Peer-Review Record

Magnetostriction Enhancement in Midrange Modulus Magnetorheological Elastomers for Sensor Applications

Micromachines 2023, 14(4), 767; https://doi.org/10.3390/mi14040767
by Muhammad Asyraf Tasin 1, Siti Aishah Abdul Aziz 2, Saiful Amri Mazlan 1,*, Mohd Aidy Faizal Johari 1, Nur Azmah Nordin 1, Shahir Yasin Mohd Yusuf 1, Seung-Bok Choi 3,4,* and Irfan Bahiuddin 5
Reviewer 1:
Reviewer 2:
Micromachines 2023, 14(4), 767; https://doi.org/10.3390/mi14040767
Submission received: 20 February 2023 / Revised: 23 March 2023 / Accepted: 23 March 2023 / Published: 29 March 2023
(This article belongs to the Special Issue Magnetic and Spin Devices, Volume II)

Round 1

Reviewer 1 Report

The MRE with a storage modulus above 300kPa has been analyzed in the manuscript, which shows the potential applications in the sensing area.

To make the manuscript understandable, there are some suggestions to the authors:

1. If the distribution of the CIP would affect the experiment results?

2. The accuracy of the proposed module for the sensing is not clear, please add such statement in the manuscript.

3. Compared with the Guan[1] method, the improvement is not outstanding, please address this issue in the revised manuscript  in detail.

Author Response

Please refer to the attached file.

Author Response File: Author Response.docx

Reviewer 2 Report

​The authors have studied in details the Magnetostriction in Midrange Modulus Magnetorheological Elastomers. The findings are interesting and scientifically proven. I recommend it for publication after addressing following points.

1. Please check the unit for density should be properly written e.g. line 155. 

2. Authos should desciribe the magnetostrction measurement process in detail and exaplin how it is differnent or advantageous  than the most commonly used strain gauge method.

Thanks and Regards

Author Response

Please refer to the attached file.

Author Response File: Author Response.docx

Round 2

Reviewer 1 Report

The response to the comment is sufficient enough for the reviewer.

Author Response

In fact, there is no more comment to be reflected as clearly written at the end of this sheet: The response to the comment is sufficient enough for the reviewer