Next Article in Journal
Design, Analysis, and 3D Printing of a Patient-Specific Polyetheretherketone Implant for the Reconstruction of Zygomatic Deformities
Next Article in Special Issue
Role of Hydrophobic Associations in Self-Healing Hydrogels Based on Amphiphilic Polysaccharides
Previous Article in Journal
A DR/NIR Hybrid Polymeric Tool for Functional Bio-Coatings: Theoretical Study, Cytotoxicity, and Antimicrobial Activity
Previous Article in Special Issue
Structure-Bioactivity Relationship of the Functionalized Polysulfone with Triethylphosphonium Pendant Groups: Perspective for Biomedical Applications
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Sustainable Multi-Network Cationic Cryogels for High-Efficiency Removal of Hazardous Oxyanions from Aqueous Solutions

by
Ecaterina Stela Dragan
1,*,
Doina Humelnicu
2 and
Maria Valentina Dinu
1
1
Department of Functional Polymers, “Petru Poni” Institute of Macromolecular Chemistry, Grigore Ghica Voda Alley 41 A, 700487 Iasi, Romania
2
Faculty of Chemistry, Alexandru Ioan Cuza University of Iasi, Carol I Bd. 11, 700506 Iasi, Romania
*
Author to whom correspondence should be addressed.
Polymers 2023, 15(4), 885; https://doi.org/10.3390/polym15040885
Submission received: 22 January 2023 / Revised: 6 February 2023 / Accepted: 7 February 2023 / Published: 10 February 2023
(This article belongs to the Special Issue Self-Healing Polymers, Proteins and Composites)

Abstract

:
It is still a challenge to develop advanced materials able to simultaneously remove more than one pollutant. Exclusive cationic composite double- and triple-network cryogels, with adequate sustainability in the removal of Cr2O72− and H2PO4 oxyanions, were developed in this work starting from single-network (SN) sponges. Chitosan (CS), as the only polycation originating from renewable resources, and poly(N,N-dimethylaminoethylmethacrylate) (PDMAEMA) and polyethyleneimine (PEI), as synthetic polycations, were employed to construct multi-network cationic composite cryogels. The properties of the composites were tailored by the cross-linking degree of the first network (SN5 and SN20, which means CS with 5 or 20 mole % of glutaraldehyde, respectively) and by the order of the successive networks. FTIR, SEM-EDX, equilibrium water content and compressive tests were used in the exhaustive characterization of these polymeric composites. The sorption performances towards Cr2O72− and H2PO4 anions were evaluated in batch mode. The pseudo-first-order, pseudo-second-order (PSO) and Elovich kinetics models, and the Langmuir, Freundlich and Sips isotherm models were used to interpret the experimental results. The adsorption data were the best fitted by the PSO kinetic model and by the Sips isotherm model, indicating that the sorption mechanism was mainly controlled by chemisorption, irrespective of the structure and number of networks. The maximum sorption capacity for both oxyanions increased with the increase in the number of networks, the highest values being found for the multi-network sponges having SN5 cryogel as the first network. In binary systems, all sorbents preferred Cr2O72− ions, the selectivity coefficient being the highest for TN sponges. The high sorption capacity and remarkable reusability, with only a 4–6% drop in the sorption capacity after five sorption–desorption cycles, recommend these composite cryogels in the removal of two of the most dangerous pollutants represented by Cr2O72− and H2PO4.

1. Introduction

The presence of highly toxic pollutants, such as heavy metal ions (HMIs) and dyes in aquatic environments, as a consequence of intensive industrialization and of anthropogenic activities, represents the main cause of the deep deterioration of water quality, which threatens public health [1,2,3,4,5]. Among HMIs, Cr(VI) is present in wastewaters in a high concentration as a result of mining activities, electroplating, dyeing, pigment manufacture, leather tanning, pesticides production, textile industries, wood preservation and alloy and steel manufacturing [6]. Cr(VI) compounds present as HCrO4, CrO42− and Cr2O72− oxyanions (depending on pH and Cr(VI) concentration) are known for their toxicity, high solubility and high diffusivity, which allow them to easily cross the cellular membrane [6]. Cr(VI) is carcinogenic and mutagenic for living organisms and has a corrosive effect on tissues, causing pulmonary congestion and damage of the liver, stomach and kidney [6,7]. Therefore, the World Health Organization has limited the total concentration of chromium in drinking water to 0.05 mg/L. Thus, various methodologies have been employed to decrease the chromium concentration under this limit, such as precipitation, ion exchange, membrane filtration, reverse osmosis and adsorption. Among all known techniques in use for the removal of Cr(VI), adsorption technology is the most widely explored due to its intrinsic advantages, such as lower capital costs, effectiveness, environmental friendliness, due to the absence of further waste materials, and high effectiveness at low concentrations of pollutant compared with other methods [3,6,7]. It is still a challenge to design novel sorbents endowed with enhanced sorption capacity and high stability during utilization. Ion exchangers [8,9,10,11,12] or nitrogen-containing fabrics [13], bearing plenty of quaternary ammonium groups and/or secondary and tertiary amine groups, have demonstrated so far high sorption capacities and reusability in the removal of Cr(VI). Increasing attention has been recently focused on using composite hydrogels in environmental remediation, where they have outcompeted many of the conventional adsorbents by their sorption performances such as fast sorption kinetics and high sorption capacity. Chitosan (CS)-based composites are among the most investigated bio-sorbents with clear performances in the removal of various pollutants [7,14,15,16].
Besides Cr(VI), phosphate is a dangerous contaminant, and its concentration in waters requires steady surveillance because concentrations of phosphate higher than 1 ppm in treated wastewater are responsible for the growth of blue-green algae and hyacinth-like plants, which decrease the content of dissolved oxygen, having as the last consequence the death of plants and animals. Various synthetic anion exchangers [17,18,19,20] as well as composite biosorbents, mainly based on cellulose, CS and alginate [17,21,22,23,24,25,26,27,28], have been used in the adsorption of phosphate anions. The selectivity for phosphate ions increased by loading the sorbent with metal ions such as Zr(IV) [19,22,23,24], Fe(III) [24,25] and La(III) [27,28]. Among the synthetic polycations, poly(ethyleneimine) (PEI) [29,30] and poly(N,N-dimethylaminoethyl methacrylate) (PDMAEMA) [31,32] demonstrated high ability in binding various anionic pollutants and heavy metal ions. In our previous investigations on the removal of phosphate anions from aqueous solutions, it has been revealed that the sorption capacity of some composite sponges could be enhanced, increasing the density of amine groups by the fabrication of multi-network cryogels [33,34], following the double network (DN) concept, promoted by Gong et al. [35], and intensively exploited lately by other groups [36,37,38,39]. These results prompted us to extend the study on the sorption performances of multi-network sponges constructed with CS, PEI and PDMAEMA by changing the building order of the networks in DN and triple-network (TN) composites. This approach enlarges the possibilities to diversify the density and distribution of the cationic groups, on the one hand, and the mechanical properties of the composite sponges, on the other hand, and contributes to the increase in the sustainability of these composites in the sorption process of various pollutants. The application of such composites in the removal of Cr(VI) as Cr2O72− oxyanions in comparison with phosphate anions is presented for the first time in this work. The composite sponges were characterized by FTIR spectroscopy, SEM-EDX, swelling at equilibrium, and compressive tests. The sorption performances were evaluated as a function of contact time and initial concentration of each oxyanion. To gain information on the interaction mechanism between the composite sorbent and oxyanions, the experimental kinetics and equilibrium data were fitted with some mathematical models. The selectivity of a certain composite cryogel for one of the two oxyanions (Cr2O72− and H2PO4) and the reusability of the selected composites, in connection with their structure, were also thoroughly examined.

2. Materials and Methods

2.1. Materials

CS low molecular weight as powder, ethyleneglycol diglycidyl ether (EGDGE) 50%, glutaraldehyde (GA) as aqueous solution with a concentration of 25 wt.%, N,N′-methylenebisacrylamide (BAAm) (99%), ammonium persulfate (APS) (99%) and N,N,N′,N′-tetramethyl ethylenediamine (TEMED) (99%) were supplied from Sigma-Aldrich (Schnelldorf, Germany) and used as received. The deacetylation degree of CS was evaluated by recording its FTIR spectrum in KBr pellets with a Vertex 70 Bruker FTIR spectrometer (Bruker, Ettlingen, Germany). An average value of 85% was obtained from three determinations. The viscometric average molecular weight (Mv) of CS, assessed according to Ref. [40], was 305 kDa. Two sorts of branched PEI, as aqueous solution with a concentration of 50 wt.%, were used in this work: PEI with average weight molar mass of 1800 g/mole (PEI18) and 25,000 g/mole (PEI25), respectively. N,N-dimethylaminoethyl methacrylate (DMAEMA) (98%), purchased from Sigma-Aldrich, was distilled at 47 °C, at reduced pressure (about 4 mm Hg), and kept at 4 °C. K2Cr2O7 (≥99%) from Sigma-Aldrich (Schnelldorf, Germany) and KH2PO4 (≥99%) from Merck Chemical Co. (Buchs, Switzerland) were used as sources for oxyanions. 1,5-diphenylcarbazide, (NH4)6Mo7O24∙4H2O (99%), potassium antimony (III) tartrate hemihydrate (≥99%) were supplied from Sigma-Aldrich (Schnelldorf, Germany) and used as received. Acetic acid, HCl and NaOH were purchased from Chemical Company (Romania) and used as received.

2.2. Preparation of Cationic Composite Cryogels

All cryogels prepared and characterized in this work are presented in Table 1.
Two single-network cryogels consisting of CS cross-linked with GA, with two concentrations, i.e., 5 mole % and 20 mole %, the sample codes being SN5 and SN20, respectively, were prepared first following the protocol presented in the previous paper [34]. For the fabrication of DN and TN composites having SN20 as the first network, the following steps were taken. To obtain SN20 sponges, 2.44 mL aqueous solution of GA, with a concentration of 2.5 wt.%, was dropped under vigorous magnetic stirring on 30 g aqueous solution of 2 wt.% CS in 2 vol % CH3COOH in an ice bath. The stirring went on for 45 min after the addition of GA and then the reaction mixture was loaded in syringes of 10 mL, sealed with parafilm and transferred to a freezer at −18 °C for 24 h. The monoliths were then kept for 30 min at room temperature, cut at about 10 mm length and immersed in distilled water for about 72 h. The SN monoliths were freeze-dried in a Martin Christ, ALPHA 1-2LD device, for 48 h at −57 °C and 0.045 mbar. The fragments of SN cryogels were loaded at saturation with (1) a monomer mixture consisting of DMAEMA (10 wt.%), BAAm (5 moles BAAm: 100 moles of DMAEMA), TEMED and APS (2 wt.% to monomer and cross-linker) to prepare DN20.1 (Table 1); (2) aqueous solution of PEI25 containing 5 mole % of EGDGE thus obtaining the composite DN20.2 (Table 1); and (3) aqueous solution of PEI18 (C = 15 wt.%) containing 5 mole % of EGDGE, thus obtaining DN20.3 (Table 1). To prepare the third networks, namely TN20.1, TN20.2 and TN20.3 composite cryogels, the DN20.1, DN20.2 and DN20.3 cryogels, respectively, were swollen at saturation in an aqueous solution of PEI18 (10 wt.%) containing EGDGE in a molar ratio of 5 moles EGDGE: 100 moles PEI (Table 1). A monomer mixture consisting of DMAEMA (10 wt.%), BAAm (5 moles BAAm: 100 moles of DMAEMA) TEMED and APS (2 wt.% to monomer and cross-linker) was adsorbed into DN5 cryogel to obtain TN5.2 composite (Table 1). The formation of the third network was conducted in a cryostat at −18 °C. After 24 h, the TN cryogels were thawed at room temperature (RT) and intensively washed with distilled water for at least 72 h to leach out all unreacted compounds. The TN composite cryogels were finally dried by lyophilization.

2.3. Characterization of Cationic Composite Cryogels

The FTIR spectra in the 4000–400 cm−1 range were recorded on a Bruker Vertex FTIR spectrometer by the KBr pellet technique. An amount of about 5 mg of sample was placed in each pellet. All FTIR spectra were processed by ACD/Spec Viewer 5.04 Software. To evaluate the internal morphology and the elemental composition of the cryogels, a Quanta 200 environmental scanning electron microscope (ESEM) (FEI Company, Hillsboro, Oregon, USA) type Quanta 200) coupled with an energy-dispersive X-ray (EDX) detector was used. The ImageJ 1.48v software was employed to determine the average diameter of pores and the thickness of the pore walls of the cryogels. In this regard, three independent SEM micrographs were utilized, and the values were reported as the average of at least 15 pores ± standard deviations [41].
Swelling ratio (SR) was evaluated by immersing samples of composite cryogels (about 0.01 g) in 20 mL distilled water, up to the equilibrium of swelling. The samples were weighed after the removal of water in excess, and the SR values was calculated with Equation (1) [42]:
S R = W e q W d
where Weq represents the mass of swollen gel at equilibrium, and Wd is the mass of cryogel in dry state.
Equilibrium water content (EWC) was evaluated by Equation (2) [43]:
E W C = [ ( W e q W d ) / W d ] × 100
where Weq and Wd have the same meaning as in Equation (1).
To assess the mechanical behavior of SN, DN and TN cryogels, uniaxial compression measurements were performed with a Shimadzu Testing Machine (EZ-LX/EZ-SX Series, Kyoto, Japan) on equilibrium swollen samples. All cryogels were cut as monoliths with a diameter of about 12–14 mm and a height of 4–6 mm. Before each compression test, an initial force of 0.1 N was applied to ensure the complete contact between the surface of cryogels and the plates of the testing equipment. The stress–strain profiles were recorded using a cross-head speed of 1 mm min−1 and a force of 50 N. The compressive stress (σ, kPa), strain (ε) and the elastic moduli (G, kPa) were calculated according to the previously published protocols for other porous-based materials [34,44,45,46].

2.4. Sorption of Oxyanions

Batch sorption of oxyanions onto the SN, DN and TN cryogels was carried out in a temperature-controlled shaker (GFL 1083, Gemini BV, Steinfurt, Germany), vibrated at ~160 rpm, using 0.0075 g of sorbent and 10 mL of oxyanion solution. The pH of the solutions was adjusted with 0.1 M HCl or 0.1 M NaOH. After shaking for a certain time, the sorbent was separated by filtering through a 0.45 μm membrane filter. The evaluation of the concentration of Cr(VI) was performed by the 1,5-diphenylcarbazide method, in acidic medium, using a UV–Vis spectrophotometer (Hitachi U-2001, λ = 540 nm) [8,47]. The concentration of phosphate ions in aqueous solution was determined by the colorimetric method in the presence of ammonium molibdatum and potassium antimonyl tartrate using ascorbic acid as a reduction agent (λ = 888 nm), with a UV–Vis Hitachi U-2001 spectrophotometer (Hitachinaka, Ibaraki 312-8504, Japan) [48]. The mean of three readings for each sample was used for the calculation of the sorption results. The adsorption capacity at a certain contact time, qt (mg/g), was calculated with Equation (3):
q t = ( C o C t ) V m
where Co—initial concentration of pollutant (mg/L), Ct—concentration of pollutant in the aqueous solution at a certain duration (mg/L), V—volume of the aqueous solution (L), m—mass of sorbent (g).
The removal efficiency (RE) was calculated with Equation (4):
R E = C o C e C o × 100
where Co has the same meaning as in Equation (4) and Ce is the concentration of pollutant in the aqueous solution at equilibrium.
The evaluation of kinetics and isotherm parameters was performed by a non-linear regression method using two error functions to assess the level of fit: the correlation coefficient of determination (R2) and the non-linear Chi-square (χ2) test, calculated by Equation (5):
χ 2   = ( q e , e x p q e , c a l ) 2   q e , c a l
where qe,exp and qe,cal represent the experimental data (mg/g) and the data calculated by models (mg/g), respectively.
Sorption of oxyanions in di-component systems was performed in the following conditions: Vsol = 10 mL; sorbent dose 0.0075 g; Co = 100 mg/L (for each oxyanion); 25 °C; contact time 4 h. The selectivity coefficient for the sorption of oxyanions was evaluated with Equation (6):
k H 2 P O 4 C r 2 O 7 2 = K d C r 2 O 7 2 K d H 2 P O 4
where K d C r 2 O 7 2 and K d H 2 P O 4 represent the distribution constants of Cr2O72− and H2PO4 oxyanions, respectively.

3. Results

3.1. Synthesis and Characterization of Multi-Network Cationic Composite Cryogels

3.1.1. Synthesis

The principle which is based on the fabrication of multi-network architectures has already been described [33,34,35,36]. This strategy is accessible and extremely versatile given the possibility to increase, in a controlled manner, the density of a certain category of functional groups. Figure 1 summarizes the strategy used in this work to spread out the structure of the DN and TN composite cryogels starting from the single-network SN20.
As can be seen in Figure 1, the second network was generated either by cross-linking polymerization of DMAEMA at a concentration of 10 wt.%, thus obtaining the composite DN20.1, or by the cross-linking with EGDGE of PEI having two molar masses (PEI25 and PEI18), thus obtaining the composites DN20.2 and DN20.3, respectively. The third network was the same for all TN cryogels, i.e., PEI18 (10 wt.%) (Table 1, Figure 1). In all cases, PEI was cross-linked with 5 mole% EGDGE.

3.1.2. Characterization

Figure 2 presents the FTIR spectra of the series SN20 (CS), DN20.2 (CS/PEI25) and TN20.2 (CS/PEI25/PEI18) (from Figure 1). As expected, the main bands of CS are visible in the spectrum of SN20 cryogel, as follows: 2924 and 2876 cm−1, attributed to C-H and -CH2 stretching vibrations in CS; 1651 cm−1, assigned to the stretching vibration of C=O bond in the secondary amide bond and to the Schiff base; 1566 and 1410 cm−1, attributed to the –NH bending vibration in amide II, and to C-H and -CH2 stretching, respectively; 1323 cm−1, assigned to N-H stretching in amide (amide III); 1259 cm−1, assigned to the C-N stretching modes; the large band at 1076 cm−1 indicates the C-O-C anti-symmetric stretching in CS [49,50,51]. By the construction of the second network (PEI25), significant changes in the position of the main bands are obvious in the spectrum of the DN20.2 composite. The sharp band located at 1462 cm−1 supports the presence of PEI, while the bands at 1364 and 1302 cm−1 indicate CH3 symmetrical deformation mode and the amide III [49]; the bands at 1097 and 943 cm−1 were assigned to the C-O-C anti-symmetric stretching, and the wagging of the saccharide structure of CS. The construction of the third network (PEI18) in TN20.2 did not lead to dramatic changes in the spectrum, just small blue or red shifts; for example, the band at 1566 cm−1 in SN20 was blue-shifted at 1572 cm−1 in TN20.2, the band at 1462 cm−1 was blue-shifted to 1466 cm−1, the band at 1364 cm-1 in DN20.2 was shifted at 1358 cm-1 and the band at 943 cm−1 appears as a shoulder after the construction of the third network, while the band at 897 cm−1 in SN20, assigned to the wagging of saccharide structure, was red-shifted at 893 cm−1 in DN20.2 and at 868 cm−1 in TN20.2.
The FTIR spectra of SN5, DN5 and TN5.2 sponges are compared in Figure S1. The bands located at 2924 and 2677 cm−1 in SN5, at 2924 and 2822 cm−1 in DN5, and at 2926 and 2822 cm−1 in TN5.2 were attributed to C-H and -CH2 stretching vibrations; the bands situated at 1632, 1651 and 1631 cm−1 in SN5, DN5 and TN5.2, respectively, were assigned to the stretching vibration of C=O bond in the secondary amide bond and to the Schiff base. The large bands located at 1076 cm−1 in SN5, 1115 cm−1 in DN5 and 1159 cm−1 in TN5.2 indicate the C-O-C anti-symmetric stretching in CS [49,50,51]. The sharp bands located at 1442 cm−1 in SN5, 1462 cm−1 in DN5 and 1451 cm−1 in TN5.2 were assigned to methylene C-H bending vibrations [51]. The presence of PDMAEMA as the third network is supported by the band at 1731 cm−1 attributed to the C-O bond in the ester group and the strong band at 1451 cm−1. Figure S2 presents the FTIR spectra of DN20.3 and TN20.3 composite sponges. As can be seen, these spectra are similar because the second and the third networks were constituted of PEI18 cross-linked with EGDGE.
SEM images in Figure 2 support the morphological changes which occurred during the successive construction of the networks. The pore sizes and the wall thickness become smaller and bigger, respectively, after the addition of the second and third networks, both for SN5 and SN20 as the first network. It is obvious that the compactness of the composites was higher when the first network was SN20, the theoretical cross-linking degree being four times higher compared with that of SN5. The size of pores and the wall thickness for some representative composite cryogels are presented in Table S1 and show the dramatic decrease in the pore sizes by the construction of the second network (DN5 compared with SN5 and DN20.2 compared with SN20). The pore size and pore wall thickness further decreased and increased, respectively, by the construction of the third network (Table S1).
The elemental analyses obtained from EDX spectra, and given in Table S2, support the structure of the composites. As can be seen, the value of nitrogen content in the SN20 cryogel is lower than in the SN5 cryogel because a higher content of GA had as a consequence increasing carbon content and decrease of nitrogen and oxygen content. The construction of the PEI network led to the increase in carbon and nitrogen content and to the decrease in oxygen content (DN5 and DN20.2). The strong difference between the values of elements in the case of the composites TN5.1 and TN5.2 is attributed to the third network, which was PEI in the first case and PDMAEMA for TN5.2. The difference between the element content in the case of DN20.2 and TN20.2 was not so significant because the second and the third networks were constituted of PEI.
The values of SR and EWC, presented in Table S3, clearly indicate the differences between SN5 and SN20 caused by the differences in cross-linking degrees. Thus, for SN5, the values of SR and EWC were 64.69% and 98.45%, respectively, while for SN20, the values of these characteristics were 45.25% and 97.79%. The values of SR and EWC dramatically decreased with the construction of the second network (DN5, DN20.1, DN20.2 and DN20.3), while the decrease was less significant when the third network was added (TN5.1, TN5.2, TN20.1, TN20.2 and TN20.3).
Uniaxial stress–strain compression tests were first performed to evaluate the mechanical strength of the SN cryogels, namely SN5 and SN20. The stress–strain curves presented in Figure 3a,b show typical elastic behavior characteristic of cryogels, with sustained compression values beyond 70% and without any deformation or failure of the gel networks. Moreover, after the removal of the load, the SN5 and SN20 cryogels reabsorbed the water released during compression and regained their original shape. Consequently, in order to further evaluate their resilience and robustness, the dynamic stress–strain behavior of these cryogels was carried out for five successive loading cycles at 95% maximum strain. The results in Figure 3c,d and Table S4 (Supplementary Materials) demonstrate the remarkable mechanical stability of the SN5 and SN20 cryogels upon successive compression experiments; the values of the maximum sustained compression, the compressive strength and the compressive moduli remained almost unchanged after five successive cycles of compression. It should be pointed out that SN5 and SN20 cryogels exhibited unique mechanical features (high elasticity, non-brittleness, shape recovery), which support their further use as matrices/scaffolds for construction of multi-network composite cryogels. By employing PEI18 and EGDGE to prepare the second network, stiffer DN cryogels were obtained, which can sustain 53% (sample DN5) and 31.18% (sample DN20.3) compression before fracture, respectively (Figure 4 and Table 2). The crack development in DN cryogels at low strain can be associated with the drastically decreased values of the swelling ratio of the DN cryogels in comparison with those of SN cryogels (see Table S4, Supplementary Materials).
However, the compressive moduli of DN cryogels, calculated as the gradient of the initial linear portion in the stress–strain curve (Figure 4c), increased with the addition of the second network. For instance, DN5 and DN20.3 cryogels exhibited an elastic modulus about five and thirty times higher than that of the starting networks (SN5 and SN20), respectively. Thus, increasing the polymer content led to more dense and rigid networks. Moreover, the construction of the third network based on PEI18 or PDMAEMA matrices led to a further improvement of the elastic modulus of the composite cryogels (samples TN5.1 and TN5.2; Table 2). Furthermore, the TN5.1 cryogels remained mechanically stable and sustained 69.02% compression at a compressive nominal stress of 538.2 kPa (Figure 4a and Table 2). Thus, the use of PEI18 to prepare the third network increased the flexibility of the TN5.1 network and hampered its failure. On the other hand, when SN20 cryogels, having a higher cross-linking density (GA concentration 20 mole %), were used as starting networks for the construction of the TN networks (sample TN20.3), the mechanical properties were completely changed. A cross-linker content of 20% in the first network (TN20.3) induced an enhancement in the elastic modulus compared to a cross-linker content of 5% (TN5.1), but the fracture of the TN20.3 networks occurred at lower compression ratio (21.91%), while the TN5.1 cryogels were robust without deformation or fracture at higher strain.
Additionally, the uniaxial compression data proved that the PDMAEMA chains had a beneficial effect on the maximum sustained compression and compressive strength of DN cryogels (Figure 4 and Table 2). DN20.1 cryogels demonstrated mechanical stability and sustained 76.3% compression at a compressive nominal stress of 370.49 kPa, whereas DN20.2 and DN20.3 cryogels were broken at about 13.30% and 31.18% compression and compressive nominal stress of 14.45 kPa and 24.75, respectively (Figure 4b and Table 2). Nevertheless, the presence of a third network based on PEI18 determined a significant reinforcement of the TN20.2 cryogel network, which sustained 76.15% compression, at a compressive nominal stress of 282.35 kPa. In addition, the remarkable mechanical stability of TN5.1 and TN20.2 can be also associated with the well-interconnected networks of small pores observed for these cryogels (see SEM micrographs, Figure 2). An improvement of the mechanical strength with the decrease in pore sizes has also been previously reported for other porous hydrogels [34,52,53]. Finally, it should be emphasized that the mechanical properties of SN, DN and TN cryogels can be modulated by controlling (i) the cross-linker ratio of the first network, (ii) the nature and molar mass of the polycation used to prepare the second and third networks and (iii) the order of the network construction.

3.2. Sorption Performances

3.2.1. Sorption Kinetics

Sorption kinetics data obtained for the sorption of Cr2O72− oxyanions onto SN, DN and TN cryogels were plotted in Figure 5a–c. As Figure 6a shows, the values of qt at equilibrium increased with the increase in the number of cationic networks. For the same CS network, the values of sorption at equilibrium increased in the order SN < DN < TN. Moreover, it is obvious that the sorption at equilibrium was higher in the case of both TN cryogels, having SN5 as the first network, the difference consisting of the faster reaching of equilibrium in the case of TN5.2 composite, i.e., when the last network was PDMAEMA. These results are assigned to the higher number of cationic groups available for the electrostatic attraction of Cr2O72− oxyanions, in the case of a lower cross-linking degree. Figure 6d shows that the sorption of H2PO4 was also high and fast, the values being comparable with those of Cr2O72−.
By the non-linear fitting of the experimental kinetic data obtained for the sorption of Cr2O72− anions, the values of the kinetic parameters were obtained.
As can be seen in Tables S5–S7, the calculated values of qe better agreed with the experimental data in the case of the PSO kinetic model. The values of R2 and χ2 are the highest and the lowest, respectively, and show a high level of fit for this model. The PSO kinetic model is considered as the rate-limiting step for chemisorption as the most probable mechanism of sorption, which involves valence forces through sharing or exchange of electrons between all sorbents investigated in this work and Cr(VI) species [9,10,12,15,16,21]. The values of R2 found when the kinetic data were fitted with the Elovich model, which are in the range of 0.94–0.95, also support chemisorption as a possible mechanism of sorption.
The sorption kinetics of H2PO4 anions onto the novel multi-network cationic sorbents (DN20.1, DN20.2, TN20.1, TN20.2 and TN5.1; Table S8) confirm the previous reported results [34]. Chemisorption of this oxyanion is also supported by the highest values of R2 and the lowest values of χ2 in the case of PSO model compared with PFO model.

3.2.2. Isotherms

Sorption capacity at equilibrium was investigated to identify the sorbents with the best performances in the removal of Cr2O72− oxyanions. The experimental data and the fitting of three isotherm models (Langmuir, Freundlich and Sips) are presented in Figure 6a–c. As can be seen in Figure 6, the affinity of the cryogels for Cr2O72− anion was high in the case of composites derived from SN5 cryogel, increasing with the increase in the network number (TN5.1 compared with DN5). The sorption capacity was the highest when PDMAEMA was the third network (TN5.2).
The isotherm parameters for the sorption of Cr2O72− anions are presented in Table 3, Table 4 and Table 5. As Table 3 shows, the experimental isotherms for the sorption of Cr2O72− anions onto SN5 and derived composite cryogels were best fitted by the Sips isotherm model, the calculated values of qm being close to the experimental values for all sorbents. The values of R2 and χ2 were the highest and lowest, respectively, for this isotherm, thus supporting this isotherm as the most suitable to fit the experimental data. The highest value of qm was found in the case of the composite cryogel TN5.2, which has three networks, the last one being PDMAEMA.
The sorption data included in Table 4 show how the sorption capacity of Cr2O72− anions is influenced by the structure of the second network when the first network was SN20 cryogel. As can be seen, the lowest sorption capacity was found in the case of SN20 (300 mg Cr2O72−/g sorbent), even lower than that of SN5 (312 mg Cr2O72−/g sorbent), and the highest in the case of the composite DN20.2, i.e., when the second network was PEI25 (383 mg Cr2O72−/g sorbent). The difference between the sorption capacity of DN20.2 and DN20.3 (364.6 mg Cr2O72−/g sorbent) is not so high and could be associated with the difference in the molar mass of PEI used as the third network. As can be observed, the experimental data were also the best fitted by the Sips isotherm model.
Table 5 presents the isotherm parameters corresponding to the three TN composites derived from single-network SN20, the last network being the same for all composites (PEI18, 10%, Table 1). The highest sorption capacity was found in the case of composite TN20.3, while the sorption capacity of TN20.1 and TN20.2 was almost the same (379 and 380 mg Cr2O72−/g sorbent, respectively).
By comparing the values of the sorption capacity of Cr2O72− anions onto the single-network and composite cryogels we can conclude that the highest sorption capacity could be developed in the case of the composite cryogel TN5.2, i.e., when the first network was SN5, and the last network was PDMAEMA (Table 3). Figure 6d presents the optical images of SN5, SN20, DN20.2 and TN20.3 after their loading with Cr2O72− anions, at equilibrium. As can be observed, all sponges display a uniform intensity of color, which supports a uniform distribution of oxyanions inside the sorbents, a qualitative test which indicates the high affinity of these cryogels for Cr2O72− anions.
The experimental isotherms for the sorption of H2PO4 ions onto some novel DN and TN composite sponges are presented in Figure 6e (DN20.1 and DN20.2) and Figure 6f (TN20.1, TN20.2, TN5.1 and TN 5.2), respectively, and the isotherm parameters obtained by fitting the Langmuir, Freundlich and Sips isotherm models are given in Table 6. As shown in Table 6, the structure of the second network induced a significant difference between the values of the sorption capacity toward H2PO4 ions. Thus, the values of qm found in the case of DN20.2 as a sorbent (the second network being PEI25, Table 1) were much higher than those found for DN20.1 (with PDMAEMA as the second network), both experimental values and calculated by fitting Langmuir and Sips isotherm models. This difference could be attributed to the higher number of amino groups in PEI than in PDMAEMA. A consistent increase in the sorption capacity occurred when the third network was constructed (PEI18 for both TN20.1 and TN20.2). It can be also observed that the TN5.1 and TN5.2 sponges, having as the first matrix SN5 cryogel, display the highest values of qm, in agreement with the values obtained when the adsorption of Cr2O72− anions was investigated (Table 3).
The selectivity of some sorbents for Cr2O72− and H2PO4 anions, in binary mixtures, was investigated, the results being presented in Table S9. It is obvious that all sorbents prefer Cr2O72− anions, with the values of the selectivity coefficient, evaluated with Equation (6), increasing from 1.19 (SN5) to 2.77 (TN5.2) and from 1.14 (SN20) to 2.51 (TN20.3).
The maximum sorption capacity of the best multi-network sponges, prepared in this work, against Cr2O72− and H2PO4 anions is compared in Table S10 with data from the literature. As can be seen from Table S10, the uptake of the two oxyanions on the novel composite cryogels was comparable or even higher than the maximum sorption capacity of other sorbents.

3.2.3. Reusability

Sustainability of the novel composite sorbents is an essential feature for their applicability. Therefore, the level of preservation of the sorption capacity of the two SN sponges (SN5 and SN20), two DN composites (DN20.1 and DN20.2) and two TN composites (TN20.3 and TN5.2) toward Cr2O72− and H2PO4 anions is presented in Figure 7a,b, respectively. Comparing the sorption capacity toward Cr2O72− anions in the first cycle with that found after the fifth cycle, the loss was around 7%, 6% and 4% in the case of SN, DN and TN composite cryogels, respectively. The loss of the sorption capacity was slightly higher when H2PO4 anions were adsorbed, the decrease being 8.14%, 6.62%, 7.75%, 6.21%, 6.59% and 4.3% when the sorbent was SN20, SN5, DN20.1, DN20.3, TN20.3 and TN5.2, respectively. The preservation of the sorption capacity for both Cr2O72− and H2PO4 anions of the cationic composite sponges investigated in this work supports their potential as sorbents for the removal of two of the most harmful pollutants present in insufficiently treated wastewaters.
The increase in the sustainability with the increase in the network numbers is obvious for both oxyanions (TN compared with DN sponges).

4. Conclusions

Exclusive cationic composite DN and TN sponges, with adequate sustainability in the removal of Cr2O72− and H2PO4 oxyanions, were developed in this work, starting from self-healing SN sponges based on CS. PEI and PDMAEMA were used as synthetic polycations in the construction of the second and third networks. The properties of the composite sponges were adjusted by the cross-linking degree of the first network (5 or 20 mole% GA) and by the order of the successive networks of PEI and PDMAEMA. The sorption data were best fitted by the PSO kinetic model, indicating that the sorption mechanism was mainly controlled by chemisorption, irrespective of the structure and number of networks, while the experimental isotherms were best described by the Sips isotherm model. The benefits of the multi-network cationic sponges in the sorption of hazardous oxyanions include the monotonous increase in the sorption capacity of the composites with the increase in the number of networks. Starting from SN20 as the first network, the maximum sorption capacity calculated by the Sips isotherm model increased from 298 mg Cr2O72−/g SN20 to 366 mg Cr2O72−/g DN20.3, and to 420 mg Cr2O72−/g TN20.3. When SN5 was the first network, the increase in the sorption capacity was in the following order: 307 mg Cr2O72−/g SN5, 332 mg Cr2O72−/g DN5 and 439 mg Cr2O72−/g TN5.2. The selectivity coefficient for Cr2O72− anions, in binary systems, increased with the increase in the network number for both series of cationic composite sponges. This new strategy may provide a universal approach to fabricate multi-network cryogels, based on natural polysaccharides as the first network, and two synthetic polycations (PEI and PDMAEMA) endowed with superior mechanical properties, a high level of recyclability and versatile functions.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/polym15040885/s1, Figure S1: FTIR spectra of SN5, DN5 and TN5.2 composites (sample codes are from Table 1); Figure S2: FTIR spectra of DN20.3 and TN20.3 composite sponges (sample codes are from Table 1); Table S1: Values of the average pore diameters and pore wall thicknesses of composite cryogels; Table S2: Elemental analysis given by EDX spectra of SN5, SN20 and some DN and TN composite cryogels (sample codes are from Table 1); Table S3: Swelling ratio (SR) and equilibrium water content (EWC) of the SN, DN and TN cryogels; Table S4: Values of the compressive elastic modulus for single-network cryogels as a function of number of compression cycles; Table S5: Kinetic parameters for the adsorption of Cr2O72− anions onto multi-network composite cryogels constructed onto SN5 cryogel as the first network; Table S6: Kinetic parameters for the adsorption of Cr2O72− anions onto SN20 and DN composite cryogels having SN20 as the first network; Table S7: Kinetic parameters for the adsorption of Cr2O72− anions onto TN composite cryogels constructed onto SN20 cryogels; Table S8: Kinetic parameters for the adsorption of H2PO4 anions onto multi-network composite cryogels; Table S9: Selectivity coefficients for the sorption of oxyanions in binary systems; Table S10: Comparative results for the sorption of Cr2O72− and H2PO4 anions by multi-network cryogels and by different sorbents from the literature.

Author Contributions

Conceptualization, E.S.D.; methodology, E.S.D., D.H. and M.V.D.; software, E.S.D. and D.H.; validation, E.S.D., D.H. and M.V.D.; investigation, E.S.D., D.H. and M.V.D.; resources, E.S.D. and D.H.; writing—original draft preparation, E.S.D.; writing—review and editing, M.V.D.; supervision, E.S.D. All authors have read and agreed to the published version of the manuscript.

Funding

This research was supported by a grant of the Ministry of Research, Innovation and Digitization, CNCS/CCCDI—UEFISCDI, project number PN-III-P1-1.1-TE-2021-0771.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Bucatariu, F.; Teodosiu, C.; Morosanu, I.; Fighir, D.; Ciobanu, R.; Petrila, L.M.; Mihai, M. An overview on composite sorbents based on polyelectrolytes used in advanced wastewater treatment. Polymers 2021, 13, 3963. [Google Scholar] [CrossRef] [PubMed]
  2. Rahman, M.L.; Fui, C.J.; Ting, T.X.; Sarjadi, M.S.; Arshad, S.E.; Musta, B. Polymer ligands derived from iute fiber for heavy metal removal from electroplating wastewater. Polymers 2020, 12, 2521. [Google Scholar] [CrossRef]
  3. Zaharia, M.M.; Bucatariu, F.; Vasiliu, A.L.; Mihai, M. Stable and reusable acrylic ion exchangers. From HMIs highly polluted tailing pond to safe and clean water. Chemosphere 2022, 304, 185383. [Google Scholar] [CrossRef]
  4. Iqbal, S.; Javed, M.; Bahadur, A.; Qamar, M.A.; Ahmad, M.; Shoaib, M.; Raheel, M.; Ahmad, N.; Akbar, M.B.; Li, H. Controlled synthesis of Ag-doped CuO nanoparticles as a core with poly(acrylic acid) microgel shell for efficient removal of methylene blue under visible light. J. Mater. Sci. Mater. Electron. 2020, 31, 8423–8435. [Google Scholar] [CrossRef]
  5. Kuang, C.; Tan, P.; Bahadur, A.; Iqbal, S.; Javed, M.; Qamar, M.A.; Fayyaz, M.; Liu, G.; Alzahrani, O.M.; Alzahrani, E.; et al. Dye degradation study by incorporating Cu-doped ZnO photocatalyst into polyacrylamide microgel. J. Mater. Sci. Mater. Electron. 2022, 33, 9930–9940. [Google Scholar] [CrossRef]
  6. Pakade, V.E.; Tavengwa, N.T.; Madikizela, L.M. Recent advances in hexavalent chromium removal from aqueous solutions by adsorptive methods. RSC Adv. 2019, 9, 26142–26164. [Google Scholar] [CrossRef]
  7. Ghiorghita, C.A.; Dinu, M.V.; Lazar, M.M.; Dragan, E.S. Polysaccharide-based composite hydrogels as sustainable materials for removal of pollutants from wastewaters. Molecules 2022, 27, 8574. [Google Scholar] [CrossRef] [PubMed]
  8. Pehlivan, E.; Cetin, S. Sorption of Cr(VI) ions on two Lewatit-anion exchange resins and their quantitative determination using UV-visible spectrophotometer. J. Hazard. Mater. 2009, 163, 448–453. [Google Scholar] [CrossRef] [PubMed]
  9. Markovic, B.M.; Stefanovic, I.S.; Hercigonja, R.V.; Pergal, M.V.; Markovic, J.P.; Onjia, A.E.; Nastasovic, A.B. Novel hexamethylene diamine-functionalized macroporous copolymer for chromium removal from aqueous solutions. Polym. Int. 2017, 66, 679–689. [Google Scholar] [CrossRef]
  10. Zang, Y.; Yue, Q.; Kan, Y.; Zhang, L.; Gao, B. Research on adsorption of Cr(VI) by poly-epichlorohydrin-dimethylamine (EPIDMA) modified weakly basic anion exchange resin D301. Ecotoxicol. Environ. Saf. 2018, 161, 467–473. [Google Scholar] [CrossRef]
  11. Korak, J.A.; Huggins, R.; Arias-Paic, M. Regeneration of pilot-scale ion exchange columns for hexavalent chromium removal. Water Res. 2017, 118, 141–151. [Google Scholar] [CrossRef]
  12. Wang, X.; Wu, C.; Tian, L.; Li, G.; Zhang, X.; Lei, F.; Qu, J.; Liu, P. Cationic polymer chain tethered on the pore-wall of 3-D ordered macroporous resin for the removal of hexavalent chromium from aqueous solution. React. Funct. Polym. 2015, 95, 55–61. [Google Scholar] [CrossRef]
  13. Hayashi, N.; Chen, J.; Seko, N. Nitrogen-containing fabric adsorbents prepared by radiation grafting for removal of chromium from wastewater. Polymers 2018, 10, 744. [Google Scholar] [CrossRef] [PubMed]
  14. Dragan, E.S.; Humelnicu, D.; Dinu, M.V.; Romeo Iulian Olariu, R.I. Kinetics, equilibrium modeling, and thermodynamics on removal of Cr(VI) ions from aqueous solution using novel composites with strong base anion exchanger microspheres embedded into chitosan/poly(vinyl amine) cryogels. Chem. Eng. J. 2017, 330, 675–691. [Google Scholar] [CrossRef]
  15. Li, K.; Li, P.; Cai, J.; Xiao, S.; Yang, H.; Li, A. Efficient adsorption of both methyl orange and chromium from their aqueous mixtures using a quaternary ammonium salt modified chitosan magnetic composite adsorbent. Chemosphere 2016, 154, 310–318. [Google Scholar] [CrossRef]
  16. Khalil, T.E.; Elhusseiny, A.F.; El-dissouky, A.; Ibrahim, N.M. Functionalized chitosan nanocomposites for removal of toxic Cr (VI) from aqueous solution. React. Funct. Polym. 2020, 146, 104407. [Google Scholar] [CrossRef]
  17. Du, M.; Zhang, Y.; Wang, Z.; Lv, M.; Tang, A.; Yu, Y.; Qu, X.; Chen, Z.; Wen, Q.; Li, A. Insight into the synthesis and adsorption mechanism of adsorbents for efficient phosphate removal: Exploration from synthesis to modification. Chem. Eng. J. 2022, 442, 136147. [Google Scholar] [CrossRef]
  18. Shen, Z.; Dong, X.; Shi, J.; Ma, Y.; Liu, D.; Fan, J. Simultaneous removal of nitrate/phosphate with bimetallic nanoparticles of Fe coupled with copper or nickel supported on chelating resin. Environ. Sci. Pollut. Res. 2019, 26, 16568–16576. [Google Scholar] [CrossRef]
  19. Bui, T.H.; Hong, S.P.; Yoon, J. Development of nanoscale zirconium molybdate embedded anion exchange resin for selective removal of phosphate. Water Res. 2018, 134, 22–31. [Google Scholar] [CrossRef]
  20. Wiriyathamcharoen, S.; Sarkar, S.; Jiemvarangkul, P.; Nguyen, T.T.; Klysubun, W.; Padungthon, S. Synthesis optimization of hybrid anion exchanger containing triethylamine functional groups and hydrated Fe(III) oxide nanoparticles for simultaneous nitrate and phosphate removal. Chem. Eng. J. 2020, 381, 122671. [Google Scholar] [CrossRef]
  21. Du, J.; Dong, Z.; Yang, X.; Zhao, L. Radiation grafting of dimethylaminoethyl methacrylate on cotton linter and subsequent quaternization as new eco-friendly adsorbent for phosphate removal. Environ. Sci. Pollut. Res. 2020, 27, 24558–24567. [Google Scholar] [CrossRef] [PubMed]
  22. Wan, J.; Zhu, C.; Hu, J.; Zhang, T.C.; Richter-Egger, D.; Feng, X.; Zhou, A.; Tao, T. Zirconium-loaded magnetic interpenetrating network chitosan/poly(vinyl alcohol) hydrogels for phosphorus recovery from the aquatic environment. Appl. Surf. Sci. 2017, 423, 484–491. [Google Scholar] [CrossRef]
  23. Wang, J.; Wei, J. Facile synthesis of Zr(IV) crosslinked carboxymethyl cellulose/carboxymethyl chitosan hydrogel using PEG as pore-forming agent for enhanced phosphate removal. Int. J. Biol. Macromol. 2021, 176, 558–566. [Google Scholar] [CrossRef] [PubMed]
  24. Luo, H.; Zeng, X.; Liao, P.; Rong, H.; Zhang, T.C.; Zhang, Z.J.; Meng, X. Phosphorus removal and recovery from water with macroporous bead adsorbent constituted of alginate-Zr4+ and PNIPAM-interpenetrated networks. Int. J. Biol. Macromol. 2019, 126, 1133–1144. [Google Scholar] [CrossRef] [PubMed]
  25. Zhang, B.; Chen, N.; Feng, C.; Zhang, Z. Adsorption for phosphate by crosslinked/non-crosslinked-chitosan-Fe(III) complex sorbents: Characteristic and mechanism. Chem. Eng. J. 2018, 353, 361–372. [Google Scholar] [CrossRef]
  26. Zeng, H.; Sun, S.; Xu, K.; Zhao, W.; Hao, R.; Zhang, J.; Li, D. Iron-loaded magnetic alginate-chitosan double-gel interpenetrated porous beads for phosphate removal from water: Preparation, adsorption behavior and pH stability. React. Funct. Polym. 2022, 177, 105328. [Google Scholar] [CrossRef]
  27. Jia, Z.; Zeng, W.; Xu, H.; Li, S.; Peng, Y. Adsorption removal and reuse of phosphate from wastewater using a novel adsorbent of lanthanum-modified platanus biochar. Process Saf. Environ. Prot. 2020, 140, 221–232. [Google Scholar] [CrossRef]
  28. Liu, B.; Yu, Y.; Han, Q.; Lou, S.; Zhang, L.; Zhang, W. Fast and efficient phosphate removal on lanthanum-chitosan composite synthesized by controlling the amount of cross-linking agent. Int. J. Biol. Macromol. 2020, 157, 247–258. [Google Scholar] [CrossRef]
  29. Yang, Z.; Hou, J.; Pan, Z.; Wu, M.; Zhang, M.; Yin, X.; Wu, J.; Miao, L.; Liu, Q. A novel La(OH)3 decorated co-graft tannin and polyethyleneimine co-coating magnetic adsorbent for effective and selective phosphate removal from natural water and real wastewater. J. Clean. Prod. 2022, 369, 133345. [Google Scholar] [CrossRef]
  30. Malakhova, I.; Privar, Y.; Parotkina, Y.; Eliseikina, M.; Golikov, A.; Skatova, A.; Bratskaya, S. Supermacroporous monoliths based on polyethyleneimine: Fabrication and sorption properties under static and dynamic conditions. J. Environ. Chem. Eng. 2020, 8, 104395. [Google Scholar] [CrossRef]
  31. Huang, H.; Ren, D.; Qu, J. pH and temperature-responsive POSS-based poly(2-(dimethylamino) ethyl methacrylate) for highly efficient Cr(VI) adsorption. Colloid Polym. Sci. 2020, 298, 1515–1521. [Google Scholar] [CrossRef]
  32. Dragan, E.S. Advances in interpenetrating polymer network hydrogels and their applications. Pure Appl. Chem. 2014, 86, 1707–1721. [Google Scholar] [CrossRef]
  33. Dragan, E.S.; Humelnicu, D.; Dinu, M.V. Development of chitosan-poly(ethyleneimine) based double network cryogels and their application as superadsorbents for phosphate. Carbohydr. Polym. 2019, 210, 17–25. [Google Scholar] [CrossRef] [PubMed]
  34. Dragan, E.S.; Humelnicu, D.; Dinu, M.V. Designing smart triple-network cationic cryogels with outstanding efficiency and selectivity for deep cleaning of phosphate. Chem. Eng. J. 2021, 426, 131411. [Google Scholar] [CrossRef]
  35. Sedlačik, T.; Nanoyama, T.; Guo, H.; Kiyama, R.; Nakajima, T.; Takeda, Y.; Kurokawa, T.; Gong, J.P. Preparation of tough double and triple network supermacroporous hydrogels through repeated cryogelation. Chem. Mater. 2020, 32, 8576–8586. [Google Scholar] [CrossRef]
  36. Zou, W.; Chen, Y.; Zhang, X.; Li, J.; Sun, L.; Gui, Z.; Du, B.; Chen, S. Cytocompatibility chitosan based multi-network hydrogels with antimicrobial, cell anti-adhesive and mechanical properties. Carbohydr. Polym. 2018, 202, 246–257. [Google Scholar] [CrossRef]
  37. Yu, F.; Yang, P.; Yang, Z.; Zhang, X.; Ma, J. Double-network hydrogel adsorbents for environmental applications. Chem. Eng. J. 2021, 426, 131900. [Google Scholar] [CrossRef]
  38. Li, L.; Wu, P.; Yu, F.; Ma, J. Double network hydrogels for energy/environmental applications: Challenges and opportunities. J. Mater. Chem. A 2022, 10, 9215–9247. [Google Scholar] [CrossRef]
  39. Bercea, M. Bioinspired hydrogels as platforms for life-science applications: Challenges and opportunities. Polymers 2022, 14, 2365. [Google Scholar] [CrossRef]
  40. Gamzazade, A.I.; Shimac, V.M.; Skljar, A.M.; Stykova, E.V.; Pavlova, S.A.; Rogozin, S. Investigation of the hydrodynamic properties of chitosan solutions. Acta Polym. 1985, 36, 420–424. [Google Scholar] [CrossRef]
  41. Venkataraman, R.; Das, G.; Singh, S.R.; Pathak, L.C.; Ghosh, R.N.; Venkataraman, B.; Krishnamurthy, R. Study on influence of porosity, pore size, spatial and topological distribution of pores on microhardness of plasma sprayed ceramic coatings. Mater. Sci. Eng. A 2007, 445–446, 269–274. [Google Scholar] [CrossRef]
  42. Qi, X.; Chen, M.; Qian, Y.; Liu, M.; Li, Z.; Shen, L.; Qin, T.; Zhao, S.; Zeng, Q.; Shen, J. Construction of macroporous salecan polysaccharide-based adsorbents for wastewater remediation. Int. J. Biol. Macromol. 2019, 132, 429–438. [Google Scholar] [CrossRef]
  43. Ding, N.; Cai, X.; Zhang, P.; Dong, S.; Du, B.; Nie, J.; Yu, P. Mimicking the Mechanical Properties of Cartilage Using Ionic- and Hydrogen-Bond Cross-Linked Hydrogels with a High Equilibrium Water Content above 70%. ACS Appl. Polym. Mater. 2021, 3, 2709–2721. [Google Scholar] [CrossRef]
  44. Hu, X.; Wang, Y.; Zhang, L.; Xu, M. Design of a novel polysaccharide-based cryogel using triallyl cyanurate as crosslinker for cell adhesion and proliferation. Int. J. Biol. Macromol. 2019, 126, 221–228. [Google Scholar] [CrossRef] [PubMed]
  45. Dragan, E.S.; Dinu, M.V.; Ghiorghita, C.A. Chitosan-based polyelectrolyte complex cryogels with elasticity, toughness and delivery of curcumin engineered by polyions pair and cryostructuration steps. Gels 2022, 8, 240. [Google Scholar] [CrossRef] [PubMed]
  46. Dragan, E.S.; Ghiorghita, C.A.; Dinu, M.V.; Duceac, I.A.; Coseri, S. Fabrication of self-antibacterial chitosan/oxidized starch polyelectrolyte complex sponges for controlled delivery of curcumin. Food Hydrocolloids 2023, 135, 108147. [Google Scholar] [CrossRef]
  47. Duranoglu, D.; Trochimczuk, A.W.; Beker, U. Kinetics and thermodynamics of hexavalent chromium adsorption onto activated carbon derived from acrylonitrile-divinylbenzene copolymer. Chem. Eng. J. 2012, 187, 193–202. [Google Scholar] [CrossRef]
  48. Nagul, E.A.; McKelvie, I.D.; Worsfold, P.; Kolev, S.D. The molybdenum blue reaction for the determination of orthophosphate revisited: Opening the black box. Anal. Chim. Acta 2015, 890, 60–82. [Google Scholar] [CrossRef]
  49. Yuan, Q.; Shah, J.; Hein, S.; Misra, R.D.K. Controlled and extended drug release behavior of chitosan-based nanoparticle carrier. Acta Biomater. 2010, 6, 1140–1148. [Google Scholar] [CrossRef]
  50. Zhang, J.; Chen, N.; Tang, Z.; Yu, Y.; Hu, Q.; Feng, C. Adsorption of fluoride from aqueous solutions onto Fe-impregnated chitosan and mechanism study. Phys. Chem. Chem. Phys. 2015, 17, 12041. [Google Scholar] [CrossRef]
  51. Coates, J. Interpretation of Infrared Spectra. A practical approach. In Encyclopedia of Analytical Chemistry; Meyers, R.A., Ed.; John Wiley & Sons Ltd.: Chichester, UK, 2000; pp. 10815–10837. [Google Scholar]
  52. Wei, W.; Hu, X.; Qi, X.; Yu, H.; Liu, Y.; Li, J.; Zhang, J.; Dong, W. A novel thermo-responsive hydrogel based on salecan and poly(N-isopropylacrylamide): Synthesis and characterization. Colloids Surf. B Biointerfaces 2015, 125, 1–11. [Google Scholar] [CrossRef] [PubMed]
  53. Hu, X.; Feng, L.; Xie, A.; Wei, W.; Wang, S.; Zhang, J.; Dong, W. Synthesis and characterization of a novel hydrogel: Salecan/polyacrylamide semi-IPN hydrogel with a desirable pore structure. J. Mater. Chem. B 2014, 2, 3646–3658. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Synthesis strategy of DN and TN composite cryogels starting from the single network of CS cross-linked with 20 mole% GA.
Figure 1. Synthesis strategy of DN and TN composite cryogels starting from the single network of CS cross-linked with 20 mole% GA.
Polymers 15 00885 g001
Figure 2. FTIR spectra of SN20, DN20.2 and TN20.2 (Table 1) (up) and SEM images of SN5, DN5, TN5.1, SN20, DN20.2 and TN20.2 (Table 1) (down) with scale bar of 200 µm and magnification of 500×.
Figure 2. FTIR spectra of SN20, DN20.2 and TN20.2 (Table 1) (up) and SEM images of SN5, DN5, TN5.1, SN20, DN20.2 and TN20.2 (Table 1) (down) with scale bar of 200 µm and magnification of 500×.
Polymers 15 00885 g002
Figure 3. The mechanical properties of single-network cryogels as a function of number of compression cycles. Stress–strain profiles of SN5 (a) and SN20 (b) cryogels (the insets of (a,b) present the linear dependence of stress–strain curves used for the calculation of compression elastic moduli). Maximum sustained compression (black column bars) and compressive strength (red column bars) for SN5 (c) and SN20 (d) cryogels.
Figure 3. The mechanical properties of single-network cryogels as a function of number of compression cycles. Stress–strain profiles of SN5 (a) and SN20 (b) cryogels (the insets of (a,b) present the linear dependence of stress–strain curves used for the calculation of compression elastic moduli). Maximum sustained compression (black column bars) and compressive strength (red column bars) for SN5 (c) and SN20 (d) cryogels.
Polymers 15 00885 g003
Figure 4. The mechanical properties of DN and TN network cryogels. Stress–strain profiles of DN and TN obtained starting from SN5 (a) and SN20 (b) cryogels (the inset of (a) presents the linear dependence of stress–strain curves used for the calculation of compression elastic moduli of DN5 and TN5 cryogels). (c) Linear dependence of stress–strain curves from which the compression elastic moduli of the DN20 and TN20 cryogels were determined.
Figure 4. The mechanical properties of DN and TN network cryogels. Stress–strain profiles of DN and TN obtained starting from SN5 (a) and SN20 (b) cryogels (the inset of (a) presents the linear dependence of stress–strain curves used for the calculation of compression elastic moduli of DN5 and TN5 cryogels). (c) Linear dependence of stress–strain curves from which the compression elastic moduli of the DN20 and TN20 cryogels were determined.
Polymers 15 00885 g004
Figure 5. Comparative sorption kinetics of Cr2O72− anions onto SN, DN and TN composite sorbents (ac). Sorption kinetics of H2PO4 onto DN and TN composite sorbents (d); sorbent dose = 7.5 mg, Vsol = 10 mL, pH = 3 for SN and DN, and pH = 4 for TN; temp = 23 °C; Cin = 100 mg/L.
Figure 5. Comparative sorption kinetics of Cr2O72− anions onto SN, DN and TN composite sorbents (ac). Sorption kinetics of H2PO4 onto DN and TN composite sorbents (d); sorbent dose = 7.5 mg, Vsol = 10 mL, pH = 3 for SN and DN, and pH = 4 for TN; temp = 23 °C; Cin = 100 mg/L.
Polymers 15 00885 g005
Figure 6. (ac) Sorption isotherms of Cr2O72− anions onto SN, DN and TN cryogels; sorbent dose = 0.0075 mg; Vsol = 10 mL; temp. = 23 °C; pH = 3 for SN and DN, and pH = 4 for TN; contact time = 24 h. (d) Optical images of some cryogels after their loading with Cr(VI). Sorption isotherms toward H2PO4 onto DN (e) and TN (f) composite cryogels.
Figure 6. (ac) Sorption isotherms of Cr2O72− anions onto SN, DN and TN cryogels; sorbent dose = 0.0075 mg; Vsol = 10 mL; temp. = 23 °C; pH = 3 for SN and DN, and pH = 4 for TN; contact time = 24 h. (d) Optical images of some cryogels after their loading with Cr(VI). Sorption isotherms toward H2PO4 onto DN (e) and TN (f) composite cryogels.
Polymers 15 00885 g006
Figure 7. Sorption capacity of Cr2O72− (a) and H2PO4 (b) oxyanions onto SN, DN and TN cryogels as a function of the adsorption/desorption cycle number.
Figure 7. Sorption capacity of Cr2O72− (a) and H2PO4 (b) oxyanions onto SN, DN and TN cryogels as a function of the adsorption/desorption cycle number.
Polymers 15 00885 g007
Table 1. Double-network (DN) and triple-network (TN) cryogels prepared and used as sorbents for the removal of Cr2O72− and H2PO4 oxyanions.
Table 1. Double-network (DN) and triple-network (TN) cryogels prepared and used as sorbents for the removal of Cr2O72− and H2PO4 oxyanions.
Cryogel Name1st Network2nd Network3rd Network
Name *GA, Mole %NameConc. wt.%NameConc. wt.%
SN5CS5----
DN5CS5PEI1815--
TN5.1CS5PEI1815PEI1810
TN5.2CS5PEI1815PDMAEMA10
SN20CS20----
DN20.1CS20PDMAEMA10--
DN20.2CS20PEI2515--
DN20.3CS20PEI1815--
TN20.1CS20PDMAEMA10PEI1810
TN20.2CS20PEI2515PEI1810
TN20.3CS20PEI1815PEI1810
* CS concentration was 2 wt.% in all syntheses.
Table 2. Compressive elastic modulus, compressive nominal stress and maximum strain of the DN and TN composite cryogels.
Table 2. Compressive elastic modulus, compressive nominal stress and maximum strain of the DN and TN composite cryogels.
Sample CodeCompressive Elastic Modulus, kPaR2Compressive Nominal Stress, kPaStrain%
DN540.370.98531.3852.90
TN5.161.570.995538.2069.02
TN5.242.510.99148.0755.63
DN20.198.010.998370.4976.30
DN20.2126.260.99714.4513.30
DN20.3115.160.99924.7531.18
TN20.1163.990.984316.5268.37
TN20.235.150.999282.3576.15
TN20.399.230.99911.3621.91
Table 3. Isotherm parameters for the sorption of Cr2O72− anions onto SN5 cryogels and derived composite sorbents.
Table 3. Isotherm parameters for the sorption of Cr2O72− anions onto SN5 cryogels and derived composite sorbents.
Isotherm ParametersSN5DN5TN5.1TN5.2
qm,exp, mg g−1312336410437
Langmuir model: q e = q m K L C e 1 + K L C e
qm, mg g−1358.03359.13391.76429.5
KL, L mg−10.02160.0711.8681.211
R20.89340.94780.95790.9889
χ216308971074319
Freundlich model: q e = K F C e N
KF, mg1−1/n.L1/n.g−150.7791.82181.33196
1/n0.2980.21880.14410.1418
R20/74010.76880.86510.8831
χ23974397634473392
Sips model: q e = q m a S C e N 1 + a S C e N
qm, mg g−1306.9332.2413.7439.32
aS6.146 × 10−50.00781.11011.0661
1/n2.862.0440.67280.7863
R20.99140.99510.96710.9941
χ213085840173
Table 4. Isotherm parameters for the sorption of Cr2O72− anions onto SN20 cryogels and derived composite sorbents.
Table 4. Isotherm parameters for the sorption of Cr2O72− anions onto SN20 cryogels and derived composite sorbents.
Isotherm ParametersSN20DN20.1DN20.2DN20.3
qm,exp, mg g−1300322383364.6
Langmuir model: q e = q m K L C e 1 + K L C e
qm, mg g−1352.64356394.63383.4
KL, L mg−10.01770.03540.20140.0799
R20.87480.95480.93350.9811
χ218306581496376
Freundlich model: q e = K F C e N
KF, mg1−1/n.L1/n.g−144.0867.49124.499.21
1/n0.31380.260.19350.2206
R20.72090.78910.78400.8238
χ24078333048573510
Sips model: q e = q m a S C e N 1 + a S C e N
qm, mg g−1297.75324.6381.6366.05
aS7.515 × 10−60.00460.03080.0381
1/n3.291.751.921.378
R20.99780.99580.98110.9901
χ23367425198
Table 5. Isotherm parameters for the sorption of Cr2O72− anions onto TN composite cryogels derived from SN20.
Table 5. Isotherm parameters for the sorption of Cr2O72− anions onto TN composite cryogels derived from SN20.
Isotherm ParametersTN20.1TN20.2TN20.3
qm,exp, mg g−1379380426.7
Langmuir model: q e = q m K L C e 1 + K L C e
qm, mg g−1377.6376.1405.5
KL, L mg−10.30340.42453.552
R20.98470.98710.9718
χ2330280770
Freundlich model: q e = K F C e N
KF, mg1−1/n.L1/n.g−1134.9143.6199
1/n0.17830.16890.1345
R20.84410.84940.871
χ2335232663530
Sips model: q e = q m a S C e N 1 + a S C e N
qm, mg g−1375.41377.4420
aS0.29770.42561.947
1/n1.0460.9720.7168
R20.98310.98570.9771
χ2363309628
Table 6. Isotherm parameters for the sorption of H2PO4 anions onto DN and TN composite cryogels.
Table 6. Isotherm parameters for the sorption of H2PO4 anions onto DN and TN composite cryogels.
Isotherm ParametersDN20.1DN20.2TN20.1TN20.2TN5.1TN5.2
qe,exp, mg/g295.7367.82373390.4405.3422
Langmuir model: q e = q m K L C e 1 + K L C e
qm, mg g−1331.64397.65378.14376.79382.67407.62
KL, L mg−10.02540.10280.19380.80011.2762.262
R20.96240.95510.97130.95510.94680.9552
χ2492900596102412921210
Freundlich model: q e = K F C e N
KF, mg1−1/n.L1/n.g−152.6105123.18157.1167.65194.18
1/n0.2840.21250.18970.15810.1530.137
R20.81160.81090.82050.85410.86990.8593
χ2246237953728331831593805
Sips model: q e = q m a S C e N 1 + a S C e N
qm, mg g−1297.47365.58364.83391.1408.93422.45
aS0.003010.06740.14050.67860.81781.421
1/n1.7171.2791.3570.76880.65390.7056
R20.99480.95650.97560.95570.95550.9584
χ268872507100610791125
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Dragan, E.S.; Humelnicu, D.; Dinu, M.V. Sustainable Multi-Network Cationic Cryogels for High-Efficiency Removal of Hazardous Oxyanions from Aqueous Solutions. Polymers 2023, 15, 885. https://doi.org/10.3390/polym15040885

AMA Style

Dragan ES, Humelnicu D, Dinu MV. Sustainable Multi-Network Cationic Cryogels for High-Efficiency Removal of Hazardous Oxyanions from Aqueous Solutions. Polymers. 2023; 15(4):885. https://doi.org/10.3390/polym15040885

Chicago/Turabian Style

Dragan, Ecaterina Stela, Doina Humelnicu, and Maria Valentina Dinu. 2023. "Sustainable Multi-Network Cationic Cryogels for High-Efficiency Removal of Hazardous Oxyanions from Aqueous Solutions" Polymers 15, no. 4: 885. https://doi.org/10.3390/polym15040885

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop