscopy for Bacteria Detection
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Colorimetric Sensing of the Peroxide Number of Milk Powder Using CsPbBr3 Perovskite Nanocrystals

1
Institute of Analytical Technology and Smart Instruments, College of Environment and Public Healthy, Xiamen Huaxia University, Xiamen 361024, China
2
State Key Laboratory of Marine Environmental Science, Xiamen University, Xiamen 361005, China
3
National Quality Supervision and Inspection Center for Incense Products, Yongchun 362600, China
*
Author to whom correspondence should be addressed.
These authors contributed equally to this work.
Biosensors 2023, 13(4), 493; https://doi.org/10.3390/bios13040493
Submission received: 17 March 2023 / Revised: 14 April 2023 / Accepted: 17 April 2023 / Published: 20 April 2023
(This article belongs to the Special Issue High Performance Integrated Biosensors Based on SERS)

Abstract

:
In this study, a wavelength-shift-based colorimetric sensing approach for the peroxide number of milk powder using CsPbBr3 perovskite nanocrystals (CsPbBr3 NCs) has been developed. Through the fat extraction, REDOX reactions and halogen exchange, as well as the optimized experimental conditions, a colorimetric sensing method was established to determine the peroxide number of milk powder samples. The integrated process of milk powder fat extraction and the REDOX process greatly shortened the determination time. This colorimetric method has a good linear correlation in the range of the peroxide number from 0.02 to 1.96 mmol/kg, and the detection limit was found to be 3 μmol/kg. This study further deepens the application prospect of wavelength-shift-based colorimetric sensing using CsPbBr3 NCs.

1. Introduction

Milk powder is a kind of food obtained from fresh animal milk after the moisture removal and drying process. It preserves the high protein and calcium content for dairy usage and has become an important and common human food. Similar to edible oil, milk powder also contains a large amount of fat embedded in the granular structure and a small amount of free fatty acids. Infant milk powders contain more than 20% fat and approximately half of it is unsaturated fatty acids, which makes them more prone to oxidation and deterioration [1,2,3]. In the air, these active unsaturated fatty acids are easily oxidized to peroxides and then degraded into aldehydes and ketones [4], which affects the nutritional value [5] and the taste of the milk powder and reduces the shelf life. As peroxides can destroy the structure of cell membrane, the long-term consumption of foods, including the oxidized milk powder, with excessive peroxides is very harmful to human health [5,6,7] due to the high possibility of cardiovascular diseases, cancer and other chronic diseases. To date, there have emerged several quality testing methods for milk powder [8,9,10,11]. Generally, the oxidation degree of fats or fatty acids could be indicated as a peroxide number, reported as the gram equivalent of iodine in 100 g of a test sample [12], which indicates the quantity of the peroxides in samples. Therefore, the determination of the peroxide number is an important part of the quality control of milk powder to improve quality and prevent potential hazard to human health. At present, the International Standard, ISO 3976:2006 [13], could be known as the most reliable and standardized method for the peroxide number determination of milk powder. In this method, the peroxide in a milk powder sample reacts with ferrous chloride, and the resulting Fe3+ yields a red complex with ammonium thiocyanate. According to ISO 3976:2006, spectrophotometry is a widely used method for the determination of the peroxide number of milk powder, but there are still several limitations, such as: (1) the preparation process for the determination is relatively complex and time-consuming; (2) the test solutions need to be prepared fresh; and (3) the sensitivity is still unsatisfactory. Recently, several approaches for the analysis of edible oil oxidation or type based on electrical conductivity [14] and surface-enhanced Raman spectroscopy (SERS) [15,16,17] have been reported, which provide new routes for the rapid determination of the peroxide number using a device. In addition, simple and rapid colorimetric sensing approaches could also be considered.
Generally, colorimetric sensing provides more convenient and sensitive approaches compared with those based on the luminescence intensity change because the human eye exhibits higher sensitivity to color changes. Recently, colorimetric sensing studies and applications of CsPbBr3 perovskite nanocrystals (CsPbBr3 NCs) have drawn researcher attention [18]. CsPbBr3 PNCs exhibit excellent luminescence properties, such as high quantum yield, narrow full width at half maximum (FWHM) [19,20] and ion exchange [21]. They have been widely used in solar panels [22], light-emitting diodes [23,24], laser fields [25], UV blocking [26], and have revealed excellent application prospects in the field of sensing [18,27,28,29]. The change in the proportion of halogen ions in the CsPbBr3 NCs structure will cause the change in their fluorescence emission wavelength, as shown in Figure 1A, which will cover the whole visible spectrum region and produce a significant color change from blue to red. The above phenomena are very beneficial for the establishment of wavelength-shift-based colorimetric sensing without any additional materials. Recently, several colorimetric sensing studies have been reported using the wavelength-shift of the halogen exchange characteristics of CSPbX3 NCs, in which the concentrations of Cl and methylamine (MA) gas, as well as the peroxide number of edible oil, have been detected [18,29,30,31]. In addition, based on the similar consideration, colorimetric sensing approaches have been developed for the determination of chlorine, iodine and other trace elements in tap water [32], H2S in rat brain microdialysate [27] and benzoyl peroxide in flour and noodle samples [33].
The development of rapid colorimetric sensing approaches for the peroxide number of milk powder will greatly improve the detection efficiency and facilitate the quality control of milk powder. In this study, a colorimetric sensing method using CsPbBr3 NCs was developed and applied to the rapid colorimetric sensing of the milk powder peroxide number. Considering the fat substances need to be extracted from the milk powder for the subsequent process, we established the three processes, including the milk powder fat extraction, REDOX reaction and halogen exchange. As both the process of fat extraction and the REDOX process between oleylammonium iodide (OLAM-I) and peroxides in milk powder can occur in the same organic solvent (n-hexane/isopropanol), the REDOX reaction and the fat extraction from milk powder can be realized at the same time for less pre-preparation time and a simpler determination process. The experimental results reveal that this approach is applicable for the rapid visual determination of the peroxide number of milk powder samples.

2. Materials and Methods

2.1. Materials and Chemicals

Oleic acid (OA, 90%), octadecene (ODE, 90%), oleylamine (OAM, 80–90%), CS2CO3 (99.9%) and PbBr2 (99.99%) were all purchased from Aladin Reagent Co., Ltd. (Shanghai, China). FeCl3, MgSO4, NaCl, Na2S, CaCl2, NaI, KCl, NaNO3, NaNO2, NaClO, Na3PO4•12H2O, NaH2PO4, Na2CO3, NaHCO3 and Zn(NO3)2•6H2O were purchased from Sinoptic Chemical Reagents Co., Ltd. (Shanghai, China). All other reagents were at least analytical grade and without further purification. The water was used throughout the experiments using the water purification system (Millipore, Burlington, MA, USA).

2.2. Instruments

The absorption spectra were characterized by a Hitachi UV-Vis 2550 spectrophotometer. Fluorescent spectra of CsPbBr3 NCs were collected by an F-4500 fluorescence spectrophotometer (Hitachi, Tokyo, Japan). The in-situ halogen exchange between Br and I was observed using a Renishaw Invita Raman (Renishaw, Wotton-under-Edge, UK) spectrometer with a laser excitation source (457 nm). The morphology of CsPbBr3 NCs was characterized by JEOL-1400 transmission electron microscopy (TEM, Tokyo, Japan), and the relevant acceleration voltage was set at 100 kV. A UV-2550 spectrophotometer (Shimadzu, Shenzhen, Japan) was used for the determination of the peroxide number of milk powder following the ISO international method. In the synthesis of CsPbBr3 PNCs, a magnetic stirrer with electric heating sleeve (ZNCL-TS, Shanghai, China) and a high-speed centrifuge (TG16-WS, Hunan, China) were employed.

2.3. Preparation of CsPbBr3 NCs and 9-Octadecenyl Iodide Amine

CsPbBr3 NCs was prepared according to the reference [34], but the dosage was modified in order to obtain the larger amount of products. In the first step, cesium oleate precursor was prepared by adding 0.1628 g of Cs2CO3, 8 mL of octadecene and 0.5 mL of oleic acid into a three-necked flask. The reactants were heated and stirred until Cs2CO3 was completely dissolved at 120 °C under a vacuum condition (about 40 min). Nitrogen was aerated into the flask and kept stirring at 150 °C under the nitrogen atmosphere. In the second step, CsPbBr3 NCs could be obtained by the thermal injection method [26]. In the synthesis, 0.138 g of PbBr2, 10 mL of octadecene, 1 mL of oleic amine and 1 mL of oleic acid were put into a three-necked flask. The reactants in the flask were heated and stirred until PbBr2 was completely dissolved at 120 °C under a vacuum condition (approximately 30 min), and then kept stirring at 150 °C in nitrogen atmosphere. Next, 0.8 mL of cesium oleate precursor solution was quickly injected into the stirred solution, the reaction mixture was quickly cooled down using an ice water bath and then returned to room temperature. The obtained product, CsPbBr3 NCs, was finally purified by high-speed centrifugal separation at 10,000 rpm for 10 min. The product was re-dispersed in n-hexane solution, and 0.5 mg/mL CsPbBr3 NCs was used for further experiments.
Finally, 9-octadecenyl iodide amine (OLAM-I) was synthesized by stirring iodine and oleamine using the high temperature method as in the report [35]. The product was naturally cooled and then diluted by adding a mixture of n-hexane and isopropanol (3:1, v/v) to obtain the final OLAM-I diluent.

2.4. Preparation of Standard Colorimetric Card

In order to guarantee the representative peroxide number for different samples, ten newly purchased milk powder samples of different brands in local supermarkets were collected and mixed. In the preparation of comparative standard milk powder samples, about 10 g of the mixed milk powder sample was placed in a watch glass with a thickness of about 1 cm for the full oxidation with the oxygen in the air. The peroxide number of this milk powder (about 2 mmol/kg) was accurately determined according to ISO 3976:2006. In the preparation of the standard colorimetric card, 0.3 g of the above comparative standard milk powder was mixed with 10 mL of OLAM-I solution, stirred at 1500 rpm in a sealed bottle for 10 min, and then placed for 2 min. The supernatant with a volume of 0 mL (blank), 0.1 mL, 0.2 mL, 0.25 mL, 0.3 mL, 0.35 mL, 0.4 mL, 0.45 mL and 0.5 mL was added into a centrifuge tube, respectively, and then OLAM-I solution was added the centrifuge tube until the total volume was 0.5 mL. A series of standard extracts with different peroxide numbers were prepared, and the peroxides reacted with the excess OLAM-I. The halogen exchange occurred between the excess OLAM-I and 0.5 mg/mL CsPbBr3 NCs to yield CsPbBr3−xIxNCs which emits at a different photoluminescence wavelength. As shown in Figure 1B, after the reaction with OLAM-I and CsPbBr3 NCs, the above prepared supernatant with different peroxide numbers revealed obviously different colors. The corresponding peroxide number for the supernatant could be quantitatively determined using ISO 3976:2006. A standard colorimetric card could be prepared by the present color and the peroxide number obtained by the ISO method. The milk powder sample quality is satisfactory if its peroxide number is lower than 0.5 mmol/kg, while serious oxidation has occurred and it is not suitable for further consumption if the peroxide number is higher than 1 mmol/kg [36]. Therefore, a point line at 1 mmol/kg is highlighted in the standard colorimetric card.

2.5. Colorimetric Sensing for the Peroxide Number of a Milk Powder Sample

In the determination or sensing of the peroxide number, the fat extraction in milk powder is an important procedure, which is different from such samples as edible oils [29]. As the fatty substances in milk powder are embedded in the matrix, a suitable solvent will increase the extraction efficiency. Pearce, D. et al. extracted the fatty substances from milk powder using n-hexane and anhydrous sodium sulfate [37]. Stefania C. et al. used n-hexane/isopropanol as the extraction solvent for the extraction, and the extraction rate was over 80%, which greatly improved the determination accuracy of the peroxide number of milk powder [38].
In the experiments, the process of fat extraction is accompanied by the REDOX reaction. As shown in Figure 2, a certain amount of the milk powder sample was firstly added into OLAM-I n-hexane/isopropanol solution, and the REDOX reaction between OLAM-I and the peroxides in the milk powder sample occurred at the same time in the extraction. The supernatant was then extracted and added to CsPbBr3 NCs for the halogen exchange. Finally, according to the apparent color of CsPbBr3−xIxNCs, the peroxide number of the milk powder sample could be indirectly identified using the colorimetric card. The sensing procedure generally included: (1) about 0.3 g of milk powder sample was added into 0.5 mg/mL OLAM-I solution (n-hexane/isopropanol, v/v 3:1, 10 mL) in a sealed reaction vessel. The suspension was stirred 12 min at a rate of 1500 rpm. The supernatant could be obtained after the suspension was placed for 2 min; then, (2) 0.5 mL of the supernatant was added to 0.5 mg/mL CsPbBr3 NCs solution (in 1 mL n-hexane) for 5 min rapid halogen exchange; and (3) the presented color of the solution under a UV lamp (365 nm) was compared with the colorimetric card to estimate the peroxide number of the milk powder sample. Using the colorimetric card, its quality could be identified according to the color range exceeding the qualified line or not.
As a comparison method, the international standard (ISO 3976:2006) was used for the determination of the peroxide number of the milk powder sample and the detail procedures are shown in the support information.

3. Results and Discussion

3.1. Solvent Selection for the Fat Extraction

The peroxide number of edible oils could be determined by the halogen exchange of CsPbBr3 NCs with the I anions from the residual OLAM-I after the REDOX reaction between OLAM-I and peroxides [29]. After the exchange with CsPbBr3 NCs, the fluorescence emission wavelength of the product, CsPbBrxI3−x NCs, will shift greatly and result in the obvious change of the emission color, which is conducive to colorimetric sensing. Similar to edible oils, after extracted, the fat in milk powder can participate in the REDOX reaction with OLAM-I to affect the degree of halogen exchange with CsPbBr3 NCs. In the colorimetric sensing for milk powder, the fat extraction process can simultaneously make the REDOX reaction with OLAM-I in the same organic solvent, which shortens and simplifies the sensing process. According to the report [37], as shown in Table S1, the fat extraction rate using n-hexane/isopropanol (3:1, v/v) can reach more than 80%, which is the highest rate among the commonly used extraction solvents in the fat extraction. In addition, the polarity of isopropanol should be taken into account because the polar solvent will cause damage to the CsPbBr3 NCs structure. In order to ensure the stability of CsPbBr3 NCs in n-hexane/isopropanol (3:1, v/v), the PL emission spectrum of CsPbBr3 NCs was observed as shown in Figure S2 (the green line), indicating the maximal emission wavelength is at 520 nm, which is the same as that in toluene [29]. No obvious PL intensity change could be observed, even if CsPbBr3 NCs was dissolved and stored in n-hexane/isopropanol for more 6 h. Furthermore, OLAM-I could be completely dissolved after shaking. The halogen exchange reaction between OLAM-I and CsPbBr3 NCs could smoothly occur in n-hexane/isopropanol (3:1, v/v), and the red shift of the PL emission wavelength as shown Figure S2 (the yellow line) could be observed. In this experiment, n-hexane/isopropanol (3:1, v/v) could be selected for the milk powder fat extraction and as a solvent to dissolve OLAM-I and CsPbBr3 NCs for the halogen exchange reaction.
The process of extracting fat from milk powder was accompanied by REDOX reactions between the peroxides in the fat and OLAM-I. With the addition of n-hexane/isopropanol solvent, the fat was released slowly and participated in the REDOX reactions between peroxides in the fat and OLAM-I, and gradually the solution was observed to turn slightly yellow. Generally, a longer extraction time would be helpful to ensure the degree of extraction completion, but unsuitable for high analytical efficiency. Obviously, with the extraction time increase, as shown in Figure S3 (Supplementary Materials), the maximal PL wavelength gradually blue-shifted because the REDOX reactions were approaching completion, and more iodide ions from OLAM-I were consumed, which reduced the halogen exchange with CsPbBr3 NCs to CsPbBr3−xIx NCs. When the extraction time was longer than 12 min, the maximal PL wavelength tended to be stable.
In order to study the effect of temperature on the extraction of fat and the reaction between peroxides in the fat and OLAM-I, the PL spectra of CsPbBr3 NCs at different extraction temperatures (25 °C, 30 °C, 40 °C, 50 °C and 60 °C) were measured. As shown in Figure S4, the maximal PL wavelength of CsPbBr3 PL revealed no significant shift at the different extraction temperature. This result indicates that the extraction temperature in the range of 25 °C to 60 °C has little effect on the sensing result, and the REDOX reactions have completed synchronously. In order to facilitate the practical application, room temperature (about 25 °C) was used as the extraction temperature to further study.
In the fat extraction, a suitable stirring rate would be helpful to release the fat in milk powder. The lower stirring rate caused longer extraction time, but a too high stirring rate would lead to the protein flocculation, which is not conducive to the extraction of fat. In the experiment, the stirring rate of 1500 rpm was selected.
Following the above results, in the sensing of the peroxide number of a milk powder sample, the powder sample was extracted using n-hexane/isopropyl alcohol (3:1, v/v) containing 0.5 mg mL−1 OLAM-I for 12 min at room temperature at a stirring rate of 1500 rpm. After the extraction and the REDOX reactions, the suspension was placed for 2 min and then 0.5 mL of the supernatant from the placed suspension was added to 0.5 mg mL−1 CsPbBr3 NCs solution (in 1 mL n-hexane,) for 5 min halogen exchange reaction.

3.2. Performance Evaluation for the Colorimetric Sensing of the Peroxide Number Using CsPbBr3 NCs

A colorimetric sensing method using CsPbBr3 NCs was established to detect the peroxide number of a milk powder sample based on the above optimized conditions. In the experiment, a series of extract standard samples with different peroxide numbers was prepared following the procedures as described in Section 2.4. The corresponding peroxide numbers of the above standard samples were determined according to ISO 3976:2006. Using the standard samples, the corresponding PL wavelength shift for their different peroxide numbers could be obtained by CsPbBr3 NCs colorimetric sensing method. As shown in Figure 3, the blue shift of the PL wavelength of CsPbBr3 NCs coincides with the peroxide number increase in the standard sample because the higher content of peroxides (larger peroxide number) consumes more I from OLAM-I, which reduces the halogen exchange with CsPbBr3 NCs. Correspondingly, the color presented from red, orange, yellow, green yellow, and finally to light green as shown in Figure 3a (the up figure). The relationship between the quantitative peroxide number of the standard samples and their corresponding maximal PL wavelength is listed in Table S2. The maximal PL wavelength was found to be 633 nm when the peroxide number was 0. With the increase of the peroxide number to 1.96 mmol/kg, the maximal PL wavelength shifted to 519 nm. As shown in Figure 3b, the peroxide number of the standard sample presented a good linear relationship in the range from 0.02 mmol/kg to 1.96 mmol/kg with the PL wavelength shift, and the linear regression equation of y = 53.72x (y, wavelength shift, x, peroxide number) with a correlation coefficient (R2) of 0.989 could be obtained. The limit of detection (LOD) of the peroxide number is 3 μmol kg−1 (LOD = 3σ/k, k = 53.72, the slope of linear equation, σ is relative standard deviation).

3.3. Reproducibility of the Colorimetric Sensing Approach

In order to investigate the reproducibility of the sensing method, the multiple sensing tests for a same batch of milk powder sample were carried out. After six parallel samplings and extractions for the samples, each of the 0.5 mL supernatants was added to CsPbBr3 NCs solution, respectively. After the halogen exchange, their PL spectra and presented colors were observed and recorded. In addition, one of the above six supernatant samples was selected and tested six times to investigate the reproducibility of the same extraction. As shown in Table S3, the relative standard deviation (RSD) of the maximal PL wavelength for the same batch of milk powder sample was found to be 0.16%, and the RSD of the maximal PL wavelength for the six supernatant samples was 0.11%. The RSD values are all less 0.2%.

3.4. Colorimetric Sensing of the Peroxide Number for Milk Powder Samples Using CsPbBr3 NCs

Based on the above optimal experimental conditions, the colorimetric sensing method of the peroxide number for milk powder samples using CsPbBr3 NCs was established. As shown in Figure S5 and Video S1, the whole detection process took about 20 min, including the fat extraction and REDOX reaction, halogen exchange and colorimetric process. The peroxide number of milk powder samples could be tested by comparing with the final sensing color and the standard colorimetric card. As listed in Table 1, several milk powder samples were newly purchased with sealed packaging from local markets. Sample 1 was a defatted milk powder and sample 2 to sample 4 were whole milk powder samples. Sample 5 was prepared by exposing the whole milk powder sample (sample 2) to air for two weeks. Comparing with the standard colorimetric card as shown in Figure 1, the red color of the test solution indicates the low peroxide number and edibility, but the light yellow color, as in sample 5, indicates the critical level of peroxides for safe consumption. As listed in Table 1, the colorimetric sensing color was bright red for sample 1, red for sample 2, pink for sample 3, reddish orange for sample 4 and dark yellow for sample 5. The sensing results show that the peroxide number is very low for the defatted milk powder sample (sample 1). Although the peroxide number for samples 2, 3 and 4 is obvious larger than that of sample 1, the values are all in the safe range (lower 0.5 mmol/kg). The peroxide number of sample 2 increased from 0.2 mmol/kg to 1.1 mmol/kg after it was exposed to air for two weeks, indicating the obvious influence of oxygen. The sensing results are consistent with those from ISO 3976:2006, by which the peroxide number of sample was found to be 0.05, 0.15, 0.32 and 0.45 mmol/kg for sample 1 to sample 4, respectively, and the highest peroxide number of 1.04 mmol/kg of sample 5 was obtained.

4. Conclusions

In this study, a colorimetric sensing method using CsPbBr3 NCs was developed and successfully applied to the rapid determination of the peroxide number for milk powder. The synchronized process of the fat extraction and the REDOX reactions between the peroxides and OLAM-I simplified the procedure and reduced the sensing time. The entire procedure could be finished in 20 min. The PL color could be directly compared with the standard colorimetric card to obtain the peroxide number of the milk powder samples, by which the peroxides in the sample could be evaluated. In addition, the quantitative analysis for the peroxide number of the milk powder samples could be realized based on the PL wavelength shift, and the experimental results revealed that the wavelength shift presented a good linear correlation in the range of the peroxide number from 0.02 to 1.956 mmol/kg, and the detection limit was found to be 3 μmol/kg.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/bios13040493/s1, Figure S1: Calibration curve of spectrophotography; Figure S2: The fluorescence emission spectra of CsPbBr3 NCs (green line) and red shift of induced by OLAM-I (orange-yellow line) in n-hexane/isopropanol (v/v); Figure S3: Maximal PL wavelength at different extraction time; Firure S4: Maxmal PL emission wavelength of CsPbBr3 NCs after the halogen exchange with OLAM-I at the different extraction temperature; Figure S5: Photo records of the colorimetric sensing for peroxide number of powder milk using CsPbBr3 NCs; Table S1: Extraction rate of fat using different organic solvent [15,16,17]; Table S2: Peroxide number, wavelength and wavelength shift of the standard samples; Table S3: Reproducibility of the colorimetric sensing method; Video S1: Video record of the colorimetric sensing for peroxide number of powder milk using CsPbBr3 NCs.

Author Contributions

Conceptualization, data curation, writing-original draft, L.Z.; methodology, data curation, formal analysis, review & editing, Y.Z.; methodology, visualization, review &editing, Z.G.; methodology, material collection, L.Y.; formal analysis, sampling, C.Z.; supervision, funding acquisition, project administration, X.C. All authors have read and agreed to the published version of the manuscript.

Funding

This work was financially supported by the National Natural Science Foundation of China (No. 21876141, No. 22004105).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data are available under request to the correspondence.

Conflicts of Interest

The authors declared that they do not have any competing commercial or associative interest that could influence the work reported in this paper.

References

  1. Nadal, M.R.; Servin, J.L.C.; Castellote, A.I.; Rivero, M.; López-Sabater, M.C. Oxidation stability of the lipid fraction in milk powder formulas. Food Chem. 2007, 100, 756–763. [Google Scholar] [CrossRef]
  2. Yin, H.Y.; Porter, N.A. New insights regarding the autoxidation of polyunsaturated fatty acids. Antioxid. Redox Signal 2005, 7, 170–184. [Google Scholar] [CrossRef] [PubMed]
  3. Duan, X.X.; Zhang, Y.C.; Dai, Z.Y.; Pan, L.N. Study on Influential Factors and Progress of Fat Oxidation in Infant Formula. China Dairy Ind. 2011, 39, 27–30. [Google Scholar]
  4. Guillen, M.D.; Cabo, N. Usefulness of the frequency data of the Fourier transform infrared spectra to evaluate the degree of oxidation of edible oils. J. Agric. Food Chem. 1999, 47, 709–719. [Google Scholar] [CrossRef]
  5. Gotoh, N.; Watanabe, H.; Osato, R.; Inagaki, K.; Iwasawa, A.; Wada, S. Novel approach on the risk assessment of oxidized fats and oils for perspectives of food safety and quality. I. Oxidized fats and oils induces neurotoxicity relating pica behavior and hypoactivity. Food Chem. Toxicol. 2006, 44, 493–498. [Google Scholar] [CrossRef] [PubMed]
  6. Tao, F.F.; Zhang, Y.L. Detection of Fat Peroxide Value in Infant Formula and Its Significance. Mod. Food 2018, 24, 131–132+5. [Google Scholar] [CrossRef]
  7. Rohfritsch, Z.; Schafer, O.; Giuffrida, F. Analysis of Oxidative Carbonyl Compounds by UPLC-High-Resolution Mass Spectrometry in Milk Powder. J. Agric. Food Chem. 2019, 67, 3511–3520. [Google Scholar] [CrossRef]
  8. Jablonski, J.E.; Moore, J.C.; Harnly, J.M. Nontargeted Detection of Adulteration of Skim Milk Powder with Foreign Proteins Using UHPLC-UV. J. Agric. Food Chem. 2014, 62, 5198–51206. [Google Scholar] [CrossRef]
  9. Qin, J.Y.; Xie, L.J.; Ying, Y.B. Feasibility of Terahertz Time-Domain Spectroscopy to Detect Tetracyclines Hydrochloride in Infant Milk Powder. Anal. Chem. 2014, 86, 11750–11757. [Google Scholar] [CrossRef]
  10. Scholl, P.F.; Farris, S.M.; Mossoba, M.M. Rapid Turbidimetric Detection of Milk Powder Adulteration with Plant Proteins. J. Agric. Food Chem. 2014, 62, 1498–1505. [Google Scholar] [CrossRef]
  11. Scholl, P.F.; Bergana, M.M.; Yakes, B.J.; Xie, Z.; Zbylut, S.; Downey, G.; Mossoba, M.; Jablonski, J.; Magaletta, R.; Holroyd, S.E.; et al. Effects of the Adulteration Technique on the Near-Infrared Detection of Melamine in Milk Powder. J. Agric. Food Chem. 2017, 65, 5799–5809. [Google Scholar] [CrossRef] [PubMed]
  12. GB 5009.227-2016; National Food Safety Standards—Determination of Peroxidation Value in Foods (in China). National Health and Family Planning Commission of the People’s Republic of China. Standards Press of China: Beijing, China, 2016.
  13. ISO 3976:2006; Milk Fat—Determination of Peroxide Value. International Organization for Standardization: Geneva, Switzerland, 2006.
  14. Wang, M.Z.; Huyan, Z.Y.; Jing, B.Y.; Mao, X.H.; Yu, X.Z. Analysis of Edible Oil Oxidation Based on Changes in the Electrical Conductivity of the Extracted Aqueous Phase. Eur. J. Lipid Sci. Technol. 2019, 121, 1800441. [Google Scholar] [CrossRef]
  15. Jiang, H.; He, Y.C.; Xu, W.D.; Chen, Q.S. Quantitative Detection of Acid Value During Edible Oil Storage by Raman Spectroscopy: Comparison of the Optimization Effects of BOSS and VCPA Algorithms on the Characteristic Raman Spectra of Edible Oils. Food Anal. Methods 2021, 14, 1826–1835. [Google Scholar] [CrossRef]
  16. Jiang, Y.; Su, M.; Yu, T.; Du, S.; Liao, L.; Wang, H.; Wu, Y.; Liu, H. Quantitative determination of peroxide value of edible oil by algorithm-assisted liquid interfacial surface enhanced Raman spectroscopy. Food Chem. 2021, 344, 128709. [Google Scholar] [CrossRef]
  17. Du, S.; Su, M.; Jiang, Y.; Yu, F.; Xu, Y.; Lou, X.; Yu, T.; Liu, H. Direct Discrimination of Edible Oil Type, Oxidation, and Adulteration by Liquid Interfacial Surface-Enhanced Raman Spectroscopy. ACS Sens. 2019, 4, 1798–1805. [Google Scholar] [CrossRef]
  18. Huang, Y.; Wang, S.; Zhu, Y.; Li, F.; Jin, J.; Dong, J.; Lin, F.; Wang, Y.; Chen, X. Dual-Mode of Fluorescence Turn-On and Wavelength-Shift for Methylamine Gas Sensing Based on Space-Confined Growth of Methylammonium Lead Tribromide Perovskite Nanocrystals. Anal. Chem. 2020, 92, 5661–5665. [Google Scholar] [CrossRef]
  19. Li, X.; Cao, F.; Yu, D.; Chen, J.; Sun, Z.; Shen, Y.; Zhu, Y.; Wang, L.; Wei, Y.; Wu, Y.; et al. All Inorganic Halide Perovskites Nanosystem: Synthesis, Structural Features, Optical Properties and Optoelectronic Applications. Small 2017, 13, 24. [Google Scholar] [CrossRef] [PubMed]
  20. Zhang, Q.; Yin, Y.D. All-Inorganic Metal Halide Perovskite Nanocrystals: Opportunities and Challenges. ACS Cent. Sci. 2018, 4, 668–679. [Google Scholar] [CrossRef]
  21. Akkerman, Q.A.; D'Innocenzo, V.; Accornero, S.; Scarpellini, A.; Petrozza, A.; Prato, M.; Manna, L. Tuning the Optical Properties of Cesium Lead Halide Perovskite Nanocrystals by Anion Exchange Reactions. J. Am. Chem. Soc. 2015, 137, 10276–10281. [Google Scholar] [CrossRef]
  22. Hu, Y.; Bai, F.; Liu, X.; Ji, Q.; Miao, X.; Qiu, T.; Zhang, S. Bismuth Incorporation Stabilized alpha-CsPbI3 for Fully Inorganic Perovskite Solar Cells. ACS Energy Lett. 2017, 2, 2219–2227. [Google Scholar] [CrossRef]
  23. Zhang, X.; Lin, H.; Huang, H.; Reckmeier, C.; Zhang, Y.; Choy, W.C.; Rogach, A.L. Enhancing the Brightness of Cesium Lead Halide Perovskite Nanocrystal Based Green Light-Emitting Devices through the Interface Engineering with Perfluorinated Ionomer. Nano Lett. 2017, 17, 598. [Google Scholar] [CrossRef]
  24. Liang, F.-C.; Jhuang, F.-C.; Fang, Y.-H.; Benas, J.-S.; Chen, W.-C.; Yan, Z.-L.; Lin, W.-C.; Su, C.-J.; Sato, Y.; Chiba, T.; et al. Synergistic Effect of Cation Composition Engineering of Hybrid Cs1−xFAxPbBr3 Nanocrystals for Self-Healing Electronics Application. Adv. Mater. 2023, 35, 2207617. [Google Scholar] [CrossRef] [PubMed]
  25. Yang, C.P.; Yin, Y.X.; Zhang, S.F.; Li, N.W.; Guo, Y.G. Accommodating lithium into 3D current collectors with a submicron skeleton towards long-life lithium metal anodes. Nat. Commun. 2015, 6, 9. [Google Scholar] [CrossRef] [PubMed]
  26. Huang, G.; Huang, Y.; Xu, W.; Yao, Q.; Liu, X.; Ding, C.; Chen, X. Cesium lead halide perovskite nanocrystals for ultraviolet and blue light blocking. Chin. Chem. Lett. 2019, 30, 1021–1023. [Google Scholar] [CrossRef]
  27. Chen, C.; Cai, Q.; Luo, F.; Dong, N.; Guo, L.; Qiu, B.; Lin, Z. Sensitive Fluorescent Sensor for Hydrogen Sulfide in Rat Brain Microdialysis via CsPbBr3 Quantum Dots. Anal. Chem. 2019, 91, 15915–15921. [Google Scholar] [CrossRef]
  28. Chen, X.; Hu, H.W.; Xia, Z.M.; Gao, W.; Gou, W.; Qua, Y.; Ma, Y. CsPbBr3 perovskite nanocrystals as highly selective and sensitive spectrochemical probes for gaseous HCl detection. J. Mater. Chem. C 2017, 5, 309–313. [Google Scholar] [CrossRef]
  29. Zhu, Y.; Li, F.; Huang, Y.; Lin, F.; Chen, X. Wavelength-Shift-Based Colorimetric Sensing for Peroxide Number of Edible Oil Using CsPbBr3 Perovskite Nanocrystals. Anal. Chem. 2019, 91, 14183–14187. [Google Scholar] [CrossRef] [PubMed]
  30. Li, F.; Feng, Y.; Huang, Y.; Yao, Q.; Huang, G.; Zhu, Y.; Chen, X. Colorimetric sensing of chloride in sweat based on fluorescence wavelength shift via halide exchange of CsPbBr3 perovskite nanocrystals. Microchim. Acta 2021, 188, 8. [Google Scholar] [CrossRef]
  31. Jin, J.; Lin, J.; Huang, Y.; Zhang, L.; Jiang, Y.; Tian, D.; Lin, F.; Wang, Y.; Chen, X. High sensitivity ratiometric fluorescence temperature sensing using the microencapsulation of CsPbBr3 and K2SiF6, Mn4+ phosphor. Chin. Chem. Lett. 2022, 33, 4798–4802. [Google Scholar] [CrossRef]
  32. Yin, W.; Li, H.; Chesman, A.S.R.; Tadgell, B.; Scully, A.D.; Wang, M.; Huang, W.; McNeill, C.R.; Wong, W.W.H.; Medhekar, N.V.; et al. Detection of Halomethanes Using Cesium Lead Halide Perovskite Nanocrystals. ACS Nano 2021, 15, 1454–1464. [Google Scholar] [CrossRef]
  33. Zhang, L.; Zhu, Y.; Li, F.; Zhang, L.; You, L.; Guo, Z.; Huang, Y.; Zhao, L.; Chen, X. Colorimetric Sensing of Benzoyl Peroxide Based on the Emission Wavelength-Shift of CsPbBr3 Perovskite Nanocrystals. Chemosensors 2021, 9, 319. [Google Scholar] [CrossRef]
  34. Protesescu, L.; Yakunin, S.; Bodnarchuk, M.I.; Krieg, F.; Caputo, R.; Hendon, C.H.; Yang, R.X.; Walsh, A.; Kovalenko, M.V. Nanocrystals of Cesium Lead Halide Perovskites (CsPbX3, X = Cl, Br, and I): Novel Optoelectronic Materials Showing Bright Emission with Wide Color Gamut. Nano Lett. 2015, 15, 3692–3696. [Google Scholar] [CrossRef] [PubMed]
  35. Akkerman, Q.A.; Martínez-Sarti, L.; Goldoni, L.; Imran, M.; Baranov, D.; Bolink, H.J.; Palazon, F.; Manna, L. Molecular Iodine for a General Synthesis of Binary and Ternary Inorganic and Hybrid Organic-Inorganic Iodide Nanocrystals. Chem. Mater. 2018, 30, 6915–6921. [Google Scholar] [CrossRef]
  36. Li, T.M.; Xu, Y.M.; Wang, L.Y. Significance and Method for Determination of Peroxide Value in Infant Formula Milk Powder. The Third China Dairy Industry Conference; Dairy Association of China: Zhengzhou, China, 2012; pp. 203–205. [Google Scholar]
  37. Kim, E.H.J.; Chen, X.D.; Pearce, D. Surface composition of industrial spray-dried milk powders. 3. Changes in the surface composition during long-term storage. J. Food Eng. 2009, 94, 182–191. [Google Scholar] [CrossRef]
  38. Cesa, S.; Casadei, M.A.; Cerreto, F.; Paolicelli, P. Influence of fat extraction methods on the peroxide value in infant formulas. Food Res. Int. 2012, 48, 584–591. [Google Scholar] [CrossRef]
Figure 1. Halogen exchange of CsPbBr3 NCs with I (A), and a standard colorimetric card for different peroxide numbers (B).
Figure 1. Halogen exchange of CsPbBr3 NCs with I (A), and a standard colorimetric card for different peroxide numbers (B).
Biosensors 13 00493 g001
Figure 2. General procedure for the colorimetric sensing of the peroxide number of milk powder.
Figure 2. General procedure for the colorimetric sensing of the peroxide number of milk powder.
Biosensors 13 00493 g002
Figure 3. (a) The blue shift of the PL wavelength of CsPbBr3 NC with the increase of the peroxide number, and (b) linear relationship between the wavelength shift and the peroxide number.
Figure 3. (a) The blue shift of the PL wavelength of CsPbBr3 NC with the increase of the peroxide number, and (b) linear relationship between the wavelength shift and the peroxide number.
Biosensors 13 00493 g003
Table 1. Determination of the peroxide number for milk powder.
Table 1. Determination of the peroxide number for milk powder.
Sample 1Sample 2Sample 3Sample 4Sample 5
Sensing colorBiosensors 13 00493 i001Biosensors 13 00493 i002Biosensors 13 00493 i003Biosensors 13 00493 i004Biosensors 13 00493 i005
Sensing results (mmol/kg)0.10.20.30.41.1
ISO test result (mmol/kg)0.050.150.320.451.04
QualityEdibleEdibleEdibleEdibleInedible
Sample 1, new defatted milk powder; Sample 2, 3 and 4, different brand of new whole milk powder samples; Sample 5, the sample 2 was stored in air for 2 weeks.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Zhang, L.; Zhu, Y.; Guo, Z.; You, L.; Zhang, C.; Chen, X. Colorimetric Sensing of the Peroxide Number of Milk Powder Using CsPbBr3 Perovskite Nanocrystals. Biosensors 2023, 13, 493. https://doi.org/10.3390/bios13040493

AMA Style

Zhang L, Zhu Y, Guo Z, You L, Zhang C, Chen X. Colorimetric Sensing of the Peroxide Number of Milk Powder Using CsPbBr3 Perovskite Nanocrystals. Biosensors. 2023; 13(4):493. https://doi.org/10.3390/bios13040493

Chicago/Turabian Style

Zhang, Li, Yimeng Zhu, Zhiyong Guo, Longjie You, Chen Zhang, and Xi Chen. 2023. "Colorimetric Sensing of the Peroxide Number of Milk Powder Using CsPbBr3 Perovskite Nanocrystals" Biosensors 13, no. 4: 493. https://doi.org/10.3390/bios13040493

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop