Article

Analysis and Hardening of SEGR in Trench VDMOS with Termination Structure

1
School of Microelectronics and Communication Engineering, Chongqing University, Chongqing 400044, China
2
Science and Technology on Analog Integrated Circuit Laboratory, Chongqing 401332, China
*
Author to whom correspondence should be addressed.
Micromachines 2023, 14(3), 688; https://doi.org/10.3390/mi14030688
Submission received: 27 February 2023 / Revised: 12 March 2023 / Accepted: 13 March 2023 / Published: 20 March 2023
(This article belongs to the Special Issue Power Semiconductor Devices and Applications)

Abstract

:
Single-event gate-rupture (SEGR) in the trench vertical double-diffused power MOSFET (VDMOS) occurs at a critical bias voltage during heavy-ion experiments. Fault analysis demonstrates that the hot spot is located at the termination of the VDMOS, and the gate oxide in the termination region has been damaged. The SEGR-hardened termination with multiple implantation regions is proposed and simulated using the Sentaurus TCAD. The multiple implantation regions are introduced, leading to an increase in the distance between the gate oxide and the hole accumulation region, as well as a decrease in the resistivity of the hole conductive path. This approach is effective in reducing the electric field of the gate oxide to below the calculated critical field, and results in a lower electric field than the conventional termination.

1. Introduction

Trench vertical double-diffused power MOSFETs (VDMOS) are widely used in power management systems as ideal power switches for space radiation environments [1,2,3]. These devices will be exposed to energetic neutrons, protons, and heavy ions when used in space. Heavy ions can trigger single-event gate-rupture (SEGR) in devices, causing gate oxide damage and even device burnout. Under the heavy-ion strikes, a large number of electron–hole pairs are generated along the track, and the gate oxide will break down to produce a conductive path, leading to a serious failure.
SEGR was first reported by Fischer [4], and since then, many studies have been carried out on the mechanism of SEGR. Darwish et al. [5] proposed that the surface electric field is sufficiently high to cause SEGR and that increasing the thickness of the gate oxide is an effective method to avoid SEGR. Nichols et al. [6] proved that SEGR is sensitive to the temperature and the incident angle. Titus et al. [7,8,9,10,11] studied the impact of particle energy, the position of particle Bragg peak, and the particle type on SEGR using experimental and simulation methods. Lauenstein et al. [12] reported the effects of charge generated by heavy ions in the gate oxide layer, the drift layer, and the substrate layer on SEGR. Titus et al. [13] reviewed the mechanism of single-event burnout (SEB) and SEGR. Privat et al. [14] investigated the impact of the latent defects on SEGR during switching operations. Recently, more studies have focused on the SEGR hardening technologies, such as the thicker gate oxide at the trench bottom proposed by Ttius et al. [3] and Darwish et al. [15], the W-shaped gate dielectric proposed by [16], the high-k gate dielectric proposed by X. Wan et al. [17] and A. Javanainen et al. [18], the widened split gate proposed by Jiang Lu et al. [19], the super-junction power MOS proposed by Muthuseenu et al. [20], and so on. As we all know, the termination is an essential part for all VDMOS devices; however, many hardening guidelines focus on the cell region of the VDMOS. The hardening technology for the termination is of great importance.
In this paper, heavy-ion tests were performed on trench VDMOS with a VBR of 60 V. It was found that SEGR occurred in the termination and the gate oxide was damaged. The failure mechanism was analyzed using Sentaurus TCAD. The termination is more prone to SEGR than the cell, and thus, the SEGR-hardened termination with multiple implantation regions was proposed. It was shown to be an effective method to suppress SEGR and improve radiation reliability.

2. Device and Experiments

The cross-sectional SEM schematic photograph of the 60 V n-channel trench VDMOS is shown in Figure 1. The devices were manufactured using 0.35 μm process. The trench structure is formed by Si trench etching, oxide growth, and poly-silicon deposition. Specifically, the gate oxide is grown after the ion doping and drive-in process to improve its quality. Table 1 lists the main parameters of the device. Because of the trench structure, the trench VDMOS exhibits a smaller cell pitch of 1.5 μm and a higher drift doping concentration of 3 × 1016 cm−3. Therefore, the devices achieve a static on-state resistance of 15 mΩ and a continuous drain current of 35 A.
The trench VDMOS devices were irradiated using a 181Ta ions with a linear energy transfer (LET) of 80.28 MeV·mg−1·cm−2, which were normal to the surface of the device with a beam flux of 1 × 104 ions/cm2/s. When the total ion beam of 1 × 107 ions/cm2 was achieved, the beam was shuttered immediately following the detection of the gate and drain leakage currents. However, when the device failed, the experiment would be terminated in advance.
Figure 2 presents the basic test circuit for SEB and SEGR referring to the method 1080.1 in the MIL-STD-750-1 [21]. The gate resistor–capacitor network provides a low-pass filter to protect the gate oxide from switching transients. The drain resistor helps limit the current and voltage to prevent device failure from SEB. During the heavy-ion experiment, the drain–source voltage (VDS) was biased at 24 V or 48 V, the gate–source voltage (VGS) was biased at 0 V. The gate leakage current and the drain current were measured in real time.

3. Experimental Results and Analysis

Figure 3a and Figure 3b show the gate leakage current and the drain current curve at VDS = 24 V, VGS = 0 V and VDS = 48 V, VGS = 0 V, respectively. As is shown in Figure 3a, the gate leakage current and the drain current had little change. This indicates that the device would not exhibit SEB or SEGR at the VDS = 24 V and VGS = 0 V. However, in Figure 3b, the gate leakage current increased from below 1 nA to 1 μA and exceeded the upper limit value, while the drain current varied within 1 μA. It is obviously seen that the SEGR event had occurred. After the heavy-ion experiment, the device was measured again using the AgilentB1505A and the test results show that the gate oxide of the device had suffered damage.
In order to locate the failure point of the post-irradiated trench VDMOS more accurately, an emission microscopy (EMMI) with a wavelength range from 350 nm to 1100 nm was used to detect hot spots, as shown in Figure 4. In Figure 4a, one hot spot was detected, and it can be seen clearly under a microscope. The enlarged image of the hot spot was shown in Figure 4b. By comparing it with the trench device layout, it is obviously seen that the hot pot appeared in the termination region. The red dash frame in Figure 4b represents the cell region of the device. In addition, the location of the hot spot was cut by the focused ion beam (FIB), and then the FIB-cut cross section was scanned by the scanning electron microscope (SEM), as shown in Figure 5a, the red dash frame of which was magnified as shown in Figure 5b. From Figure 5b, it is obvious that the gate oxide in the termination region had been damaged. It can be further proven that the SEGR occurred. The failure of the post-irradiated trench was caused by the SEGR in the termination region.
To analyze the SEGR of the trench VDMOS clearly, Sentaurus TCAD simulations were performed on the trench VDMOS. The cross section of the cell and termination are shown in Figure 6a,b. The termination structure is the gate bus region used to transfer the gate signal in the cell region. The mobility model, Shockley–Read–Hall (SRH) recombination, Auger, and avalanche model were adopted in the simulation. The simulation models have been calibrated with the measured results. Figure 7 shows the simulated breakdown characteristic of the cell, which fits well with the experimental results. To mimic heavy-ion strikes, the HeavyIon model was used in simulations. The heavy ions with an LET of 80 MeV·mg−1·cm−2 were normally incident to the middle of the trench gate in the cell and termination structure. The Gaussian distribution was used in the HeavyIon model, with the radius and the length of heavy ions defined as 0.5 μm and 8 μm, respectively. The length of heavy ions was long enough to penetrate the whole drift region. The incident time of the heavy ion is 0.1 ns.
According to reference [22], the calculated critical breakdown electric field for the gate oxide is 3.76 × 106 V/cm under 181Ta ions for triggering the SEGR. Figure 8 shows the simulated electric field of gate oxide at the position of the maximum electric field in the cell and the termination at VDS = 40 V, VGS = 0 V. As shown in Figure 3, the highest electric field in the termination was much larger than that of the cell. Meanwhile, the highest electric field in the cell has not reached the critical electric breakdown field, but that in the termination has far exceeded it.
During the heavy-ions strike, a large number of electron–hole pairs are generated. The electrons are swept down to the drain substrate, while the holes move to the gate when the VGS is zero or negative and the VDS is positive. More accumulated holes at the bottom of the gate oxide lead to a higher electric field of the gate oxide. However, the moving path of the holes in the termination is much longer than that in the cell, therefore the holes in the termination are difficult to release, which results in a higher electric field of the gate oxide. Figure 9 shows the hole density distribution near the gate oxide in the cell and the termination at 100 ns. It proves that the hole density in the termination is much higher than that in the cell.

4. Hardening Design and Discussion

Figure 10 shows the cross section of the SEGR-hardened termination with multiple implantation regions of the bottom N-well region (BNW), the p-type sidewall region (SW), and the p-type extension layer (EL). The doping concentrations of BNW, SW, and EL are 5 × 1016 cm−3, 1 × 1018 cm−3, and 1 × 1019 cm−3, respectively. BNW increases the distance between the gate oxide and the hole accumulation region, which diminishes the induced electric field. Owing to the higher doping concentration of SW and EL, the resistivity of the holes’ conductive path can be obviously decreased to accelerate the holes’ release. Therefore, the accumulated holes induced by the heavy-ion strikes can be easily discharged, and the electric field of the gate oxide is decreased.
The simulated electric field of the gate oxide at the position of the maximum electric field in the conventional termination and the SEGR-hardened termination at VDS = 40 V, VGS = 0 V is shown in Figure 11. It can be seen that the maximum electric field has reduced from 4.78 MV/cm in the conventional termination to 1.39 MV/cm in the SEGR-hardened termination. This means that the SEGR technique is highly effective in restraining the increase in the electric field in the gate oxide.
Figure 12 shows the distribution of hole density over time of the conventional termination and the SEGR-hardened termination. It is clear that as the multiple implantation regions are introduced, the accumulated holes near gate oxide are fewer in the SEGR-hardened termination, leading to a lower electric field than the conventional termination and further ensuring the radiation reliability of the device.
To further demonstrate the improvement of SEGR hardening, the SEGR-triggering criteria for the conventional termination and the SEGR-hardened termination are investigated in detail. As shown in Figure 13, it is clear seen that when VGS is set as 0 V, the conventional termination does not trigger SEGR when VDS is 27 V and below, and when VDS is 28 V, SEGR occurs. Thus, the SEGR-triggering voltage (VSEGR) of the conventional termination is 28 V. The SEGR-hardened termination does not trigger SEGR when VDS is 60 V and below, which can be considered to be a safe operating area (SOA); we believe that the device will not exhibit SEGR at VGS = 0 V for 60 V trench VDMOS. Compared with the conventional termination, the SEGR-triggering critical voltage for the SEGR-hardened termination is improved by 114%.
The termination structure could affect the breakdown voltage of the trench VDMOS; therefore, the breakdown characteristics for the conventional termination and the SEGR-hardened termination are investigated, as is shown in Figure 14. With the introduction of multiple implantation regions for hardening, the BV is slightly decreased from 74 V to 63 V. However, compared to the low triggering voltage and failure consequences of SEGR, these small impacts of the hardening method are still acceptable.

5. Conclusions

In conclusion, single-event gate-rupture in trench VDMOS occurs under heavy-ions strike. With fault analysis demonstrating that the gate oxide in the termination has been damaged. The SEGR-hardened termination with multiple implantation regions of BNW, SW, and EL is proposed and simulated using Sentaurus TCAD. The multiple implantation regions result in a lower electric field in the gate oxide. Compared with the conventional termination, the SEGR-hardened termination has better radiation performance with the LET of 80.28 MeV·mg−1·cm−2.

Author Contributions

Conceptualization and Writing—Original draft, Y.W.; Software and Data curation, L.Q.; Software, T.L., H.W., Y.Y., J.T. and Z.C.; Supervision and Writing—Reviewing and Editing, S.H. All authors have read and agreed to the published version of the manuscript.

Funding

This work is in part by the National Natural Science Foundation of China under Grant 62174017, in part by the National Laboratory of Science and Technology on Analog Integrated Circuit under Grant 2021-JCJQ-LB-049-4, and in part by the Natural Science Foundation Project of CQ CSTC under Grant cstc2020jcyjmsxmX0243.

Data Availability Statement

Data are available on request due to restrictions, e.g., privacy or ethical.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Williams, R.K.; Darwish, M.N.; Blanchard, R.A.; Siemieniec, R.; Rutter, P.; Kawaguchi, Y. The trench power MOSFET: Part I—History, technology, and prospects. IEEE Trans. Electron Devices 2017, 64, 674–691. [Google Scholar] [CrossRef]
  2. Ma, L.; Amali, A.; Kiyawat, S.; Mirchandani, A.; He, D.; Thapar, N.; Sodhi, R.; Spring, K.; Kinzer, D. New trench MOSFET technology for DC-DC converter applications. In Proceedings of the ISPSD ‘03, 2003 IEEE 15th International Symposium on Power Semiconductor Devices and ICs, Cambridge, UK, 14–17 April 2003; pp. 354–357. [Google Scholar] [CrossRef]
  3. Titus, J.; Jamiolkowski, L.; Wheatley, C. Development of cosmic ray hardened power MOSFET’s. IEEE Trans. Nucl. Sci. 1989, 36, 2375–2382. [Google Scholar] [CrossRef]
  4. Fischer, T.A. Heavy-Ion-Induced, Gate-Rupture in Power MOSFETs. IEEE Trans. Nucl. Sci. 1987, 34, 1786–1791. [Google Scholar] [CrossRef]
  5. Darwish, M.; Shibib, M.; Pinto, M.; Titus, J. Single event gate rupture of power DMOS transistors. In Proceedings of the IEEE International Electron Devices Meeting, Washington, DC, USA, 5–8 December 1993; pp. 671–674. [Google Scholar] [CrossRef]
  6. Nichols, D.K.; Coss, J.R.; Mccarty, K.P. Single event gate rupture in commercial power MOSFETs. In Proceedings of the RADECS 93, Second European Conference on Radiation and its Effects on Components and Systems (Cat. No.93TH0616-3), Saint Malo, France, 13–16 September 1993; pp. 462–467. [Google Scholar] [CrossRef]
  7. Titus, J.; Wheatley, C.; Allenspach, M.; Schrimpf, R.; Burton, D.; Brews, J.; Galloway, K.; Pease, R. Influence of ion beam energy on SEGR failure thresholds of vertical power MOSFETs. IEEE Trans. Nucl. Sci. 1996, 43, 2938–2943. [Google Scholar] [CrossRef]
  8. Wheatley, T.; Wheatley, C.; Titus, J. Early lethal SEGR failures of VDMOSFETs considering nonuniformity in the rad-hard device distribution. IEEE Trans. Nucl. Sci. 2001, 48, 2217–2221. [Google Scholar] [CrossRef]
  9. Titus, J.; Wheatley, C.; Gillberg, J.; Burton, D. A study of ion energy and its effects upon an SEGR-hardened stripe-cell MOSFET technology [space-based systems]. IEEE Trans. Nucl. Sci. 2001, 48, 1879–1884. [Google Scholar] [CrossRef]
  10. Liu, S.; Boden, M.; Cao, H.; Sanchez, E.; Titus, J.L. Evaluation of Worst-Case Test Conditions for SEE on Power DMOSFETs. In Proceedings of the 2006 IEEE Radiation Effects Data Workshop, Ponte Vedra Beach, FL, USA, 17–21 July 2006; pp. 165–171. [Google Scholar] [CrossRef]
  11. Liu, S.; Titus, J.L.; Zafrani, M.; Cao, H.; Carrier, D.; Sherman, P. Worst-Case Test Conditions of SEGR for Power DMOSFETs. IEEE Trans. Nucl. Sci. 2010, 57, 279–287. [Google Scholar] [CrossRef]
  12. Lauenstein, J.-M.; Goldsman, N.; Liu, S.; Titus, J.L.; Ladbury, R.L.; Kim, H.S.; Phan, A.M.; LaBel, K.A.; Zafrani, M.; Sherman, P. Effects of Ion Atomic Number on Single-Event Gate Rupture (SEGR) Susceptibility of Power MOSFETs. IEEE Trans. Nucl. Sci. 2011, 58, 2628–2636. [Google Scholar] [CrossRef] [Green Version]
  13. Titus, J.L. An Updated Perspective of Single Event Gate Rupture and Single Event Burnout in Power MOSFETs. IEEE Trans. Nucl. Sci. 2013, 60, 1912–1928. [Google Scholar] [CrossRef]
  14. Privat, A.; Touboul, A.D.; Petit, M.; Huselstein, J.J.; Wrobel, F.; Forest, F.; Vaille, J.R.; Bourdarie, S.; Arinero, R.; Chatry, N.; et al. Impact of Single Event Gate Rupture and Latent Defects on Power MOSFETs Switching Operation. IEEE Trans. Nucl. Sci. 2014, 61, 1856–1864. [Google Scholar] [CrossRef]
  15. Hohl, J.; Johnnson, G. Features of the triggering mechanism for single event burnout of power MOSFETs. IEEE Trans. Nucl. Sci. 1989, 36, 2260–2266. [Google Scholar] [CrossRef]
  16. Darwish, M.; Yue, C.; Lui, K.H.; Giles, F.; Chan, B.; Chen, K.-I.; Pattanayak, D.; Chen, Q.; Terrill, K.; Owyang, K. A new power W-gated trench MOSFET (WMOSFET) with high switching performance. In Proceedings of the ISPSD ‘03, 2003 IEEE 15th International Symposium on Power Semiconductor Devices and ICs, Cambridge, UK, 14–17 April 2003. [Google Scholar] [CrossRef]
  17. Wan, X.; Zhou, W.S.; Ren, S.; Liu, D.G.; Xu, J.; Bo, H.L.; Zhang, E.X.; Schrimpf, R.D.; Fleetwood, D.M.; Ma, T.P. SEB Hardened Power MOSFETs with High-K Dielectrics. IEEE Trans. Nucl. Sci. 2015, 62, 2830–2836. [Google Scholar] [CrossRef]
  18. Javanainen, A.; Ferlet-Cavrois, V.; Bosser, A.; Jaatinen, J.; Kettunen, H.; Muschitiello, M.; Pintacuda, F.; Rossi, M.; Schwank, J.R.; Shaneyfelt, M.R.; et al. SEGR in SiO2–Si3N4 Stacks. IEEE Trans. Nucl. Sci. 2014, 61, 1902–1908. [Google Scholar] [CrossRef]
  19. Lu, J.; Liu, H.; Luo, J.; Wang, L.; Li, B.; Li, B.; Zhang, G.; Han, Z. Improved single-event hardness of trench power MOSFET with a widened split gate. In Proceedings of the 2016 16th European Conference on Radiation and Its Effects on Components and Systems (RADECS), Bremen, Germany, 19–23 September 2016; pp. 1–5. [Google Scholar] [CrossRef]
  20. Muthuseenu, K.; Barnaby, H.J.; Galloway, K.F.; Koziukov, A.E.; Maksimenko, T.A.; Vyrostkov, M.Y.; Bu-Khasan, K.B.; Kalashnikova, A.A.; Privat, A. Analysis of SEGR in Silicon Planar Gate Super-Junction Power MOSFETs. IEEE Trans. Nucl. Sci. 2021, 68, 611–616. [Google Scholar] [CrossRef]
  21. MIL-STD-750-1 “Environmental Test Methosd for Semiconductor Devices Part 1: Test Methods 1000 through 1999”. Available online: http://www.assistdocs.com (accessed on 21 August 2012).
  22. Chen, Z.; Zhang, C.; Wu, M.; Wang, T.; Zeng, Y.; Wan, X.; Jin, H.; Xu, J.; Tang, M. Analysis and Mitigation of Single-Event Gate Rupture in VDMOS With Termination Structure. IEEE Trans. Nucl. Sci. 2021, 68, 1272–1278. [Google Scholar] [CrossRef]
Figure 1. Device structure: cross-sectional SEM photograph.
Figure 1. Device structure: cross-sectional SEM photograph.
Micromachines 14 00688 g001
Figure 2. The basic test circuit for SEB and SEGR.
Figure 2. The basic test circuit for SEB and SEGR.
Micromachines 14 00688 g002
Figure 3. The single event test data of the trench VDMOS: (a) VDS = 24 V, VGS = 0 V; (b) VDS = 48 V, VGS = 0 V.
Figure 3. The single event test data of the trench VDMOS: (a) VDS = 24 V, VGS = 0 V; (b) VDS = 48 V, VGS = 0 V.
Micromachines 14 00688 g003aMicromachines 14 00688 g003b
Figure 4. One hot spot detected by the EMMI (a) and the enlarged image under a microscope (b). The red dash frame in (b) represents the cell regions of the device.
Figure 4. One hot spot detected by the EMMI (a) and the enlarged image under a microscope (b). The red dash frame in (b) represents the cell regions of the device.
Micromachines 14 00688 g004
Figure 5. The FIB cut cross section of the hot spot by SEM (a) and the enlarged image of the red dash frame in (a) by SEM (b).
Figure 5. The FIB cut cross section of the hot spot by SEM (a) and the enlarged image of the red dash frame in (a) by SEM (b).
Micromachines 14 00688 g005
Figure 6. The cross section of the cell (a) and the termination (gate bus) (b). The red dotted arrows show the incident position and direction in simulation.
Figure 6. The cross section of the cell (a) and the termination (gate bus) (b). The red dotted arrows show the incident position and direction in simulation.
Micromachines 14 00688 g006
Figure 7. Experimental and simulated breakdown characteristics for the trench VDMOS.
Figure 7. Experimental and simulated breakdown characteristics for the trench VDMOS.
Micromachines 14 00688 g007
Figure 8. Simulated electric field of gate oxide at the position of the maximum electric field in the cell and the termination under heavy-ion strikes.
Figure 8. Simulated electric field of gate oxide at the position of the maximum electric field in the cell and the termination under heavy-ion strikes.
Micromachines 14 00688 g008
Figure 9. Hole density distribution near gate oxide in (a) the cell and (b) the termination at 100 ns.
Figure 9. Hole density distribution near gate oxide in (a) the cell and (b) the termination at 100 ns.
Micromachines 14 00688 g009
Figure 10. The cross section of the SEGR-hardened termination.
Figure 10. The cross section of the SEGR-hardened termination.
Micromachines 14 00688 g010
Figure 11. Simulated electric field of gate oxide at the position of the maximum electric field in the conventional termination and the SEGR-hardened termination with time under heavy-ion strikes.
Figure 11. Simulated electric field of gate oxide at the position of the maximum electric field in the conventional termination and the SEGR-hardened termination with time under heavy-ion strikes.
Micromachines 14 00688 g011
Figure 12. Hole density distribution near gate oxide for the conventional termination and the SEGR-hardened termination: (a) conventional termination; (b) SEGR-hardened termination.
Figure 12. Hole density distribution near gate oxide for the conventional termination and the SEGR-hardened termination: (a) conventional termination; (b) SEGR-hardened termination.
Micromachines 14 00688 g012
Figure 13. Comparison of IDS when VDS is 27 V and 28 V of the conventional termination and when VDS is 60 V of the SEGR-hardened termination.
Figure 13. Comparison of IDS when VDS is 27 V and 28 V of the conventional termination and when VDS is 60 V of the SEGR-hardened termination.
Micromachines 14 00688 g013
Figure 14. Simulated breakdown characteristic curves for the conventional termination and the SEGR-hardened termination.
Figure 14. Simulated breakdown characteristic curves for the conventional termination and the SEGR-hardened termination.
Micromachines 14 00688 g014
Table 1. The main parameters of the device.
Table 1. The main parameters of the device.
ParameterValue
Cell pitch, Wcell (μm)1.5
Thickness of drift layer, Ld (μm)8
Thickness of gate oxide, tox (μm)0.06
Concentration of drift layer, Nd (cm−3)3 × 1016
Concentration of P-body, Np (cm−3)1.9 × 1017
Concentration of P+ and N+ (cm−3)1 × 1019
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Wang, Y.; Liu, T.; Qian, L.; Wu, H.; Yu, Y.; Tao, J.; Cheng, Z.; Hu, S. Analysis and Hardening of SEGR in Trench VDMOS with Termination Structure. Micromachines 2023, 14, 688. https://doi.org/10.3390/mi14030688

AMA Style

Wang Y, Liu T, Qian L, Wu H, Yu Y, Tao J, Cheng Z, Hu S. Analysis and Hardening of SEGR in Trench VDMOS with Termination Structure. Micromachines. 2023; 14(3):688. https://doi.org/10.3390/mi14030688

Chicago/Turabian Style

Wang, Yuan, Tao Liu, Lingli Qian, Hao Wu, Yiren Yu, Jingyu Tao, Zijun Cheng, and Shengdong Hu. 2023. "Analysis and Hardening of SEGR in Trench VDMOS with Termination Structure" Micromachines 14, no. 3: 688. https://doi.org/10.3390/mi14030688

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop