Next Article in Journal
Capture-SELEX: Selection Strategy, Aptamer Identification, and Biosensing Application
Next Article in Special Issue
Sandwich-Type Electrochemiluminescence Immunosensor Based on CDs@dSiO2 Nanoparticles as Nanoprobe and Co-Reactant
Previous Article in Journal
Electrochemical Ultrasensitive Sensing of Uric Acid on Non-Enzymatic Porous Cobalt Oxide Nanosheets-Based Sensor
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Electrochemiluminescence Aptasensor Based on Gd(OH)3 Nanocrystalline for Ochratoxin A Detection in Food Samples

College of Chemistry and Chemical Engineering, Yantai University, Yantai 264005, China
*
Authors to whom correspondence should be addressed.
Biosensors 2022, 12(12), 1141; https://doi.org/10.3390/bios12121141
Submission received: 16 November 2022 / Revised: 2 December 2022 / Accepted: 2 December 2022 / Published: 7 December 2022

Abstract

:
In the present study, the electrochemiluminescence (ECL) properties of Gd(OH)3 nanocrystals with K2S2O8 as the cathode coreactant were studied for the first time. Based on the prominent ECL behavior of this material and the excellent specificity of the aptamer technique, an ECL aptasensor for the detection of ochratoxin A (OTA) was formulated successfully. Over an OTA concentration range of 0.01 pg mL−1 to 10 ng mL−1, the change in the ECL signal was highly linear with the OTA concentration, and the limit of detection (LOD) was 0.0027 pg mL−1. Finally, the ECL aptasensor was further used to detect OTA in real samples (grapes and corn) and satisfactory results were obtained, which indicated that the built method is expected to be applied in food detection.

1. Introduction

Ochratoxin, as a kind of secondary metabolite produced by several species of aspergillus and penicillium, has attracted extensive attention due to its toxicity and serious threat to human health [1,2]. Among these secondary metabolites, ochratoxin A (OTA) is the most common toxic substance that can be found in moldy or fermented agricultural products [3], and it has been proved to be very toxic to the human body, especially to people living in humid and warm environments [4,5]. In addition, OTA can be found throughout the food chain as it contaminates not only food, fruit, and feed, but also coffee, wine grapes, and dried grapes. These OTA-contaminated foods or medicines can cause severe symptoms of either acute or chronic poisoning once someone has consumed them. Therefore, rapid and sensitive detection of OTA in agricultural products and foods is of great significance. Now, the reported detection methods of OTA include high performance liquid chromatography [6], gas chromatography [7], antibody-based enzyme-linked immunosorbent assay [8,9], fluorescence assay [10,11], etc. However, most of these methods may have some disadvantages such as being expensive and time-consuming, requiring bulky equipment, having complicated sample pretreatment steps, as well as some methods only being able to be operated by qualified staff in professional laboratories. Thus, it is urgent to find a simple, rapid, and sensitive detection method.
In order to address these limitations and challenges, various sensors using antibodies or aptamers as capturing probes have focused on the specific recognition and sensitive detection of target small molecules in different substrates such as OTA [12,13,14,15,16]. Among them is the ECL aptasensor, a new technology that combines electrochemistry and chemiluminescence and has received extensive attention. It has the advantages of having a simple operation, strong and stable response, and low background signal [15]. For this, ECL as a high sensitivity detection method has been widely used in many fields [17,18]. It has been reported that aptamers (single-stranded oligonucleotide fragments or short peptides) can be used for the highly selective analysis of OTA [19]. Compared with antibodies, there are some advantages of aptamers, including having a high binding affinity, strong specificity, non-toxicity, etc., that can be applied to cells, proteins, tissues, and small molecules [20,21,22]. By combining the unique advantages of ECL with the specific recognition ability of aptamer, the ECL aptasensor is a general strategy for the sensitive detection of various target molecules.
For the purpose of constructing novel ECL aptasensors, it is very important to select suitable luminescent materials. In recent years, rare earth nanomaterials have attracted extensive attention due to their excellent physical and chemical properties [23,24,25]. For instance, some rare earth compounds have been widely used in high-performance light-emitting devices, catalysts, and other functional materials [26]. It is notable that rare earth hydroxide (Re (OH)3) has important application value. Yang and his coworkers [27] tested the biological distribution and toxicity of Gd(OH)3 nanorods in vivo and found no toxic effect. They concluded that the nanorods could be used for long-term in-body imaging. In addition, Gd(OH)3, as a luminescent material, has been applied in many fields due to its simple synthesis method. However, its application in ECL has not been found yet. Therefore, it is of great significance to use Gd(OH)3 as an ECL emitter for OTA detection.
In this work, the Gd(OH)3 nanocrystals were synthesized by the glucose-assisted hydrothermal method and its ECL performance was further studied. Based on highly stable and repeatable ECL emission of Gd(OH)3 nanocrystals and excellent specificity of the aptamer technique, an ECL aptasensor for OTA detection was constructed. Scheme 1 shows the construction process of an ECL aptasensor. On the one hand, OTA aptamer was coupled with glutaraldehyde (GA) as a crosslinking agent. On the other hand, when the aptamer and OTA were interconnected, ECL intensity would be quenched, which meant high sensitivity and good specificity for OTA detection. The ECL aptasensor was successfully applied to OTA detection of grain and fruit (corn and grapes) with good accuracy. We hope this method can be applied in food detection.

2. Materials and Methods

2.1. Materials

Gadolinium nitrate hexahydrate (Gd(NO3)3·6H2O) was purchased from Shanghai Aladdin Biochemical Technology Co., Ltd. (Shanghai, China). Glucose, sodium hydroxide (NaOH), and absolute ethanol (C2H5OH) were purchased from Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). Glutaraldehyde (GA) was obtained from Xilong Chemical Co., Ltd. (Shantou, China). Ochratoxin A (OTA), chloramphenicol (CHL), penicillin (PE), kanamycin (KAN), neomycin (NEO), and tetracycline (TC) were purchased from Shanghai Sangon Bioengineering Co., Ltd. (Shanghai, China). The base sequence (5′-3′) of the aptamer DNA was 5′-NH2-(CH2)6-GAT CGG GTG TGG GTG GCG TAA AGG GAG CAT CGG ACA-3′.

2.2. Apparatus

The size and morphology of the resulting products were captured using an S-4800 scanning electron microscope (HITACHI, Tokyo, Japan). The spectral characteristics of the materials were characterized by Fourier transform infrared (FT-IR; Thermo Electron Corporation, Waltham, MA, USA), ultraviolet–visible absorption spectra (UV–vis; Purkinje General Instrument Co., Ltd., Beijing, China), and fluorescence (F-4700 fluorescence spectrophotometer; HITACHI, Tokyo, Japan), respectively. X-ray diffraction (Rigaku Corporation, Tokyo, Japan) was used to characterize the phase and structure of the prepared nanocomposite. An MPI-E ECL analyzer (Xi’an Remax Analyse Instrument Co., Ltd., Xi’an, China) was used for the ECL measurement.

2.3. Synthesis of Gd(OH)3

Gd(OH)3 nanocrystals were synthesized according to Ref [28]. Briefly, 0.5641 g Gd(NO3)3·6H2O was added into 16 mL ultrapure water to prepare the solution. Next, NH3·H2O was used to adjust the pH value of the solutions between 3 and 4. A homogeneous solution was prepared by stirring the mixture solution of 14 mL 0.01 M glucose and the above solution for 10 min. The final pH of this homogeneous solution was adjusted to 11 by NaOH. Then, it was transferred to a hydrothermal reaction kettle and reacted at 180 °C for 9 h. The product was cooled down and washed with ethanol and water three times. The final product was dried at 120 °C for 2 h, and the obtained white powder was Gd(OH)3 nanocrystals, which was stored in the refrigerator at 4 °C.

2.4. Fabrication of ECL Aptasensors

Firstly, the polished glass carbon electrode (GCE) was modified with 5 μL Gd(OH)3 solution (1 mg mL−1) dissolved by ethanol and dried naturally. Next, 5 μL GA (2%), as a crosslinking agent, was dripped in GCE modified with Gd(OH)3 reacting for 2 h. Then, the excess GA was washed by PBS (0.1 M, pH 7.4) solution, the obtained GCE was named Gd(OH)3/GCE. Subsequently, the obtained Gd(OH)3/GCE incubated in 5 μL adapter solution for 2 h at 37 °C. Due to the presence of GA, the adapter could be fixed to the surface of Gd(OH)3/GCE, which was named Apt/Gd(OH)3/GCE. Finally, the obtained Apt/Gd(OH)3/GCE was used as ECL material and incubated in 100 μL of different concentrations of OTA solutions for 2 h at 37 °C to fabricate a novel ECL aptasensor. It is worth mentioning that after each incubation step, the GCE was washed with PBS (0.1 M, pH 7.4), avoiding non-specific binding, and, finally, dried under nitrogen. Other experimental conditions were as follows: the scanning potential was −2.0~0 V, the scanning speed was 100 mV S−1, and the photomultiplier tube was 800 V.

2.5. Determination of OTA in Real Samples

In this study, for the purpose of evaluation of the performance of the proposed method, the samples were obtained from local market in Yantai City (corn and grapes). The samples were filtered through a 0.45 μm membrane before further use. Then, they were diluted 10 times with PBS (0.1 M, pH 7.4) and stored at −20 °C for further use.

3. Results

3.1. Characterization of Gd(OH)3

The morphology of the prepared Gd(OH)3 nanocrystals was characterized by SEM as shown in Figure 1A. The morphologies of the preparations were columnar (the column length is about 200 nm and the diameter is about 50 nm), evenly dispersed, and have a large, specific surface area. An energy dispersive spectrometer (EDS) was used to verify the element content of Gd(OH)3, as shown in Figure 1B. It could be seen that Gd and O elements were present in the nanocrystalline state, which conformed to expectation, providing that the Gd(OH)3 nanocrystals were successfully synthesized.
XRD was then used to further verify the successful synthesis of Gd(OH)3 nanocrystals and the results are shown in Figure 2A. As can be seen from the figure, all diffraction peaks were consistent with the Joint Committee on Powder Diffraction Standards card n0 83-2037 [29]. Furthermore, the shape of diffraction peaks of samples was sharp and intense, proving that the prepared Gd(OH)3 samples had high crystallinity. Figure 2B shows the image of the FT-IR spectrum. As we know, at 3615 cm−1, the O-H stretching vibration peak was very obvious [30], while the peak located at 710 cm−1 might be attributed to Gd-O-H bending vibrations [31]. It should be noted that there was a very large peak at 3250 cm−1 with a peak of H2O, which might be caused by the accuracy of the experimental instrument. In addition, the UV–vis spectra of Gd(OH)3 nanocrystals was recorded, which further confirmed the successful preparation of nanocrystals, as shown in Figure 2C. In the figure, there was usually extensive absorption below 400 nm, and this absorption can be attributed to the 4f → 5d transition. In addition, there was a small sharp peak at 275 nm, which was a sign of the transition of Gd (III) from the ground state to the excited state [26]. Figure 2D shows the fluorescence spectra of Gd(OH)3 nanocrystals, and it can be seen that the excitation peak was located at 435 nm and the fluorescence color was blue.

3.2. Optimizations of Conditions

In order to obtain the optimal ECL intensity, GCE modified with different concentrations of Gd(OH)3 and the pH of the coreaction solution were optimized, as shown in Figure 3. Figure 3A exhibits the concentration optimization of the Gd(OH)3 solution (0.1, 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0 mg mL−1). With the increase of the concentration of Gd(OH)3, ECL intensity increased initially, reaching a peak at 1.0 mg mL−1, and then decreased. So, the concentration of Gd(OH)3 solution was set as 1.0 mg mL−1 in subsequent experiments. Another factor worth considering was the pH of the coreaction solution. K2S2O8 solutions were prepared with different pH (pH = 4.40, 5.60, 6.90, 7.40, 8.60, 9.30, and 10.20). Under the condition of GCE modified with Gd(OH)3 (1.0 mg mL−1), the ECL intensity was measured (Figure 3B), which suggested that the overloaded Gd(OH)3 could enhance the blocking of the electron transfer and inhibition of the diffusion of the coreactant into the electrode, which could hinder ECL. ECL intensity increased initially and then decreased and the pH of the coreaction solution increased gradually. The optimal pH value of the K2S2O8 coreaction solution was selected at pH 7.40. This could be attributed to the pH-dependent surface groups of the Gd(OH)3 affecting the ECL reactions. In neutral medium, the Gd(OH)3 surface groups have more activity. That is, K2S2O8 with pH 7.40 was selected for subsequent experiments.

3.3. Mechanism of ECL Aptasensor

According to the results of the experiments, the possible mechanisms of the ECL sensor based on Gd(OH)3 speculated were as follows:
Gd(OH)3 + e → [Gd(OH)3]•−
S2O82− + e → SO42− + SO4•−
[Gd(OH)3]•− + SO4•− → [Gd(OH)3]* + SO42−
[Gd(OH)3]* → Gd(OH)3 + hv
On the basis of the aforementioned mechanism, [Gd(OH)3]* was ECL emission material, which was formed by the interaction of the K2S2O8 coreaction solution. In the process of ECL measurement, Gd(OH)3 obtained electron reduction to [Gd(OH)3]•− and S2O82− also obtained electron reduction to become a strong oxidant (SO4•−) on the surface of GCE (Equations (1) and (2)). Meanwhile, [Gd(OH)3]•− was oxidized by SO4•− into an excited state [Gd(OH)3]* (Equation (3)). During the return of the excited state to the ground state, ECL would be generated (Equation (4)).
Under the optimal experimental conditions, OTA was detected using the ECL aptasensor. As shown in Figure S1 (Supplementary Materials), compared with Gd(OH)3/GCE, the ECL intensity of Apt/Gd(OH)3/GCE (red curve) was decreased slightly, which might be due to the fact that the aptamer hindered the transfer of electrons on the electrode surface to some extent. However, when OTA was incubated, the ECL intensity of OTA/Apt/Gd(OH)3/GCE (black curve) was quenched. The main reason for this phenomenon was that the specific binding of OTA and aptamer covered the surface of Gd(OH)3/GCE, preventing the reaction between the coreaction solution and the Gd(OH)3. The steric hindrance effect produced by OTA might be the main factor that caused the quenching of its ECL intensity.

3.4. Performance of ECL Aptasensor for OTA Detection

Figure 4A shows the ECL intensity recorded after adding OTA solutions with different concentrations (0.01 pg mL−1 to 10 ng mL−1) to the ECL aptasensor based on Apt/Gd(OH)3/GCE. The ECL intensity of Apt/Gd(OH)3/GCE decreased gradually with the addition of increasing OTA concentrations. Figure 4B exhibits the standard curves according to the degree of ECL intensity quenching. When the concentration of the OTA solution ranged from 0.01 pg mL−1 to 10 ng mL−1, the linear equation was ΔI = 1025.6 lgc(OTA) + 15,983 (R2 = 0.998) with a low limit of detection (LOD) of 0.0027 pg mL−1, indicating the effective detection of OTA at low concentrations (ΔI = I0 − I, where I0 represents the ECL intensity of Apt/Gd(OH)3/GCE and I represents the ECL intensity of OTA/Apt/Gd(OH)3/GCE). Moreover, Table S1 summarized some other methods reported to detect OTA previously. Compared with other approaches, the fabricated ECL aptasensor in this study had a lower LOD and a wider detection range, which could meet the growing demand for real sample detection.

3.5. Stability, Reproducibility, and Selectivity of ECL Aptasensor

Stability, reproducibility, and selectivity were important criteria to estimate whether the ECL aptasensor could be applied successfully. Figure 5A shows the ECL behavior of Apt/Gd(OH)3/GCE in the presence of S2O82− as the coreaction. The ECL intensity of Apt/Gd(OH)3/GCE remained high and stable, verifying that Apt/Gd(OH)3/GCE was an excellent electrode material. The same electrode was selected for the stability experiment (Figure 5B). After five days of experimenting, the ECL intensity of the electrode has hardly changed, which could prove Apt/Gd(OH)3/GCE had favorable stability. Under the same experimental conditions, the reproducibility of the ECL aptasensor was also tested using five electrodes, the results are shown in Figure 5C. It can be seen that the ECL intensity of the five selected electrodes changed insignificantly, implying that the ECL aptasensor had excellent reproducibility.
The good selectivity of this ECL aptasensor was a prerequisite for practical application. Firstly, five kinds of solutions (10 ng mL−1 CHL, PG, KAN, NEO, and TC, respectively) were prepared. Next, Apt/Gd(OH)3/GCE was incubated in the above solutions and the ECL intensity was recorded. The results are shown in Figure 5D. ΔI of the target OTA was changed obviously compared to other substances, proving that the ECL aptasensor could recognize OTA accurately, while other substances could not interfere with OTA determination.

3.6. Detection of OTA in Real Samples

Corn and grapes were selected as the real samples to verify the application of the ECL aptasensor. However, OTA was not found in these samples. Then, the recovery experiment, conducted by adding standard samples, was carried out with the addition of three-level OTA, as shown in Table 1. The recovery rate of OTA was 97.76~102.1%, and the relative standard deviation (RSD) was 1.5~3.6%. The accuracy of the aptasensor established in this work was verified by using high-performance liquid chromatography (HPLC) Ultimate, and OTA was not detected in the actual samples. Then, aliquots of a standard solution of OTA were added into the actual samples and the concentration was determined by the proposed method and the HPLC Method (n = 3). The presented statistical studies in Table S2 proved the good precision and accuracy of the proposed method. Thus, the ECL aptasensor was satisfactory in terms of precision and accuracy.

4. Conclusions

In this paper, we demonstrated a promising OTA aptasensor based on the co-immobilization of the aptamer of OTA and Gd(OH)3 nanocrystalline onto the carbon glass electrode (Apt/Gd(OH)3/GCE). The Gd(OH)3 nanocrystalline were synthesized by a glucose-assisted hydrothermal method. Based on highly stable and repeatable ECL emission of Gd(OH)3 and the excellent specificity of the aptamer technique, the present aptasensor exhibited high sensitivity with a low detection limit, wide linear range, good reproducibility, and high stability. Additionally, this aptasensor has a potential application to assay the OTA in the food samples such as corn and grapes. The aptasensor provided a new method for OTA detection and expanded the application of rare earth oxides in food detection.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/bios12121141/s1, Figure S1: ECL intensity versus potential for Gd(OH)3/GCE, Apt/Gd(OH)3/GCE and OTA/Apt/Gd(OH)3/GCE; Table S1 [12,32,33,34]: Comparison of different methods for the detection of OTA; Table S2: Determination of OTA in corn by the proposed method and the HPLC Method (n = 3).

Author Contributions

Conceptualization, C.T., M.W., X.W., and F.L.; methodology, C.T., M.W., Q.H. and X.Z.; validation, C.T., M.W., F.T. and X.Z.; formal analysis, C.T., M.W., Q.H. and F.L.; investigation, C.T., M.W., X.Z. and F.L.; resources, C.T., X.Z. and F.L.; writing—original draft preparation, C.T., M.W. and X.W.; writing—review and editing, C.T., F.L., L.Z. and X.Z.; All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the National Natural Science Foundation of China (grant number 21778047) and Natural Science Foundation of Shandong Province in China (ZR2021MB024).

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

Not applicable.

Conflicts of Interest

There are no conflict to declare.

References

  1. Gallo, A.; Ferrara, M.; Perrone, G. Recent advances on the molecular aspects of ochratoxin A biosynthesis. Curr. Opin. Food Sci. 2017, 17, 49–56. [Google Scholar] [CrossRef]
  2. Kumar, P.; Mahato, D.K.; Sharma, B.; Borah, R.; Haque, S.; Mahmud, M.M.C.; Shah, A.K.; Rawal, D.; Bora, H.; Bui, S. Ochratoxins in food and feed: Occurrence and its impact on human health and management strategies. Toxicon 2020, 187, 151–162. [Google Scholar] [CrossRef] [PubMed]
  3. O’Brien, E.; Dietrich, D.R. Ochratoxin A: The continuing enigma. Crit. Rev. Toxicol. 2005, 35, 33–60. [Google Scholar] [CrossRef] [PubMed]
  4. El Khoury, A.; Atoui, A. Ochratoxin A: General overview and actual molecular status. Toxins 2010, 2, 461–493. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  5. Pfohl-Leszkowicz, A.; Manderville, R.A. Ochratoxin A: An overview on toxicity and carcinogenicity in animals and humans. Mol. Nutr. Food Res. 2007, 51, 61–99. [Google Scholar] [CrossRef]
  6. Afsah-Hejri, L.; Jinap, S.; Mirhosseini, H. Ochratoxin A quantification: Newly developed HPLC conditions. Food Control 2012, 23, 113–119. [Google Scholar] [CrossRef]
  7. Soleas, G.J.; Yan, J.; Goldberg, D.M. Assay of Ochratoxin A in wine and beer by high pressure liquid chromatography photodiode array and gas chromatography mass selective detection. J. Agric. Food Chem. 2001, 49, 2733–2740. [Google Scholar] [CrossRef]
  8. Flajs, D.; Domijan, A.M.; Ivić, D.; Cvjetkovic´, B.; Peraica, M. ELISA and HPLC analysis of ochratoxin A in red wines of Croatia. Food Control 2009, 20, 590–592. [Google Scholar] [CrossRef]
  9. Yu, F.Y.; Chi, T.F.; Liu, B.H.; Su, C.C. Development of a sensitive enzyme-linked immunosorbent assay for the determination of ochratoxin A. J. Agric. Food Chem. 2005, 53, 6947–6953. [Google Scholar] [CrossRef]
  10. Wang, C.K.; Tan, R.; Chen, D. Fluorescence method for quickly detecting ochratoxin A in flour and beer using nitrogen doped carbon dots and silver nanoparticles. Talanta 2018, 182, 363–370. [Google Scholar] [CrossRef]
  11. Todescato, F.; Antognoli, A.; Meneghello, A.; Cretaio, E.; Signorini, R.; Bozio, R. Sensitive detection of Ochratoxin A in food and drinks using metal-enhanced fluorescence. Biosens. Bioelectron. 2014, 57, 125–132. [Google Scholar] [CrossRef] [PubMed]
  12. Feng, J.H.; Qian, Y.R.; Cheng, Q.; Ma, Y.M.; Wu, D.; Ma, H.M.; Ren, X.; Wang, X.Y.; Wei, Q. A signal amplification of pDNA@Ag2S based photoelectrochemical competitive sensor for the sensitive detection of OTA in microfluidic devices. Biosens. Bioelectron. 2020, 168, 112503. [Google Scholar] [CrossRef] [PubMed]
  13. Jia, M.X.; Liao, X.F.; Fang, L.; Jia, B.Y.; Liu, M.; Li, D.H.; Zhou, L.D.; Kong, W.J. Recent advances on immunosensors for mycotoxins in foods and other commodities. TrAC Trend. Anal. Chem. 2021, 136, 116193. [Google Scholar] [CrossRef]
  14. Li, X.Y.; Falcone, N.; Hossain, M.N.; Kraatz, H.B.; Chen, X.J.; Huang, H. Development of a novel label-free impedimetric electrochemical sensor based on hydrogel/chitosan for the detection of ochratoxin A. Talanta 2021, 226, 122183. [Google Scholar] [CrossRef] [PubMed]
  15. Shi, Z.X.; Li, G.K.; Hu, Y.F. Progress on the application of electrochemiluminescence biosensor based on nanomaterials. Chin. Chem. Lett. 2019, 9, 1600–1606. [Google Scholar] [CrossRef]
  16. Sun, C.N.; Liao, X.F.; Huang, P.X.; Shan, G.Z.; Ma, X.; Fu, L.Z.; Zhou, L.D.; Kong, W.J. A self-assembled electrochemical immunosensor for ultra-sensitive detection of ochratoxin A in medicinal and edible malt. Food Chem. 2020, 315, 126289. [Google Scholar] [CrossRef]
  17. Yang, E.R.; Zhang, Y.J.; Shen, Y.F. Quantum dots for electrochemiluminescence bioanalysis A review. Anal. Chim. Acta. 2022, 1209, 339140. [Google Scholar] [CrossRef]
  18. Gao, W.Y.; Saqib, M.; Qi, L.M.; Zhang, W.; Xu, G.B. Recent advances in electrochemiluminescence devices for point-of-care testing. Curr. Opin. Electrochem. 2017, 3, 4–10. [Google Scholar] [CrossRef]
  19. Hyun, J.L.; Eun, H.L.; Sang, D.L.; Yeomin, Y.; Ahjeong, S. Quantitative screening for endocrine-disrupting bisphenol A in consumer and household products using NanoAptamer assay. Chemosphere 2018, 211, 72–80. [Google Scholar]
  20. Maugi, R.; Gamble, B.; Bunka, D.; Platt, M. A simple displacement aptamer assay on resistive pulse sensor for small molecule detection. Talanta 2021, 225, 122068. [Google Scholar] [CrossRef]
  21. Ni, S.J.; Zhuo, Z.J.; Pan, Y.F.; Yu, Y.Y.; Li, F.F.; Liu, J.; Wang, L.Y.; Wu, X.Q.; Li, D.J.; Wan, Y.Y.; et al. Recent progress in aptamer discoveries and modifications for therapeutic applications. ACS. Appl. Mater. Inter. 2021, 13, 9500–9519. [Google Scholar] [CrossRef] [PubMed]
  22. Ștefan, G.; Hosu, O.; Wael, K.D.; Lobo-Castanon, M.J.; Cristea, C. Aptamers in biomedicine: Selection strategies and recent advances. Electrochim. Acta 2021, 376, 137994. [Google Scholar] [CrossRef]
  23. Wang, X.; Sun, X.M.; Yu, D.P.; Zou, B.S.; Li, Y.D. Rare earth compound nanotubes. Adv. Mater. 2003, 15, 1442–1445. [Google Scholar] [CrossRef]
  24. Wang, X.; Li, Y. Rare-earth-compound nanowires, nanotubes, and fullerene-like nanoparticles: Synthesis, characterization, and properties. Chem. Eur. J. 2003, 9, 5627–5635. [Google Scholar] [CrossRef]
  25. Cheraghali, R.; Aghazadeh, M. A simple and facile electrochemical route to synthesis of metal hydroxides and oxides ultrafine nanoparticles (M = La, Gd, Ni and Co). Anal. Bioanal. Chem. 2016, 8, 64–77. [Google Scholar]
  26. Li, G.G.; Liang, Y.J.; Zhang, M.F.; Yu, D.Y. Size-tunable synthesis and luminescent properties of Gd(OH)3:Eu3+ and Gd2O3:Eu3+ hexagonal nano-/microprisms. CrystEngComm 2014, 16, 6670–6679. [Google Scholar] [CrossRef]
  27. Yang, Y.; Sun, Y.; Liu, Y.; Peng, J.J.; Wu, Y.Q.; Zhang, Y.J.; Feng, W.; Li, F.Y. Long-term in vivo biodistribution and toxicity of Gd(OH)3 nanorods. Biomaterials 2013, 34, 508–515. [Google Scholar] [CrossRef]
  28. Xing, G.J.; Guo, Q.Y.; Liu, Q.J.; Li, Y.L.; Wang, Y.; Wu, Z.L.; Wu, G.M. Highly uniform Gd(OH)3 and Gd2O3:Eu3+ hexagram-like microcrystals: Glucose-assisted hydrothermal synthesis, growth mechanism and luminescence property. Ceram. Int. 2014, 40, 6569–6577. [Google Scholar] [CrossRef]
  29. Almeida, M.S.; Santos, M.A.B.; Goncalves, R.D.; Santos, M.R.D.; Marques, A.P.D.; Longo, E.; La Porta, F.D.; Pinatti, I.M.; Silva, M.D.P.; Godinho, M.J. Novel Gd(OH)3, GdOOH and Gd2O3 nanorods: Microwave-assisted hydrothermal synthesis and optical properties. Mat. Res. 2016, 19, 1155–1161. [Google Scholar] [CrossRef] [Green Version]
  30. Mu, Q.; Wang, Y. A simple method to prepare Ln(OH)3 (Ln¼La, Sm, Tb, Eu, and Gd) nanorods using CTAB micelle solution and their room temperature photoluminescence properties. J. Alloys Compd. 2011, 509, 2060–2065. [Google Scholar] [CrossRef]
  31. Kang, J.G.; Jung, Y.; Min, B.K.; Sohn, Y. Full characterization of Eu(OH)3 and Eu2O3 nanorods. Appl. Surf. Sci. 2014, 314, 158–165. [Google Scholar] [CrossRef]
  32. Zhang, J.; Xia, Y.K.; Chen, M.; Wu, D.Z.; Cai, S.X.; Liu, M.M.; He, W.H.; Chen, J.H. A fluorescent aptasensor based on DNA-scaffolded silver nanoclusters coupling with Zn(II)-ion signal-enhancement for simultaneous detection of OTA and AFB1. Sensor. Actuat. B-Chem. 2016, 235, 79–85. [Google Scholar] [CrossRef]
  33. Barthelmebs, L.; Hayat, A.; Limiadi, A.W.; Marty, J.L.; Noguer, T. Electrochemical DNA aptamer-based biosensor for OTA detection, using superparamagnetic nanoparticles. Sensor. Actuat. B-Chem. 2021, 156, 932–937. [Google Scholar] [CrossRef]
  34. Zhu, C.X.; Liu, D.; Li, Y.Y.; Ma, S.; Wang, M.; You, T.Y. Hairpin DNA assisted dual-ratiometric electrochemical aptasensor with high reliability and anti-interference ability for simultaneous detection of aflatoxin B1 and ochratoxin A. Biosens. Bioelectron. 2021, 175, 112654. [Google Scholar] [CrossRef] [PubMed]
Scheme 1. Mechanism of the ECL aptasensor based on Gd(OH)3 nanocrystals.
Scheme 1. Mechanism of the ECL aptasensor based on Gd(OH)3 nanocrystals.
Biosensors 12 01141 sch001
Figure 1. (A) SEM image and (B) EDS spectrum of Gd(OH)3 nanocrystals.
Figure 1. (A) SEM image and (B) EDS spectrum of Gd(OH)3 nanocrystals.
Biosensors 12 01141 g001
Figure 2. (A) XRD spectrum; (B) FT−IR spectrum; (C) UV−vis absorption spectrum; and (D) Fluorescence spectrum of Gd(OH)3 nanocrystals.
Figure 2. (A) XRD spectrum; (B) FT−IR spectrum; (C) UV−vis absorption spectrum; and (D) Fluorescence spectrum of Gd(OH)3 nanocrystals.
Biosensors 12 01141 g002
Figure 3. (A) Optimization of concentration of Gd(OH)3; (B) Optimization of pH of K2S2O8 coreaction solution.
Figure 3. (A) Optimization of concentration of Gd(OH)3; (B) Optimization of pH of K2S2O8 coreaction solution.
Biosensors 12 01141 g003
Figure 4. (A) ECL response of ECL aptasensor at different OTA concentrations and (B) linear relationship of ECL aptasensor to OTA.
Figure 4. (A) ECL response of ECL aptasensor at different OTA concentrations and (B) linear relationship of ECL aptasensor to OTA.
Biosensors 12 01141 g004
Figure 5. (A) The relationship between ECL intensity and time of continuous scanning for 20 cyclic. (B) Stability of the ECL aptasensor within 5 consecutive days. (C) Reproducibility of the ECL aptasensor with 5 different electrodes. (D) Selectivity of the ECL aptasensor for OTA and its analogs at the same concentration.
Figure 5. (A) The relationship between ECL intensity and time of continuous scanning for 20 cyclic. (B) Stability of the ECL aptasensor within 5 consecutive days. (C) Reproducibility of the ECL aptasensor with 5 different electrodes. (D) Selectivity of the ECL aptasensor for OTA and its analogs at the same concentration.
Biosensors 12 01141 g005
Table 1. OTA recovery tests in real samples by the ECL aptasensor.
Table 1. OTA recovery tests in real samples by the ECL aptasensor.
SamplesAdded (ng/mL)Found (ng/mL)Recovery (%)RSD (%)
1010.2102.11.8
Grape1.01.01101.42.1
0.10.09999.521.7
1010.1100.73.6
Corn1.00.9898.562.8
0.10.09797.761.5
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Tian, C.; Wei, M.; Wang, X.; Hua, Q.; Tang, F.; Zhao, L.; Zhuang, X.; Luan, F. Electrochemiluminescence Aptasensor Based on Gd(OH)3 Nanocrystalline for Ochratoxin A Detection in Food Samples. Biosensors 2022, 12, 1141. https://doi.org/10.3390/bios12121141

AMA Style

Tian C, Wei M, Wang X, Hua Q, Tang F, Zhao L, Zhuang X, Luan F. Electrochemiluminescence Aptasensor Based on Gd(OH)3 Nanocrystalline for Ochratoxin A Detection in Food Samples. Biosensors. 2022; 12(12):1141. https://doi.org/10.3390/bios12121141

Chicago/Turabian Style

Tian, Chunyuan, Minggang Wei, Xiaobin Wang, Qing Hua, Feiyan Tang, Lijun Zhao, Xuming Zhuang, and Feng Luan. 2022. "Electrochemiluminescence Aptasensor Based on Gd(OH)3 Nanocrystalline for Ochratoxin A Detection in Food Samples" Biosensors 12, no. 12: 1141. https://doi.org/10.3390/bios12121141

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop