Article

A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection

1
Energy and Environmental Innovation Group, Faculty of Engineering, Malvinas Institute, National University of La Plata, La Plata B1900, Argentina
2
National Scientific and Technical Research Council (CONICET), Buenos Aires C1425FQB, Argentina
3
Faculty of Engineering, National University of Patagonia, San Juan Bosco, Comodoro Rivadavia U9000, Argentina
*
Author to whom correspondence should be addressed.
Appl. Sci. 2023, 13(7), 4586; https://doi.org/10.3390/app13074586
Submission received: 26 February 2023 / Revised: 25 March 2023 / Accepted: 30 March 2023 / Published: 4 April 2023
(This article belongs to the Special Issue Corrosion Inhibitors and Protective Coatings)

Abstract

:

Featured Application

Specific applications for the oil and gas industry. Testing of corrosion inhibitors to select the one with the best performance simulating field conditions.

Abstract

Corrosion inhibitors are evaluated in the oil industry with electrochemical tests of resistance to linear polarization with rotating cylinders following ASTM G170 and NACE 3T199 standards. With these tests, we can determine the corrosion rate (CR) and efficiency of corrosion inhibitors. In this work, a corrosion test protocol used by hydrocarbon-producing companies for the testing of corrosion inhibitors was used. This protocol consists of a 1045 carbon steel working electrode in a NACE solution composed of 9.62% NaCl, 0.45% CaCl2, 0.19% MgCl2, and 89.74% H2O, at a temperature of 65 °C and saturated with CO2. Each inhibitor tested was subjected to a series of 6000-4000-2000-4000-6000 rpm tests using rotating cylinder electrodes (RCEs). These electrochemical studies were carried out with the rotating cylinder to evaluate the ability of the inhibitor to prevent the corrosion of carbon steel in the presence of a centrifugal force. In our opinion, this test does not provide corrosion engineers with enough information to be used as a predictive tool, since what is obtained is the CR in a very short testing time. This document proposes the use of two more appropriate test methodologies, the rotating cylinder electrode (RCE) and the flow loop (FL), to evaluate the performance of the corrosion inhibitor. For the FL, the selected flow rate was 1.2 m/s, the same rate that fluids have in oil company pipelines installed in Neuquén, Argentina. Firstly, according to the company’s protocol, inhibitors are required to have an efficiency greater than or equal to 90% in RCE tests; therefore, inhibitors that meet these requirements were tested in the FL test. Unlike the RCE test, the FL test represents the experimental conditions of the laboratory that are closest to reality, for the evaluation of the performance of the inhibitors used in the pipelines of the oil and gas industry. FL tests have several problems involving corrosion, erosion, abrasion, biphasic fluids, the time it takes for the inhibitor to become effective, and the duration of its effectiveness.

1. Introduction

In the oil and gas industry, the severity of CO2 corrosion (or sweet corrosion) of pipelines is affected by crossed reactions and the interaction of different factors, including environmental, metallurgical, and physical parameters. The main environmental variables that affect CO2 corrosion are temperature, pressure, flow condition, type of material, and salt concentration. Moreover, impurities in the surrounding flow may significantly impact the corrosion of carbon steel [1,2]. The main concern of CO2 corrosion is that it may lead to equipment failure, especially in the tubing/casing of the production and injection wells, as well as pipelines, thus interrupting the oil/gas production [3,4]. Even the slightest change in one of these parameters can considerably impact the corrosion rate, given the property changes in the thin layer of corrosion products accumulated on the surface of the steel [5,6]. When corrosion products are not on the surface of the steel, high rates of corrosion of several millimeters per year can take place. Corrosion rates can be substantially reduced under the conditions in which iron carbonate (FeCO3) can precipitate on the steel surface and create a dense and protective corrosion product film. This occurs more easily at high temperatures or high pH in the water phase [6,7]. High temperature increases the rate of reaction, which produces a protective corrosion product layer, thus reducing corrosion rates, while high pH reduces the descaling of the corrosion product layer, which yields a low corrosion rate [3,8]. Dry CO2 is not corrosive under the temperatures found in oil and gas production. It must dissolve in a liquid phase to cause an electrochemical reaction between the steel and the liquid phase in contact. CO2 is soluble in water and brine. However, it should be pointed out that it has a solubility rate similar to that of hydrocarbon, both in the gaseous and liquid phases. Thus, for a mixed-phase system, the presence of the hydrocarbon phase may provide CO2 deposition for the partition in the liquid phase. CO2 is usually found in the produced fluids. Basically, CO2 corrosion is an electrochemical process consisting of several steps that occur between the corrosive species that result from CO2 dissolution and the soluble phases of steel. The corrosion of tubing in a CO2 environment has been widely studied under various conditions to understand its corrosion mechanism and protective methods [9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27]. Using chemical treatment to prevent iron and steel from CO2 corrosion is one of the most cost-effective ways [28,29,30]. Organic molecules are one of the most popular, efficient, and practical corrosion inhibitors, and most studies demonstrate that organic compounds, preferentially those containing nitrogen (N), sulfur (S), and oxygen (O), have high inhibitory efficiency [31,32,33,34,35].
D. Harrop et al. [36] specifically compared essays on corrosion inhibitors carried out in a flow loop with a rotating cylinder. The obtained corrosion rates revealed significant differences depending on time, given that they were tested at 1 bar of CO2, 50 °C, pH 5.6, and 20 Pa shear stress. These differences exist because of the different shear stress generated in FL and RCE tests on the surface of each tested sample. Shear stress equations for both FL and RCE tests are shown below [37,38,39,40,41].
RCE σc = 0.079 Re−0.3dv2
FL σp = 0.039 Re−0.25dv2
where σc = turbulent shear stress (cylinder), Re = Reynolds number, d = fluid density, σp = turbulent shear stress (pipe), and v = fluid velocity.
Nowadays, the efficiency of corrosion inhibitors under certain flow conditions can be assessed using RCEs in accordance with ASTM [42,43,44].
Corrosion engineers require a predictive tool that is not over-conservative and that will not compromise safety. When designing a facility or pipeline, requirements such as service life, corrosion allowance, and the efficacy of inhibitor treatment dictate the quantification of the corrosion rate. For this reason, the aim of this work is the implementation of a methodology for the evaluation of corrosion inhibitors combining RCE and FL methods, to select the parameters for the inhibitor’s best performance.

2. Experimental Development

Corrosion inhibitors called Inhibitor 1, Inhibitor 2, Inhibitor 3, and Inhibitor 4 of an oil company from Argentina were tested at a 150 ppm concentration. A NACE solution was used, as was requested by the company according to its protocol, composed of the following salts: 9.62% NaCl; 0.45% CaCl2; 0.19% MgCl2; and 89.74% H2O. All reagents are of analytical grade, and distilled water was used for its dissolution. For all tests, the working temperature was 65 °C, saturated with CO2 99.995%. At 25 °C, the CO2-saturated NACE solution’s pH was 5.27.

2.1. Electrochemical Tests of Resistance to Linear Polarization with Rotating Cylinder

Tests were carried out at a laboratory scale to assess the efficiency of inhibitors on the corrosion rate, using linear polarization resistance (LPR) in dynamic conditions in an electrochemical cell.
In the linear polarization tests, the Metrohm AUTOLAB potentiostat/galvanostat was used, along with its corresponding software, NOVA 2.1.
The electrochemical cell used has three electrodes: the reference electrode, which was AgCl/Ag in a KCl 3M solution brought to closer contact with the working electrode using a Luggin capillary, thus lowering the ohm resistance between the reference electrode and the working electrode; the working electrode, a 1045 carbon steel cylinder with a 2.47 cm2 exposed area; finally, a graphite counter-electrode was used. All electrodes were submerged in the NACE solution.
To carry out the tests in dynamic conditions, a rotating disk electrode was used, consisting of a rotating rod. The rotation working speed was, in accordance with the oil company’s protocol, a series of 6000-4000-2000-4000-6000 rpm for each studied inhibitor. The working electrode rotated in the core of the NACE solution at a working temperature of 65 °C with CO2 bubbling.
To assess the efficiency of the inhibitors (ASTM G185-06), the instantaneous corrosion rate was measured using the LPR method at the aforementioned speeds, with constant CO2 bubbling at 65 °C. After one-hour gas saturation, the open-loop potential was measured for one hour, with and without a corrosion inhibitor, followed by a polarization resistance test between −20 mV and +20 mV of the open-loop potential.
To calculate the efficiency, Equation (3) is used, where CR is the corrosion rate:
E f f i c i e n c y = C R   w i t h o u t   i n h i b i t o r - C R   w i t h   i n h i b i t o r C R   w i t h o u t   i n h i b i t o r 100

2.2. Electrochemical Tests in Corrosion Loop

For the dynamic testing, FL was used (Figure 1A). It has a storage capacity of 18 liters. In the loop pipelines, two 1045 carbon steel corrosion coupons were placed, labeled as C1 (the upper area of the pipeline) with a medium-exposed area of 56.5488 mm2 and as C2 (lower area of the pipeline) with a medium-exposed area of 64.8168 mm2. To avoid crevice corrosion formation in the coupons, they were carefully sealed with neutral cure silicone, as shown in Figure 1B. Before mounting the coupons, they were glass-polished and weighed with an AUW 220D weighing scale (e = 1 mg; d = 0.1 mg/0.01 mg).

3. Results and Discussion

Table 1 and Figure 2 show the test results for each assessed inhibitor. The target, a tested graduated cylinder without an inhibitor, which was used to obtain the inhibitors’ efficiency, had a corrosion rate (CR) of 19.21 mm/year with a corrosion potential (Ec) of −683 mV and a corrosion current (CC) of 2.5 mA.
Out of the four inhibitors that were tested at a 150 ppm concentration, Inhibitor 1 was the one that had an efficiency equal to or greater than 90%. The rest of the corrosion inhibitors did not reach a 90% efficiency in any of the tests with the rotating cylinder. The oil company considers that an inhibitor passes the test if its corrosion efficiency is equal to or greater than 90%.
Fractographies at 20× of the carbon steels tested with the corrosion inhibitors are shown in Figure 3. They were assessed considering the criterion of Smith et al. [45], which is shown in Table 2, as exclusively requested by the oil company.
Inhibitor 1 exhibited general corrosion, but no major pits were observed; thus, it is considered to be Rank 2, according to Smith, whereas in the rest of the tested inhibitors, the surface of the carbon steel revealed abundant pitting.
Tests with the NACE solution (Table 3 and Figure 4 and Figure 5) were carried out at a 65 °C working temperature, saturated with CO2 99.995%, at a flow speed of 1.2 m/s equal to an angular velocity of 1100 rpm [40]. The chosen flow velocity was the same as that of the pipeline in the company’s oil field. A Cosasco Aquamate Corrater Instrument was used to measure both the electrochemical LPR and the weight-loss corrosion rate. An electrochemical current noise (ECN) form, known as imbalance (unbalance or pitting tendency) was also monitored among the electrodes. This is a useful qualitative instability signal on the surface of the material that coincides with pitting or localized corrosion. Figure 4 shows the corrosion rate and the imbalance rate (pitting tendency), both depending on time for each tested corrosion inhibitor. Inhibitors were added to the solution only once, with an individual concentration of 150 ppm, equal to the concentration used for the RCE tests.
Electrochemical studies with rotating cylinders assess inhibitors’ capacity to prevent carbon steel corrosion under a centrifugal force. They are tools that are commonly used to assess corrosion inhibitors’ performance in oil fields [46,47,48,49,50,51].
As shown in Table 1 and Figure 2, at a constant inhibitor concentration (150 ppm) and under the aforementioned work conditions, the performance of the corrosion inhibitor (inhibition efficiency) depends on the working electrode rotation speed (shear stress). In most of the cases we studied, the higher the rpm, the higher the corrosion current (CC); that is, the higher the general corrosion rate, the lower the inhibitor’s efficiency [52]. María Elena Olvera-Martínez et al. [52] obtained similar results when working with RCE at rates of 0, 100, 1000, 2000, 3000, 4000, 5000, and 6000 rpm, and using API 5L X52 steel cylindric samples as working electrodes in 5% NaCl solutions, at 60 °C, with saturated CO2, and at different concentrations of the used inhibitor.
As can be seen in Figure 3, in this work, Inhibitor 1 was the one with an efficiency of over 90%, thus having a Rank 2 general corrosion, according to Smith’s criterion.
We cannot speak of the efficiency of an inhibitor if there is localized corrosion. Efficiency against corrosion is defined as efficiency against general corrosion. If there is a localized attack, it is not possible to have efficiency values, given that there is inefficiency; that is, an inhibitor is not efficient if the material undergoes a localized attack (pitting, stress corrosion cracking, corrosion fatigue, etc.). This information is crucial for the corrosion engineer, given that an inhibitor that produces pitting endangers the security of the oil field’s facilities. On the other hand, the fluid flow regime is one of the parameters that have a great effect on the surface rate. The type of flow regime affects the thickness and velocity of the water layer flowing up the tubing, and it defines the shear stress and mass transfer at the steel surface [53,54,55].
Flow loop tests are an important complement because they represent the closest experimental laboratory condition to assess the performance of those inhibitors that are used in the oil and gas industry. The selected flow rate, 1.2 m/s, is the same as that of the pipeline fluids of oil companies in Neuquén, Argentina. FL tests evince problems that involve corrosion, erosion, abrasion, two-phase fluids, the time the inhibitor takes to coat the graduated cylinders, the period during which the inhibitor works, etc. Table 3 shows the differences between the CR relative to the weight loss of corrosion coupons C1 and C2. The CR values found in corrosion coupon C1 were higher than those found in coupon C2. This is because C1 was on the upper part of the pipeline (Figure 3), where it came into contact with two-phase fluids (CO2 gas + NACE solution), whereas corrosion coupon C2 was on the lower part of the pipeline, where it was in contact with the NACE solution + dissolved CO2. Table 3 shows the CR relative to the mean LPR of each inhibitor obtained with the Aquamate Corrater Instrument. These were within the CR value range obtained for each weight-loss coupon.
When assessing corrosion inhibitors, O. Gómez et al. [56] applied NACE G 170 in an FL test using a liquid solution containing pressurized CO2. With the FL equipment they used, they determined the instantaneous corrosion rate with RLP and Tafel polarization curve (TPC) measurements, as well as the efficiency against the corrosion of the inhibitors, which was tested statically and dynamically at a 0.5 m/s flow rate.
We can obtain more information on this study by looking at Figure 6 (analysis of the first graphic of Figure 4), which corresponds to Inhibitor 1, where we can see different zones in which the inhibitor works. Zone 1 indicates how long the inhibitor takes to coat the graduated cylinder. The steeper the slope, the greater the coating speed and, thus, the better the inhibitor’s performance. Zone 2 shows the moment in which the inhibitor starts to work; the corrosion rate was 0.94 mm/year with an imbalance rate of 0.22, which is a high corrosion rate according to Fontana et al. [57] with no pitting. Zone 3 indicates the moment in which the inhibitor stops working, and in this zone, the corrosion values increased sharply. It is important to point out that the corrosion inhibitor was added only once for each test.
Figure 4 corresponding to Inhibitors 2, 3, and 4, show that the zone differentiation was not as clear as it was for Inhibitor 1. For these cases, both the corrosion rates and the imbalance rates remained high; in addition, in the worst-case scenario, slopes are positive, as is the case for Inhibitors 3 and 4 (Figure 5), showing the presence of pitting. In the studies carried out with the rotating cylinder for Inhibitors 2, 3, and 4, efficiency was under 90% with the presence of pitting.
Observing the performance of Inhibitor 1 in Figure 4, it can be stated that the corrosion rate was 0.94 mm/year, when the inhibitor was working, whereas the data obtained in Table 3 indicate the average of all the tests, that is, the values obtained with and without the inhibitor working.
Wei Li et al. [41] precisely measured the wall shear stress under controlled laboratory conditions, under a single-phase tap-water flow in a wide range of gas–liquid flow regimes (stratified flow, slug flow, and annular mist flow). The highest wall shear stress measured was of the order of 102 Pa in an atmospheric pressure flow system. Atomic force microscopy measurements indicated that the forces of the order of 107 Pa would be required to remove an iron carbonate precipitate from a mild steel surface. They concluded that this is an important finding indicating that the wall shear stress typically seen in multiphase flow lines is not sufficient to damage FeCO3 layers, which could lead to accelerated and localized corrosion. Although Wei Li et al., obtained important results, these are purely mechanical, and neither electrochemical phenomena nor the physical mechanisms of the solid (such as the doping of FeCO3 crystals with Na+, Ca2+, ions, etc.) were considered between the protective layer and the medium (reservoir water containing high salt concentration). The studies of D. Harrop et al. [36] show a comparison of the corrosion rate for FL and RCE tests obtained under the same conditions of 1 bar CO2, 50 °C, 20 Pa shear stress in the Forties formation water, with pH 5.6. Harrop concluded that this comparison was not good because the mass transfer was lower for the RCE test than for the FL under the same shear stress [37,38,39,40,41]. Therefore, in accordance with Harrop’s perspective, we should not compare the results obtained herein for FL and RCE tests. However, the difference lies in the fact that both methods complement each other, given that the fluid rate conditions, and not those of the shear stress, were maintained for both methods. After using RCE to determine which inhibitor had a general corrosion inhibition capacity greater than 90%, under the same operating conditions, the properties of FL were reassessed under conditions more similar to what actually occurs in the field, obtaining the moment in which the protective layer was formed, the moment in which the inhibitor began to be effective, and the moment in which it started to lose its anti-corrosion capacity (Figure 6). If we combine the values of both methods, similar to how they were combined in this work, corrosion engineers are provided with more tools for corrosion control in oil fields.

4. Conclusions

The corrosion rates obtained using the RCE method are carried out in a very short time and are not very representative of what happens in oil and gas pipelines. By contrast, in FL tests, the times are much longer, giving more information about the behavior of the corrosion inhibitor. In flow loop tests, in addition to obtaining the corrosion rates, it is possible to discern between corrosion by wet gas and soluble gas, abrasion effects, the time the inhibitor begins to inhibit, as well as the time that the inhibitor works.
Although Inhibitor 1 offers better performance against corrosion compared with the other inhibitors tested, the protection against corrosion that it presents with the concentration used (150 ppm) is regular according to Fontana. A higher concentration of the inhibitor (e.g., 250 ppm) would substantially improve its corrosion-inhibitory properties.

Author Contributions

Conceptualization, G.L.B., V.A. and C.S.; Methodology, G.L.B., V.A. and C.S.; Investigation, V.A. and C.S.; Writing—review & editing, G.L.B.; Supervision, G.L.B. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by TECTIONS SOUTH S.A.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Ruhal, A.; Kranzmann, A. Investigation of pipeline corrosion in pressurized CO2 containing impurities. Energy Procedia 2013, 37, 3131–3136. [Google Scholar] [CrossRef] [Green Version]
  2. Mobbassar, H. Corrosion of General Oil-field Grade Steel in CO2 Environment-an Update in the Light of Current Understanding. Int. J. Electrochem. Sci. 2017, 12, 4277–4290. [Google Scholar]
  3. Yaro, A.S.; Abdul-Khalik, K.R.; Khadom, A.A. Effect of CO2 corrosion behavior of mild steel in oilfield produced water. J. Loss Prev. Process Ind. 2015, 38, 24–38. [Google Scholar] [CrossRef]
  4. Wei, L.; Chen, Z.; Guo, X. Inhibition Behavior of an Imidazoline Inhibitor for Carbon Steel in a Supercritical CO2/H2O System. J. Electrochem. Soc. 2017, 164, 602–609. [Google Scholar] [CrossRef]
  5. Nyborg, R. CO2 corrosion models for oil and gas production systems. In Proceedings of the Corrosion 2010, San Antonio, TX, USA, 14–18 March 2010; pp. 1–20. [Google Scholar]
  6. Iyer, J.; Lackey, G.; Edvardsen, L.; Bean, A.; Carroll, S.A.; Huerta, N.; Smith, M.M.; Torsæter, M.; Dilmore, R.M.; Cerasi, P. A Review of Well Integrity Based on Field Experience at Carbon Utilization and Storage Sites. Int. J. Greenh. Gas Control 2022, 113, 103533. [Google Scholar] [CrossRef]
  7. Koteeswaran, M. Corrosion by CO2 and H2S in Oil Pipelines; Universidad de Stavenger: Stavanger, Norway, 2010; p. 79. [Google Scholar]
  8. Tamalmani, K.; Husin, H. Review on Corrosion Inhibitors for Oil and Gas Corrosion Issues. Appl. Sci. 2020, 10, 3389. [Google Scholar] [CrossRef]
  9. Kahyarian, A.; Singer, M.; Nesic, S. Modeling of uniform CO2 corrosion of mild steel in gas transportation systems: A review. J. Nat. Gas Sci. Eng. 2016, 29, 530–549. [Google Scholar] [CrossRef]
  10. Liao, K.; Qin, M.; Yang, N.; He, G.; Zhao, S.; Zhang, S. Corrosion main control factors and corrosion degree prediction charts in H2S and CO2 coexisting associated gas pipelines. Mater. Chem. Phys. 2022, 292, 126838. [Google Scholar] [CrossRef]
  11. Zheng, Y.; Ning, J.; Brown, B.; Nesic, S. Electrochemical model of mild steel corrosion in a mixed H2S/CO2 aqueous environment in the absence of protective corrosion product layers. Corrosion 2015, 71, 316–325. [Google Scholar] [CrossRef]
  12. Huang, X.; Zhou, L.; Li, Y.; Du, Z.; Zhu, Q.; Han, Z. The synergistic effect of temperature, H2S/CO2 partial pressure and stress toward corrosion of X80 pipeline steel. Eng. Fail. Anal. 2023, 146, 107079. [Google Scholar] [CrossRef]
  13. Nesic, S. Effects of multiphase flow on internal CO2 corrosion of mild steel pipelines. Energy Fuels 2012, 26, 4098–4111. [Google Scholar] [CrossRef]
  14. Onyeachu, I.B.; Njoku, D.I.; Nwanonenyi, S.C.; Ahanotu, C.C.; Etiowo, K.M. Investigation into the adsorption and inhibition properties of sodium octanoate against CO2 corrosion of C1018 carbon steel under static and hydrodynamic conditions. Sci. Afr. 2023, 20, e01603. [Google Scholar] [CrossRef]
  15. Li, W.; Pots, B.; Brown, B.; Kee, K.E.; Nesic, S. A direct measurement of wall shear stress in multiphase flow-Is it an important parameter in CO2 corrosion of carbon steel pipelines. Corros. Sci. 2016, 110, 35–45. [Google Scholar] [CrossRef]
  16. Gong, Q.; Wu, H.; Yang, F.; Tang, Z. Corrosion of pipeline steel weld metals containing alloying elements in CO2/H2S environment. J. Nat. Gas Sci. Eng. 2023, 109, 104846. [Google Scholar] [CrossRef]
  17. Fang, H.; Brown, B.; Nesic, S. Sodium chloride concentration effects on general CO2 corrosion mechanisms. Corrosion 2013, 69, 297–302. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  18. Wang, Z.; Zhao, Y.; Liu, M.; Shen, H.; Fang, Q.; Yao, J. Investigation of the effects of small flow rate and particle impact on high temperature CO2 corrosion of N80 steel. Corros. Sci. 2022, 209, 110735. [Google Scholar] [CrossRef]
  19. Elgaddafi, R.; Naidu, A.; Ahmed, R.; Shah, S.; Hassani, S.; Osisanya, S.O.; Saasen, A. Modeling and experimental study of CO2 corrosion on carbon steel at elevated pressure and temperature. J. Nat. Gas Sci. Eng. 2015, 27, 1620–1629. [Google Scholar] [CrossRef]
  20. Mansoori, H.; Young, D.; Brown, B.; Singer, M. Influence of calcium and magnesium ions on CO2 corrosion of carbon steel in oil and gas production systems–A review. J. Nat. Gas Sci. Eng. 2018, 59, 287–296. [Google Scholar] [CrossRef]
  21. Kakaei, M.N.; Neshati, J.; Hoseiny, H.; Poursaberi, T. A non-equilibrium approach to study the corrosion behavior of carbon steel in diethanolamine-H2O-CO2 systems. Corros. Sci. 2016, 104, 132–143. [Google Scholar] [CrossRef]
  22. Almeida, T.D.C.; Bandeira, M.C.E.; Moreira, R.M.; Mattos, O.R. New insights on the role of CO2 in the mechanism of carbon steel corrosion. Corros. Sci. 2017, 120, 239–250. [Google Scholar] [CrossRef]
  23. Mazumder, M.A.J.; Al-Muallem, H.A.; Ali, S.A. The effects of N-pendants and electron-rich amidine motifs in 2-(p-alkoxyphenyl)-2-imidazolines on mild steel corrosion in CO2-saturated 0.5 M NaCl. Corros. Sci. 2015, 90, 54–68. [Google Scholar] [CrossRef]
  24. Kahyarian, A.; Nesic, S. H2S corrosion of mild steel: A quantitative analysis of the mechanism of the cathodic reaction. Electrochim. Acta 2019, 297, 676–684. [Google Scholar] [CrossRef]
  25. Li, J.; Ma, H.; Zhu, S.; Qu, C.; Yin, Z. Erosion resistance of CO2 corrosion scales formed on API P110 carbon steel. Corros. Sci. 2014, 86, 101–107. [Google Scholar] [CrossRef]
  26. Zhang, G.; Cheng, Y. Electrochemical characterization and computational fluid dynamics simulation of flow-accelerated corrosion of X65 steel in a CO2-saturated oilfield formation water. Corros. Sci. 2010, 52, 2716–2724. [Google Scholar] [CrossRef]
  27. Zhang, Y.; Pang, X.; Qu, S.; Li, X.; Gao, K. Discussion of the CO2 corrosion mechanism between low partial pressure and supercritical condition. Corros. Sci. 2012, 59, 186–197. [Google Scholar] [CrossRef]
  28. Webster, S. Corrosion Inhibition Selection for Oil Field Pipelines; Corrosion 93, Paper 109; NACE International: Houston, TX, USA, 1993. [Google Scholar]
  29. Kairy, S.K.; Zhou, S.; Turnbull, A.; Hinds, G. Corrosion of pipeline steel in dense phase CO2 containing impurities: A critical review of test methodologies. Corros. Sci. 2023, 214, 110986. [Google Scholar] [CrossRef]
  30. Wang, D.; Wang, J.; Li, H.; Wu, Y. Pectin-amino acid derivatives as highly efficient green inhibitors for the corrosion of N80 steel in CO2-saturated formation water. Ind. Crops Prod. 2022, 189, 115866. [Google Scholar] [CrossRef]
  31. Desai, P.D.; Pawar, C.B.; Avhad, M.S.; More, A.P. Corrosion inhibitors for carbon steel: A review. Vietnam. J. Chem. 2023, 61, 15–42. [Google Scholar]
  32. Zhang, X.; Wang, F.; He, Y.; Du, Y. Study of the inhibition mechanism of imidazoline amide on CO2 corrosion of Armco iron. Corros. Sci. 2001, 43, 1417–1431. [Google Scholar] [CrossRef]
  33. Olajire, A.A. Corrosion inhibition of offshore oil and gas production facilities using organic compound inhibitors–A review. J. Mol. Liq. 2017, 248, 775–808. [Google Scholar] [CrossRef]
  34. Obot, I.B.; Onyeachu, I.B.; Umoren, S.A. Alternative corrosion inhibitor formulation for carbon steel in CO2-saturated T brine solution under high turbulent flow condition for use in oil and gas transportation pipelines. Corros. Sci. 2019, 159, 108140. [Google Scholar] [CrossRef]
  35. Tyusenkov, A.S.; Nasibullina, O.A. Inhibitory anticorrosive protection of oilfield equipment. Mater. Sci. Eng. 2019, 687, 06602. [Google Scholar] [CrossRef] [Green Version]
  36. Harrop, D.; Webster, S.; McMahon, A.J.; Paisley, D.E.; Partridge, G.J. CO2 Corrosion: A Testing Problem with a Predictive Solution; European Federation of Corrosion Problems: Brussels, Belgium, 1994. [Google Scholar]
  37. Gabe, D.R. The Rotating Cylinder Electrode. J. Appl. Electrochem. 1974, 4, 91–108. [Google Scholar] [CrossRef]
  38. Schlichting, H.; Gersten, K. Boundary Layer Theory, 9th ed.; Springer: Berlin/Heidelberg, Germany, 2017. [Google Scholar]
  39. Theodorsen, T.; Regier, A. Experiments on Drag of Revolving Disks. Cylinders and Streamline Rods at High Speeds. BiblioGov 2013. [Google Scholar]
  40. Pine Research. Study of Mass Transport Limited Corrosion with Rotating Cylinder Electrodes. Document #: DRA10077 (REV004). 2020. Available online: http://www.pineresearch.com (accessed on 29 March 2023).
  41. Li, W.; Xiong, Y.; Brown, B.; Kee, K.E.; Nesic, S. Measurement of Wall Shear Stress in Multiphase Flow and Its Effect on Protective FeCO3 Corrosion Product Layer Removal. In Proceedings of the CORROSION 2015, Dallas, TX, USA, 15–19 March 2015; p. NACE-2015-5922. [Google Scholar]
  42. ASTM G111–97; Standard Guide for Corrosion Tests in High Temperature or High-Pressure Environment, or Both. ASTM: West Conshohocken, PA, USA, 2018.
  43. ASTM G170–01; Standard Guide for Evaluating and Qualifying Oilfield and Refinery Corrosion Inhibitors in the Laboratory. ASTM: West Conshohocken, PA, USA, 2017.
  44. ASTM G185–06; Standard Practice for Evaluating and Qualifying Oil Field and Refinery Corrosion Inhibitors Using the Rotating Cylinder Electrode. ASTM: West Conshohocken, PA, USA, 2006.
  45. Smith, C.F.; Dollarhide, F.E.; Byth, N.J. Acid Corrosion Inhibitors—What We Need? Pet. Technol. 1978, 30, 737–746. [Google Scholar] [CrossRef]
  46. Dougherty, J.A. Effect of Treatment Method on Corrosion Inhibitor Performance; Corrosion 97, Paper No. 344; NACE International: Houston, TX, USA, 1997. [Google Scholar]
  47. Jovanciceciv, V.; Ramachandran, S.; Prince, P. Inhibition of CO2 Corrosion of Mild Steel by Imidazolines and Their Precursors; Corrosion 98, Paper No. 18; NACE International: Houston, TX, USA, 1998. [Google Scholar]
  48. Abayarathna, D.; Naraghi, A.; Grahmann, N.; Buchholz, B.; Blumer, D.J. Inhibitor Evaluations and Correlation of Laboratory and Field Data in CO2 Environments; Corrosion 99, Paper No. 33; NACE International: Houston, TX, USA, 1999. [Google Scholar]
  49. Jovancicevic, V.; Ahn, Y.S.; Dougherty, A. CO2 Corrosion Inhibition by Sulfur Containing Organic Compounds; Corrosion 2000, Paper No. 00007; NACE International: Houston, TX, USA, 2000. [Google Scholar]
  50. Wright, E.J.; Efird, K.D.; Boros, A.J.; Hailey, T.G. Rotating Cylinder Electrode (RCE) Simulation of Corrosion in Sweet Production; Corrosion, Paper No. 08629; NACE International: Houston, TX, USA, 2008. [Google Scholar]
  51. Walsh, F.; Kear, G.; Nahlé, A.; Wharton, J.; Arenas, L. The rotating cylinder electrode for studies of corrosion engineering and protection of metals–An illustrated review. Corros. Sci. 2017, 123, 1–20. [Google Scholar] [CrossRef] [Green Version]
  52. Olvera-Martínez, M.E.; Mendoza-Flores, J.; Genesca, J. CO2 corrosion control in steel pipelines. Influence of turbulent flow on the performance of corrosion inhibitors. J. Loss Prev. Process Ind. 2015, 35, 19–28. [Google Scholar] [CrossRef]
  53. Richter, S.; Achour, M.; Addis, K.; Singer, M.; Nesic, S. Development and Application of a Downhole Corrosion Prediction Mode; NACE International: Houston, TX, USA, 2016. [Google Scholar]
  54. Askari, M.; Aliofkhazraei, M.; Jafari, R.; Hamghalam, P.; Hajizadeh, A. Downhole corrosion inhibitors for oil and gas production–a review. Appl. Surf. Sci. Adv. 2021, 6, 100128. [Google Scholar] [CrossRef]
  55. Owen, J.; Ramsey, C.; Barker, R.; Neville, A. Erosion-corrosion interactions of X65 carbon steel in aqueous CO2 environments. Wear 2018, 414, 376–389. [Google Scholar] [CrossRef]
  56. Gómez, O.; Aponte, H.; Vera, E.; Pineda, Y. Evaluation of corrosion inhibitor simulating conditions of operation. IOP Conf. Ser. J. Phys. Conf. Ser. 2017, 935, 012060. [Google Scholar] [CrossRef] [Green Version]
  57. Fontana, M.G. Corrosion Engineering, 3rd ed.; Mc. Graw Hill: New York, NY, USA, 1987. [Google Scholar]
Figure 1. (A) Corrosion loop and its components; (B) coupon.
Figure 1. (A) Corrosion loop and its components; (B) coupon.
Applsci 13 04586 g001
Figure 2. Curves obtained through polarization resistance to different rpm of the corrosion inhibitors.
Figure 2. Curves obtained through polarization resistance to different rpm of the corrosion inhibitors.
Applsci 13 04586 g002aApplsci 13 04586 g002b
Figure 3. Fractographies of the tested graduated cylinders (20×). The yellow arrows show the presence of pitting according to Smith’s criterion.
Figure 3. Fractographies of the tested graduated cylinders (20×). The yellow arrows show the presence of pitting according to Smith’s criterion.
Applsci 13 04586 g003
Figure 4. Curves obtained from each test. The x-axis shows the period of time, whereas the left y-axis shows the CR and the right y-axis shows the imbalance values.
Figure 4. Curves obtained from each test. The x-axis shows the period of time, whereas the left y-axis shows the CR and the right y-axis shows the imbalance values.
Applsci 13 04586 g004
Figure 5. Pictures of the tested samples for each inhibitor. The circles and yellow arrows show the presence of localized corrosion (20×).
Figure 5. Pictures of the tested samples for each inhibitor. The circles and yellow arrows show the presence of localized corrosion (20×).
Applsci 13 04586 g005
Figure 6. Different zones in which the inhibitor works. Zone 1: the time the inhibitor takes to coat the graduated cylinder and inhibit. Zone 2: the period during which the inhibitor works. Zone 3: the period in which the inhibitor stops working, and the corrosion rate increases.
Figure 6. Different zones in which the inhibitor works. Zone 1: the time the inhibitor takes to coat the graduated cylinder and inhibit. Zone 2: the period during which the inhibitor works. Zone 3: the period in which the inhibitor stops working, and the corrosion rate increases.
Applsci 13 04586 g006
Table 1. Polarization resistance essays in a rotating cylinder in a NACE solution. Corrosion rate (CR) and inhibitor’s efficiency with respect to the general corrosion.
Table 1. Polarization resistance essays in a rotating cylinder in a NACE solution. Corrosion rate (CR) and inhibitor’s efficiency with respect to the general corrosion.
RPMInhibitor 1Inhibitor 2Inhibitor 3Inhibitor 4
6000CR = 1.71 mm/yearCR = 7.89 mm/yearCR = 6.62 mm/yearCR = 1.8 mm/year
Ec = −619 mVEc = −552 mVEc = −535 mVEc = −622 mV
CC = 0.38 mACC = 1.5 mACC = 1.33 mACC = 0.29 mA
Efficiency = 91.10%Efficiency = 58.93%Efficiency = 65.54%Efficiency = 90.63%
4000CR = 1.27 mm/yearCR = 4.57 mm/yearCR = 6.18 mm/yearCR = 1.49 mm/year
Ec = −616 mVEc = −576 mVEc = −613 mVEc = −612 mV
CC = 0.27 mACC = 0.97 mACC = 1.30 mACC = 0.31 mA
Efficiency = 93.39%Efficiency = 76.21%Efficiency = 67.83%Efficiency = 92.24%
2000CR = 1.23 mm/yearCR = 4.78 mm/yearCR = 1.8 mm/yearCR = 1.62 mm/year
Ec = −596 mVEc = −578 mVEc = −600 mVEc = −603 mV
CC = 0.26 mACC = 1.22 mACC = 0.29 mACC = 0.38 mA
Efficiency = 93.60%Efficiency = 75.12%Efficiency = 90.63%Efficiency = 89.85%
4000CR = 1.43 mm/yearCR = 4.08 mm/yearCR = 7.72 mm/yearCR = 1.95 mm/year
Ec = −596 mVEc = −578 mVEc = −550 mVEc = −602 mV
CC = 0.30 mACC = 1.12 mACC = 1.60 mACC = 0.41 mA
Efficiency = 92.56%Efficiency = 78.76%Efficiency = 59.81%Efficiency = 89.85%
6000CR = 1.32 mm/yearCR = 6.18 mm/yearCR = 7.72 mm/yearCR = 1.77 mm/year
Ec = −599 mVEc = −568 mVEc = −555 mVEc = −589 mV
CC = 0.28 mACC = 1.30 mACC = 1.61 mACC = 0.37 mA
Efficiency = 93.13%Efficiency = 67.83%Efficiency = 59.81%Efficiency = 90.79%
Table 2. Smith’s criterion for assessing corrosion levels.
Table 2. Smith’s criterion for assessing corrosion levels.
RankDescription of Pitting
0No pits. Surface same as for original untreated coupon.
1Intergranular corrosion on cut edge of coupon, giving a sintered effect; no pits on major surfaces.
2Small, shallow pits on cut edges; no pits on major surfaces.
3Scattered, very shallow pinpoint pits, less than 25 pits on either surface—that is, front or back.
4More than 25 pits of Rank 3 on either surface.
5Ten or fewer pits, 1/332 to 1/16 in. diameter and 1/64 to 1/32 in. deep.
6Between 11 and 25 pits of Rank 5.
7More than 25 pits of Rank 5.
8Pits larger than 1/16 in. but less than 1/8 in. in diameter, greater than 1/32 in. deep, 100 or fewer in number.
9Any pitting more severe than Rank 8.
Table 3. Measurements of corrosion rate relative to weight loss and LPR.
Table 3. Measurements of corrosion rate relative to weight loss and LPR.
Corrosion
Inhibitor
1234
C1
CR (mm/years)
2.983.064.569.05
C2
CR (mm/years)
2.492.533.857.13
LPR
CR (mm/years)
2.322.696.078.58
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Bianchi, G.L.; Acosta, V.; Seijas, C. A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection. Appl. Sci. 2023, 13, 4586. https://doi.org/10.3390/app13074586

AMA Style

Bianchi GL, Acosta V, Seijas C. A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection. Applied Sciences. 2023; 13(7):4586. https://doi.org/10.3390/app13074586

Chicago/Turabian Style

Bianchi, Gustavo Luis, Verónica Acosta, and Carlos Seijas. 2023. "A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection" Applied Sciences 13, no. 7: 4586. https://doi.org/10.3390/app13074586

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop